.1.3.6.1.4.1.629.227.1.2 · 1 row entry · 5 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondVoaPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondVoaPortTable'
List of ports supporting variable optical attenuation at the
port level.
nbsSigCondVoaPortEntry row .1.3.6.1.4.1.629.227.1.2.1
Column Syntax OID
The Mib2 ifIndex of the attenuable port.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.1.2.1.1
Persistent and immediately updated. User-requested
attenuation to be applied to received signal, expressed in
millidecibels (mdB).
Not supported value: -200000
Integer32r/w
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.1.2.1.2
Attenuation actually being applied to received signal, in
millidecibels (mdB).
Not supported value: -200000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.1.2.1.3
Persistent and immediately updated. User-requested
attenuation to be applied before transmitting signal,
expressed in millidecibels (mdB).
Not supported value: -200000
Integer32r/w
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.1.2.1.4
Attenuation actually being applied before transmitting
signal, in millidecibels (mdB).
Not supported value: -200000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.1.2.1.5
.1.3.6.1.4.1.629.227.2.2 · 1 row entry · 4 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondVoaChannelRangeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondVoaChannelRangeTable'
The channel attenuation values supported on this port.
nbsSigCondVoaChannelRangeEntry row .1.3.6.1.4.1.629.227.2.2.1
Column Syntax OID
The Mib2 ifIndex of the mux port.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.2.2.1.1
The lowest channel attenuation value supported by this mux
port, expressed in millidecibels (mdB).

This is the smallest attenuation supported.
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.2.2.1.2
The greatest channel attenuation value supported by this mux
port, expressed in millidecibels (mdB).

This is the largest attenuation supported.
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.2.2.1.3
The precision of the VOA, expressed in
millidecibels (mdB).

The minimum difference between attenuation values.
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.2.2.1.4
.1.3.6.1.4.1.629.227.3.2 · 1 row entry · 3 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondRamanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondRamanTable'
Table of Raman readings.
nbsSigCondRamanEntry row .1.3.6.1.4.1.629.227.3.2.1
Raman readings on an individual port.
Column Syntax OID
The Mib2 ifIndex of the Raman port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.3.2.1.1
Persistent and immediately updated. User-requested pump
power, in microwatts (uW).
User interfaces should show this in millWatts (mW).
Not supported value: -1
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.3.2.1.2
Agent reported pump power, in microwatts (uW).
User interfaces should show this in millWatts (mW).
Not supported value: -1
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.3.2.1.3
.1.3.6.1.4.1.629.227.20.2 · 1 row entry · 7 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondEqualizeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondEqualizeTable'
List of WDM ports supporting power level equalization.
nbsSigCondEqualizeEntry row .1.3.6.1.4.1.629.227.20.2.1
Equalization parameters and settings
Column Syntax OID
The Mib2 ifIndex of this channel's WDM port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.20.2.1.1
Used to enable or disable channel equalization on this port.

The value disabled(2) disables the feature. No attempt to
equalize power levels will be made, and no equalization events
will be triggered.
Enumerationr/w
Enumerated Values:
1notSupported
2disabled
3enabled
.1.3.6.1.4.1.629.227.20.2.1.10
The lowest channel TxPower setting the equalizer supports
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.20.2.1.11
The highest channel TxPower setting the equalizer supports
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.20.2.1.12
The user-settable minimum channel TxPower level.

Allowed values are from nbsSigCondEqualizeLimitMin to
nbsSigCondEqualizeLimitMax, inclusive.

Equalizer must attempt to maintain the channels…
NBS-MIBNbsTcMilliDbr/w
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.20.2.1.21
The user-settable maximum channel TxPower level.

Allowed values are from nbsSigCondEqualizeLimitMin to
nbsSigCondEqualizeLimitMax, inclusive.

Equalizer must attempt to maintain the channels…
NBS-MIBNbsTcMilliDbr/w
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.20.2.1.22
Equalizer must attempt to maintain the channels' signal at
this level.

Allowed values are from nbsSigCondEqualizeLimitMin to
nbsSigCondEqualizeLimitMax, inclusive.
NBS-MIBNbsTcMilliDbr/w
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.20.2.1.23
.1.3.6.1.4.1.629.227.30.2 · 1 row entry · 5 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondRedundTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondRedundTable'
List of ports supporting power level redundancy.
nbsSigCondRedundEntry row .1.3.6.1.4.1.629.227.30.2.1
Redundancy settings
Column Syntax OID
The Mib2 ifIndex of this channel's Redundancy port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.30.2.1.1
The lowest channel Power setting
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.30.2.1.5
The highest channel Power setting
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.30.2.1.8
The lowest channel Power setting before the redundancy kicks in
NBS-MIBNbsTcMilliDbr/w
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.30.2.1.10
The highest channel Power setting before the redundancy kicks in
NBS-MIBNbsTcMilliDbr/w
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.30.2.1.15
.1.3.6.1.4.1.629.227.40.2 · 1 row entry · 7 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondPortTable'
Table of VOA and VGA ports.
nbsSigCondPortEntry row .1.3.6.1.4.1.629.227.40.2.1
Column Syntax OID
The Mib2 ifIndex of the port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.40.2.1.1
Measured receiver power, in millidecibels (mdBm).
User interfaces should show this in decibels (dBm).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.2
Measured transmitter power, in millidecibels (mdBm).
User interfaces should show this in decibels (dBm).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.3
Measured back reflection power, in millidecibels (mdBm).
User interfaces should show this in decibels (dBm).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.4
Measured minimum receiver power, in millidecibels (mdBm).
User interfaces should show this in decibels (dBm).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.5
Measured maximum receiver power, in millidecibels (mdBm).
User interfaces should show this in decibels (dBm).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.6
Measured Noise Figure value, in millidecibels (mdB).
User interfaces should show this in decibels (dB).
Not supported value: -100000
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.40.2.1.7
.1.3.6.1.4.1.629.227.50.2 · 1 row entry · 6 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondChannelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondChannelTable'
WDM channels within a mux port
nbsSigCondChannelEntry row .1.3.6.1.4.1.629.227.50.2.1
Column Syntax OID
The Mib2 ifIndex of this channel's mux port
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.50.2.1.1
The center frequency of this channel, in MHz
NBS-MIBNbsTcMHz
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.629.227.50.2.1.2
The dynamically measured or calculated receive signal strength
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.50.2.1.11
The dynamically measured or calculated transmit signal
strength
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.50.2.1.12
The actual attenuation applied to this channel, possibly
representing changes made by the equalization process if
nbsSigCondEqualizeState is enabled for this IfIndex.
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.50.2.1.14
The actual attenuation applied to this channel, possibly
representing changes made by the equalization process if
nbsSigCondEqualizeState is enabled for this IfIndex.
NBS-MIBNbsTcMilliDb
Type Constraints:
range: -2147483648..100000
.1.3.6.1.4.1.629.227.50.2.1.15
.1.3.6.1.4.1.629.227.60.2 · 1 row entry · 12 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk nbsSigCondVodPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NBS-SIGCOND-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NBS-SIGCOND-MIB::nbsSigCondVodPortTable'
List of ports supporting variable optical attenuation at the
port level.
nbsSigCondVodPortEntry row .1.3.6.1.4.1.629.227.60.2.1
Column Syntax OID
The Mib2 ifIndex of the dispersion compensation port.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.629.227.60.2.1.1
Minimum allowed dispersion compensation in ps/nm.

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.2
Maximum allowed dispersion compensation in ps/nm.

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.3
Desired dispersion compensation in ps/nm.

Not supported value: 0x80000000
Integer32r/w
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.4
Actual dispersion in ps/nm

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.5
The center frequency of the offset, in GigaHertz
(GHz), unless FreqExponent != 9.

Not supported value: 0
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.60.2.1.10
In GigaHertz (GHz), unless FreqExponent != 9.

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.11
In GigaHertz (GHz), unless FreqExponent != 9.

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.12
The spacing of the allowable grid offsets that this port
supports, in GigaHertz (GHz), unless FreqExponent != 9.

Not supported value: 0
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.60.2.1.13
The exponent of all the GridOffset values (including
GridOffsetStep).

9 (the default) indicates all units are in GigaHertz (GHz).
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.629.227.60.2.1.14
In GigaHertz (GHz), unless FreqExponent != 9.

Not supported value: 0x80000000
Integer32r/w
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.15
In GigaHertz (GHz), unless FreqExponent != 9.

Not supported value: 0x80000000
Integer32
Constraints:
range: -100000-100000
.1.3.6.1.4.1.629.227.60.2.1.16