MX-FXS-METER-PULSE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
2
.1.3.6.1.4.1.4935.99.30.1.30 · 1 row entry · 2 columns
Table that contains meter pulse parameters for each MGCP
endpoint.
fxsMeterPulseEntry entry .1.3.6.1.4.1.4935.99.30.1.30.1
Table entry of the table that contains meter pulse
parameters.
Indexes
Column Syntax OID
fxsMeterPulseDuration
This is the pulse duration (voltage is ON) in ms.

The clock precision is 10 ms, i.e. you can
request 213 ms, but the system will play each pulse
213 +/- 10 ms.
Unsigned32r/w
Constraints:
range: 120-220
.1.3.6.1.4.1.4935.99.30.1.30.1.10
fxsMeterPauseDuration
This is the pause duration (voltage is OFF) in ms.

The clock precision is 10 ms, i.e. you can
request 327 ms, but the system will pause for
327 +/- 10 ms.
Unsigned32r/w
Constraints:
range: 100-600
.1.3.6.1.4.1.4935.99.30.1.30.1.15