MRV-IR-HDAM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
54
.1.3.6.1.4.1.33.100.4.1.1 · 1 row entry · 5 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irHdamUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irHdamUnitTable'
A list of hdam unit entries.
irHdamUnitEntry row .1.3.6.1.4.1.33.100.4.1.1.1
An hdam unit entry.
Column Syntax OID
The port index to which this hdam unit is connected.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.33.100.4.1.1.1.1
The HDAM unit firmware version string.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.1.1.1.2
The HDAM unit connection status.
Enumeration
Enumerated Values:
1connected
2disconnected
.1.3.6.1.4.1.33.100.4.1.1.1.3
The type of power used by the hdam device.
Enumeration
Enumerated Values:
1powerAC
2powerDC
.1.3.6.1.4.1.33.100.4.1.1.1.4
This object is used to perform an action on the HDAM unit.
A read of this object always returns the value other(1).
Setting this object to reset(2) causes the unit to be reset.
Enumerationr/w
Enumerated Values:
1other
2reset
.1.3.6.1.4.1.33.100.4.1.1.1.5
.1.3.6.1.4.1.33.100.4.1.2 · 1 row entry · 3 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irHdamModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irHdamModuleTable'
A list of hdam module entries.
irHdamModuleEntry row .1.3.6.1.4.1.33.100.4.1.2.1
An hdam module entry.
Column Syntax OID
The port index to which this hdam unit is connected.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.33.100.4.1.2.1.1
The slot index for this module entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.33.100.4.1.2.1.2
The type of module in the slot.
IrHdamModuleType
Type Values:
1empty
2alarmModule
3controlModule
4analoglModule
.1.3.6.1.4.1.33.100.4.1.2.1.3
.1.3.6.1.4.1.33.100.4.1.3 · 1 row entry · 6 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irHdamPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irHdamPowerSupplyTable'
A list of hdam power supply entries.
irHdamPowerSupplyEntry row .1.3.6.1.4.1.33.100.4.1.3.1
An hdam power supply entry.
Column Syntax OID
The index of the port to which the hdam unit is attached.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.33.100.4.1.3.1.1
The index of the hdam power unit.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.33.100.4.1.3.1.2
This indicates if the power unit is present or not.
Enumeration
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.33.100.4.1.3.1.3
This indicates if the power unit is plugged into a power source.
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.33.100.4.1.3.1.4
This indicates the status of the internal power feed to the device
components.
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.33.100.4.1.3.1.5
The overall status of the power unit.
Enumeration
Enumerated Values:
1on
2off
3failed
.1.3.6.1.4.1.33.100.4.1.3.1.6
.1.3.6.1.4.1.33.100.4.2.1 · 1 row entry · 13 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irAlarmConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irAlarmConfigTable'
A list of alarm config entries.
irAlarmConfigEntry row .1.3.6.1.4.1.33.100.4.2.1.1
An hdam alarm config entry.
Column Syntax OID
The port index on which the alarm unit is attached.
Integer32
Constraints:
range: 1-48
.1.3.6.1.4.1.33.100.4.2.1.1.1
The slot in the alarm unit which identifies this module.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.33.100.4.2.1.1.2
An integer which uniquely identifies an alarm on this module.
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.33.100.4.2.1.1.3
The name assigned to the alarm.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.2.1.1.4
The current state of the alarm contacts.
IrContactState
Type Values:
1open
2closed
.1.3.6.1.4.1.33.100.4.2.1.1.5
The contact state (open or closed) which indicates the fault
condition. If the value of this object and irAlarmContactState
is the same, then the alarm has been triggered.
IrContactStater/w
Type Values:
1open
2closed
.1.3.6.1.4.1.33.100.4.2.1.1.6
The number of seconds the alarm must be in the fault state
before it is considered valid.
Integer32r/w
Constraints:
range: 0-1800
.1.3.6.1.4.1.33.100.4.2.1.1.7
This indicates whether the audible alarm on the unit will sound
when this alarm is generated.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.33.100.4.2.1.1.8
This indicates whether an snmp trap will be generated when this
alarm is generated.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.33.100.4.2.1.1.9
The trap severity assigned to this alarm. This value will be sent
when an alarm fires and an snmp trap is generated.
MRV-IR-SYSTEM-MIBTrapSeverityr/w
Type Values:
1cleared
2informational
3warning
4minor
5major
6critical
.1.3.6.1.4.1.33.100.4.2.1.1.10
The number of times the alarm has been generated since the unit
was started.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.33.100.4.2.1.1.11
A timestamp string indicating the time the last alarm was generated.
A null string indicates that the alarm has not been generated.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.2.1.1.12
A user configurable alarm description string.
OctetStringr/w
Constraints:
range: 0-64
.1.3.6.1.4.1.33.100.4.2.1.1.13
.1.3.6.1.4.1.33.100.4.3.1 · 1 row entry · 7 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irControlConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irControlConfigTable'
A list of control config entries.
irControlConfigEntry row .1.3.6.1.4.1.33.100.4.3.1.1
A control config entry.
Column Syntax OID
The port index on which the control unit is attached.
Integer32
Constraints:
range: 1-48
.1.3.6.1.4.1.33.100.4.3.1.1.1
The slot in the control unit which identifies this module.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.33.100.4.3.1.1.2
An integer which uniquely identifies a control on this module.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.33.100.4.3.1.1.3
The name assigned to the control.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.3.1.1.4
The current value of the control state.
IrContactStater/w
Type Values:
1open
2closed
.1.3.6.1.4.1.33.100.4.3.1.1.5
The value of the control state that activates the attached
device.
IrContactStater/w
Type Values:
1open
2closed
.1.3.6.1.4.1.33.100.4.3.1.1.6
A user configurable control description string.
OctetStringr/w
Constraints:
range: 0-64
.1.3.6.1.4.1.33.100.4.3.1.1.7
.1.3.6.1.4.1.33.100.4.4.1 · 1 row entry · 20 columns
Uses the mrv variant from /opt/observium/mibs/mrv.
Command help
Walk irAnalogConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MRV-IR-HDAM-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MRV-IR-HDAM-MIB::irAnalogConfigTable'
A list of analog loop config entries.
irAnalogConfigEntry row .1.3.6.1.4.1.33.100.4.4.1.1
An analog loop config entry.
Column Syntax OID
The port index on which the analog unit is attached.
Integer32
Constraints:
range: 1-48
.1.3.6.1.4.1.33.100.4.4.1.1.1
The slot in the analog unit which identifies this module.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.33.100.4.4.1.1.2
An integer which uniquely identifies an analog point on this module.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.33.100.4.4.1.1.3
The name assigned to the analog.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.4.1.1.4
A user configurable analog description string.
OctetStringr/w
Constraints:
range: 0-64
.1.3.6.1.4.1.33.100.4.4.1.1.5
The status of the analog point.
IrAnalogStatusr/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.33.100.4.4.1.1.6
The current analog sensor reading in milliAmps.
OctetString
Constraints:
range: 0-24
.1.3.6.1.4.1.33.100.4.4.1.1.7
The current analog sensor calibrated value.
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.33.100.4.4.1.1.8
The calibration value assigned to the minimum sensor reading.
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.9
The calibration value assigned to the maximum analog sensor reading.
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.10
The calibration margin value. This will be added to the
calibrated analog sensor value.
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.11
A user defined string describing the calibrated units for the
analog sensor.
OctetStringr/w
Constraints:
range: 0-8
.1.3.6.1.4.1.33.100.4.4.1.1.12
The analog sensor high threshold value. A value of -0 indicates
threshold is not configured.
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.13
The analog sensor low threshold value. A value of -0 indicates
threshold is not configured.
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.14
The severity value of the analog sensor assigned to the low threshold.
This value will be sent in the threshold trap.
MRV-IR-SYSTEM-MIBTrapSeverityr/w
Type Values:
1cleared
2informational
3warning
4minor
5major
6critical
.1.3.6.1.4.1.33.100.4.4.1.1.15
After crossing a threshold, the delta by which the caliberated
value must drop within the normal range before the alarm
condition is cleared (i.e. a cleared alarm is generated).
OctetStringr/w
Constraints:
range: 0-10
.1.3.6.1.4.1.33.100.4.4.1.1.16
The number of times the analog sensor high threshold has been
crossed since the unit was started.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.33.100.4.4.1.1.17
The number of times the analog sensor low threshold has been
crossed since the unit was started.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.33.100.4.4.1.1.18
A timestamp string indicating the time the analog sensor last
crossed the high threshold. A null string indicates that the
alarm has not been crossed.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.4.1.1.19
A timestamp string indicating the time the analog sensor last
crossed the low threshold. A null string indicates that the
alarm has not been crossed.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.33.100.4.4.1.1.20