MARVELL-POE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
38
.1.3.6.1.4.1.89.108.1 · 1 row entry · 18 columns
Uses the radlan variant from /opt/observium/mibs/radlan.
Command help
Walk rlPethPsePortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MARVELL-POE-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MARVELL-POE-MIB::rlPethPsePortTable'
The table listing additional information for Power Over Ethernet ports.
rlPethPsePortEntry row .1.3.6.1.4.1.89.108.1.1
An entry in the rlPethPsePortTable.
Column Syntax OID
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermo…
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.89.108.1.1.1
This variable uniquely identifies the power Ethernet PSE
port within group pethPsePortGroupIndex to which the
power Ethernet PSE entry is connected.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.89.108.1.1.2
This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.3
This variable indicates on the output current level in milli amper from rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.4
This variable indicates on the output power level in milli watts from rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.5
This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.6
This variable indicates on the hardware status of rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.7
This variable indicates the description of the hardware status of rlPethPsePortIndex.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.89.108.1.1.8
This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.9
This variable is used to bind PoE port to time range.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.89.108.1.1.10
This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.89.108.1.1.11
This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.12
This variable indicates the supported type of the PoE port
RlPoeType
Type Values:
1none
2poe
3poeplus
4poe60w
.1.3.6.1.4.1.89.108.1.1.13
This variable indicates the link partner PoE type.
RlPoeType
Type Values:
1none
2poe
3poeplus
4poe60w
.1.3.6.1.4.1.89.108.1.1.14
This variable enabled the spare pair ALT_B in 60W port to force 4 pair enable.
Enumerationr/w
Enumerated Values:
0forcedEnable
1forcedDisable
.1.3.6.1.4.1.89.108.1.1.15
This variable indicates that spare pair ALT_B is enable.
Enumeration
Enumerated Values:
1fourPairEnable
2fourPairDisable
.1.3.6.1.4.1.89.108.1.1.16
This variable indicates the power allocation in milli watts from power negotiation
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.1.1.17
This variable indicates the protocol owner on power management negotiation protocol
Enumeration
Enumerated Values:
0protocolOwnerNone
1protocolOwnerCDP
2protocolOwnerLLDP
.1.3.6.1.4.1.89.108.1.1.18
.1.3.6.1.4.1.89.108.2 · 1 row entry · 5 columns
Uses the radlan variant from /opt/observium/mibs/radlan.
Command help
Walk rlPethMainPseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MARVELL-POE-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MARVELL-POE-MIB::rlPethMainPseTable'
The table listing additional read - only information for Power Over Ethernet.
rlPethMainPseEntry row .1.3.6.1.4.1.89.108.2.1
An entry in the rlPethMainPseTable.
Column Syntax OID
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermo…
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.89.108.2.1.1
This variable identifies the MCU SW version.
OctetString
Constraints:
range: 0-20
.1.3.6.1.4.1.89.108.2.1.2
This variable identifies the MCU HW version.
OctetString
Constraints:
range: 0-20
.1.3.6.1.4.1.89.108.2.1.3
This variable identifies the MCU HW type (enhanced, plus, none).
Enumeration
Enumerated Values:
1enhanced
2plus
3auto
4nonPoe
5enhancedPlus
6poe60w
.1.3.6.1.4.1.89.108.2.1.4
This variable identifies the guard band in [W] for not connecting
additional ports.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.89.108.2.1.5
.1.3.6.1.4.1.89.108.3 · 1 row entry · 8 columns
Uses the radlan variant from /opt/observium/mibs/radlan.
Command help
Walk rlPethPowerPseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MARVELL-POE-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MARVELL-POE-MIB::rlPethPowerPseTable'
The table listing additional read-write information for Power Over Ethernet - PSE side.
rlPethPowerPseEntry row .1.3.6.1.4.1.89.108.3.1
An entry in the rlPethPowerPseTable.
Column Syntax OID
This variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermo…
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.89.108.3.1.1
This variable identifies the maximum power in [W] supplied by PSE.
Enumerationr/w
Enumerated Values:
0none
1ps1
2ps2
3ps3
.1.3.6.1.4.1.89.108.3.1.2
This variable identifies the maximum power in [W] supplied by PSE + RPS.
Enumerationr/w
Enumerated Values:
0none
1rps1
2rps2
3rps3
.1.3.6.1.4.1.89.108.3.1.3
This variable identifies power management mode.
Enumerationr/w
Enumerated Values:
0portlimit
5classlimit
6maxlimit
.1.3.6.1.4.1.89.108.3.1.4
This variable identifies disconnect method.
Enumerationr/w
Enumerated Values:
0lowestpriority
1nextport
.1.3.6.1.4.1.89.108.3.1.5
This variable identifies the pd temperature sensor.
Integer32
Constraints:
range: -200-200
.1.3.6.1.4.1.89.108.3.1.6
This variable identifies if HW inrush test will be disabled.
by default HW inrush test is enabled.
Enumerationr/w
Enumerated Values:
0enabled
1disabled
.1.3.6.1.4.1.89.108.3.1.7
This variable identifies poe Legacy global configuration mode
Enumerationr/w
Enumerated Values:
0enabled
1disabled
.1.3.6.1.4.1.89.108.3.1.8
.1.3.6.1.4.1.89.108.4 · 1 row entry · 7 columns
Uses the radlan variant from /opt/observium/mibs/radlan.
Command help
Walk rlPethPdPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MARVELL-POE-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MARVELL-POE-MIB::rlPethPdPortTable'
The table listing additional read-write information for Power Over Ethernet - PD side.
rlPethPdPortEntry row .1.3.6.1.4.1.89.108.4.1
An entry in the rlPethPdPortTable.
Column Syntax OID
This variable uniquely identifies the power Ethernet PD
port within group rlPethPdPortGroupIndex to which the
power Ethernet PSE entry is connected.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.89.108.4.1.1
This variable indicates the PoE type of the PD port (AF/AT/60W)
RlPoeType
Type Values:
1none
2poe
3poeplus
4poe60w
.1.3.6.1.4.1.89.108.4.1.2
This variable indicates the operational PoE status of the PD port
RlPoeType
Type Values:
1none
2poe
3poeplus
4poe60w
.1.3.6.1.4.1.89.108.4.1.3
This variable indicates the requested power the PD port request from the PSE in mili-Watts
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.89.108.4.1.4
This variable indicates the available power the PSE port offers to the PD port in mili-Watts
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.89.108.4.1.5
This variable indicates the powered PD port forced mode
RlPoeTyper/w
Type Values:
1none
2poe
3poeplus
4poe60w
.1.3.6.1.4.1.89.108.4.1.6
This variable indicates the protocol owner on power management negotiation protocol
Enumeration
Enumerated Values:
0protocolOwnerNone
1protocolOwnerCDP
2protocolOwnerLLDP
.1.3.6.1.4.1.89.108.4.1.7