LM-SENSORS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
12
.1.3.6.1.4.1.2021.13.16.2 · 1 row entry · 3 columns
Uses the net-snmp variant from /opt/observium/mibs/net-snmp.
Command help
Walk lmTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LM-SENSORS-MIB' -M '/opt/observium/mibs/net-snmp:/opt/observium/mibs/rfc' 'udp:<hostname>:161' 'LM-SENSORS-MIB::lmTempSensorsTable'
Table of temperature sensors and their values.
lmTempSensorsEntry row .1.3.6.1.4.1.2021.13.16.2.1
An entry containing a device and its statistics.
Column Syntax OID
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2021.13.16.2.1.1
The name of the temperature sensor we are reading.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.2021.13.16.2.1.2
The temperature of this sensor in mC.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2021.13.16.2.1.3
.1.3.6.1.4.1.2021.13.16.3 · 1 row entry · 3 columns
Uses the net-snmp variant from /opt/observium/mibs/net-snmp.
Command help
Walk lmFanSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LM-SENSORS-MIB' -M '/opt/observium/mibs/net-snmp:/opt/observium/mibs/rfc' 'udp:<hostname>:161' 'LM-SENSORS-MIB::lmFanSensorsTable'
Table of fan sensors and their values.
lmFanSensorsEntry row .1.3.6.1.4.1.2021.13.16.3.1
An entry containing a device and its statistics.
Column Syntax OID
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2021.13.16.3.1.1
The name of the fan sensor we are reading.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.2021.13.16.3.1.2
The rotation speed of the fan in RPM.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2021.13.16.3.1.3
.1.3.6.1.4.1.2021.13.16.4 · 1 row entry · 3 columns
Uses the net-snmp variant from /opt/observium/mibs/net-snmp.
Command help
Walk lmVoltSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LM-SENSORS-MIB' -M '/opt/observium/mibs/net-snmp:/opt/observium/mibs/rfc' 'udp:<hostname>:161' 'LM-SENSORS-MIB::lmVoltSensorsTable'
Table of voltage sensors and their values.
lmVoltSensorsEntry row .1.3.6.1.4.1.2021.13.16.4.1
An entry containing a device and its statistics.
Column Syntax OID
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2021.13.16.4.1.1
The name of the device we are reading.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.2021.13.16.4.1.2
The voltage in mV.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2021.13.16.4.1.3
.1.3.6.1.4.1.2021.13.16.5 · 1 row entry · 3 columns
Uses the net-snmp variant from /opt/observium/mibs/net-snmp.
Command help
Walk lmMiscSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LM-SENSORS-MIB' -M '/opt/observium/mibs/net-snmp:/opt/observium/mibs/rfc' 'udp:<hostname>:161' 'LM-SENSORS-MIB::lmMiscSensorsTable'
Table of miscellaneous sensor devices and their values.
lmMiscSensorsEntry row .1.3.6.1.4.1.2021.13.16.5.1
An entry containing a device and its statistics.
Column Syntax OID
Reference index for each observed device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.2021.13.16.5.1.1
The name of the device we are reading.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.2021.13.16.5.1.2
The value of this sensor.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2021.13.16.5.1.3