Deprecated MIB objects for managing ERX Edge Router system elements.
See the generic E-series system MIB (Juniper-System-MIB) for the
preferred definitions. If both MIBs are supported, using the
corresponding varbinds from both MIBs to set the same object in a single
PDU is not supported.
Reports a status change for a slot.
This trap is generated on a transition into a stable state (online or
disabled) or on a transition out of online.
juniERXSysPowerStatusChange
.1.3.6.1.4.1.4874.2.2.17.0.2
Reports a change in the status of a power element.
juniERXSysTempFanStatusChange
.1.3.6.1.4.1.4874.2.2.17.0.3
Reports a transition between the three states of the fan subsystem.
When the fan subsystem transitions to the failed state the thermal
protection hold off time begins.
juniERXSysTempStatusChange
.1.3.6.1.4.1.4874.2.2.17.0.4
Reports a change in the temperature status. When the status
transitions to the tooHigh state the system enters thermal protection
mode.
juniERXSysHighMemUtil
.1.3.6.1.4.1.4874.2.2.17.0.5
Report system memory utilization has met the conditions of
juniERXSysHighMemUtilThreshold.
juniERXSysAbatedMemUtil
.1.3.6.1.4.1.4874.2.2.17.0.6
Reports system memory utilization has met the conditions of
juniERXSysAbatedMemUtilThreshold.
juniERXSysTempProtectionStatusChange
.1.3.6.1.4.1.4874.2.2.17.0.7
Notification about changes in the state of Thermal Protection. This
notification is sent when the tempProtectionStatus changes. It is also
sent when the holdOffTimeRemaining is 50% of the holdOffTime.