Juniper-DS1-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
31
juniDsx1ConfigTable
table.1.3.6.1.4.1.4874.2.2.5.1.1
·
1 row entry
·
22 columns
Uses the junose variant from
Command help
/opt/observium/mibs/junose.
Walk juniDsx1ConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Juniper-DS1-MIB' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Juniper-DS1-MIB::juniDsx1ConfigTable'
This table contains entries for DS1/E1 interfaces present in the system.
Each entry describes the characteristics of an DS1/E1 interface.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A bitmap representing the timeslots on the DS1/E1 interface that have
been allocated for service. For channelized DS1/E1, set bits reflect the union of timeslot allocations across all fractional arrangeme… |
Juniper-TCJuniTimeSlotMap Type Constraints: range: 4 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.1 |
||||||||||||||||||||||||||||||||||||||||
|
This variable represents the channel number of the DS1/E1 on its parent
DS3/E3. A value of 0 indicates this DS1/E1 does not have a parent DS3/E3. |
Integer32r/w Constraints: range: 0-28 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.2 |
||||||||||||||||||||||||||||||||||||||||
|
A value which indicates the set of capabilities of the DS1/E1
interface. The value is a sum. This sum initially takes the value zero. Then, for each capability, C, in the range 1 through 3, that this in… |
Integer32 Constraints: range: 0-7 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.3 |
||||||||||||||||||||||||||||||||||||||||
|
This variable represents the DS1/E1 interface mode. The value of the
juniDsx1Capabilities object for the DS1/E1 interface indicates the valid set of values for this object. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.4 |
||||||||||||||||||||||||||||||||||||||||
|
A value which indicates the set of line build out capabilities of the
DS1/E1 interface. The value is a sum. This sum initially takes the value zero. Then, for each line build out capability, C, in the r… |
Integer32 Constraints: range: 0-3 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.5 |
||||||||||||||||||||||||||||||||||||||||
|
This variable represents the configured line build out type of the
DS1/E1 interface. The value of the juniDsx1LineBuildOutCapabilities object for the DS1/E1 interface indicates the valid set of values for this object. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.6 |
||||||||||||||||||||||||||||||||||||||||
|
This variable represents the configured line attenuation of the DS1/E1
interface. Note that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to l… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.7 |
||||||||||||||||||||||||||||||||||||||||
|
This variable represents the length of the DS1/E1 line in meters. Note
that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to shortHaul(1). |
metersInteger32r/w Constraints: range: 0-64000 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.8 |
||||||||||||||||||||||||||||||||||||||||
|
The ifIndex of the interface over which this Dsx1 interface is to be
layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation. |
IF-MIBInterfaceIndexOrZeror/w Type Constraints: range: 0..2147483647Description: This textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits… |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.9 |
||||||||||||||||||||||||||||||||||||||||
|
Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this … |
SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.10 |
||||||||||||||||||||||||||||||||||||||||
|
This variable indicates what type of code is being sent across the DS1
interface by the device. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.11 |
||||||||||||||||||||||||||||||||||||||||
|
This bitmap indicates the yellow alarm settings, and is the sum of the
capabilities. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.12 |
||||||||||||||||||||||||||||||||||||||||
|
This variable indicates the remote loopback setting.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.13 |
||||||||||||||||||||||||||||||||||||||||
|
Specifies the interface is used in carrier environment.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.14 |
||||||||||||||||||||||||||||||||||||||||
|
This is the equipment identification code.
|
OctetStringr/w Constraints: range: 0-10 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.15 |
||||||||||||||||||||||||||||||||||||||||
|
This is the location identification code.
|
OctetStringr/w Constraints: range: 0-11 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.16 |
||||||||||||||||||||||||||||||||||||||||
|
This is the frame identification code.
|
OctetStringr/w Constraints: range: 0-10 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.17 |
||||||||||||||||||||||||||||||||||||||||
|
This is the unit identification code.
|
OctetStringr/w Constraints: range: 0-6 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.18 |
||||||||||||||||||||||||||||||||||||||||
|
This is the facility identification code.
|
OctetStringr/w Constraints: range: 0-38 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.19 |
||||||||||||||||||||||||||||||||||||||||
|
This is the equipment port number.
|
OctetStringr/w Constraints: range: 0-4 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.20 |
||||||||||||||||||||||||||||||||||||||||
|
This is the generator number.
|
OctetStringr/w Constraints: range: 0-38 |
.1.3.6.1.4.1.4874.2.2.5.1.1.1.21 |
||||||||||||||||||||||||||||||||||||||||
|
Specifies transmission enabling.
path - Bit 0 for path transmit. When this bit is set indicates path transmit is enabled; otherwise path transmit disabled. idlesignal - Bit 1 for idlesig… |
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.1.1.22 |
.1.3.6.1.4.1.4874.2.2.5.1.3
·
1 row entry
·
9 columns
Uses the junose variant from
Command help
/opt/observium/mibs/junose.
Walk juniDsx1FarEndConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Juniper-DS1-MIB' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Juniper-DS1-MIB::juniDsx1FarEndConfigTable'
The DS1 Far End Configuration table.
An entry in the DS1 Far End Configuration table.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The index value which uniquely identifies the DS1 interface to which
this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value a dsx1Li… |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.1 |
||||
|
This is the Far End Equipment Identification code that describes the
specific piece of equipment. It is sent within the Path Identification Message. |
OctetString Constraints: range: 0-10 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.2 |
||||
|
This is the Far End Location Identification code that describes the
specific location of the equipment. It is sent within the Path Identification Message. |
OctetString Constraints: range: 0-11 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.3 |
||||
|
This is the Far End Frame Identification code that identifies where the
equipment is located within a building at a given location. It is sent within the Path Identification Message. |
OctetString Constraints: range: 0-10 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.4 |
||||
|
This is the Far End code that identifies the equipment location within
a bay. It is sent within the Path Identification Message. |
OctetString Constraints: range: 0-6 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.5 |
||||
|
This code identifies a specific Far End DS1 path. It is sent within
the Path Identification Message. |
OctetString Constraints: range: 0-38 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.6 |
||||
|
This code identifies the port number of the Far End DS1. It is sent
within the Idle Signal Message. |
OctetString Constraints: range: 0-4 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.7 |
||||
|
This code identifies the Far End DS1 Generator Number. It is sent
within the Test Signal Message. |
OctetString Constraints: range: 0-38 |
.1.3.6.1.4.1.4874.2.2.5.1.3.1.8 |
||||
|
Specifies the interface is used in carrier environment. It is sent
with all FDL messages. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4874.2.2.5.1.3.1.9 |