IEEE8021-ST-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
25
.1.3.111.2.802.1.1.30.1.1.1 · 1 row entry · 3 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021STMaxSDUTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-ST-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-ST-MIB::ieee8021STMaxSDUTable'
A table containing a set of max SDU 
parameters, one for each traffic class.
All writeable objects in this table must be
persistent over power up restart/reboot.
ieee8021STMaxSDUEntry row .1.3.111.2.802.1.1.30.1.1.1.1
A list of objects containing Max SDU size
for each traffic class supported by the Port.
Column Syntax OID
The traffic class number associated with the row of
the table.

A row in this table is created for each traffic class
that is supported by the Port
IEEE8021STTrafficClassValue
Type Constraints:
range: 0..7
.1.3.111.2.802.1.1.30.1.1.1.1.1
The value of the MaxSDU parameter for the traffic class.
This value is represented as an unsigned integer. A value
of 0 is interpreted as the max SDU size supported by
the underlying MAC.

The default valu…
octetsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.1.1.1.2
A counter of transmission overrun events, where
a PDU is still being transmitted by a MAC at the
time when the transmission gate for the queue closed.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.30.1.1.1.1.3
.1.3.111.2.802.1.1.30.1.2.1 · 1 row entry · 22 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk ieee8021STParametersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-ST-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-ST-MIB::ieee8021STParametersTable'
A table that contains the per-port manageable parameters for 
traffic scheduling.
          
For a given Port, a row in the table exists.
          
All writable objects in this table must be
persistent over power up restart/reboot.
ieee8021STParametersEntry row .1.3.111.2.802.1.1.30.1.2.1.1
A list of objects that contains the manageable parameters for
traffic scheduling for a port.
Column Syntax OID
The GateEnabled parameter determines whether traffic scheduling
is active (true) or inactive (false).

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.30.1.2.1.1.1
The administrative value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds to traffic class 7,
the LS bit to traffic…
OctetStringr/w
Constraints:
range: 1-1
.1.3.111.2.802.1.1.30.1.2.1.1.2
The operational value of the GateStates parameter for the Port.
The bits of the octet represent the gate states for the
corresponding traffic classes; the MS bit corresponds to traffic class 7,
the LS bit to traffic cl…
OctetString
Constraints:
range: 1-1
.1.3.111.2.802.1.1.30.1.2.1.1.3
The administrative value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
AdminControlList.

The value of this object MUST be retained across
reinitial…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.4
The operational value of the ListMax parameter for the Port.
The integer value indicates the number of entries (TLVs) in the
OperControlList.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.5
The administrative value of the ControlList parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as a TLV, as follows.
The first octet o…
OctetStringr/w .1.3.111.2.802.1.1.30.1.2.1.1.6
The operational value of the ListMax parameter for the Port.
The octet string value represents the contents of the control list as
an ordered list of TLVs, as follows.
The first octet of each TLV is interpreted as a ga…
OctetString .1.3.111.2.802.1.1.30.1.2.1.1.7
The administrative value of the numerator of the CycleTime
parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this object…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.8
The administrative value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle time as
a rational number of seconds.

The value of this obj…
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.9
The operational value of the numerator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the cycle
time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.10
The operational value of the denominator of the
CycleTime parameter for the Port.
The numerator and denominator together represent the
cycle time as a rational number of seconds.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.11
The administrative value of the CycleTimeExtension
parameter for the Port.
The value is an unsigned integer number of nanoseconds.

The value of this object MUST be retained across
reinitializations of t…
nanosecondsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.12
The operational value of the CycleTimeExtension parameter for the Port.
The value is an unsigned integer number of nanoseconds.
nanosecondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.13
The administrative value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValuer/w
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.14
The operationsl value of the BaseTime parameter for the Port.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.15
The ConfigChange parameter signals the start of a
configuration change
when it is set to TRUE. This should only be done
when the various administrative parameters
are all set to appropriate values.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.30.1.2.1.1.16
The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
PTP timeIEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.17
The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.

The value of this object MUST be retained across
reinitializations of the management system.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.18
The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit integer number of nanoseconds.
IEEE8021STPTPtimeValue
Type Constraints:
range: 10
.1.3.111.2.802.1.1.30.1.2.1.1.19
The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress
but has not yet completed.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.111.2.802.1.1.30.1.2.1.1.20
A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old
schedule still running and the requested base time was
in the past.
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.111.2.802.1.1.30.1.2.1.1.21
The maximum value supported by this Port of the
AdminControlListLength and OperControlListLength
parameters.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.111.2.802.1.1.30.1.2.1.1.22