IEEE8021-ST-MIB
The Bridge MIB module for managing devices that support the Scheduled Traffic Enhancements for IEEE 802.1Q Bridges.
Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q.
Copyright (C) IEEE (2018). This version of this MIB module is part of IEEE Std 802.1Q; see the draft itself for full legal notices.
- Source file
IEEE8021-ST-MIB- Last revised
- Identity
ieee8021STMib- Base OID
1.3.111.2.802.1.1.30- Objects
- 0 scalars · 25 columns
- Tables
- 2 tables
Net-SNMP examples using the rfc MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
/usr/bin/snmptranslate -Pud -Ir -On -m 'IEEE8021-ST-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IEEE8021-ST-MIB::ieee8021STMib'
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IEEE8021-ST-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-ST-MIB::ieee8021STMib'
Imported Objects
| IEEE8021-BRIDGE-MIB | ieee8021BridgeBaseComponentId ieee8021BridgeBasePort |
| IEEE8021-TC-MIB | ieee802dot1mibs |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Counter64 MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION (no object page) TruthValue |
.1.3.111.2.802.1.1.30.1.1.1
· 3 columns
A table containing a set of max SDU parameters, one for each traffic class. All writeable objects in this table must be persistent over power up restart/reboot.
.1.3.111.2.802.1.1.30.1.1.1.1
| Column | Syntax | OID |
|---|---|---|
| ieee8021STTrafficClass | IEEE8021STTrafficClassValue | .1.3.111.2.802.1.1.30.1.1.1.1.1 |
| ieee8021STMaxSDU | octetsSNMPv2-SMIUnsigned32r/w | .1.3.111.2.802.1.1.30.1.1.1.1.2 |
| ieee8021TransmissionOverrun | SNMPv2-SMICounter64 | .1.3.111.2.802.1.1.30.1.1.1.1.3 |
.1.3.111.2.802.1.1.30.1.2.1
· 22 columns
A table that contains the per-port manageable parameters for traffic scheduling.
For a given Port, a row in the table exists.
All writable objects in this table must be persistent over power up restart/reboot.
.1.3.111.2.802.1.1.30.1.2.1.1
Type Definitions (2)
| Type | Syntax | Constraints |
|---|---|---|
| IEEE8021STPTPtimeValue | OctetString | 1 constraints |
| IEEE8021STTrafficClassValue | Unsigned32 | 1 constraints |
Conformance Groups (1)
ieee8021STObjectsGroup .1.3.111.2.802.1.1.30.2.2.1
Members (24)
Compliance Statements (1)
ieee8021STCompliance .1.3.111.2.802.1.1.30.2.1.1
Dependencies (9) 5 direct · 4 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IEEE8021-TC-MIBrfc
- IANAifType-MIBrfc
- SNMPv2-CONFrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- SNMP-FRAMEWORK-MIBrfc
- IEEE8021-BRIDGE-MIBrfc
- IEEE8021-ST-MIBrfcselected