ICT-PLATINUM-SERIES-MIB

Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity Sensors
Explore Observium network monitoring
Source file
ICT-PLATINUM-SERIES-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises IpAddress
RFC1213-MIB DisplayString
Objects (22)
11 directly used by Observium
.1.3.6.1.4.1.39145
.1.3.6.1.4.1.39145.11
deviceModel OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.1
batteryVoltage mandatory
.1.3.6.1.4.1.39145.11.10
batteryCurrent mandatory
.1.3.6.1.4.1.39145.11.11
batteryTemperature OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.12
batterySoc OBS ✓ mandatory
Integer32
.1.3.6.1.4.1.39145.11.13
batteryNetAh mandatory
.1.3.6.1.4.1.39145.11.14
batteryRunTime OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.15
inputVoltageX1 OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.16
outputVoltageX100 OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.17
outputCurrentX100 OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.18
batteryVoltageX100 OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.19
deviceName mandatory
.1.3.6.1.4.1.39145.11.2
batteryCurrentX100 OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.20
deviceHardware mandatory
Integer32
.1.3.6.1.4.1.39145.11.3
deviceFirmware OBS ✓ mandatory
.1.3.6.1.4.1.39145.11.4
deviceMacAddress mandatory
.1.3.6.1.4.1.39145.11.5
inputVoltage mandatory
.1.3.6.1.4.1.39145.11.6
outputVoltage mandatory
.1.3.6.1.4.1.39145.11.7
outputCurrent mandatory
.1.3.6.1.4.1.39145.11.8
outputEnable OBS ✓ mandatory r/w
Enumeration
.1.3.6.1.4.1.39145.11.9
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. SNMPv2-SMIrfc
  5. SNMPv2-TCrfc
  6. IANAifType-MIBrfc
  7. RFC1213-MIBrfc
  8. ICT-PLATINUM-SERIES-MIBictselected
Notifications / Traps (20)
NameOIDDescription
.1.3.6.1.4.1.39145.11.0.101
Trap generated when the AC Failure Alarm is triggered
.1.3.6.1.4.1.39145.11.0.102
Trap generated when the DC Failure Alarm is triggered
.1.3.6.1.4.1.39145.11.0.103
Trap generated when the System Failure Alarm is triggered
.1.3.6.1.4.1.39145.11.0.104
Trap generated when the Over-Temperature Alarm is triggered
.1.3.6.1.4.1.39145.11.0.105
Trap generated when communications lost with a Parallel Unit
.1.3.6.1.4.1.39145.11.0.106
Trap generated when the Fan Failure Alarm is triggered
.1.3.6.1.4.1.39145.11.0.107
Trap generated when a Battery Alarm is triggered
.1.3.6.1.4.1.39145.11.0.108
Trap generated when the Battery Overcurrent Alarm is triggered
.1.3.6.1.4.1.39145.11.0.111
Trap generated when the AC Failure Alarm is cleared
.1.3.6.1.4.1.39145.11.0.112
Trap generated when the DC Failure Alarm is cleared
.1.3.6.1.4.1.39145.11.0.113
Trap generated when the System Failure Alarm is cleared
.1.3.6.1.4.1.39145.11.0.114
Trap generated when the Over-Temperature Alarm is cleared
.1.3.6.1.4.1.39145.11.0.115
Trap generated when the Communications Failure Alarm is cleared
.1.3.6.1.4.1.39145.11.0.116
Trap generated when the Fan Failure Alarm is cleared
.1.3.6.1.4.1.39145.11.0.117
Trap generated when the Battery Alarm is cleared
.1.3.6.1.4.1.39145.11.0.121
Trap generated when a Battery Discharge Test is started
.1.3.6.1.4.1.39145.11.0.122
Trap generated when a Battery Discharge Test completes successfully
.1.3.6.1.4.1.39145.11.0.123
Trap generated when a Battery Discharge Test fails
.1.3.6.1.4.1.39145.11.0.124
Trap generated when a Battery Equalize Charge is started
.1.3.6.1.4.1.39145.11.0.125
Trap generated when a Battery Equalize Charge completes