ICT-DISTRIBUTION-PANEL-MIB

Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Explore Observium network monitoring
Source file
ICT-DISTRIBUTION-PANEL-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises IpAddress
RFC1213-MIB DisplayString
Objects (27)
1 directly used by Observium
.1.3.6.1.4.1.39145
.1.3.6.1.4.1.39145.10
deviceModel mandatory
.1.3.6.1.4.1.39145.10.1
busTable mandatory
.1.3.6.1.4.1.39145.10.10
busEntry mandatory
.1.3.6.1.4.1.39145.10.10.1
busNumber mandatory
Integer32
.1.3.6.1.4.1.39145.10.10.1.1
busName mandatory
.1.3.6.1.4.1.39145.10.10.1.2
busVoltage mandatory
.1.3.6.1.4.1.39145.10.10.1.3
busCurrent mandatory
.1.3.6.1.4.1.39145.10.10.1.4
deviceName mandatory
.1.3.6.1.4.1.39145.10.2
deviceHardware mandatory
Integer32
.1.3.6.1.4.1.39145.10.3
deviceFirmware mandatory
.1.3.6.1.4.1.39145.10.4
deviceMacAddress mandatory
.1.3.6.1.4.1.39145.10.5
systemVoltage mandatory
.1.3.6.1.4.1.39145.10.6
systemCurrent mandatory
.1.3.6.1.4.1.39145.10.7
outputTable mandatory
.1.3.6.1.4.1.39145.10.8
outputEntry mandatory
.1.3.6.1.4.1.39145.10.8.1
outputNumber mandatory
Integer32
.1.3.6.1.4.1.39145.10.8.1.1
outputName mandatory
.1.3.6.1.4.1.39145.10.8.1.2
outputCurrent OBS ✓ mandatory
.1.3.6.1.4.1.39145.10.8.1.3
outputFuseStatus mandatory
Enumeration
.1.3.6.1.4.1.39145.10.8.1.4
outputEnable mandatory r/w
Enumeration
.1.3.6.1.4.1.39145.10.8.1.5
alarmTable mandatory
.1.3.6.1.4.1.39145.10.9
alarmEntry mandatory
.1.3.6.1.4.1.39145.10.9.1
alarmNumber mandatory
Integer32
.1.3.6.1.4.1.39145.10.9.1.1
alarmName mandatory
.1.3.6.1.4.1.39145.10.9.1.2
alarmStatus mandatory
Enumeration
.1.3.6.1.4.1.39145.10.9.1.3
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. SNMPv2-SMIrfc
  5. SNMPv2-TCrfc
  6. IANAifType-MIBrfc
  7. RFC1213-MIBrfc
  8. ICT-DISTRIBUTION-PANEL-MIBictselected
Notifications / Traps (16)
NameOIDDescription
.1.3.6.1.4.1.39145.10.0.101
Trap generated when a System/Bus Undervoltage Alarm is triggered
.1.3.6.1.4.1.39145.10.0.102
Trap generated when a System/Bus Overvoltage Alarm is triggered
.1.3.6.1.4.1.39145.10.0.103
Trap generated when a System/Bus Overcurrent Alarm is triggered
.1.3.6.1.4.1.39145.10.0.104
Trap generated when an Output Fuse Alarm is triggered
.1.3.6.1.4.1.39145.10.0.105
Trap generated when an Output Undercurrent Alarm is triggered
.1.3.6.1.4.1.39145.10.0.106
Trap generated when an Output Overcurrent Alarm is triggered
.1.3.6.1.4.1.39145.10.0.107
Trap generated when Load-Shedding is activated on an Output
.1.3.6.1.4.1.39145.10.0.108
Trap generated when an Alarm Input is activated
.1.3.6.1.4.1.39145.10.0.111
Trap generated when a System/Bus Undervoltage Alarm is cleared
.1.3.6.1.4.1.39145.10.0.112
Trap generated when a System/Bus Overvoltage Alarm is cleared
.1.3.6.1.4.1.39145.10.0.113
Trap generated when a System/Bus Overcurrent Alarm is cleared
.1.3.6.1.4.1.39145.10.0.114
Trap generated when an Output Fuse Alarm is cleared
.1.3.6.1.4.1.39145.10.0.115
Trap generated when an Output Undercurrent Alarm is cleared
.1.3.6.1.4.1.39145.10.0.116
Trap generated when an Output Overcurrent Alarm is cleared
.1.3.6.1.4.1.39145.10.0.117
Trap generated when an Output has recovered from a Load-Shedding condition
.1.3.6.1.4.1.39145.10.0.118
Trap generated when an Alarm Input is cleared