IBM-PDU-MIB
Monitored by Observium The MIB module representing a power disribution
unit supported by a single SNMP agent
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity
Sensors
Status
System information
Explore Observium network monitoring
- Source file
IBM-PDU-MIB- Last revised
- Identity
ibmPowerDistributionUnitMIB- Base OID
1.3.6.1.4.1.2.6.223
Imported Objects
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION (no object page) |
Net-SNMP examples using the ibm MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'IBM-PDU-MIB' -M '/opt/observium/mibs/ibm:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IBM-PDU-MIB::ibmPowerDistributionUnitMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IBM-PDU-MIB' -M '/opt/observium/mibs/ibm:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IBM-PDU-MIB::ibmPowerDistributionUnitMIB'
Objects (102)
17 directly used by Observium
Showing 102 of 102 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.2 | ||
.1.3.6.1.4.1.2.6 | ||
| ibmPowerDistributionUnitMIB | .1.3.6.1.4.1.2.6.223 | |
.1.3.6.1.4.1.2.6.223.0 | ||
.1.3.6.1.4.1.2.6.223.0.1.1 | ||
| ibmPduObjectIndex | Unsigned32 | .1.3.6.1.4.1.2.6.223.0.1.1.1 |
| ibmPduObjectType | Enumeration | .1.3.6.1.4.1.2.6.223.0.1.1.2 |
| ibmPduObjectID | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2.6.223.0.1.1.3 |
| ibmPduSeverity | Enumeration | .1.3.6.1.4.1.2.6.223.0.1.1.4 |
| ibmPduTrapDescription | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2.6.223.0.1.1.5 |
| ibmPduState | Enumeration | .1.3.6.1.4.1.2.6.223.0.1.1.6 |
| ibmPduVoltageWarning | Enumeration | .1.3.6.1.4.1.2.6.223.0.1.1.7 |
.1.3.6.1.4.1.2.6.223.2 | ||
.1.3.6.1.4.1.2.6.223.2.1 | ||
.1.3.6.1.4.1.2.6.223.2.2 | ||
| ibmPduBufferTagValue | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.3 |
| ibmPduSampleRate | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.4 |
| ibmPduBufferVersion | OctetString | .1.3.6.1.4.1.2.6.223.5 |
| ibmPduBufferEntries | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.6 |
.1.3.6.1.4.1.2.6.223.7 | ||
.1.3.6.1.4.1.2.6.223.7.1 | ||
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.1 | |
ibmPduRowr/w | OctetString | .1.3.6.1.4.1.2.6.223.7.1.10 |
ibmPduAisler/w | OctetString | .1.3.6.1.4.1.2.6.223.7.1.11 |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.7.1.12 | |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.7.1.13 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.14 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.2 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.3 | |
ibmPduCityr/w | OctetString | .1.3.6.1.4.1.2.6.223.7.1.4 |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.5 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.6 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.7 | |
ibmPduFloorr/w | OctetString | .1.3.6.1.4.1.2.6.223.7.1.8 |
| OctetString | .1.3.6.1.4.1.2.6.223.7.1.9 | |
| OctetString | .1.3.6.1.4.1.2.6.223.7.10 | |
| ibmPduUrlOBS ✓ | OctetString | .1.3.6.1.4.1.2.6.223.7.11 |
ibmPduRebootr/w | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.7.12 |
.1.3.6.1.4.1.2.6.223.7.13 | ||
.1.3.6.1.4.1.2.6.223.7.2 | ||
| ibmPduLogo | OctetString | .1.3.6.1.4.1.2.6.223.7.2.1 |
| ibmPduDeviceFront | OctetString | .1.3.6.1.4.1.2.6.223.7.2.2 |
| ibmPduDeviceRear | OctetString | .1.3.6.1.4.1.2.6.223.7.2.3 |
| ibmPduSoftwareVersionOBS ✓ | OctetString | .1.3.6.1.4.1.2.6.223.7.3 |
| ibmPduMachineType | OctetString | .1.3.6.1.4.1.2.6.223.7.4 |
| ibmPduModelNumberOBS ✓ | OctetString | .1.3.6.1.4.1.2.6.223.7.5 |
| ibmPduPartNumber | OctetString | .1.3.6.1.4.1.2.6.223.7.6 |
ibmPduNamer/w | OctetString | .1.3.6.1.4.1.2.6.223.7.7 |
| ibmPduManufacturerOBS ✓ | OctetString | .1.3.6.1.4.1.2.6.223.7.8 |
| ibmPduSerialNumberOBS ✓ | OctetString | .1.3.6.1.4.1.2.6.223.7.9 |
.1.3.6.1.4.1.2.6.223.8 | ||
.1.3.6.1.4.1.2.6.223.8.2 | ||
| ibmPduOutletCount | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2.6.223.8.2.1 |
| ibmPduOutletTable | .1.3.6.1.4.1.2.6.223.8.2.2 | |
| ibmPduOutletEntry | .1.3.6.1.4.1.2.6.223.8.2.2.1 | |
| ibmPduOutletNumber | Integer32 | .1.3.6.1.4.1.2.6.223.8.2.2.1.1 |
| ibmPduOutletMaxCapacity | IbmPduMilliAmps | .1.3.6.1.4.1.2.6.223.8.2.2.1.10 |
| IbmPduMilliAmps | .1.3.6.1.4.1.2.6.223.8.2.2.1.11 | |
| IbmPduMilliAmps | .1.3.6.1.4.1.2.6.223.8.2.2.1.12 | |
ibmPduOutletStateOBS ✓r/w | Enumeration | .1.3.6.1.4.1.2.6.223.8.2.2.1.13 |
| ibmPduOutletGroupIndex | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.2.2.1.14 |
| ibmPduOutletLastPowerReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.2.2.1.15 |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.2.2.1.16 | |
| OctetString | .1.3.6.1.4.1.2.6.223.8.2.2.1.2 | |
| ibmPduOutletType | Enumeration | .1.3.6.1.4.1.2.6.223.8.2.2.1.3 |
| OctetString | .1.3.6.1.4.1.2.6.223.8.2.2.1.4 | |
| ibmPduOutletAvgPower | IbmPduPowerBuf | .1.3.6.1.4.1.2.6.223.8.2.2.1.5 |
| ibmPduOutletMaxPower | IbmPduPowerBuf | .1.3.6.1.4.1.2.6.223.8.2.2.1.6 |
| ibmPduOutletPowerFactorOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.2.2.1.7 |
| ibmPduOutletVoltageOBS ✓ | IbmPduMilliVolt | .1.3.6.1.4.1.2.6.223.8.2.2.1.8 |
| ibmPduOutletCurrentOBS ✓ | IbmPduMilliAmps | .1.3.6.1.4.1.2.6.223.8.2.2.1.9 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2.6.223.8.2.3 | |
.1.3.6.1.4.1.2.6.223.8.3 | ||
| ibmPduPhaseCount | Enumeration | .1.3.6.1.4.1.2.6.223.8.3.1 |
| ibmPduPhaseTable | .1.3.6.1.4.1.2.6.223.8.3.2 | |
| ibmPduPhaseTableEntry | .1.3.6.1.4.1.2.6.223.8.3.2.1 | |
| ibmPduPhaseNumber | Unsigned32 | .1.3.6.1.4.1.2.6.223.8.3.2.1.1 |
| ibmPduPhaseAvgPower | IbmPduPowerBuf | .1.3.6.1.4.1.2.6.223.8.3.2.1.2 |
| ibmPduPhaseMaxPower | IbmPduPowerBuf | .1.3.6.1.4.1.2.6.223.8.3.2.1.3 |
| ibmPduPhaseLastPowerReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.3.2.1.4 |
.1.3.6.1.4.1.2.6.223.8.4 | ||
| ibmPduThermalBuffer | IbmPduEnvBuf | .1.3.6.1.4.1.2.6.223.8.4.1 |
| ibmPduHumidityBuffer | IbmPduEnvBuf | .1.3.6.1.4.1.2.6.223.8.4.2 |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.4.3 | |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.4.4 | |
| Unsigned32 | .1.3.6.1.4.1.2.6.223.8.4.5 | |
| Unsigned32 | .1.3.6.1.4.1.2.6.223.8.4.6 | |
| ibmPduThermalLastReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.4.7 |
| ibmPduHumidityLastReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.8.4.8 |
.1.3.6.1.4.1.2.6.223.9 | ||
| ibmPduExtMonitorCountOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2.6.223.9.1 |
| ibmPduExtMonitorTable | .1.3.6.1.4.1.2.6.223.9.2 | |
| ibmPduExtMonitorEntry | .1.3.6.1.4.1.2.6.223.9.2.1 | |
| ibmPduExtMonitorNumberOBS ✓ | Integer32 | .1.3.6.1.4.1.2.6.223.9.2.1.1 |
| ibmPduExtThermalBuffer | IbmPduEnvBuf | .1.3.6.1.4.1.2.6.223.9.2.1.2 |
| ibmPduExtHumidityBuffer | IbmPduEnvBuf | .1.3.6.1.4.1.2.6.223.9.2.1.3 |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.4 | |
| SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.5 | |
| Unsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.6 | |
| Unsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.7 | |
| ibmPduExtThermalLastReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.8 |
| ibmPduExtHumidityLastReadingOBS ✓ | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2.6.223.9.2.1.9 |
Dependencies (3) 3 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- IBM-PDU-MIBibmselected
Type Definitions (4)
| OctetString |
range: 240 |
|
| Unsigned32 | ||
| Unsigned32 | ||
| OctetString |
range: 480 |
Conformance Groups (7)
Compliance Statements (1)
OID
.1.3.6.1.4.1.2.6.223.2.1.8The requirements for conformance to the PDU-MIB.
Required groups
| mandatory | ibmPduDeviceGroup | |
| mandatory | ibmPduLocationGroup | |
| mandatory | ibmPduImageGroup | |
| mandatory | ibmPduOutletGroup | |
| mandatory | ibmPduExtMonitorGroup | |
| mandatory | ibmPduTrapDataGroup | |
| mandatory | ibmPduTrapGroup |
Notifications / Traps (7)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.2.6.223.0.1 |
Threshold for Current events set by the user.
|
|
.1.3.6.1.4.1.2.6.223.0.2 |
Threshold for thermal events set by the user.
|
|
.1.3.6.1.4.1.2.6.223.0.3 |
Threshold for humidity events set by the user.
|
|
.1.3.6.1.4.1.2.6.223.0.4 |
Outlet state has changed.
|
|
.1.3.6.1.4.1.2.6.223.0.5 |
PDU firmware has been updated.
|
|
.1.3.6.1.4.1.2.6.223.0.6 |
Device state has changed.
|
|
.1.3.6.1.4.1.2.6.223.0.7 |
AC Voltage +/- 15% Normal.
|