HUAWEI-SPC-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
93
.1.3.6.1.4.1.2011.6.15.1.1 · 1 row entry · 67 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk hwSpcMngtTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-SPC-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-SPC-MIB::hwSpcMngtTable'
You can add, delete, modify or query SPC using hwSpcMngtTable.
The index of this table is hwSpcNo.
hwSpcMngtEntry row .1.3.6.1.4.1.2011.6.15.1.1.1
You can add, delete, modify or query SPC using hwSpcMngtTable.
The index of this entry is hwSpcNo.
Indexes
Column Syntax OID
Index of the SPC
Range: 0-2047 for MD products and 0-511 for MA products
Integer32
Constraints:
range: 0-2099
.1.3.6.1.4.1.2011.6.15.1.1.1.1
Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.1.1.2
Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.1.1.3
Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.1.1.4
Channel index of SPC's start point
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.1.1.5
Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.1.1.6
Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.1.1.7
Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.1.1.8
Channel index of SPC's end point.
The value 255 indicates that this parameter is not used.
Integer32r/w
Constraints:
range: 255-255
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.1.1.9
Total channels occupied by the SPC.
Integer32r/w
Constraints:
range: 1-32
.1.3.6.1.4.1.2011.6.15.1.1.1.10
Applied type of SPC.
Options:
1. normal(1) -normal application
2. hotline(2) -hotline application
3. mChannelTransparent(3) -M channel transparent
4. pBX-extention(4) -Z interface extension
5. pBX-bothway(5) -PBX bothwa…
Enumerationr/w
Enumerated Values:
1normal
2hotline
3mChannelTransparent
4pBX-extention
5pBX-bothway
6e1-DDI
7t1-DDI
8eM-signal
.1.3.6.1.4.1.2011.6.15.1.1.1.11
Configuration type of SPC.
Options:
1. anSpc(1) -Internal SPC
2. v5Spc(2) -V5 SPC
3. v5Preconnect(3) -V5 pre-connection SPC
4. private(4) -leased line SPC
5. ipspc(5) -IP SPC
6. confspc(6) -conference SPC
Enumerationr/w
Enumerated Values:
1anSpc
2v5Spc
3v5Preconnect
4private
5ipspc
6confspc
.1.3.6.1.4.1.2011.6.15.1.1.1.12
Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt
Enumerationr/w
Enumerated Values:
1mnt
2mlt
255noSubType
.1.3.6.1.4.1.2011.6.15.1.1.1.13
Sub type of SPC's end port.
This node is not used on the OLT.
Options:
1. noSubType(255) -no sub type
2. mnt(1) -mnt
3. mlt(2) -mlt
Enumerationr/w
Enumerated Values:
1mnt
2mlt
255noSubType
.1.3.6.1.4.1.2011.6.15.1.1.1.14
Enable path protection. This leaf is not used on the OLT.
Options:
1. yes(1) -YES
2. no(2) -NO
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.2011.6.15.1.1.1.15
Name of SPC. It contains 31 characters.
- means it is not configured.
OctetStringr/w
Constraints:
range: 1-31
.1.3.6.1.4.1.2011.6.15.1.1.1.16
SPC state.
Options:
1. idle(1) -idle
2. normal(2) -normal
3. error(3) -error
4. errorChecking(4) -error checking
5. occupying(5) -occupying
6. checking(6) -checking
7. released(7) -released
8. errReleasing(8) -error rel…
Enumeration
Enumerated Values:
1idle
2normal
3error
4errorChecking
5occupying
6checking
7released
8errReleasing
9refreshReleasing
10disconnecting
.1.3.6.1.4.1.2011.6.15.1.1.1.17
Fault reason of SPC.
Options:
1. startBusy(1) -the start port is busy
2. endBusy(2) - the end port is busy
3. startFault(3) - the start port is fault
4. endFault(4) - the end port is fault
5. startLoop(5) - the start po…
Enumeration
Enumerated Values:
1startBusy
2endBusy
3startFault
4endFault
5startLoop
6endLoop
7startLock
8endLock
9resNotEnough
10waitingTimeout
11startTest
12endTest
13noAlarm
14noTS
15noLicense
16linksetFault
17portUnactive
.1.3.6.1.4.1.2011.6.15.1.1.1.18
Operate type of SPC. It can be set to disconnect or connect.
Options:
1. noOperation(1) -no operation
2. connect(2) -connect
3. disconnect(3) -disconnect
Enumerationr/w
Enumerated Values:
1noOperation
2connect
3disconnect
.1.3.6.1.4.1.2011.6.15.1.1.1.19
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.2011.6.15.1.1.1.20
Start CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.21
CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.22
Start CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.23
Start upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.24
Start upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.25
Start upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.26
Start downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.27
Start downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.28
Start downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.29
Start downstream RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.30
Start downstream RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.31
Start downstream RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.32
End downstream CES shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.33
End downstream CES slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.34
End CES port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.35
End upstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.36
End upstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.37
End upstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.38
End downstream PV8 shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.39
End downstream PV8 slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.40
End downstream PV8 port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.41
End RSP shelf.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.42
End RSP slot.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.43
End RSP port.
If the value is 255, it indicates that the SPC does not use this path.
This leaf is not used on the OLT.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2011.6.15.1.1.1.44
Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.2011.6.15.1.1.1.45
Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.46
Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.2011.6.15.1.1.1.47
Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.48
Voice codec type of the SPC.
Options:
1. acG711Malaw(1) -G.711A
2. acG711Mulaw(2) -G.711U
3. acG723Low(3) -G.723low
4. acG723High(4) -G.723high
5. acG729(5) -G.729
6. clearMode(6) -clear mode
7. g72616k(7) -…
Enumerationr/w
Enumerated Values:
-1invalid
1acG711Malaw
2acG711Mulaw
3acG723Low
4acG723High
5acG729
6clearMode
7g72616k
8g72624k
9g72632k
10g72640k
11g722
.1.3.6.1.4.1.2011.6.15.1.1.1.49
The switch of EC.
Options:
1. disable(1) -disable EC
2. enable(2) -enable EC
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1disable
2enable
.1.3.6.1.4.1.2011.6.15.1.1.1.50
The switch of SC.
Options:
1. disable(1) -disable SC
2. enable(2) -enable SC
3. invalid(-1) -invalid value
Enumerationr/w
Enumerated Values:
-1invalid
1disable
2enable
.1.3.6.1.4.1.2011.6.15.1.1.1.51
RTP sampling time.
Options:
1. five(1) -5 ms
2. ten(2) -10 ms
3. twenty(3) -20 ms
4. thirty(4) -30 ms
5. invalid(255) -invalid value
Unit: millisecond
Enumerationr/w
Enumerated Values:
1five
2ten
3twenty
4thirty
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.52
The switch of PLC.
Options:
1. enable(1) -enable PLC
2. disable(2) -disable PLC
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1enable
2disable
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.53
The switch of 2198.
Options:
1. enable(1) -enable RFC2198 redundancy
2. disable(2) -disable RFC2198 redundancy
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1enable
2disable
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.54
Jitterbuffer mode.
Options:
1. adapt(1) -adapt
2. fixed(2) -fixed
3. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1adapt
2fixed
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.55
DSP work mode.
Options:
1. voice(1) -voice
2. fax(2) -fax
3. modem(3) -modem
4. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1voice
2fax
3modem
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.56
Connect mode.
Options:
1. sendReceive(1) -send and receive
2. sendOnly(2) -send only
3. receiveOnly(3) -receive only
4. invalid(255) -invalid value
Enumerationr/w
Enumerated Values:
1sendReceive
2sendOnly
3receiveOnly
255invalid
.1.3.6.1.4.1.2011.6.15.1.1.1.57
The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.58
IUA link set number.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA link set number.
Integer32r/w
Constraints:
range: -1-31
.1.3.6.1.4.1.2011.6.15.1.1.1.59
IUA interface ID.
In the case of the U interface transparent, this parameter must be configured.
If the value is -1, it indicates that the SPC does not use the IUA interface ID.
Integer32r/w
Constraints:
range: -1-65535
.1.3.6.1.4.1.2011.6.15.1.1.1.60
Conference Group ID.
This leaf is not used on the OLT.
Integer32r/w
Constraints:
range: 0-15
.1.3.6.1.4.1.2011.6.15.1.1.1.61
Information of B1 DSP in conference service or BRA IP service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID.
This leaf is not used on the OLT.
OctetString
Constraints:
range: 9-32
.1.3.6.1.4.1.2011.6.15.1.1.1.62
Information of B2 DSP in BRA ip service.
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID
This leaf is not used on OLT.
OctetString
Constraints:
range: 9-32
.1.3.6.1.4.1.2011.6.15.1.1.1.63
Signal type of IP SPC.
Options:
1. 1 - normal
2. 2 - 2833
This leaf is only used on the UA5000.
Integer32r/w
Constraints:
range: 1-2
.1.3.6.1.4.1.2011.6.15.1.1.1.64
IP SPC initial ring type.
Enumeration type:
1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK) 1.2:2, 6-HK ring (FSK) 1:3, 7-HK CNTRX (FSK) 0.4:0.2:0.4:0…
Integer32r/w
Constraints:
range: 1-27
.1.3.6.1.4.1.2011.6.15.1.1.1.65
IP SPC cadence ring type.
Enumerated types:
1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-HK ring 1:3, 8-HK CNTRX 0.4:0.2:0.4:0.2:0.4:3.0,
9-HK DN-A 0…
Integer32r/w
Constraints:
range: 1-30
.1.3.6.1.4.1.2011.6.15.1.1.1.66
IP SPC 2833 payload type.
This leaf is only used on the UA5000.
Integer32r/w
Constraints:
range: 96-127
.1.3.6.1.4.1.2011.6.15.1.1.1.67
.1.3.6.1.4.1.2011.6.15.1.4 · 1 row entry · 5 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk hwSpcProtectGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-SPC-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-SPC-MIB::hwSpcProtectGroupTable'
You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
The index of this table is hwSpcProtectGroupID.
hwSpcProtectGroupEntry row .1.3.6.1.4.1.2011.6.15.1.4.1
You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
The index of this entry is hwSpcProtectGroupID.
Column Syntax OID
Index of the SPC E1 protect group.
Range: 0-2 for UA products.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.2011.6.15.1.4.1.1
Frame ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.4.1.2
Slot ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.4.1.3
Port ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.4.1.4
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.2011.6.15.1.4.1.5
.1.3.6.1.4.1.2011.6.15.1.5 · 1 row entry · 8 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk hwSpcProtectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-SPC-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-SPC-MIB::hwSpcProtectTable'
You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
The index of this table is hwSpcProtectID.
hwSpcProtectEntry row .1.3.6.1.4.1.2011.6.15.1.5.1
You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
The index of this entry is hwSpcProtectID.
Indexes
Column Syntax OID
Index of the SPC E1 protect link.
Range: 0-8 for UA products.
Integer32
Constraints:
range: 0-8
.1.3.6.1.4.1.2011.6.15.1.5.1.1
Index of the SPC E1 protect group.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.2011.6.15.1.5.1.2
Frame ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.5.1.3
Slot ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.5.1.4
Port ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-63
.1.3.6.1.4.1.2011.6.15.1.5.1.5
Priority of SPC E1 protect link. 1: cat1(1), 2: cat1(2), 3: cat1(3).
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.2011.6.15.1.5.1.6
State of the SPC E1 protect link.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.2011.6.15.1.5.1.7
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.2011.6.15.1.5.1.8
.1.3.6.1.4.1.2011.6.15.1.6 · 1 row entry · 13 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk hwSubRateSwitchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-SPC-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-SPC-MIB::hwSubRateSwitchTable'
You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
The index of this table is hwSubRateSwitchID.
hwSubRateSwitchEntry row .1.3.6.1.4.1.2011.6.15.1.6.1
You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
The index of this entry is hwSubRateSwitchID.
Column Syntax OID
Index of the sub-rate switch
Integer32
Constraints:
range: 0-1023
.1.3.6.1.4.1.2011.6.15.1.6.1.1
Frame ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.6.1.2
Slot ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.6.1.3
Port ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.4
Channel index of sub-rate switch start point
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.5
sub-rate channel index of sub-rate switch start point
Integer32r/w
Constraints:
range: 0-19
.1.3.6.1.4.1.2011.6.15.1.6.1.6
Frame ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-97
.1.3.6.1.4.1.2011.6.15.1.6.1.7
Slot ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-35
.1.3.6.1.4.1.2011.6.15.1.6.1.8
Port ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.9
Channel index of sub-rate switch end point.
Integer32r/w
Constraints:
range: 0-31
.1.3.6.1.4.1.2011.6.15.1.6.1.10
sub-rate channel index of sub-rate switch end point.
Integer32r/w
Constraints:
range: 0-19
.1.3.6.1.4.1.2011.6.15.1.6.1.11
sub-rate switch state.
Options:
1. fault(1) -fault
2. normal(2) -normal
Enumeration
Enumerated Values:
1fault
2normal
.1.3.6.1.4.1.2011.6.15.1.6.1.12
Row status. It supports only CreateAndGo(4) and Destroy(6).
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.2011.6.15.1.6.1.13