HPVCMODULE-MIB
This MIB module describes module specific MIB objects present in each of the
Virtual Connect Ethernet (VC-Enet) Modules. These objects represent
information about individual VC-Enet modules irrespective of its VC domain
role.
vcModuleMIB
1.3.6.1.4.1.11.5.7.5.2.3
Imported Objects
| IF-MIB | ifIndex ifInErrors ifOutErrors InterfaceIndex |
| RFC1155-SMI | enterprises |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 zeroDotZero |
| SNMPv2-TC | RowPointer TEXTUAL-CONVENTION TruthValue |
| TRANSPORT-ADDRESS-MIB | TransportAddress TransportAddressType |
Type Definitions (5)
| VcEnclosureRole | Enumeration |
unknown(1)primary(2)secondary(3) |
| VcModulePortBpduLoopStatus | Enumeration |
ok(1)loop-detected(2) |
| VcModulePortProtectionStatus | Enumeration |
ok(1)pause-flood-detected(2)in-pause-condition(3) |
| VcModuleRole | Enumeration |
unintegrated(1)primaryProtected(2)primaryUnprotected(3)standby(4)other(5) |
| VcModuleType | Enumeration |
vcModuleEnet(1)vcModuleFC(2)vcModuleOther(3) |
Objects (28)
|
|
.1.3.6.1.4.1.11 |
|
|
|
.1.3.6.1.4.1.11.5 |
|
|
|
.1.3.6.1.4.1.11.5.7 |
|
|
|
.1.3.6.1.4.1.11.5.7.5 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.1 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.1.1 |
|
|
|
SNMP-FRAMEWORK-MIBSnmpAdminString | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.1 |
|
|
VcModuleRole | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.2 |
|
|
TRANSPORT-ADDRESS-MIBTransportAddressType | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.3 |
|
|
TRANSPORT-ADDRESS-MIBTransportAddress | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.4 |
|
|
VcEnclosureRole | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.5 |
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.1.1.6 |
|
|
|
vcModulePort | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1 |
|
|
Integer32 | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.1 |
|
|
IF-MIBInterfaceIndex | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.2 |
|
|
VcModulePortBpduLoopStatus | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.3 |
|
|
VcModulePortProtectionStatus | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.4 |
|
|
TRANSPORT-ADDRESS-MIBTransportAddress | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.7 |
|
|
SNMPv2-SMICounter32 | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.8 |
|
|
SNMPv2-SMICounter32 | .1.3.6.1.4.1.11.5.7.5.2.3.1.1.9 |
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.1 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.3 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.3.1 |
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.3.2 |
Notifications / Traps (15)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.1 |
The VCM role of the VC module has changed. |
|
IF-MIBifIndex
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.11 |
The port input utilization rate has exceeded high threshold.
The input line utilization on a port has exceeded its threshold
for longer than the threshold averaging period. The ifIndex
is the index of the affected port in ifTable.
|
|
IF-MIBifIndex
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.12 |
The port input utilization rate has dropped below low watermark.
The input line utilization on a port has dropped below its low
watermark for longer than the threshold averaging period. The ifIndex
is the index of the affected port in ifTable.
|
|
IF-MIBifIndex
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.13 |
The port output utilization rate has exceeded high threshold.
The output line utilization on a port has exceeded its high watermark
for longer than the threshold averaging period. The ifIndex
is the index of the affected port in ifTable.
|
|
IF-MIBifIndex
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.14 |
The port output utilization rate has dropped below low watermark.
The output line utilization on a port has dropped below its low watermark
for longer than the threshold averaging period. The ifIndex
is the index of the affected port in ifTable.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.15 |
The input error count on a port has exceeded high watermark.
The input error count on a port has exceeded its high watermark for
longer than the error averaging period. The port is identified by
ifIndex in ifTable.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.16 |
The input error count on a port has dropped below low watermark.
The input error count on a port has dropped below its low watermark for
longer than the error averaging period. The port is identified by
ifIndex in ifTable.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.17 |
The output error count on a port has exceeded its high watermark.
The output error count on a port has exceeded its high watermark for
longer than the error averaging period. The port is identified by
ifIndex in ifTable.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.18 |
The output error count on a port has dropped below its low watermark.
The output error count on a port has dropped below its low watermark for
longer than the error averaging period. The port is identified by
ifIndex in ifTable.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.19 |
A BPDU loop condition is detected on this port.
If the port is configured for loop protection, the port is
disabled to protect against network loops. The port remains disabled
until administrative action is taken.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.2 |
The switch hardware has detected a parity error. The parity error is automatically corrected. |
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.20 |
A previous BPDU loop condition is cleared.
This trap is only sent when the agent detects transition from 'loop
detected' state to 'ok' state on a given port.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.21 |
A port protection condition is detected on this port.
If the new port protection status is a value other than ok,
the port may be disabled to protect the VC module from further
service degradation.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.22 |
Port is recovered from port protection condition.
The port is recovered from port protection condition to normal
operational state.
|
|
|
.1.3.6.1.4.1.11.5.7.5.2.3.2.0.3 |
The switch hardware has detected a parity/ECC error. The parity/ecc error is non Correctable. cpqHoFwVerLocation identifies the Rack, Enclosurename and Bay number where the parity/ecc error occured. cpqHoFwVerLocation is represented in <RackName>:<EnclosureName>:<Bay Number> format |