.1.3.6.1.4.1.248.14.1.13.1.2
·
1 row entry
·
4 columns
Uses the hirschmann variant from
Command help
/opt/observium/mibs/hirschmann.
Walk hmIOModConfigDigInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HMIOMODULE-SNMP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HMIOMODULE-SNMP-MIB::hmIOModConfigDigInputTable'
IO module config table for inputs
IO module config entry for inputs
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hmIOModConfigDigInputModIDThe module ID of an input. | Integer32 Constraints: range: 1-7 | .1.3.6.1.4.1.248.14.1.13.1.2.1.1 | ||||
| hmIOModConfigDigInputIDThe ID of an input. | Integer32 Constraints: range: 1-4 | .1.3.6.1.4.1.248.14.1.13.1.2.1.2 | ||||
| hmIOModConfigDigInputLogEventTrigger an event log when input status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the input state changes. The input sta… | HmEnabledStatusr/w Type Values:
| .1.3.6.1.4.1.248.14.1.13.1.2.1.3 | ||||
| hmIOModConfigDigInputSnmpTrapTrigger an SNMP trap log when input status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sent when the input state changes. The SNMP trap will be sent t… | HmEnabledStatusr/w Type Values:
| .1.3.6.1.4.1.248.14.1.13.1.2.1.4 |
.1.3.6.1.4.1.248.14.1.13.1.3
·
1 row entry
·
8 columns
Uses the hirschmann variant from
Command help
/opt/observium/mibs/hirschmann.
Walk hmIOModConfigDigOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HMIOMODULE-SNMP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HMIOMODULE-SNMP-MIB::hmIOModConfigDigOutputTable'
IO module config table for outputs
IO module config entry for outputs
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hmIOModConfigDigOutputModIDThe module ID of an output. | Integer32 Constraints: range: 1-7 | .1.3.6.1.4.1.248.14.1.13.1.3.1.1 | ||||
| hmIOModConfigDigOutputIDThe ID of an output. | Integer32 Constraints: range: 1-4 | .1.3.6.1.4.1.248.14.1.13.1.3.1.2 | ||||
| hmIOModConfigDigOutputLogEventTrigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the output state changes. The output … | HmEnabledStatusr/w Type Values:
| .1.3.6.1.4.1.248.14.1.13.1.3.1.3 | ||||
| hmIOModConfigDigOutputSnmpTrapTrigger an SNMP trap log when output status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sent when the output state changes. The SNMP trap will be sent… | HmEnabledStatusr/w Type Values:
| .1.3.6.1.4.1.248.14.1.13.1.3.1.4 | ||||
| hmIOModConfigDigOutputSourceIPThe IP address of an input mirrored to the output. Use 0.0.0.0 if the output should not be set. In this case hmIOModOutputValue is invalid (3). Use 127.0.0.1 if an local input should be used. | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.248.14.1.13.1.3.1.5 | ||||
| hmIOModConfigDigOutputSourceModIDThe module ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0. | Integer32r/w Constraints: range: 1-7 | .1.3.6.1.4.1.248.14.1.13.1.3.1.6 | ||||
| hmIOModConfigDigOutputSourceIDThe ID of an input mirrored to the output. Ignored when hmIOModConfigDigOutputSourceIP is 0.0.0.0. | Integer32r/w Constraints: range: 1-4 | .1.3.6.1.4.1.248.14.1.13.1.3.1.7 | ||||
| hmIOModConfigDigOutputSourcePortThe SNMP port number being used by the input mirrored to the output. This port would be the destination for the SNMP requests for polling the state of the input. | INET-ADDRESS-MIBInetPortNumberr/w Type Constraints: range: 0..65535 | .1.3.6.1.4.1.248.14.1.13.1.3.1.8 |
.1.3.6.1.4.1.248.14.1.13.2.1
·
1 row entry
·
3 columns
Uses the hirschmann variant from
Command help
/opt/observium/mibs/hirschmann.
Walk hmIOModValueDigInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HMIOMODULE-SNMP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HMIOMODULE-SNMP-MIB::hmIOModValueDigInputTable'
IO module value table for inputs
IO module value entry for inputs
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| hmIOModValueDigInputModIDThe module ID of an input. | Integer32 Constraints: range: 1-7 | .1.3.6.1.4.1.248.14.1.13.2.1.1.1 | ||||||
| hmIOModValueDigInputIDThe ID of an input. | Integer32 Constraints: range: 1-4 | .1.3.6.1.4.1.248.14.1.13.2.1.1.2 | ||||||
| hmIOModValueDigInputValueStatus of the input. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the input has high (+24V) value, if the value is low(2), the input has low (0V) value. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.248.14.1.13.2.1.1.3 |
.1.3.6.1.4.1.248.14.1.13.2.2
·
1 row entry
·
3 columns
Uses the hirschmann variant from
Command help
/opt/observium/mibs/hirschmann.
Walk hmIOModValueDigOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HMIOMODULE-SNMP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HMIOMODULE-SNMP-MIB::hmIOModValueDigOutputTable'
IO module value table for outputs
IO module value entry for outputs
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hmIOModValueDigOutputModIDThe module ID of an Output. | Integer32 Constraints: range: 1-7 | .1.3.6.1.4.1.248.14.1.13.2.2.1.1 | ||||||||||
| hmIOModValueDigOutputIDThe ID of an Output. | Integer32 Constraints: range: 1-4 | .1.3.6.1.4.1.248.14.1.13.2.2.1.2 | ||||||||||
| hmIOModValueDigOutputValueStatus of the output. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the output has high (+24V) value, if the value is low(2), the output has low (0V) value. If the valu… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.248.14.1.13.2.2.1.3 |