HM2-PWRMGMT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
21

hm2PSTable

table
.1.3.6.1.4.1.248.11.11.1.1.1 · 1 row entry · 2 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PSTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-PWRMGMT-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-PWRMGMT-MIB::hm2PSTable'
This table contains all variables related to the power supply
units of the chassis/switch. For each power supply slot exists
one instance.
hm2PSEntry row .1.3.6.1.4.1.248.11.11.1.1.1.1
The entry of the hm2PSTable.
Indexes
Column Syntax OID
This index is used to identify the associated power supply
unit.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.248.11.11.1.1.1.1.1
Indicates the operational state of the associated power
supply. If the value of this variable changes, a hm2PowerSupply
trap is sent.
Enumeration
Enumerated Values:
1present
2defective
3notInstalled
4unknown
.1.3.6.1.4.1.248.11.11.1.1.1.1.2
.1.3.6.1.4.1.248.11.11.1.1.10 · 1 row entry · 10 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PSUSlotInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-PWRMGMT-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-PWRMGMT-MIB::hm2PSUSlotInfoTable'
This table contains all EEPROM variables related to the power supply
slot modules of the chassis/switch. For each power supply slot module exists
one instance.
hm2PSUSlotInfoEntry row .1.3.6.1.4.1.248.11.11.1.1.10.1
The entry of the hm2PSUSlotInfoTable.
Indexes
Column Syntax OID
This index is used to identify the associated power supply
slot module.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.248.11.11.1.1.10.1.1
The chassis type id of the associated power supply
slot module.
Enumeration
Enumerated Values:
0other
1mach1020
2mach4000
3railswitch
4grs
.1.3.6.1.4.1.248.11.11.1.1.10.1.2
The manufacturer id of the associated power supply
slot module.
Enumeration
Enumerated Values:
0other
1hirschmann
.1.3.6.1.4.1.248.11.11.1.1.10.1.3
The manufacturer date of the associated power supply
slot module.
*** NOTE this is set to OBSOLETE ***
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.4
The serial number of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.5
The product code of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.6
The description of the associated power supply
slot module.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.248.11.11.1.1.10.1.7
The combination type of the associated power supply
slot module.
Enumeration
Enumerated Values:
0only-on-psu1
1psu1-sys-psu2-poe
2psu1-poe-psu2-sys
3two-separate-psus
.1.3.6.1.4.1.248.11.11.1.1.10.1.8
The temperature range of the associated power supply
slot module.
Enumeration
Enumerated Values:
0tr-0-60
1tr-minus40-60
2tr-minus40-70
3tr-minus40-70cc
4tr-minus40-85
5tr-minus40-85cc
.1.3.6.1.4.1.248.11.11.1.1.10.1.9
Hardware revision of the PSU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.248.11.11.1.1.10.1.10
.1.3.6.1.4.1.248.11.11.1.1.20 · 1 row entry · 9 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PSUUnitInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-PWRMGMT-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-PWRMGMT-MIB::hm2PSUUnitInfoTable'
This table contains all EEPROM variables related to the power supply
slot module units. For each power supply slot module exists
up to two instances.
hm2PSUUnitInfoEntry row .1.3.6.1.4.1.248.11.11.1.1.20.1
The entry of the hm2PSUUnitInfoTable.
Column Syntax OID
The number of PSU units on the associated power supply
slot module.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.1
The converter type of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1ac
2dc
.1.3.6.1.4.1.248.11.11.1.1.20.1.2
The number of inputs of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.3
The output type of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1system
2both
3poe
.1.3.6.1.4.1.248.11.11.1.1.20.1.4
The system budget of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.11.1.1.20.1.5
The PoE budget of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.11.1.1.20.1.6
The fan count of the associated power supply
slot module unit.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.248.11.11.1.1.20.1.7
The voltage range of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
0vr-18-60vdc
1vr-24-60vdc
2vr-24-48vdc
3vr-60-250vdc-110-240vac
4vr-48-54vdc-poe
.1.3.6.1.4.1.248.11.11.1.1.20.1.8
The power interruption value of the associated power supply
slot module unit.
Enumeration
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.248.11.11.1.1.20.1.9