HH3C-NPV-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
6
.1.3.6.1.4.1.25506.2.127.6.1.1.2 · 1 row entry · 3 columns
Uses the hh3c variant from /opt/observium/mibs/hh3c.
Command help
Walk hh3cNpvTrafficMapConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HH3C-NPV-MIB' -M '/opt/observium/mibs/hh3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HH3C-NPV-MIB::hh3cNpvTrafficMapConfigTable'
A table containing information on the assignment of
traffic map interfaces to an interface.
hh3cNpvTrafficMapConfigEntry row .1.3.6.1.4.1.25506.2.127.6.1.1.2.1
An entry in the hh3cNpvTrafficMapConfigTable.

This table contains entries for each of the interfaces
which has been assigned a set of interfaces for traffic
mapping in the VSAN.

Traffic mapping…
Column Syntax OID
The list of external interfaces which the traffic needs
to be mapped to.

This object is a list of interfaces presented as
an octet string of interface indices or ifindex-es.

The list should…
Hh3cNpvIfIndexListr/w
Type Constraints:
range: 4..65535
.1.3.6.1.4.1.25506.2.127.6.1.1.2.1.1
The value of sysUpTime at the time of the latest
change to this traffic map entry.

When there has not been any change to the traffic
map entry, the value of this field will be that
of the entry creation t…
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.25506.2.127.6.1.1.2.1.2
The status of this conceptual row.

The row can be made 'active' only if value of corresponding
instance of hh3cNpvTrafficMapExternalIfIndexList is provided.
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.25506.2.127.6.1.1.2.1.3
.1.3.6.1.4.1.25506.2.127.6.1.1.3 · 1 row entry · 1 columns
Uses the hh3c variant from /opt/observium/mibs/hh3c.
Command help
Walk hh3cNpvServerIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HH3C-NPV-MIB' -M '/opt/observium/mibs/hh3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HH3C-NPV-MIB::hh3cNpvServerIfTable'
This table contains, one entry for each server
interface(FC-port configured in F-port mode) in
this VSAN in the Fabric element.
          
Each entry contains NPV related information like
external interface assigned for the server interface
in the VSAN.
hh3cNpvServerIfEntry row .1.3.6.1.4.1.25506.2.127.6.1.1.3.1
An entry in the hh3cNpvServerIfTable, containing NPV
related parameters established by a server interface
indicated by ifIndex.
Column Syntax OID
This value of this object is the external interface assigned
for the server interface associated with the server interface.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.25506.2.127.6.1.1.3.1.1
.1.3.6.1.4.1.25506.2.127.6.1.1.4 · 1 row entry · 2 columns
Uses the hh3c variant from /opt/observium/mibs/hh3c.
Command help
Walk hh3cNpvLoadBalanceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HH3C-NPV-MIB' -M '/opt/observium/mibs/hh3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HH3C-NPV-MIB::hh3cNpvLoadBalanceTable'
This table contains NPV load balancing parameters of each VSAN.
hh3cNpvLoadBalanceEntry row .1.3.6.1.4.1.25506.2.127.6.1.1.4.1
An entry provides NPV load balancing parameters for a VSAN.
Column Syntax OID
This object is used to enable or disable NPV auto load balance
on this VSAN to equalize server login distribution when server
logins are not evenly distributed across uplinks.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.25506.2.127.6.1.1.4.1.1
This object is used to start an auto load balance timer
on this VSAN when the failed uplink is up. A NPV auto
load balance will be triggered when the timer expires.

If this object is not configured, the …
secondsUnsigned32r/w
Constraints:
range: 1-300
.1.3.6.1.4.1.25506.2.127.6.1.1.4.1.2