GUDEADS-ETS8801-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
43
ets8801TrapIPTable
table.1.3.6.1.4.1.28507.41.1.1.1.2
·
1 row entry
·
2 columns
Uses the gude variant from
Command help
/opt/observium/mibs/gude.
Walk ets8801TrapIPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-ETS8801-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-ETS8801-MIB::ets8801TrapIPTable'
list of all Trap receiver
an entry containing management
informations regarding the list of trap
receivers
informations regarding the list of trap
receivers
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value, greater than zero, for each receiver slot.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.28507.41.1.1.1.2.1.1 |
|
DNS name or IP address specifying one Trap receiver slot.
A port can optionally be specified: 'name:port' An empty string disables this slot. |
OctetStringr/w Constraints: range: 0-99 |
.1.3.6.1.4.1.28507.41.1.1.1.2.1.2 |
ets8801PowerTable
table.1.3.6.1.4.1.28507.41.1.5.1.2
·
1 row entry
·
25 columns
Uses the gude variant from
Command help
/opt/observium/mibs/gude.
Walk ets8801PowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-ETS8801-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-ETS8801-MIB::ets8801PowerTable'
All available Channel Interfaces.
An entry containing management information
applicable to a particular Power Channel.
applicable to a particular Power Channel.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index of Power Channel entries
|
Integer32 Constraints: range: 1-1 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.1 |
|
0 = data not active, 1 = data valid
|
Integer32 Constraints: range: 0-1 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.2 |
|
Absolute Active Energy counter.
|
WhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.3 |
|
Active Power
|
WSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.4 |
|
Actual Curent on Power Channel.
|
mASNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.5 |
|
Actual Voltage on Power Channel
|
VSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.6 |
|
Frequency of Power Channel
|
0.01 hzSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.7 |
|
Power Factor of Channel between
-1.0 and 1.00 |
0.001SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.8 |
|
Phase Angle between Voltage
and L Line Current between -180.0 and 180.0 |
0.1 degreeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.9 |
|
L Line Mean Apparent Power
|
VASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.10 |
|
L Line Mean Reactive Power
|
VARSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.11 |
|
Absolute Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.12 |
|
Resettable Absolute Active Energy counter.
Writing '0' resets all resettable counter. |
WhSNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.13 |
|
Resettable Absolute Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.14 |
|
Time in seconds since last Energy
Counter reset. |
sSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.15 |
|
Forward Active Energy counter.
|
WhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.16 |
|
Forward Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.17 |
|
Resettable Forward Active Energy counter.
|
WhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.18 |
|
Resettable Forward Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.19 |
|
Reverse Active Energy counter.
|
WhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.20 |
|
Reverse Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.21 |
|
Resettable Reverse Active Energy counter.
|
WhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.22 |
|
Resettable Reverse Reactive Energy counter.
|
VARhSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.23 |
|
Actual Residual Current on Power Channel.
According Typ A IEC 60755. Only visible on models that support this feature. |
0.1 mASNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.24 |
|
A textual string containing name of a
Line Sensor |
OctetStringr/w Constraints: range: 0-32 |
.1.3.6.1.4.1.28507.41.1.5.1.2.1.100 |
ets8801FuseTable
table.1.3.6.1.4.1.28507.41.1.5.2
·
1 row entry
·
2 columns
Uses the gude variant from
Command help
/opt/observium/mibs/gude.
Walk ets8801FuseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-ETS8801-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-ETS8801-MIB::ets8801FuseTable'
C13 Output Block Fuse Table
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.28507.41.1.5.2.1.1 |
|||||||
|
shows the status of the
C13 Output Block Fuse |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.28507.41.1.5.2.1.2 |
ets8801SensorTable
table.1.3.6.1.4.1.28507.41.1.6.1
·
1 row entry
·
8 columns
Uses the gude variant from
Command help
/opt/observium/mibs/gude.
Walk ets8801SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-ETS8801-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-ETS8801-MIB::ets8801SensorTable'
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.28507.41.1.6.1.1.1 |
|||||
|
actual temperature
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.1.1.2 |
||||
|
actual humidity
|
0.1 percent humiditySNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.1.1.3 |
||||
|
logical state of input sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.28507.41.1.6.1.1.4 |
||||
|
actual air pressure
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.1.1.5 |
||||
|
dew point for actual temperature and humidity
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.1.1.6 |
||||
|
difference between dew point and actual
temperature (Temp - DewPoint) |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.1.1.7 |
||||
|
A textual string containing name of a
external Sensor |
OctetStringr/w Constraints: range: 0-32 |
.1.3.6.1.4.1.28507.41.1.6.1.1.32 |
ets8801ExtInputTable
table.1.3.6.1.4.1.28507.41.1.6.2.2
·
1 row entry
·
6 columns
Uses the gude variant from
Command help
/opt/observium/mibs/gude.
Walk ets8801ExtInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-ETS8801-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-ETS8801-MIB::ets8801ExtInputTable'
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.6.2.2.1.1 |
|||||
|
Input state of device
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.28507.41.1.6.2.2.1.2 |
||||
|
Number of times the Input has changed its state.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.28507.41.1.6.2.2.1.3 |
||||
|
A textual string containing name of
the Input |
OctetStringr/w Constraints: range: 0-32 |
.1.3.6.1.4.1.28507.41.1.6.2.2.1.32 |
||||
|
Number of external Sensor Port when value greater zero, else device built-in Input.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.2.2.1.33 |
||||
|
Either index of device built-in Input, or index of Input in external sensor.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.28507.41.1.6.2.2.1.34 |