FORTINET-CORE-MIB
MIB module for Fortinet network devices.
fortinet
1.3.6.1.4.1.12356
Imported Objects
| IF-MIB | ifIndex |
| INET-ADDRESS-MIB | InetAddress InetAddressPrefixLength InetAddressType |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-MIB | sysName |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION |
Type Definitions (4)
| FnBoolState | Enumeration |
disabled(1)enabled(2) |
| FnIndex | Integer32 |
range: 0..2147483647 |
| FnLanguage | Enumeration |
english(1)simplifiedChinese(2)japanese(3)korean(4)spanish(5)traditionalChinese(6)french(7)portuguese(8)undefined(255) |
| FnSessionProto | Enumeration |
ip(0)icmp(1)igmp(2)ipip(4)tcp(6)egp(8)pup(12)udp(17)idp(22)ipv6(41)rsvp(46)gre(47)esp(50)ah(51)ospf(89)pim(103)comp(108)raw(255) |
Objects (21)
|
|
.1.3.6.1.4.1.12356 |
|
|
|
.1.3.6.1.4.1.12356.100 |
|
|
|
.1.3.6.1.4.1.12356.100.1 |
|
|
|
.1.3.6.1.4.1.12356.100.1.1 |
|
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.100.1.1.1 |
|
|
.1.3.6.1.4.1.12356.100.1.2 |
|
|
|
FnLanguage | .1.3.6.1.4.1.12356.100.1.2.1 |
|
|
.1.3.6.1.4.1.12356.100.1.2.100 |
|
|
|
Integer32 | .1.3.6.1.4.1.12356.100.1.2.100.1 |
|
|
.1.3.6.1.4.1.12356.100.1.2.100.2 |
|
|
|
fnAdminIndex | .1.3.6.1.4.1.12356.100.1.2.100.2.1 |
|
|
Integer32 | .1.3.6.1.4.1.12356.100.1.2.100.2.1.1 |
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.100.1.2.100.2.1.2 |
|
|
INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.12356.100.1.2.100.2.1.3 |
|
|
INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.12356.100.1.2.100.2.1.4 |
|
|
INET-ADDRESS-MIBInetAddressPrefixLength | .1.3.6.1.4.1.12356.100.1.2.100.2.1.5 |
|
|
.1.3.6.1.4.1.12356.100.1.3 |
|
|
|
.1.3.6.1.4.1.12356.100.1.3.0 |
|
|
|
.1.3.6.1.4.1.12356.100.1.3.1 |
|
|
|
SNMPv2-TCDisplayString | .1.3.6.1.4.1.12356.100.1.3.1.1 |
|
|
.1.3.6.1.4.1.12356.100.10 |
Notifications / Traps (13)
| Name | OID | Description |
|---|---|---|
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.101 |
Indicates that the CPU usage has exceeded the configured threshold. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.102 |
Indicates memory usage has exceeded the configured threshold. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.103 |
Log disk usage has exceeded the configured threshold. Only available on devices with log disks. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.104 |
A temperature sensor on the device has exceeded its threshold. Not all devices have thermal sensors. See manual for specifications. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.105 |
Power levels have fluctuated outside of normal levels. Not all devices have voltage monitoring instrumentation. See manual for specifications. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.106 |
Power supply failure detected. Not available on all models. Available on some devices which support redundant power supplies. See manual for specifications. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.107 |
An AMC interface entered bypass mode. Available on models with an AMC expansion slot. Used with the ASM-CX4 and ASM-FX2 cards. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.108 |
A fan failure has been detected. Not all devices have fan sensors. See manual for specifications. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.109 |
Interface entered bypass mode. Available on models with bypass ports. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.110 |
Interface exited bypass mode. Available on models with bypass ports. |
|
|
.1.3.6.1.4.1.12356.100.1.3.0.111 |
BIOS security level has been change. |
|
|
.1.3.6.1.4.1.12356.100.1.3.0.201 |
Indicates that the IP address of the specified interface has been changed. |
|
fnSysSerial SNMPv2-MIBsysName
|
.1.3.6.1.4.1.12356.100.1.3.0.999 |
Trap sent for diagnostic purposes by an administrator. |