FE-FIREEYE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
6
Rows
6
Columns
76
eventTable
table.1.3.6.1.4.1.25597.1.1.2
·
1 row entry
·
50 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk eventTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::eventTable'
List of events
Entry for one event
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Synthetic numeric unique ID of event
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.1 |
||||||||||||||
|
Id of event
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.2 |
||||||||||||||
|
Type of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.3 |
||||||||||||||
|
Date of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.4 |
||||||||||||||
|
Time of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.5 |
||||||||||||||
|
Trace ID of event
|
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.25597.1.1.2.1.6 |
||||||||||||||
|
Source IP address of event
|
SNMPv2-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.25597.1.1.2.1.7 |
||||||||||||||
|
Destination IP address of event
|
SNMPv2-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.25597.1.1.2.1.8 |
||||||||||||||
|
Source MAC address of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.9 |
||||||||||||||
|
Destination MAC address of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.10 |
||||||||||||||
|
Attacked port of event
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.25597.1.1.2.1.11 |
||||||||||||||
|
VLAN of event
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.25597.1.1.2.1.12 |
||||||||||||||
|
IP protocol of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.13 |
||||||||||||||
|
Profile ID of event
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.14 |
||||||||||||||
|
OS info of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.15 |
||||||||||||||
|
Attacked service of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.16 |
||||||||||||||
|
Attack type of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.17 |
||||||||||||||
|
Signature name of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.18 |
||||||||||||||
|
Signature type of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.19 |
||||||||||||||
|
Host name of event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.20 |
||||||||||||||
|
Cncno of event
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.21 |
||||||||||||||
|
Malware Identification
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.22 |
||||||||||||||
|
Alert CNC host name
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.23 |
||||||||||||||
|
Alert CNC Port
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.25597.1.1.2.1.24 |
||||||||||||||
|
Alert Malware Checksum
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.25 |
||||||||||||||
|
Alert analysis type
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.26 |
||||||||||||||
|
Alert analysis profile
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.27 |
||||||||||||||
|
Alert action taken
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.28 |
||||||||||||||
|
Appliance interface
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.29 |
||||||||||||||
|
Appliance IP address
|
SNMPv2-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.25597.1.1.2.1.30 |
||||||||||||||
|
Appliance host name
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.31 |
||||||||||||||
|
Product Name
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.32 |
||||||||||||||
|
Alert URL
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.33 |
||||||||||||||
|
Alert URL
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.34 |
||||||||||||||
|
Source IP address type
|
INET-ADDRESS-MIBInetAddressType Type Values:
|
.1.3.6.1.4.1.25597.1.1.2.1.35 |
||||||||||||||
|
Source IP address
|
INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 |
.1.3.6.1.4.1.25597.1.1.2.1.36 |
||||||||||||||
|
Destination IP address type
|
INET-ADDRESS-MIBInetAddressType Type Values:
|
.1.3.6.1.4.1.25597.1.1.2.1.37 |
||||||||||||||
|
Destination IP address
|
INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 |
.1.3.6.1.4.1.25597.1.1.2.1.38 |
||||||||||||||
|
Sensor IP address type
|
INET-ADDRESS-MIBInetAddressType Type Values:
|
.1.3.6.1.4.1.25597.1.1.2.1.39 |
||||||||||||||
|
Sensor IP address
|
INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 |
.1.3.6.1.4.1.25597.1.1.2.1.40 |
||||||||||||||
|
Source port
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.25597.1.1.2.1.41 |
||||||||||||||
|
Date and time of the event
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.42 |
||||||||||||||
|
IPS signature id
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.43 |
||||||||||||||
|
IPS signature revision
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.44 |
||||||||||||||
|
Attack count
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.1.1.2.1.45 |
||||||||||||||
|
Severity
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.46 |
||||||||||||||
|
Name of the signature
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.47 |
||||||||||||||
|
Reference ID
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.48 |
||||||||||||||
|
isBlocked
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.49 |
||||||||||||||
|
Attack target
|
OctetString | .1.3.6.1.4.1.25597.1.1.2.1.50 |
fePhysicalDiskTable
table.1.3.6.1.4.1.25597.11.2.1.3
·
1 row entry
·
7 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk fePhysicalDiskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::fePhysicalDiskTable'
The physical disk table
An entry for one physical disk
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each disk
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.11.2.1.3.1.1 |
||||
|
Physical disk name
|
OctetString | .1.3.6.1.4.1.25597.11.2.1.3.1.2 |
||||
|
Physical disk status
|
OctetString | .1.3.6.1.4.1.25597.11.2.1.3.1.3 |
||||
|
Whether a physical disk is healthy.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.11.2.1.3.1.4 |
||||
|
Physical disk configuration, e.g. RAID
|
OctetString | .1.3.6.1.4.1.25597.11.2.1.3.1.5 |
||||
|
Self assess of a physical disk
|
OctetString | .1.3.6.1.4.1.25597.11.2.1.3.1.6 |
||||
|
The capacity of a physical disk.
|
OctetString | .1.3.6.1.4.1.25597.11.2.1.3.1.7 |
fePowerSupplyTable
table.1.3.6.1.4.1.25597.11.3.1.3
·
1 row entry
·
3 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk fePowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::fePowerSupplyTable'
The power supply table
An entry for one physical disk
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each power supply
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.11.3.1.3.1.1 |
||||
|
Power supply status
|
OctetString | .1.3.6.1.4.1.25597.11.3.1.3.1.2 |
||||
|
Whether a power supply is healthy.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.11.3.1.3.1.3 |
feFanStatusTable
table.1.3.6.1.4.1.25597.11.4.1.3
·
1 row entry
·
4 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk feFanStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::feFanStatusTable'
The Fan Status table
An entry for one fan
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each fan status table entry
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.11.4.1.3.1.1 |
||||
|
Fan status
|
OctetString | .1.3.6.1.4.1.25597.11.4.1.3.1.2 |
||||
|
Whether a fan is healthy.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.11.4.1.3.1.3 |
||||
|
Fan speed in rpm
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.11.4.1.3.1.4 |
feGIVersionTable
table.1.3.6.1.4.1.25597.11.5.1.8
·
1 row entry
·
5 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk feGIVersionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::feGIVersionTable'
The guest image version table
An entry for one guest image
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each guest image
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.11.5.1.8.1.1 |
||||
|
Guest image name
|
OctetString | .1.3.6.1.4.1.25597.11.5.1.8.1.2 |
||||
|
Guest image version
|
OctetString | .1.3.6.1.4.1.25597.11.5.1.8.1.3 |
||||
|
Whether guest image is enabled.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.11.5.1.8.1.4 |
||||
|
Guest image install date and time
|
OctetString | .1.3.6.1.4.1.25597.11.5.1.8.1.5 |
feCMSApplianceTable
table.1.3.6.1.4.1.25597.12.1.6
·
1 row entry
·
7 columns
Uses the fireeye variant from
Command help
/opt/observium/mibs/fireeye.
Walk feCMSApplianceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FE-FIREEYE-MIB' -M '/opt/observium/mibs/fireeye:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FE-FIREEYE-MIB::feCMSApplianceTable'
The CMS managed appliance table
An entry for one CMS managed appliance
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each CMS managed appliance
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.25597.12.1.6.1.1 |
||||
|
The name of the CMS managed appliance
|
OctetString | .1.3.6.1.4.1.25597.12.1.6.1.2 |
||||
|
Whether a CMS managed appliance passed disk space check.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.12.1.6.1.3 |
||||
|
Whether a CMS managed appliance passed fan check.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.12.1.6.1.4 |
||||
|
Whether a CMS managed appliance passed power supply check.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.12.1.6.1.5 |
||||
|
Whether a CMS managed appliance passed RAID check.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.25597.12.1.6.1.6 |
||||
|
Whether a CMS managed appliance passed temperature check.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |