FE-FIREEYE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
76
.1.3.6.1.4.1.25597.1.1.2 · 1 row entry · 50 columns
List of events
eventEntry entry .1.3.6.1.4.1.25597.1.1.2.1
Entry for one event
Indexes
eventIndex
Column Syntax OID
eventIndex
Synthetic numeric unique ID of event
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.1
eventId
Id of event
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.2
eventType
Type of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.3
eventDate
Date of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.4
eventTime
Time of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.5
eventTraceId
Trace ID of event
SNMPv2-SMICounter64
Textual Convention: SNMPv2-SMICounter64 Unsigned64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.25597.1.1.2.1.6
eventSrcIp
Source IP address of event
SNMPv2-SMIIpAddress
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.25597.1.1.2.1.7
eventDstIp
Destination IP address of event
SNMPv2-SMIIpAddress
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.25597.1.1.2.1.8
eventSrcMac
Source MAC address of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.9
eventDstMac
Destination MAC address of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.10
eventDstPort
Attacked port of event
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.25597.1.1.2.1.11
eventVlan
VLAN of event
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.25597.1.1.2.1.12
eventProtocol
IP protocol of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.13
eventProfileId
Profile ID of event
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.14
eventOsInfo
OS info of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.15
eventService
Attacked service of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.16
eventAttackType
Attack type of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.17
eventSignatureName
Signature name of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.18
eventSignatureType
Signature type of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.19
eventSrcHost
Host name of event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.20
eventCncNo
Cncno of event
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.21
alertSignatureId
Malware Identification
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.22
alertCncHost
Alert CNC host name
OctetString .1.3.6.1.4.1.25597.1.1.2.1.23
alertCncPort
Alert CNC Port
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.25597.1.1.2.1.24
alertChecksum
Alert Malware Checksum
OctetString .1.3.6.1.4.1.25597.1.1.2.1.25
alertAnalysisType
Alert analysis type
OctetString .1.3.6.1.4.1.25597.1.1.2.1.26
alertProfile
Alert analysis profile
OctetString .1.3.6.1.4.1.25597.1.1.2.1.27
alertAction
Alert action taken
OctetString .1.3.6.1.4.1.25597.1.1.2.1.28
alertInterface
Appliance interface
OctetString .1.3.6.1.4.1.25597.1.1.2.1.29
alertSensorIp
Appliance IP address
SNMPv2-SMIIpAddress
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.25597.1.1.2.1.30
alertSensorHost
Appliance host name
OctetString .1.3.6.1.4.1.25597.1.1.2.1.31
alertSensorProduct
Product Name
OctetString .1.3.6.1.4.1.25597.1.1.2.1.32
alertSensorRelease
Alert URL
OctetString .1.3.6.1.4.1.25597.1.1.2.1.33
alertUrl
Alert URL
OctetString .1.3.6.1.4.1.25597.1.1.2.1.34
eventSrcAddrType
Source IP address type
INET-ADDRESS-MIBInetAddressType
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.25597.1.1.2.1.35
eventSrcAddr
Source IP address
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.25597.1.1.2.1.36
eventDstAddrType
Destination IP address type
INET-ADDRESS-MIBInetAddressType
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.25597.1.1.2.1.37
eventDstAddr
Destination IP address
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.25597.1.1.2.1.38
eventSensorAddrType
Sensor IP address type
INET-ADDRESS-MIBInetAddressType
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.25597.1.1.2.1.39
eventSensorAddr
Sensor IP address
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.25597.1.1.2.1.40
eventSrcPort
Source port
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.25597.1.1.2.1.41
eventDateTime
Date and time of the event
OctetString .1.3.6.1.4.1.25597.1.1.2.1.42
ipsSignatureId
IPS signature id
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.43
ipsSignatureRevision
IPS signature revision
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.44
ipsMatchCount
Attack count
SNMPv2-SMIGauge32
Textual Convention: SNMPv2-SMIGauge32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.1.1.2.1.45
ipsSeverity
Severity
OctetString .1.3.6.1.4.1.25597.1.1.2.1.46
ipsSignatureName
Name of the signature
OctetString .1.3.6.1.4.1.25597.1.1.2.1.47
ipsReferenceId
Reference ID
OctetString .1.3.6.1.4.1.25597.1.1.2.1.48
ipsBlockMode
isBlocked
OctetString .1.3.6.1.4.1.25597.1.1.2.1.49
ipsAttackTarget
Attack target
OctetString .1.3.6.1.4.1.25597.1.1.2.1.50
.1.3.6.1.4.1.25597.11.2.1.3 · 1 row entry · 7 columns
The physical disk table
fePhysicalDiskEntry entry .1.3.6.1.4.1.25597.11.2.1.3.1
An entry for one physical disk
Indexes
fePhysicalDiskIndex
Column Syntax OID
fePhysicalDiskIndex
A unique value for each disk
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.11.2.1.3.1.1
fePhysicalDiskName
Physical disk name
OctetString .1.3.6.1.4.1.25597.11.2.1.3.1.2
fePhysicalDiskStatus
Physical disk status
OctetString .1.3.6.1.4.1.25597.11.2.1.3.1.3
fePhysicalDiskIsHealthy
Whether a physical disk is healthy.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.11.2.1.3.1.4
fePhysicalDiskDeviceSupport
Physical disk configuration, e.g. RAID
OctetString .1.3.6.1.4.1.25597.11.2.1.3.1.5
fePhysicalDiskSelfAssess
Self assess of a physical disk
OctetString .1.3.6.1.4.1.25597.11.2.1.3.1.6
fePhysicalDiskTotalBytes
The capacity of a physical disk.
OctetString .1.3.6.1.4.1.25597.11.2.1.3.1.7
.1.3.6.1.4.1.25597.11.3.1.3 · 1 row entry · 3 columns
The power supply table
fePowerSupplyEntry entry .1.3.6.1.4.1.25597.11.3.1.3.1
An entry for one physical disk
Indexes
fePowerSupplyIndex
Column Syntax OID
fePowerSupplyIndex
A unique value for each power supply
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.11.3.1.3.1.1
fePowerSupplyStatus
Power supply status
OctetString .1.3.6.1.4.1.25597.11.3.1.3.1.2
fePowerSupplyIsHealthy
Whether a power supply is healthy.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.11.3.1.3.1.3
.1.3.6.1.4.1.25597.11.4.1.3 · 1 row entry · 4 columns
The Fan Status table
feFanStatusEntry entry .1.3.6.1.4.1.25597.11.4.1.3.1
An entry for one fan
Indexes
feFanIndex
Column Syntax OID
feFanIndex
A unique value for each fan status table entry
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.11.4.1.3.1.1
feFanStatus
Fan status
OctetString .1.3.6.1.4.1.25597.11.4.1.3.1.2
feFanIsHealthy
Whether a fan is healthy.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.11.4.1.3.1.3
feFanSpeed
Fan speed in rpm
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.11.4.1.3.1.4
.1.3.6.1.4.1.25597.11.5.1.8 · 1 row entry · 5 columns
The guest image version table
feGIVersionEntry entry .1.3.6.1.4.1.25597.11.5.1.8.1
An entry for one guest image
Indexes
feGIIndex
Column Syntax OID
feGIIndex
A unique value for each guest image
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.11.5.1.8.1.1
feGIName
Guest image name
OctetString .1.3.6.1.4.1.25597.11.5.1.8.1.2
feGIVersion
Guest image version
OctetString .1.3.6.1.4.1.25597.11.5.1.8.1.3
feGIEnabled
Whether guest image is enabled.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.11.5.1.8.1.4
feGIInstallDateTime
Guest image install date and time
OctetString .1.3.6.1.4.1.25597.11.5.1.8.1.5
.1.3.6.1.4.1.25597.12.1.6 · 1 row entry · 7 columns
The CMS managed appliance table
feCMSApplianceEntry entry .1.3.6.1.4.1.25597.12.1.6.1
An entry for one CMS managed appliance
Indexes
feCMSApplianceIndex
Column Syntax OID
feCMSApplianceIndex
A unique value for each CMS managed appliance
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.25597.12.1.6.1.1
feCMSApplianceName
The name of the CMS managed appliance
OctetString .1.3.6.1.4.1.25597.12.1.6.1.2
feCMSApplianceDiskSpacePassed
Whether a CMS managed appliance passed disk space check.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.12.1.6.1.3
feCMSApplianceFanPassed
Whether a CMS managed appliance passed fan check.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.12.1.6.1.4
feCMSAppliancePowerSupplyPassed
Whether a CMS managed appliance passed power supply check.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.12.1.6.1.5
feCMSApplianceRaidPassed
Whether a CMS managed appliance passed RAID check.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.12.1.6.1.6
feCMSApplianceTemperaturePassed
Whether a CMS managed appliance passed temperature check.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.25597.12.1.6.1.7