FAN-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
7
hpicfFanTable
table.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1
·
1 row entry
·
7 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk hpicfFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FAN-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FAN-MIB::hpicfFanTable'
This table contains one row for every fan in the switch entity.
Information about fan entity table.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The index that is used to access the switch fan entry table.
|
HpicfDcFanIndex | .1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.1 |
||||||||||||||
|
The tray number in which the fan is docked.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.2 |
||||||||||||||
|
An indication of the vendor-specific fan.
|
HpicfDcFanType Type Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.3 |
||||||||||||||
|
The current state of the fan.
|
HpicfDcFanState Type Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.4 |
||||||||||||||
|
An indication that the switch fan entity is faulty.
Before declaring a fan to be good after a failure is detected, the same good indication must happen five (5) times in a row. A failure indication is always TRUE, whil… |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.5 |
||||||||||||||
|
The number of times the fan has failed.
|
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.6 |
||||||||||||||
|
Indication of the fan air flow direction, either
from Power supply towards the port or from the port towards the power supply. |
HpicfDcFanAirflowDirection Type Values:
|
.1.3.6.1.4.1.11.2.14.11.5.1.54.2.1.1.7 |