ES-RACKTIVITY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
9
Rows
9
Columns
411

eESNTable

table
.1.3.6.1.4.1.34097.9.65.1 · 1 row entry · 65 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eESNTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eESNTable'
Temperature Humidity Presure Airflow Waterleak
eESNEntry row .1.3.6.1.4.1.34097.9.65.1.1
Temperature Humidity Presure Airflow Waterleak
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUhundredth .1.3.6.1.4.1.34097.9.65.1.1.4
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
CURPORTSTATE
Type Values:
0portOff
1portOnNoWarning
2portOff1
3portOnWithWarningCurrent
4portOff2
5portOnWithWarningPower
6portOff3
7portOnWithWarningCurrentAndPower
8portOffWithError
9portOnNoWarning1
10portOffWithError1
11portOnWithWarningCurrent1
12portOffWithError2
13portOnWithWarningPower1
14portOffWithError3
15portOnWithWarnCurrentAndPower1
16portOffWithDelayOn
17portOnNoWarning2
18portOffWithDelayOn1
19portOnWithWarningCurrent2
20portOffWithDelayOn2
21portOnWithWarningPower2
22portOffWithDelayOn3
23portOnWithWarnCurrentAndPower2
.1.3.6.1.4.1.34097.9.65.1.1.8
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.65.1.1.11
Gets the relative humidity. (unit: 0.1RH)
RHUtenth .1.3.6.1.4.1.34097.9.65.1.1.12
Gets the current airflow level. (unit: 0.1m/s)
m/sUtenth .1.3.6.1.4.1.34097.9.65.1.1.23
Gets the current dewpoint. Taking the current humidity into consideration, condensation will occur if the temperature drops below this level. (unit: 0.1K)
KUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.25
Gets the atmospheric pressure. (unit: 0.1hPa)
hPaUtenth .1.3.6.1.4.1.34097.9.65.1.1.26
Gets the value of an analog input (voltage). (unit: mV)
mVSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.27
Gets the current state of the water leak sensor.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.28
Gets or resets whether motion has been detected.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.65.1.1.29
Gets the state of a digital input.
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.65.1.1.30
The current for high values (unit: 0.1A)
AInteger32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.41
The power for high values (unit: 0.01kW)
kWInteger32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.43
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.65.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.65.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10005
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
minUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.65.1.1.10032
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10047
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10049
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.65.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.65.1.1.10053
Gets, sets or defaults the minimum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
RHUnsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.65.1.1.10054
Gets, sets or defaults the maximum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
RHUnsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.65.1.1.10055
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10078
Enables or disables the SNMP trap if the power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10080
Enables or disables the SNMP trap if the voltage warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10086
Enables or disables the SNMP trap if the temperature warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10087
Enables or disables the SNMP trap if the humidity warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10088
Gets, sets or defaults the dewpoint warning level. If the temperature difference between the current temperature and the dewpoint temperature drops below this value, an event is generated. (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10092
Enables or disables the SNMP trap if the dewpoint warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10093
Enables or disables the SNMP trap if the dewpoint temperature is reached.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10094
Enables or disables the SNMP trap if the atmospheric pressure warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10095
Gets, sets or defaults the minimum atmospheric pressure warning level. (unit: 0.1hPa)
hPaUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10096
Gets, sets or defaults the maximum atmospheric pressure warning level. (unit: 0.1hPa)
hPaUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10097
Gets, sets or defaults the display brightness (if supported).
Unsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.65.1.1.10098
Gets, sets or defaults the sensitivity of a motion sensor.
Unsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.4.1.34097.9.65.1.1.10107
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10109
Gets, sets or defaults an Energy Sensor relay label.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10110
Gets, sets or defaults the lower warning level for an analog input. A warning is generated if this level is exceeded. (unit: mV)
mVUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10111
Gets, sets or defaults the upper warning level for an analog input. A warning is generated if this level is exceeded.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10112
Gets, sets or defaults the water leak detection state (0 = disabled, other values = enabled).
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10113
Gets, sets or defaults the minimum warning level for an airflow sensor. A warning is generated if this level is exceeded.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10114
Gets, sets or defaults the maximum warning level for an airflow sensor. A warning is generated if this level is exceeded.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.65.1.1.10115
Enables or disables the SNMP trap if the analog input warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10116
Enables or disables the SNMP trap if a water leak is detected.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10117
Enables or disables the SNMP trap if the airflow warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10118
Enables or disables the SNMP trap if an Energy Sensor relay is asserted.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10119
Enables or disables the SNMP trap if an Energy Sensor relay is deasserted.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10120
Gets, sets or defaults the motion warning threshold.
Unsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.4.1.34097.9.65.1.1.10141
Enables or disables the SNMP trap if the motion warning threshold is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10149
The ID of the device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10150
The version of the device.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.65.1.1.10151
The full name of the device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.65.1.1.10152
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.10165
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.10176
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.10177
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.65.1.1.10178
Enables or disables the SNMP trap if the IO Port change state.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.65.1.1.10192
Index for the selected ESN Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.65.1.1.65537
Selected ESN Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.65.1.1.65538
.1.3.6.1.4.1.34097.9.66.1 · 1 row entry · 2 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eThreePhasePowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eThreePhasePowerTable'
NO_INFO
eThreePhasePowerEntry row .1.3.6.1.4.1.34097.9.66.1.1
NO_INFO
Column Syntax OID
Index for the selected ThreePhasePower Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.66.1.1.65537
Selected ThreePhasePower Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.66.1.1.65538
.1.3.6.1.4.1.34097.9.68.1 · 1 row entry · 15 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eDisplayModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eDisplayModuleTable'
NO_INFO
eDisplayModuleEntry row .1.3.6.1.4.1.34097.9.68.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.68.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.68.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.68.1.1.3
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.68.1.1.11
Gets the amount of seconds since the last reset. (unit: s)
sSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.68.1.1.24
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.68.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.68.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.68.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.68.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.68.1.1.10005
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.68.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.68.1.1.10053
If a display need to show all devices or just a small list
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.68.1.1.10237
Index for the selected DisplayModule Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.68.1.1.65537
Selected DisplayModule Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.68.1.1.65538
.1.3.6.1.4.1.34097.9.69.1 · 1 row entry · 43 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eEnergyMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eEnergyMonitorTable'
NO_INFO
eEnergyMonitorEntry row .1.3.6.1.4.1.34097.9.69.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUhundredth .1.3.6.1.4.1.34097.9.69.1.1.4
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
HzUthousandth .1.3.6.1.4.1.34097.9.69.1.1.5
Gets the current of an outlet. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.69.1.1.6
Gets the power of an outlet. (unit: W)
WSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.7
Gets the energy used by an outlet. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.69.1.1.9
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
kVAhUthousandth .1.3.6.1.4.1.34097.9.69.1.1.10
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.69.1.1.11
Gets the apparent power of an outlet. (unit: VA)
VASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.15
Gets the power factor of an outlet. (unit: %)
%SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.16
Gets the total current of a power module. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.69.1.1.17
Gets the total power level of a power module. (unit: W)
WSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.18
Gets the total apparent power of a power module. (unit: VA)
VASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.19
Gets the total energy of a power module. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.69.1.1.20
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
kVAhUthousandth .1.3.6.1.4.1.34097.9.69.1.1.21
Gets the total power factor of a power module. (unit: %)
%SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.22
Gets the amount of seconds since the last reset. (unit: s)
sSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.69.1.1.24
total harmonic distortion - outlet (unit: 0.1%)
%Unsigned32
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.69.1.1.50
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.69.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.69.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.69.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.69.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.69.1.1.10005
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-8000
.1.3.6.1.4.1.34097.9.69.1.1.10039
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-2000
.1.3.6.1.4.1.34097.9.69.1.1.10041
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-16000
.1.3.6.1.4.1.34097.9.69.1.1.10043
Gets, sets or defaults the maximum total power warning level. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-4000
.1.3.6.1.4.1.34097.9.69.1.1.10045
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.69.1.1.10047
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.69.1.1.10049
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.69.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.69.1.1.10053
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10078
Enables or disables the SNMP trap if the power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10080
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10082
Enables or disables the SNMP trap if the total power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10084
Enables or disables the SNMP trap if the voltage warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10086
Enables or disables the SNMP trap if the temperature warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10087
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
msUnsigned32r/w
Constraints:
range: 10-65535
.1.3.6.1.4.1.34097.9.69.1.1.10135
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.69.1.1.10136
Index for the selected EnergyMonitor Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.69.1.1.65537
Selected EnergyMonitor Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.69.1.1.65538

eMasterTable

table
.1.3.6.1.4.1.34097.9.77.1 · 1 row entry · 126 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eMasterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eMasterTable'
NO_INFO
eMasterEntry row .1.3.6.1.4.1.34097.9.77.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.77.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.77.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.77.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUhundredth .1.3.6.1.4.1.34097.9.77.1.1.4
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.77.1.1.11
Gets the current IP address. To set the IP address, use IPADDR instead.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.14
Gets the total current of a power module. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.77.1.1.17
Gets the total power level of a power module. (unit: W)
WSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.77.1.1.18
Gets the total energy of a power module. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.77.1.1.20
Gets the current line current. (unit: 0.001A)
AUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.32
Gets the current through a fuse. (unit: 0.001A)
AUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.33
Gets the current subnet mask. To set the subnet mask use SNMSK instead.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.34
Gets the current DNS server. To set the DNS server use DNSSRV instead.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.35
Gets the current standard gateway. To set the standard gateway use STDGW instead.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.36
Checks if a UPS is present.
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.37
Gets the working status of a UPS (if its working on its batteries or not).
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.77.1.1.38
Gets the estimated run time of a UPS. (unit: min)
minUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.39
The current UPS battery level. (unit: 0.1%)
%Unsigned32
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.77.1.1.40
The current for high values (unit: 0.1A)
AStenth .1.3.6.1.4.1.34097.9.77.1.1.41
Status information of communication with the UPS
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.42
The power for high values (unit: 0.01kW)
kWInteger32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.43
The current for high values (unit: 0.1A)
AInteger32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.44
The power for high values (unit: 0.01kW)
kWInteger32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.45
Gets the positive energy used by an outlet. (unit: 0.001kWh)
kWhUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.34097.9.77.1.1.46
Gets the negative energy used by an outlet. (unit: 0.001kWh)
kWhUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.34097.9.77.1.1.47
Gets the positive energy of the module. (unit: 0.001kWh)
kWhUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.34097.9.77.1.1.48
Gets the negative energy of the module. (unit: 0.001kWh)
kWhUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.34097.9.77.1.1.49
Gets the status of the connection with the cloud. 0 = Idle state; 1 = Disabled; 2 = Initialising; 3 = Initialising - No connection; 4 = Initialising - No key; 5 = Connection Ok; 6 = Connection Failed; 7 = Connection Fai…
Unsigned32
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.77.1.1.56
status of a module
Unsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.1000
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10005
Gets, sets or defaults the name of the rack.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10006
Gets, sets or defaults the position in the rack.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10007
Gets, sets or defaults the IP address (when DHCP is disabled).
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10011
Gets, sets or defaults the subnet mask (when DHCP is disabled).
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10012
Gets, sets or defaults the standard gateway (when DHCP is disabled).
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10013
Gets, sets or defaults the IP address of the used DNS server (when DHCP is disabled).
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10014
Gets the MAC address of a master module.
SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.34097.9.77.1.1.10015
Enables, disables or defaults DHCP. Set to 1 to enable DHCP, or 0 to disable DHCP.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10016
Gets, sets or defaults the NTP (Network Time Protocol) server IP address.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10017
Enables, disables or defaults the usage of the default NTP (Network Time Protocol) server (pool.ntp.org).
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10018
Enables, disables or defaults NTP (Network Time Protocol). Set to 1 to enable NTP, or 0 to disable NTP.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10019
Gets, sets or defaults the SNMP trap receiver IP address.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10020
Gets, sets or defaults the SNMP tap receiver port.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10021
Enables, disables or defaults write access over SNMP. Set to 1 to disable write access, or 0 to enable write access.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10024
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server IP address.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10028
Enables, disables or defaults the use of an ECS (Energy Cloud Sentinel) server. Set to 1 to enable or 0 to disable.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10029
Gets, sets or defaults the display lock. If the display is locked, you can still view information on the display, but you are not allowed to change settings through the menu system.
Unsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.77.1.1.10031
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
minUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.77.1.1.10032
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10047
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10049
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.77.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.77.1.1.10053
Gets, sets or defaults general events. If set to 0, no events will be generated. Set to 1 to generate events on media indicated by the event bitfields.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10074
Gets, sets or defaults the SNMP contact information.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10075
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10078
Enables or disables the SNMP trap if the power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10080
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10082
Enables or disables the SNMP trap if the total power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10084
Enables or disables the SNMP trap if the voltage warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10086
Enables or disables the SNMP trap if the temperature warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10087
Gets, sets or defaults the display brightness (if supported).
Unsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.77.1.1.10098
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server port.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10106
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10109
Enables or disables the use of HTTPS (secure HTTP). Set to 1 to enable HTTPS only, or 0 to also enable HTTP.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10127
Enables or disables the use of Telnet SSL (secure Telnet). Set to 1 to enable Telnet SSL, or 0 to disable Telnet SSL).
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10128
The TTL (Time To Live) of the website cookie. (unit: min)
minUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10130
Gets, sets the warning threshold of the linecurrent. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10131
Gets, sets the off threshold of the linecurrent. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.77.1.1.10132
Enables or disables the SNMP trap if the linecurrent warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10133
Enables or disables the SNMP trap if the linecurrent off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10134
Gets, sets or defaults the maximum current warning threshold per fuse. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 0-32000
.1.3.6.1.4.1.34097.9.77.1.1.10142
Gets, sets or defaults the maximum current off threshold per fuse. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 0-32000
.1.3.6.1.4.1.34097.9.77.1.1.10143
Enables or disables the SNMP trap if the fusecurrent warning threshold is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10144
Enables or disables the SNMP trap if the fusecurrent off threshold is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10145
The ID of the device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10150
The version of the device.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10151
The full name of the device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10152
Gets the electrical topology of the unit.
Unsigned32
Constraints:
range: 0-2
.1.3.6.1.4.1.34097.9.77.1.1.10153
Gets the topology between the outlets and fuses.
Unsigned32
Constraints:
range: 0-6
.1.3.6.1.4.1.34097.9.77.1.1.10154
Gets the topology between the inlet (cable or connection) and the fuses.
Unsigned32
Constraints:
range: 0-3
.1.3.6.1.4.1.34097.9.77.1.1.10155
Gets, sets the IP address of an SSO (Smart Style Office).
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.77.1.1.10156
Gets, sets the login credentials of an SSO (Smart Style Office).
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10157
Gets, sets the string to send if the UPS' battery level is below the set threshold.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10158
Gets, sets or defaults the graceful shutdown threshold of a UPS.
Unsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.77.1.1.10159
Gets, sets or defaults the threshold of a UPS to set outlets off.
Unsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.77.1.1.10160
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10165
Disables/Enables UPS monitoring and selects the protocol used for UPS monitoring. 0 = Disabled; 1 = Use old APC protocol
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10167
When the UPS battery level goes below this threshold a shutdown request will be sent to all agents (unit: 0.1%)
%Unsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.77.1.1.10168
When the UPS battery level goes above this threshold a outlets will be powered on as configured by the user (unit: 0.1%)
%Unsigned32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.77.1.1.10169
Event flags for events related to the UPS monitoring
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.77.1.1.10170
When the UPS was on battery and it went below UPSEMERGTHRES, the outlets that have a load below the RECOVPOWERTHRES will be power cycled once the UPS is back on mains power and exceeds UPSRECOVTHRES (unit: W)
WUnsigned32r/w
Constraints:
range: 20-4000
.1.3.6.1.4.1.34097.9.77.1.1.10171
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10176
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10177
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10178
Interval (in seconds) between 2 heartbeat SNMP traps, Set to 0 to disable (unit: s)
sUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.77.1.1.10179
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10180
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
AInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10181
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10182
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
kWInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10183
Set if the device needs to push info to the init cloud (val=0) or to the normal cloud (val=1)
Unsigned32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.34097.9.77.1.1.10208
get or set the DC sensor bias (unit: mV)
mVInteger32r/w
Constraints:
range: -32768-32767
.1.3.6.1.4.1.34097.9.77.1.1.10210
allowed modes: 0: standalone (master without daisy chain slaves) 1: daisy chain master 2: daisy chain slave 1 3: daisy chain slave 2 4: daisy chain slave 3
Unsigned32r/w
Constraints:
range: 0-4
.1.3.6.1.4.1.34097.9.77.1.1.10211
Gets, sets or defaults the SNMP tap user out of the user list.
Unsigned32r/w
Constraints:
range: 0-4
.1.3.6.1.4.1.34097.9.77.1.1.10212
Gets, sets or defaults the SNMP USM security user
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10213
Gets, sets or defaults the SNMP USM authentication passphrase (Always MD5)
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10214
Gets, sets or defaults the SNMP USM private passphrase (Always AES)
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10215
Gets, sets or defaults the SNMP V2 Enable for get ,set or walk but not for traps.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10216
Gets, sets or defaults the SNMP V3 Enable for get ,set or walk but not for traps.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10217
Gets, sets or defaults the SNMP USM authentication passphrase length
Unsigned32r/w
Constraints:
range: 0-16
.1.3.6.1.4.1.34097.9.77.1.1.10218
Gets, sets or defaults the SNMP USM private passphrase length
Unsigned32r/w
Constraints:
range: 0-16
.1.3.6.1.4.1.34097.9.77.1.1.10219
Gets, sets or defaults the SNMP Trap Enable per trap account
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10222
Attribute linked to the LDAPFilter
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10227
Relative Path to be used for the LDAPFilter
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10228
GroupName for Admin Credentials in LDAP
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10229
GroupName for Restricted Credentials in LDAP
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10230
GroupName for Guest Credentials in LDAP
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10231
Enable or disable login via LDAP credentials
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10232
Wrapper for login in with LDAP
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10233
NO_INFO
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.77.1.1.10235
Set if local authentication is still possible if LDAP is enabled
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.77.1.1.10236
Index for the selected Master Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.77.1.1.65537
Selected Master Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.77.1.1.65538

ePowerTable

table
.1.3.6.1.4.1.34097.9.80.1 · 1 row entry · 88 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk ePowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::ePowerTable'
NO_INFO
ePowerEntry row .1.3.6.1.4.1.34097.9.80.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUhundredth .1.3.6.1.4.1.34097.9.80.1.1.4
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
HzUthousandth .1.3.6.1.4.1.34097.9.80.1.1.5
Gets the current of an outlet. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.80.1.1.6
Gets the power of an outlet. (unit: W)
WSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.7
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
CURPORTSTATE
Type Values:
0portOff
1portOnNoWarning
2portOff1
3portOnWithWarningCurrent
4portOff2
5portOnWithWarningPower
6portOff3
7portOnWithWarningCurrentAndPower
8portOffWithError
9portOnNoWarning1
10portOffWithError1
11portOnWithWarningCurrent1
12portOffWithError2
13portOnWithWarningPower1
14portOffWithError3
15portOnWithWarnCurrentAndPower1
16portOffWithDelayOn
17portOnNoWarning2
18portOffWithDelayOn1
19portOnWithWarningCurrent2
20portOffWithDelayOn2
21portOnWithWarningPower2
22portOffWithDelayOn3
23portOnWithWarnCurrentAndPower2
.1.3.6.1.4.1.34097.9.80.1.1.8
Gets the energy used by an outlet. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.80.1.1.9
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
kVAhUthousandth .1.3.6.1.4.1.34097.9.80.1.1.10
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.80.1.1.11
Gets the apparent power of an outlet. (unit: VA)
VASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.15
Gets the power factor of an outlet. (unit: %)
%SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.16
Gets the total current of a power module. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.80.1.1.17
Gets the total power level of a power module. (unit: W)
WSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.18
Gets the total apparent power of a power module. (unit: VA)
VASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.19
Gets the total energy of a power module. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.80.1.1.20
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
kVAhUthousandth .1.3.6.1.4.1.34097.9.80.1.1.21
Gets the total power factor of a power module. (unit: %)
%SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.22
Gets the amount of seconds since the last reset. (unit: s)
sSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.24
total harmonic distortion - outlet (unit: 0.1%)
%Unsigned32
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.80.1.1.50
the phase between 2 waves (unit: degr)
degrUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.80.1.1.51
Gets the current of an outlet. (unit: 0.0001A)
ASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.80.1.1.52
Gets the power of an outlet. (unit: 0.001W)
WUthousandth .1.3.6.1.4.1.34097.9.80.1.1.53
Gets the apparent power of an outlet. (unit: 0.001VA)
VAUthousandth .1.3.6.1.4.1.34097.9.80.1.1.54
Gives the best matching Phase per currentsensor. Updated every 8s. returnes 255 if no good phaselink is found
Unsigned32
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.80.1.1.55
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.80.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.80.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.80.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.80.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.80.1.1.10005
Gets, sets or defaults the name of an outlet.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.80.1.1.10034
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Unsigned32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.34097.9.80.1.1.10035
Gets, sets or defaults the priority of an outlet. Priority settings are used when 1 or more outlets must be turned off because the total current of a power module was exceeded.
Unsigned32r/w
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.80.1.1.10036
Gets, sets or defaults the outlet turn-on delay. Use this to reduce inrush current when the Energy Switch boots. (unit: s)
sUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.80.1.1.10037
Gets, sets or defaults the maximum current off level of an outlet. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-8000
.1.3.6.1.4.1.34097.9.80.1.1.10038
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-8000
.1.3.6.1.4.1.34097.9.80.1.1.10039
Gets, sets or defaults the maximum power off level of an outlet. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-2000
.1.3.6.1.4.1.34097.9.80.1.1.10040
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-2000
.1.3.6.1.4.1.34097.9.80.1.1.10041
Gets, sets or defaults the total maximum current off level of a power module. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-16000
.1.3.6.1.4.1.34097.9.80.1.1.10042
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
AUnsigned32r/w
Constraints:
range: 100-16000
.1.3.6.1.4.1.34097.9.80.1.1.10043
Gets, sets or defaults the maximum total power off level. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-4000
.1.3.6.1.4.1.34097.9.80.1.1.10044
Gets, sets or defaults the maximum total power warning level. (unit: W)
WUnsigned32r/w
Constraints:
range: 20-4000
.1.3.6.1.4.1.34097.9.80.1.1.10045
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.80.1.1.10047
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.80.1.1.10049
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.80.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.80.1.1.10053
Enables or disables the SNMP trap if the state of an outlet is changed.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10076
Enables or disables the SNMP trap if the outlet current off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10077
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10078
Enables or disables the SNMP trap if the power off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10079
Enables or disables the SNMP trap if the power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10080
Enables or disables the SNMP trap if the total outlet current off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10081
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10082
Enables or disables the SNMP trap if the total power off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10083
Enables or disables the SNMP trap if the total power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10084
Enables or disables the SNMP trap if the voltage warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10086
Enables or disables the SNMP trap if the temperature warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10087
Gets, sets or defaults the maximum overheat temperature off level. (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.80.1.1.10090
Enables or disables the SNMP trap if the overtemperature off level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10091
Gets, sets or defaults the time interval that is used to do a power cycle of an outlet. (unit: s)
sUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.80.1.1.10099
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.80.1.1.10109
Gets, sets or defaults the overheating temperature warning level. (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.80.1.1.10121
Enables or disables the SNMP trap if the overheat warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10122
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
msUnsigned32r/w
Constraints:
range: 10-65535
.1.3.6.1.4.1.34097.9.80.1.1.10135
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10136
The threshold of the soft fuse is a factor of the maximum nominal current off (unit: A)
AUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.80.1.1.10137
The minimum time the current of an outlet must be above the soft fuse current threshold to switch it off. (unit: ms)
msUnsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.80.1.1.10138
Enables or disables the SNMP trap if a soft fuse is triggered.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10139
Enables or disables the SNMP trap if a phase shift on the voltage is detected.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10140
Gets, sets or defaults the time for the scheduler to turn on an outlet. (unit: min)
minUnsigned32r/w
Constraints:
range: 0-1439
.1.3.6.1.4.1.34097.9.80.1.1.10146
Gets, sets or defaults the time for the scheduler to turn off an outlet. (unit: min)
minUnsigned32r/w
Constraints:
range: 0-1439
.1.3.6.1.4.1.34097.9.80.1.1.10147
Enables or disables the scheduler on an outlet. When enabled the scheduling is repeated daily.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.80.1.1.10148
Prevent outlets to be set off (only delay on and powercycle are still possible).
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.80.1.1.10161
event if a port has changed state because of the scheduler
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10166
IP address of the agent associated to this outlet
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.80.1.1.10172
Network port on which the associated agent will listen
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.80.1.1.10173
Event flags for events related to agent communication
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.80.1.1.10174
Outlets marked as Always On can only be power cycled by the user
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.80.1.1.10175
sets the slope of the transducer transfer function when the generic transducer type is selected (unit: mA/V)
mA/VInteger32r/w
Constraints:
range: 2000-2000000000
.1.3.6.1.4.1.34097.9.80.1.1.10190
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
AUnsigned32r/w
Constraints:
range: 100-400000000
.1.3.6.1.4.1.34097.9.80.1.1.10193
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
WUnsigned32r/w
Constraints:
range: 2000-2000000000
.1.3.6.1.4.1.34097.9.80.1.1.10194
Group number per port to group ports
Unsigned32r/w
Constraints:
range: 0-5
.1.3.6.1.4.1.34097.9.80.1.1.10195
Link the current port with a voltage phase
Unsigned32r/w
Constraints:
range: 0-8
.1.3.6.1.4.1.34097.9.80.1.1.10196
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
Unsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.80.1.1.10197
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
AUnsigned32r/w
Constraints:
range: 0-400000000
.1.3.6.1.4.1.34097.9.80.1.1.10209
Index for the selected Power Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.80.1.1.65537
Selected Power Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.80.1.1.65538
.1.3.6.1.4.1.34097.9.81.1 · 1 row entry · 43 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eMeasuring3PhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eMeasuring3PhaseTable'
NO_INFO
eMeasuring3PhaseEntry row .1.3.6.1.4.1.34097.9.81.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUhundredth .1.3.6.1.4.1.34097.9.81.1.1.4
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
HzUthousandth .1.3.6.1.4.1.34097.9.81.1.1.5
Gets the energy used by an outlet. (unit: 0.001kWh)
kWhUthousandth .1.3.6.1.4.1.34097.9.81.1.1.9
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
kVAhUthousandth .1.3.6.1.4.1.34097.9.81.1.1.10
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUtenth .1.3.6.1.4.1.34097.9.81.1.1.11
Gets the power factor of an outlet. (unit: %)
%SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.16
Gets the amount of seconds since the last reset. (unit: s)
sSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.24
Gets the state of a digital input.
Unsigned32
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.81.1.1.30
total harmonic distortion - outlet (unit: 0.1%)
%Unsigned32
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.81.1.1.50
the phase between 2 waves (unit: degr)
degrUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.81.1.1.51
Gets the current of an outlet. (unit: 0.0001A)
ASNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.81.1.1.52
Gets the power of an outlet. (unit: 0.001W)
WUthousandth .1.3.6.1.4.1.34097.9.81.1.1.53
Gets the apparent power of an outlet. (unit: 0.001VA)
VAUthousandth .1.3.6.1.4.1.34097.9.81.1.1.54
status of a module
Unsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.81.1.1.1000
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.81.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.81.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.81.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.81.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.81.1.1.10005
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.81.1.1.10035
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.81.1.1.10047
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
VUnsigned32r/w
Constraints:
range: 5000-30000
.1.3.6.1.4.1.34097.9.81.1.1.10049
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.81.1.1.10052
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
KUnsigned32r/w
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.81.1.1.10053
Enables or disables the SNMP trap if the state of an outlet is changed.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10076
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10078
Enables or disables the SNMP trap if the power warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10080
Enables or disables the SNMP trap if the voltage warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10086
Enables or disables the SNMP trap if the temperature warning level is exceeded.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10087
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
msUnsigned32r/w
Constraints:
range: 10-65535
.1.3.6.1.4.1.34097.9.81.1.1.10135
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
EVENTFLAGSr/w
Type Values:
0sNMPTrapOff
1sNMPTrapOn
.1.3.6.1.4.1.34097.9.81.1.1.10136
The ID of the device.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.81.1.1.10150
The version of the device.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.81.1.1.10151
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
AUnsigned32r/w
Constraints:
range: 100-400000000
.1.3.6.1.4.1.34097.9.81.1.1.10193
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
WUnsigned32r/w
Constraints:
range: 2000-2000000000
.1.3.6.1.4.1.34097.9.81.1.1.10194
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
Unsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.34097.9.81.1.1.10197
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
AUnsigned32r/w
Constraints:
range: 0-400000000
.1.3.6.1.4.1.34097.9.81.1.1.10209
Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative
Unsigned32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.34097.9.81.1.1.10234
Index for the selected Measuring3Phase Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.81.1.1.65537
Selected Measuring3Phase Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.81.1.1.65538

ePCTable

table
.1.3.6.1.4.1.34097.9.85.1 · 1 row entry · 16 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk ePCTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::ePCTable'
NO_INFO
ePCEntry row .1.3.6.1.4.1.34097.9.85.1.1
NO_INFO
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.85.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.85.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.85.1.1.3
Gets the voltage of a power module. (unit: 0.01V)
VUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.85.1.1.4
Gets the current of an outlet. (unit: 0.001A)
AUnsigned32
Constraints:
range: 0-65535
.1.3.6.1.4.1.34097.9.85.1.1.6
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
CURPORTSTATE
Type Values:
0portOff
1portOnNoWarning
2portOff1
3portOnWithWarningCurrent
4portOff2
5portOnWithWarningPower
6portOff3
7portOnWithWarningCurrentAndPower
8portOffWithError
9portOnNoWarning1
10portOffWithError1
11portOnWithWarningCurrent1
12portOffWithError2
13portOnWithWarningPower1
14portOffWithError3
15portOnWithWarnCurrentAndPower1
16portOffWithDelayOn
17portOnNoWarning2
18portOffWithDelayOn1
19portOnWithWarningCurrent2
20portOffWithDelayOn2
21portOnWithWarningPower2
22portOffWithDelayOn3
23portOnWithWarnCurrentAndPower2
.1.3.6.1.4.1.34097.9.85.1.1.8
Gets the current temperature of a temperature sensor. (unit: 0.1K)
KUnsigned32
Constraints:
range: 2232-4732
.1.3.6.1.4.1.34097.9.85.1.1.11
Gets the relative humidity. (unit: 0.1RH)
RHUnsigned32
Constraints:
range: 0-1000
.1.3.6.1.4.1.34097.9.85.1.1.12
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.85.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.85.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.85.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.85.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.85.1.1.10005
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.34097.9.85.1.1.10035
Index for the selected PC Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.85.1.1.65537
Selected PC Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.85.1.1.65538
.1.3.6.1.4.1.34097.9.89.1 · 1 row entry · 13 columns
Uses the racktivity variant from /opt/observium/mibs/racktivity.
Command help
Walk eTestModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ES-RACKTIVITY-MIB' -M '/opt/observium/mibs/racktivity:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ES-RACKTIVITY-MIB::eTestModuleTable'
Module to test the R-bus
eTestModuleEntry row .1.3.6.1.4.1.34097.9.89.1.1
Module to test the R-bus
Column Syntax OID
General status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.89.1.1.1
Specific status of a module.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.89.1.1.2
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
UNIXSNMPv2-SMITimeTicksr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.89.1.1.3
Gets the current of an outlet. (unit: 0.001A)
AUthousandth .1.3.6.1.4.1.34097.9.89.1.1.6
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
CURPORTSTATE
Type Values:
0portOff
1portOnNoWarning
2portOff1
3portOnWithWarningCurrent
4portOff2
5portOnWithWarningPower
6portOff3
7portOnWithWarningCurrentAndPower
8portOffWithError
9portOnNoWarning1
10portOffWithError1
11portOnWithWarningCurrent1
12portOffWithError2
13portOnWithWarningPower1
14portOffWithError3
15portOnWithWarnCurrentAndPower1
16portOffWithDelayOn
17portOnNoWarning2
18portOffWithDelayOn1
19portOnWithWarningCurrent2
20portOffWithDelayOn2
21portOnWithWarningPower2
22portOffWithDelayOn3
23portOnWithWarnCurrentAndPower2
.1.3.6.1.4.1.34097.9.89.1.1.8
Gets the value of an analog input (voltage). (unit: mV)
mVSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.34097.9.89.1.1.27
Gets, sets or defaults the module name.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.89.1.1.10001
Gets the version of the module's firmware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.89.1.1.10002
Gets the version of a module's hardware.
Version
Type Constraints:
range: 4
.1.3.6.1.4.1.34097.9.89.1.1.10003
Gets the ID of the module's firmware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.89.1.1.10004
Gets the ID of a module's hardware.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.34097.9.89.1.1.10005
Index for the selected TestModule Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.89.1.1.65537
Selected TestModule Module
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.34097.9.89.1.1.65538