ELTEX-MES-HARDWARE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
19
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1 · 1 row entry · 7 columns
Uses the eltex variant from /opt/observium/mibs/eltex.
Command help
Walk eltHardwareSerdesRxConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-HARDWARE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-HARDWARE-MIB::eltHardwareSerdesRxConfigTable'
Serdes Rx parameters configuration.
eltHardwareSerdesRxConfigEntry row .1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1
Defines the contents of each line in the eltHardwareSerdesRxConfigTable table.
Column Syntax OID
Interface Index.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.1
Lane number.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.2
Enable user configured parameters to port serdes
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.3
Threshold that trips the squelch detector peak-to-peak differential amplitude.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.4
Feed Forward Equalization (FFE) resistor select.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.5
Feed Forward Equalization (FFE) capacitor select.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.6
Align 90 calibration phase offset.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.1.1.7
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2 · 1 row entry · 8 columns
Uses the eltex variant from /opt/observium/mibs/eltex.
Command help
Walk eltHardwareSerdesTxConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-HARDWARE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-HARDWARE-MIB::eltHardwareSerdesTxConfigTable'
Serdes Tx parameters configuration.
eltHardwareSerdesTxConfigEntry row .1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1
Defines the contents of each line in the eltHardwareSerdesTxConfigTable table.
Column Syntax OID
Interface Index.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.1
Lane number.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.2
Enable user configured parameters to port serdes
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.3
Tx Driver output amplitude.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.4
Enable transmitter amplitude adjust.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.5
Controls the emphasis amplitude for Gen0 bit rates.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.6
Controls the emphasis amplitude for Gen1 bit rates.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.7
Enable transmitter amplitude shift.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.35265.1.23.14.1.1.1.2.1.8
.1.3.6.1.4.1.35265.1.23.14.1.1.1.3 · 1 row entry · 4 columns
Uses the eltex variant from /opt/observium/mibs/eltex.
Command help
Walk eltHardwareInterfaceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-HARDWARE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-HARDWARE-MIB::eltHardwareInterfaceTable'
Hardware profile mode configuration.
eltHardwareInterfaceEntry row .1.3.6.1.4.1.35265.1.23.14.1.1.1.3.1
Defines the contents of each port in the eltHardwareInterfaceTable table.
Column Syntax OID
Interface Index.
IF-MIBInterfaceIndexr/w
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.35265.1.23.14.1.1.1.3.1.1
Breakout mode after reset.
EltBreakoutModer/w
Type Values:
1default
2mode-4x10
.1.3.6.1.4.1.35265.1.23.14.1.1.1.3.1.2
Breakout mode.
EltBreakoutMode
Type Values:
1default
2mode-4x10
.1.3.6.1.4.1.35265.1.23.14.1.1.1.3.1.3
Expanded interfaces.
Q-BRIDGE-MIBPortList .1.3.6.1.4.1.35265.1.23.14.1.1.1.3.1.4