EKINOPS-Pmlma10-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
46
Rows
46
Columns
189
.1.3.6.1.4.1.20044.68.2.2.1.232
·
1 row entry
·
11 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmclientSfpWarnDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmclientSfpWarnDdmTable'
List of pmlma10AlmclientSfpWarnDdm Article
Row definition for the pmlma10AlmclientSfpWarnDdm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmclientSfpWarnDdm
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.2.1.232.1.1 |
||||
|
Client Trscv Tx Power Low Warning
:This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv output power is lower than t… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.2 |
||||
|
Client Trscv Tx Power High Warning
:This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv output power is higher tha… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.3 |
||||
|
Client Trscv Bias Low Warning
:This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv laser bias current is lowe… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.4 |
||||
|
Client Trscv Bias High Warning
:This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv laser bias current is hi… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.5 |
||||
|
Client Trscv Power Supply Low
Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv power supply is lower th… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.6 |
||||
|
Client Trscv Power Supply High
Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv power supply is higher… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.7 |
||||
|
Client Trscv Temp Low Warning
:This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv temperature is lower than the thr… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.8 |
||||
|
Client Trscv Temp High Warning
:This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv temperature is higher than the … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.9 |
||||
|
Client Trscv Rx Power Low Warning
:This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv input power is lower than the… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.16 |
||||
|
Client Trscv Rx Power High Warning
:This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv input power is higher than … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.1.232.1.17 |
.1.3.6.1.4.1.20044.68.2.2.2.88
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmclientHostLaneFaultTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmclientHostLaneFaultTable'
List of pmlma10AlmclientHostLaneFault Article
Row definition for the pmlma10AlmclientHostLaneFault
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmclientHostLaneFault
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.2.2.88.1.1 |
||||
|
Client Frame Alignment Loss :This
OID indicates the module is not aligned with the incoming Client signal <Help> Alarm indicating the module is not aligned with the incoming client signal <Condtype> CLIENT_LOSS_OF… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.88.1.2 |
||||
|
Client Input Loss Of Signal :This
OID indicates a Loss of Signal is detected on the Client Trscv <Help> Alarm indicating a Loss of Signal is detected on the Client Trscv <Condtype> CLIENT_INPUT_LOSS_OF_SIG <Probca… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.88.1.3 |
||||
|
Client Signal Fail Detected :This
OID indicates that a CSF has been detected on client port in the downstream direction <Help> This alarm indicates if a Client Signal Fail has been detected in the incoming line… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.88.1.7 |
||||
|
Client Tx FIFO Error :This OID
indicates a Tx FIFO Error on the Client Trscv <Help> Alarm indicating a Tx FIFO Error on the Client Trscv <Condtype> CLIENT_LANE_TX_FIFO_ERROR <Probcause> receiverFailure (42) <Alarm… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.88.1.11 |
.1.3.6.1.4.1.20044.68.2.2.2.216
·
1 row entry
·
11 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmclientSfpAlmDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmclientSfpAlmDdmTable'
List of pmlma10AlmclientSfpAlmDdm Article
Row definition for the pmlma10AlmclientSfpAlmDdm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmclientSfpAlmDdm
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.2.2.216.1.1 |
||||
|
Client Trscv Tx Power Low :This
OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv output power of port is lower … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.2 |
||||
|
Client Trscv Tx Power High :This
OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv output power of port is high… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.3 |
||||
|
Client Trscv Bias Low :This OID
indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv laser bias current of port i… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.4 |
||||
|
Client Trscv Bias High :This OID
indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv laser bias current of port… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.5 |
||||
|
Client Trscv Power Supply Low
:This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv power supply of port is lo… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.6 |
||||
|
Client Trscv Power Supply High
:This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv power supply of port is … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.7 |
||||
|
Client Trscv Temp Low :This OID
indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv temperature of port is lower than t… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.8 |
||||
|
Client Trscv Temp High :This OID
indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv temperature of port is higher tha… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.9 |
||||
|
Client Trscv Rx Power Low :This
OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv input power of port is lower th… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.16 |
||||
|
Client Trscv Rx Power High :This
OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv input power of port is higher… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.2.216.1.17 |
.1.3.6.1.4.1.20044.68.2.2.3.8
·
1 row entry
·
12 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmsynthAlmPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmsynthAlmPortTable'
List of pmlma10AlmsynthAlmPort Article
Row definition for the pmlma10AlmsynthAlmPort
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmsynthAlmPort
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.2.3.8.1.1 |
||||
|
Client Optical Module Absent :This
OID indicates that the Transceiver is not present in the client port. <Help> This alarm indicates if the client transceiver is not plugged <Condtype> SFP_ABSENT_1 <Probcause> inp… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.2 |
||||
|
DDM Supported On Client Trscv
:This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function <Help> This status indicates if the client transceiver includes the DDM feature <Co… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.3 |
||||
|
Client HW Fail :This OID indicates
a failure on client port, most probably caused by a HW issue. <Help> This alarm indicates a failure on client port, most probably caused by a HW issue. <Condtype> HW_FAIL_ACC_1 <… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.5 |
||||
|
Client Trscv Laser Shutdown :This
OID indicates the Client transceiver laser is shutdown <Help> This status indicates if the client transceiver laser is shutdown <Condtype> DW_LSD_1 <Probcause> other (1) <Alarmtype… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.6 |
||||
|
Local Client Port In Service :This
OID indicates that the local Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the local client port is in service <Condtype> CLIENT_LOCAL_OOS <… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.7 |
||||
|
Remote Client Port In Service
:This OID indicates that the remote Client port is In Service (1) or Out of Service (2) <Help> This status indicates if the remote client port is in service <Condtype> CLIENT_REMOTE_O… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.8 |
||||
|
Client AIS Inserted :This OID
indicates a CAIS has been inserted on the output client port. <Help> This status indicates if a Client Alarm Indication Signal is currently inserted on the client interface <Condtype>… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.9 |
||||
|
Warning On Client Trscv DDM :This
OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has been detected on the client transceiver <Condtype> SFP_D… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.10 |
||||
|
Alarm On Client Trscv DDM :This
OID indicates an alarm is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Alarm has been detected on the client transceiver <Condtype> SFP_DDM_AL… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.11 |
||||
|
Client Access Fail :This OID indicates
a failure on the Client port <Help> This alarm indicates a failure on the Client port <Condtype> FAIL_ACC_1 <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.13 |
||||
|
Client Signal Fail Inserted :This
OID indicates a CSF has been inserted in the upstream client port. <Help> This status indicates if a Client Signal Fail is currently inserted on the line signal for this client po… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.2.3.8.1.17 |
.1.3.6.1.4.1.20044.68.2.3.2.104
·
1 row entry
·
11 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmlineNetworkLaneAlarmWarning1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmlineNetworkLaneAlarmWarning1Table'
List of pmlma10AlmlineNetworkLaneAlarmWarning1 Article
Row definition for the pmlma10AlmlineNetworkLaneAlarmWarning1
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmlineNetworkLaneAlarmWarning1
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.3.2.104.1.1 |
||||
|
Line Trscv Tx Power Low :This
OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv output power of port is lower th… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.2 |
||||
|
Line Trscv Tx Power High :This
OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv output power of port is higher… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.3 |
||||
|
Line Trscv Bias Low :This OID
indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv laser bias current of port is … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.4 |
||||
|
Line Trscv Bias High :This OID
indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv laser bias current of port i… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.5 |
||||
|
Line Trscv Power Supply Low :This
OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv power supply of port is lowe… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.6 |
||||
|
Line Trscv Power Supply High :This
OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv power supply of port is hi… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.7 |
||||
|
Line Trscv Temp Low :This OID
indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv temperature of port is lower than the… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.8 |
||||
|
Line Trscv Temp High :This OID
indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv temperature of port is higher than … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.9 |
||||
|
Line Trscv Rx Power Low :This
OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv input power of port is lower than… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.16 |
||||
|
Line Trscv Rx Power High :This
OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv input power of port is higher t… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.104.1.17 |
.1.3.6.1.4.1.20044.68.2.3.2.120
·
1 row entry
·
11 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmlineNetworkLaneAlarmWarning2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmlineNetworkLaneAlarmWarning2Table'
List of pmlma10AlmlineNetworkLaneAlarmWarning2 Article
Row definition for the pmlma10AlmlineNetworkLaneAlarmWarning2
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmlineNetworkLaneAlarmWarning2
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.3.2.120.1.1 |
||||
|
Line Trscv Tx Power Low Warning
:This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv output power is lower than the… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.2 |
||||
|
Line Trscv Tx Power High Warning
:This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv output power is higher than … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.3 |
||||
|
Line Trscv Bias Low Warning :This
OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv laser bias current is lower … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.4 |
||||
|
Line Trscv Bias High Warning :This
OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv laser bias current is high… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.5 |
||||
|
Line Trscv Power Supply Low Warning
:This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv power supply is lower than… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.6 |
||||
|
Line Trscv Power Supply High Warning
:This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv power supply is higher t… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.7 |
||||
|
Line Trscv Temp Low Warning :This
OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv temperature is lower than the thresh… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.8 |
||||
|
Line Trscv Temp High Warning :This
OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv temperature is higher than the th… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.9 |
||||
|
Line Trscv Rx Power Low Warning
:This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv input power is lower than the t… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.16 |
||||
|
Line Trscv Rx Power High Warning
:This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv input power is higher than th… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.120.1.17 |
.1.3.6.1.4.1.20044.68.2.3.2.152
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmlineHostLaneFaultTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmlineHostLaneFaultTable'
List of pmlma10AlmlineHostLaneFault Article
Row definition for the pmlma10AlmlineHostLaneFault
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmlineHostLaneFault
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.3.2.152.1.1 |
||||
|
Line Input Loss Of Signal :This
OID indicates a Loss of Signal is detected on the Line Trscv <Help> Alarm indicating a Loss of Signal is detected on the Line Trscv <Condtype> LINE_INPUT_LOSS_OF_SIGNAL <Probcause> … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.152.1.2 |
||||
|
Line Loss Of Frame :This OID indicates
the module is not aligned with the incoming Line signal <Help> Alarm indicating the module is not aligned with the incoming Line signal <Condtype> LINE_LOSS_OF_FRAME <Probcau… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.152.1.3 |
||||
|
Line SM BDI Inserted :This OID
indicates a SM Backward Defect Indication is inserted on the outgoing Line signal <Help> Status indicating a SM Backward Defect Indication is inserted on the outgoing Line signal <Co… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.152.1.4 |
||||
|
Line SM BDI Detected :This OID
indicates a SM Backward Defect Indication is detected on the incoming Line signal <Help> Alarm indicating a SM Backward Defect Indication is detected on the incoming Line signal <Con… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.2.152.1.5 |
.1.3.6.1.4.1.20044.68.2.3.3.24
·
1 row entry
·
10 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10AlmsynthAlmLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10AlmsynthAlmLineTable'
List of pmlma10AlmsynthAlmLine Article
Row definition for the pmlma10AlmsynthAlmLine
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10AlmsynthAlmLine
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.2.3.3.24.1.1 |
||||
|
Line Optical Module Absent :This
OID indicates that the line optical interface is not present. <Help> This alarm indicates if the line transceiver is not plugged <Condtype> LINE_SFP_ABSENT_1 <Probcause> inputOutput… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.2 |
||||
|
Line Optical Module Ready :This
OID indicates that the optical interface is not operational. <Help> This status indicates if the line transceiver has been correctly initialized <Condtype> LINE_DDM_ABSENT_1 <Probca… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.3 |
||||
|
Line Port HW Failure :This OID
indicates a failure on line port, most probably caused by a HW issue <Help> This alarm indicates a failure on line port, most probably caused by a HW issue <Condtype> LINE_HW_FAIL <P… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.5 |
||||
|
Line Trscv Laser Shutdown :This
OID indicates the Line transceiver laser is shutdown <Help> This status indicates if the Line transceiver laser is shutdown <Condtype> LINE_TX_OFF <Probcause> other (1) <Alarmtype> … |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.6 |
||||
|
Line Port In Service :This OID
indicates that the Line port is In Service (1) of Out or Service (2) <Help> This status indicates if the line port is in service <Condtype> LINE_LOCAL_OOS <Probcause> informationalSt… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.7 |
||||
|
MS-RDI/L-RDI Inserted On Line
:This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. <Help> This status indicates if a MS-RDI/L-RDI is currently inserted on the li… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.9 |
||||
|
Warning On Line Optical Module
DDM :This OID indicates a warning is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Warning has been detected on the line transceiver <Condtype> LINE… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.10 |
||||
|
Alarm On Line Optical Module DDM
:This OID indicates an alarm is present coming out of Line transceiver DDM <Help> This alarm indicates if a DDM Alarm has been detected on the line transceiver <Condtype> LINE_DDM_… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.11 |
||||
|
Line Port Failure :This OID indicates
a failure on the line port <Help> This alarm indicates a failure on the line port <Condtype> LINE_FAIL <Probcause> equipmentMalfunction (16) <Alarmtype> synthesisAlarm (12) <… |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.2.3.3.24.1.13 |
.1.3.6.1.4.1.20044.68.3.2.16
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrclientTempTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrclientTempTable'
List of pmlma10MesrclientTemp Article
Row definition for the pmlma10MesrclientTemp
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrclientTemp
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.2.16.1.1 |
|
Client Optical Module Temperature
:This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This Measure give… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.2.16.1.2 |
.1.3.6.1.4.1.20044.68.3.2.32
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrclientTxBiasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrclientTxBiasTable'
List of pmlma10MesrclientTxBias Article
Row definition for the pmlma10MesrclientTxBias
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrclientTxBias
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.2.32.1.1 |
|
Client Optical Module Bias :This
OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This Measure gives the Laser bias val… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.2.32.1.2 |
.1.3.6.1.4.1.20044.68.3.2.48
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrclientTxPwrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrclientTxPwrTable'
List of pmlma10MesrclientTxPwr Article
Row definition for the pmlma10MesrclientTxPwr
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrclientTxPwr
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.2.48.1.1 |
|
Client Optical Module Tx Power
:This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives t… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.2.48.1.2 |
.1.3.6.1.4.1.20044.68.3.2.64
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrclientRxPwrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrclientRxPwrTable'
List of pmlma10MesrclientRxPwr Article
Row definition for the pmlma10MesrclientRxPwr
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrclientRxPwr
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.2.64.1.1 |
|
Client Optical Module Rx Power
:This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the … |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.2.64.1.2 |
.1.3.6.1.4.1.20044.68.3.3.80
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrlineTxPwrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrlineTxPwrTable'
List of pmlma10MesrlineTxPwr Article
Row definition for the pmlma10MesrlineTxPwr
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrlineTxPwr
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.3.80.1.1 |
|
Line Optical Module Tx Power :This
OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure give… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.3.80.1.2 |
pmlma10MesrlineTempTable
table.1.3.6.1.4.1.20044.68.3.3.96
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrlineTempTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrlineTempTable'
List of pmlma10MesrlineTemp Article
Row definition for the pmlma10MesrlineTemp
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrlineTemp
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.3.96.1.1 |
|
Line Optical Module Temperature
:This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) <Help> This Measure gives… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.3.96.1.2 |
.1.3.6.1.4.1.20044.68.3.3.112
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrlineTxBiasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrlineTxBiasTable'
List of pmlma10MesrlineTxBias Article
Row definition for the pmlma10MesrlineTxBias
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrlineTxBias
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.3.112.1.1 |
|
Line Optical Module Laser Bias
:This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) <Help> This Measure gives the Tx Laser … |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.3.112.1.2 |
.1.3.6.1.4.1.20044.68.3.3.128
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MesrlineRxPwrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MesrlineRxPwrTable'
List of pmlma10MesrlineRxPwr Article
Row definition for the pmlma10MesrlineRxPwr
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the pmlma10MesrlineRxPwr
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.3.3.128.1.1 |
|
Line Optical Module Rx Power :This
OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This Measure gives the Rece… |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.20044.68.3.3.128.1.2 |
.1.3.6.1.4.1.20044.68.4.2.96
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CntclientCbipCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CntclientCbipCounterTable'
List of pmlma10CntclientCbipCounter Article
Row definition for the pmlma10CntclientCbipCounter
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CntclientCbipCounter
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.4.2.96.1.1 |
||||
|
Client Output Errors :This counter
is incremented each time a CBIP parity error is detected on the Client output stream <Help> This counter gives the number of CBIP errors on the client port |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.20044.68.4.2.96.1.2 |
||||
|
Client Counter Error :This OID
when set indicates the CBIP error counter value is invalid on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.2.96.1.3 |
||||
|
Client CBIP Counter Overload :This
OID when set indicates a CBIP error counter overload on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.2.96.1.4 |
.1.3.6.1.4.1.20044.68.4.3.192
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CntlocalLineSmBip8ErrorCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CntlocalLineSmBip8ErrorCounterTable'
List of pmlma10CntlocalLineSmBip8ErrorCounter Article
Row definition for the pmlma10CntlocalLineSmBip8ErrorCounter
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CntlocalLineSmBip8ErrorCounter
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.4.3.192.1.1 |
||||
|
Line Input SM-BIP8 Errors :This
OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC <Help> This counter gives the current Bit Error Rate (residual SM-BIP8 error) after FEC |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.20044.68.4.3.192.1.2 |
||||
|
Line Counter Error :This OID when
set indicates the B1 error counter value is invalid on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.192.1.3 |
||||
|
Line Counter Overload :This OID
when set indicates a B1 error counter overload on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.192.1.4 |
.1.3.6.1.4.1.20044.68.4.3.200
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CntlocalLineFecCorrectedErrorsCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CntlocalLineFecCorrectedErrorsCounterTable'
List of pmlma10CntlocalLineFecCorrectedErrorsCounter Article
Row definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CntlocalLineFecCorrectedErrorsCounter
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.4.3.200.1.1 |
||||
|
Line Input HD FEC Corrected Errors
:This OID gives the current Bit Error Rate before the Hard Decision FEC <Help> This counter gives the current Bit Error Rate before the Hard Decision FEC |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.20044.68.4.3.200.1.2 |
||||
|
FEC Counter Error :This bit when
set indicates the FEC corrected errors counter value is invalid on Line |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.200.1.3 |
||||
|
FEC Counter Overload :This bit
when set indicates a FEC corrected errors counter overload on Line |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.200.1.4 |
.1.3.6.1.4.1.20044.68.4.3.208
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CntremoteLineSmBip8ErrorCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CntremoteLineSmBip8ErrorCounterTable'
List of pmlma10CntremoteLineSmBip8ErrorCounter Article
Row definition for the pmlma10CntremoteLineSmBip8ErrorCounter
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CntremoteLineSmBip8ErrorCounter
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.4.3.208.1.1 |
||||
|
Remote SM BIP8 :This OID gives
the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side <Help> This counter gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remot… |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.20044.68.4.3.208.1.2 |
||||
|
Remote Counter Error :
|
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.208.1.3 |
||||
|
Remote Counter Overload :
|
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.208.1.4 |
.1.3.6.1.4.1.20044.68.4.3.216
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CntlineDfrmTimCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CntlineDfrmTimCntTable'
List of pmlma10CntlineDfrmTimCnt Article
Row definition for the pmlma10CntlineDfrmTimCnt
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CntlineDfrmTimCnt
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.4.3.216.1.1 |
||||
|
Line Timer Counter :
|
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.20044.68.4.3.216.1.2 |
||||
|
Line Counter Error :This OID when
set indicates the deframer timer counter value is invalid on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.216.1.3 |
||||
|
Line Counter Overload :This OID
when set indicates a deframer timer counter overload on Port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.4.3.216.1.4 |
.1.3.6.1.4.1.20044.68.6.2.16
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlaccessLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlaccessLoopTable'
List of pmlma10CtrlaccessLoop Article
Row definition for the pmlma10CtrlaccessLoop
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlaccessLoop
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.2.16.1.1 |
||||
|
Client Facility Loopback :This
OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. <Help> This control enables the Out Loopback on the client… |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.2.16.1.2 |
.1.3.6.1.4.1.20044.68.6.2.17
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlclientLoopToLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlclientLoopToLineTable'
List of pmlma10CtrlclientLoopToLine Article
Row definition for the pmlma10CtrlclientLoopToLine
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlclientLoopToLine
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.2.17.1.1 |
||||
|
Client Terminal Loopback :This
OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control enables the In Loopback on the client port, looping the c… |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.2.17.1.2 |
pmlma10CtrlcsfUpInsTable
table.1.3.6.1.4.1.20044.68.6.2.21
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlcsfUpInsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlcsfUpInsTable'
List of pmlma10CtrlcsfUpIns Article
Row definition for the pmlma10CtrlcsfUpIns
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlcsfUpIns
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.2.21.1.1 |
||||
|
Client Signal Fail Insertion :This
OID, when set, inserts a client signal fail in the upstream client Port. <Help> This control inserts a Client Signal Fail for the client port |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.2.21.1.2 |
.1.3.6.1.4.1.20044.68.6.2.22
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlcaisDwInsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlcaisDwInsTable'
List of pmlma10CtrlcaisDwIns Article
Row definition for the pmlma10CtrlcaisDwIns
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlcaisDwIns
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.2.22.1.1 |
||||
|
Client AIS Insertion :This OID,
when set, inserts a client AIS on the downstream client Port. <Help> This control inserts a Client AIS for the client port |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.2.22.1.2 |
.1.3.6.1.4.1.20044.68.6.3.64
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlcommAccessLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlcommAccessLoopTable'
List of pmlma10CtrlcommAccessLoop Article
Row definition for the pmlma10CtrlcommAccessLoop
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlcommAccessLoop
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.3.64.1.1 |
||||
|
Line Terminal Loopback :This OID,
when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input.<Help> This control enables the In Loopback on the line port, looping … |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.3.64.1.2 |
pmlma10CtrllineLoopTable
table.1.3.6.1.4.1.20044.68.6.3.66
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrllineLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrllineLoopTable'
List of pmlma10CtrllineLoop Article
Row definition for the pmlma10CtrllineLoop
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrllineLoop
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.3.66.1.1 |
||||
|
Line Facility Loopback :This OID,
when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Upstream part of the module is timed on the 10 Gb/s … |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.3.66.1.2 |
.1.3.6.1.4.1.20044.68.6.3.69
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CtrlfecDisableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CtrlfecDisableTable'
List of pmlma10CtrlfecDisable Article
Row definition for the pmlma10CtrlfecDisable
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10CtrlfecDisable
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.6.3.69.1.1 |
||||
|
Forward Error Correction Inhibition
:This OID, when set, inhibits the Forward Error Correction feature on the line input <Help> This control enables/disables the Forward Error Correction on the line interface |
EKINOPS-MIBEkiStater/w Type Values:
|
.1.3.6.1.4.1.20044.68.6.3.69.1.2 |
pmlma10RinvSfpTable
table.1.3.6.1.4.1.20044.68.7.1.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10RinvSfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10RinvSfpTable'
List of the SFPs on the selected module
Row definition for the SFP table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index for SFP table
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.20044.68.7.1.1.1.1 |
|
Inventory for the SFP: This OID contains the inventory for the SFP
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.20044.68.7.1.1.1.2 |
pmlma10RinvLineTable
table.1.3.6.1.4.1.20044.68.7.1.2
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10RinvLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10RinvLineTable'
List of the XFPs on the selected module
Row definition for the XFP table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index for XFP table
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.20044.68.7.1.2.1.1 |
|
Inventory for the XFP: This OID contains the inventory for the XFP
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.20044.68.7.1.2.1.2 |
.1.3.6.1.4.1.20044.68.9.1.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgClientcaiscsfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgClientcaiscsfTable'
List of Article
Row definition for the accessCAisCsf
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the clientcaiscsf
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.1.1.1.1 |
|
CAIS mode on Client Port :This
register enables/disables port laser shutdown on CAIS insertion condition |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.1.1.1.3 |
.1.3.6.1.4.1.20044.68.9.2.1
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgClientStartupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgClientStartupTable'
List of Article
Row definition for the startup
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the clientStartup
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.2.1.1.1 |
|
Default Settings on Client Port
:This register configures the default initialisation settings on the port. |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.1.1.3 |
|
Default Settings on Client Port
:This register configures the default initialisation settings on the port. |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.1.1.4 |
|
Default Options on Client Port
:This register configures the default options on the port. |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.1.1.14 |
.1.3.6.1.4.1.20044.68.9.2.2
·
1 row entry
·
3 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgLinexr1StartupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgLinexr1StartupTable'
List of Article
Row definition for the startup
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the linexr1Startup
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.2.2.1.1 |
|
Default Settings on Line :This
register configures the default initialisation settings on Line |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.2.1.3 |
|
Default Options on Line :This
register configures the default options on the line |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.2.1.14 |
pmlma10CfgEmptyTable
table.1.3.6.1.4.1.20044.68.9.2.3
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgEmptyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgEmptyTable'
List of Article
Row definition for the startup
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the empty
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.2.3.1.1 |
|
Default settings on MSA :This
register configures the default initialisation settings on MSA |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.2.3.1.3 |
.1.3.6.1.4.1.20044.68.9.3.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgLabelclientTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgLabelclientTable'
List of Article
Row definition for the labels
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the labelclient
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.3.1.1.1 |
|
Default settings on the label
of the Ports :These registers configures the default initialisation settings of the labels of the ports. |
SNMPv2-TCDisplayStringr/w Constraints: range: 1-16Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.20044.68.9.3.1.1.3 |
pmlma10CfgLabellineTable
table.1.3.6.1.4.1.20044.68.9.3.2
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgLabellineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgLabellineTable'
List of Article
Row definition for the labels
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the labelline
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.3.2.1.1 |
|
Default settings on the label
of the lines :These registers configures the default initialisation settings of the labels of the lines. |
SNMPv2-TCDisplayStringr/w Constraints: range: 1-16Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.20044.68.9.3.2.1.3 |
pmlma10CfgOtxtlhTable
table.1.3.6.1.4.1.20044.68.9.4.1
·
1 row entry
·
6 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgOtxtlhTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgOtxtlhTable'
List of Article
Row definition for the startuptlh
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the otxtlh
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.4.1.1.1 |
|
Defaut Line output Power :This
register configures the start-up output power of the Line tranceiver (Unit = dBm) |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.4.1.1.6 |
|
Default Line transceiver Tx Channel
:This register configures the start-up laser channel of the Line Tx transceiver |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.4.1.1.7 |
|
Default Line transceiver Grid
:This register configures the start-up laser grid of the Line transceiver |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.4.1.1.8 |
|
Default Line TRX lowest Freq :This
register configures the start-up lowest frequency of the Line transceiver |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.4.1.1.9 |
|
Default Line transceiver Rx Channel
:This register configures the start-up laser channel of the Line Rx transceiver |
Unsigned32r/w Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.4.1.1.10 |
.1.3.6.1.4.1.20044.68.9.6.1
·
1 row entry
·
6 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10CfgOtxtlhcapabilitiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10CfgOtxtlhcapabilitiesTable'
List of Article
Row definition for the startuptablefive
table
table
| Column | Syntax | OID |
|---|---|---|
|
Index definition for the otxtlhcapabilities
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.9.6.1.1.1 |
|
Component parameters :This OID
defines the component parameters |
Unsigned32 Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.6.1.1.3 |
|
Miscellaneous default settings
:This OID defines the miscellaneous parameters |
Unsigned32 Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.6.1.1.4 |
|
Number of the first channel of
the component :This OID defines the first channel number of the PM |
Unsigned32 Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.6.1.1.5 |
|
Number of the last channel of
the component :This OID defines the last channel number of the PM |
Unsigned32 Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.6.1.1.6 |
|
Grid value of the component :This
OID defines the grid of the PM |
Unsigned32 Constraints: range: 0-65536 |
.1.3.6.1.4.1.20044.68.9.6.1.1.7 |
.1.3.6.1.4.1.20044.68.11.2.4.16
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonBytesCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonBytesCounterClientInputTable'
List of pmlma10MonupRmonBytesCounterClientInput Article
Row definition for the pmlma10MonupRmonBytesCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonBytesCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.16.1.1 |
||||
|
Client Input Bytes :This counter
is increased each time a data byte is received on the client port <Help> This counter gives the number of bytes received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.16.1.2 |
||||
|
Bytes Counter Error :This OID
when set indicates the Bytes counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.16.1.3 |
||||
|
Bytes Counter Overload :This OID
when set indicates a Bytes counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.16.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.32
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonCrcErrorsCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonCrcErrorsCounterClientInputTable'
List of pmlma10MonupRmonCrcErrorsCounterClientInput Article
Row definition for the pmlma10MonupRmonCrcErrorsCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonCrcErrorsCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.32.1.1 |
||||
|
Client Input B1/CRC Errors :This
counter is increased each time a B1/FCS error is detected on the client port <Help> This counter gives the number of B1/FCS Errors received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.32.1.2 |
||||
|
B1/FCS Errors Counter Error :This
OID when set indicates the B1/FCS Errors counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.32.1.3 |
||||
|
B1/FCS Errors Counter Overload
:This OID when set indicates a B1/FCS Errors counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.32.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.48
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonPacketsCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonPacketsCounterClientInputTable'
List of pmlma10MonupRmonPacketsCounterClientInput Article
Row definition for the pmlma10MonupRmonPacketsCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonPacketsCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.48.1.1 |
||||
|
Client Input Packets :This counter
is increased each time a packet is received on the client port <Help> This counter gives the number of packets received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.48.1.2 |
||||
|
Packets Counter Error :This OID
when set indicates the Packets counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.48.1.3 |
||||
|
Packets Counter Overload :This
OID when set indicates a Packets counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.48.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.64
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonBroadcastCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonBroadcastCounterClientInputTable'
List of pmlma10MonupRmonBroadcastCounterClientInput Article
Row definition for the pmlma10MonupRmonBroadcastCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonBroadcastCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.64.1.1 |
||||
|
Client Input Broadcast Packets
:This counter is increased each time a broadcast packet is received on the client port <Help> This counter gives the number of Broadcast packets received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.64.1.2 |
||||
|
Broadcast Counter Error :This
OID when set indicates the Broadcast counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.64.1.3 |
||||
|
Broadcast Counter Overload :This
OID when set indicates a Broadcast counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.64.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.80
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonMulticastCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonMulticastCounterClientInputTable'
List of pmlma10MonupRmonMulticastCounterClientInput Article
Row definition for the pmlma10MonupRmonMulticastCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonMulticastCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.80.1.1 |
||||
|
Client Input Multicast Packets
:This counter is increased each time a Multicast packet is received on the client port <Help> This counter gives the number of Multicast packets received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.80.1.2 |
||||
|
Multicast Counter Error :This
OID when set indicates the Multicast counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.80.1.3 |
||||
|
Multicast Counter Overload :This
OID when set indicates a Multicast counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.80.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.96
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MonupRmonPauseFrameCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MonupRmonPauseFrameCounterClientInputTable'
List of pmlma10MonupRmonPauseFrameCounterClientInput Article
Row definition for the pmlma10MonupRmonPauseFrameCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MonupRmonPauseFrameCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.96.1.1 |
||||
|
Client Input Pause Frames :This
counter is increased each time a Pause frame is received on the client port <Help> This counter gives the number of Pause frames received on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.96.1.2 |
||||
|
Pause Counter Error :This OID
when set indicates the Pause counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.96.1.3 |
||||
|
Pause Counter Overload :This OID
when set indicates a Pause counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.96.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.224
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MondwRmonCrcErrorsCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MondwRmonCrcErrorsCounterClientInputTable'
List of pmlma10MondwRmonCrcErrorsCounterClientInput Article
Row definition for the pmlma10MondwRmonCrcErrorsCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MondwRmonCrcErrorsCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.224.1.1 |
||||
|
Client Output B1/CRC Errors :This
counter is increased each time a B1/FCS error is detected on the output client port <Help> This counter gives the number of B1/CRC Errors detected on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.224.1.2 |
||||
|
Output B1/FCS Errors Counter Error
:This OID when set indicates the output B1/FCS Errors counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.224.1.3 |
||||
|
Output B1/FCS Errors Counter Overload
:This OID when set indicates an output B1/FCS Errors counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.224.1.4 |
.1.3.6.1.4.1.20044.68.11.2.4.240
·
1 row entry
·
4 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmlma10MondwRmonPacketsCounterClientInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmlma10-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmlma10-MIB::pmlma10MondwRmonPacketsCounterClientInputTable'
List of pmlma10MondwRmonPacketsCounterClientInput Article
Row definition for the pmlma10MondwRmonPacketsCounterClientInput
table
table
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index definition for the pmlma10MondwRmonPacketsCounterClientInput
table |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.20044.68.11.2.4.240.1.1 |
||||
|
Client Output Packets :This counter
is increased each time a packet is transmitted on the client port. <Help> This counter gives the number of packets detected on the client port |
SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 |
.1.3.6.1.4.1.20044.68.11.2.4.240.1.2 |
||||
|
Output Packets Counter Error :This
OID when set indicates the output Packets counter value is invalid on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.240.1.3 |
||||
|
Output Packets Counter Overload
:This OID when set indicates an output Packets counter overload on client port |
EKINOPS-MIBEkiOnOff Type Values:
|
.1.3.6.1.4.1.20044.68.11.2.4.240.1.4 |