EATON-EPDU-MA-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
33
outletTable
table.1.3.6.1.4.1.534.6.6.6.1.2.2
·
1 row entry
·
11 columns
Uses the eaton variant from
Command help
/opt/observium/mibs/eaton.
Walk outletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EATON-EPDU-MA-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EATON-EPDU-MA-MIB::outletTable'
A list of outlet entries. The number of entries is given by the value of outletCount.
An outlet entry containing objects at the
for a particular outlet.
for a particular outlet.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each outlet. Its value
ranges between 1 and the value of outletCount. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.1 |
||||||||
|
A textual string containing information
about the outlet. |
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.2 |
||||||||
|
A value for each outlet which describes the
operational state of the outlet. It is also used to set the operational state of the outlet |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.3 |
||||||||
|
A unique value for the current sensor
attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
MilliAmps | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.4 |
||||||||
|
A unique value for the max. current sensor
attached to the outlet. This value is reported in milliamps (1/1000th of an amp) |
MilliAmps | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.5 |
||||||||
|
A unique value for the voltage sensor
attached to the outlet.This value is reported in millivolts (1/1000th of a volt) |
MilliVolts | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.6 |
||||||||
|
A unique value for the active power sensor
attached to the outlet. This value is reported in Watts. |
Watts | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.7 |
||||||||
|
A unique value for the apparent power sensor
attached to the outlet. This value is reported in Volt-Amps |
VoltAmps | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.8 |
||||||||
|
A unique value for the power factor
of the outlet. The reading represents a percentage in the range of 0% to 100%. |
PowerFactorPercentage Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.9 |
||||||||
|
The value of the upper warning (non-critical)
current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
MilliAmpsr/w | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.21 |
||||||||
|
The value of the upper critical current
threshold for the outlet. This value is reported in milliamps (1/1000th of an amp) |
MilliAmpsr/w | .1.3.6.1.4.1.534.6.6.6.1.2.2.1.23 |
tempSensorTable
table.1.3.6.1.4.1.534.6.6.6.2.2
·
1 row entry
·
11 columns
Uses the eaton variant from
Command help
/opt/observium/mibs/eaton.
Walk tempSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EATON-EPDU-MA-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EATON-EPDU-MA-MIB::tempSensorTable'
A list of temperature sensor entries. The number of entries is given by the value of tempSensorCount.
An entry containing sensor reading and threshold
settings for a particular temperature sensor.
settings for a particular temperature sensor.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each temperature sensor. Its value
ranges between 1 and tempSensorCount. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.534.6.6.6.2.2.1.1 |
|
A settable human-readable label for the external temperature
sensor. One possible use for this label is to convey sensor location. |
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.534.6.6.6.2.2.1.2 |
|
The value of the external temperature sensor reported
in degrees celsius. |
DegreesCelsius | .1.3.6.1.4.1.534.6.6.6.2.2.1.3 |
|
The value of the lower warning (non-critical) threshold.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.4 |
|
The value of the upper warning (non-critical) threshold.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.5 |
|
The value of the lower critical threshold.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.6 |
|
The value of the upper critical threshold.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.7 |
|
The value of the lower warning (non-critical) reset/hysteresis value.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.8 |
|
The value of the upper warning (non-critical) reset/hysteresis value.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.9 |
|
The value of the lower critical reset/hysteresis value.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.10 |
|
The value of the upper critical reset/hysteresis value.
|
DegreesCelsiusr/w | .1.3.6.1.4.1.534.6.6.6.2.2.1.11 |
humiditySensorTable
table.1.3.6.1.4.1.534.6.6.6.2.4
·
1 row entry
·
11 columns
Uses the eaton variant from
Command help
/opt/observium/mibs/eaton.
Walk humiditySensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EATON-EPDU-MA-MIB' -M '/opt/observium/mibs/eaton:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EATON-EPDU-MA-MIB::humiditySensorTable'
A list of humidity sensor entries. The number of entries is given by the value of humiditySensorCount.
An entry containing sensor reading and threshold
settings for a particular humidity sensor.
settings for a particular humidity sensor.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each humidity sensor. Its value
ranges between 1 and humiditySensorCount. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.1 |
|
A settable human-readable label for the external humidity
sensor. One possible use for this label is to convey sensor location. |
SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.534.6.6.6.2.4.1.2 |
|
The value of the external humidity sensor reported
as relative humidity (a percentage). |
RelativeHumidity Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.3 |
|
The value of the lower warning (non-critical) threshold.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.4 |
|
The value of the upper warning (non-critical) threshold.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.5 |
|
The value of the lower critical threshold.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.6 |
|
The value of the upper critical threshold.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.7 |
|
The value of the lower warning (non-critical) reset/hysteresis value.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.8 |
|
The value of the upper warning (non-critical) reset/hysteresis value.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.9 |
|
The value of the lower critical reset/hysteresis value.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.10 |
|
The value of the upper critical reset/hysteresis value.
|
RelativeHumidityr/w Type Constraints: range: 0..100 |
.1.3.6.1.4.1.534.6.6.6.2.4.1.11 |