DNOS-DEVICE-FILESYSTEM-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
18
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1
·
1 row entry
·
14 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk agentDeviceFileSystemTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-DEVICE-FILESYSTEM-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-DEVICE-FILESYSTEM-MIB::agentDeviceFileSystemTable'
DeviceFileSystem Table
DeviceFileSystem entry
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Describes the index of FileSystem device plugged into the switch.
|
Integer32 Constraints: range: 1-9 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.1 |
||||||
|
Describes the current status of FileSystem device plugged into the switch.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.2 |
||||||
|
DeviceFileSystem vendor ID.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.3 |
||||||
|
DeviceFileSystem Product ID.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.4 |
||||||
|
DeviceFileSystem Manufacturer.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.5 |
||||||
|
DeviceFileSystem Serial Number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.6 |
||||||
|
DeviceFileSystem Version.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.7 |
||||||
|
DeviceFileSystem Protocol
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.8 |
||||||
|
DeviceFileSystem Class.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.9 |
||||||
|
DeviceFileSystem SubClass.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.10 |
||||||
|
DeviceFileSystem storage size
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.11 |
||||||
|
Indicates size of memory used on the DeviceFileSystem.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.12 |
||||||
|
Indicates size of memory free on the USB flash drive device.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.13 |
||||||
|
Used to make the DeviceFileSystem Inactive by sending unmount(1). Get operation is invalid for this object. It just returns none(0)
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.1.1.14 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.2
·
1 row entry
·
4 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk agentDeviceFileSystemContentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-DEVICE-FILESYSTEM-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-DEVICE-FILESYSTEM-MIB::agentDeviceFileSystemContentTable'
Table display DeviceFileSystem contents
DeviceFileSystem Content, Refers to each File
| Column | Syntax | OID |
|---|---|---|
|
Describes the index of FileSystem device plugged into the switch.
|
Integer32 Constraints: range: 1-9 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.2.1.1 |
|
Name of the file stored in DeviceFileSystem
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.2.1.2 |
|
Size of the file stored in DeviceFileSystem
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.2.1.3 |
|
Last modification time of the file stored in DeviceFileSystem
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.44.1.2.1.4 |