DMOS-HW-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
18
.1.3.6.1.4.1.3709.3.6.6.1.1 · 1 row entry · 1 columns
Uses the datacom variant from /opt/observium/mibs/datacom.
Command help
Walk environmentChassisTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::environmentChassisTable'
List of chassis for which thermal management information is available
environmentChassisEntry row .1.3.6.1.4.1.3709.3.6.6.1.1.1
Chassis identification field
Column Syntax OID
Chassis identifier
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3709.3.6.6.1.1.1.1
.1.3.6.1.4.1.3709.3.6.6.1.2 · 1 row entry · 1 columns
Uses the datacom variant from /opt/observium/mibs/datacom.
Command help
Walk environmentSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::environmentSlotTable'
List of slots for which thermal management information is available
environmentSlotEntry row .1.3.6.1.4.1.3709.3.6.6.1.2.1
Slot thermal information structure
Column Syntax OID
Slot identifier
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.2.1.1
.1.3.6.1.4.1.3709.3.6.6.1.3 · 1 row entry · 8 columns
Uses the datacom variant from /opt/observium/mibs/datacom.
Command help
Walk temperatureSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::temperatureSensorTable'
List of temperature sensors present on a given slot and chassis
temperatureSensorEntry row .1.3.6.1.4.1.3709.3.6.6.1.3.1
Temperature sensor information structure
Column Syntax OID
Temperature sensor identifier
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.3.1.1
Temperature sensor description
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.3.1.2
High temperature alarm threshold
CEnvironmentSensorTemperature .1.3.6.1.4.1.3709.3.6.6.1.3.1.3
Low temperature alarm threshold
CEnvironmentSensorTemperature .1.3.6.1.4.1.3709.3.6.6.1.3.1.4
Hysteresis value for both high and low temperature alarms
CEnvironmentSensorTemperature .1.3.6.1.4.1.3709.3.6.6.1.3.1.5
Current temperature value being read by the sensor
CEnvironmentSensorTemperature .1.3.6.1.4.1.3709.3.6.6.1.3.1.6
Indicates if an error occured while trying to read from the sensor
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3709.3.6.6.1.3.1.7
Temperature status based on minimum and maximum thresholds
EnvironmentSensorStatus
Type Values:
-2fail
-1error
0normal
1high
2low
3critical
.1.3.6.1.4.1.3709.3.6.6.1.3.1.8

fanTable

table
.1.3.6.1.4.1.3709.3.6.6.1.4 · 1 row entry · 6 columns
Uses the datacom variant from /opt/observium/mibs/datacom.
Command help
Walk fanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::fanTable'
List of individual fans manageable on a given fan module/slot
fanEntry row .1.3.6.1.4.1.3709.3.6.6.1.4.1
Fan information structure
Column Syntax OID
Fan identifier
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.4.1.1
Fan description
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.4.1.2
Percentage of maximum fan speed applied for thermal control
%DMOS-TC-MIBUnsignedPercent
Type Constraints:
range: 0..100
.1.3.6.1.4.1.3709.3.6.6.1.4.1.3
Current speed of the fan
RPMSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3709.3.6.6.1.4.1.4
Indicates if an error occured while trying to read from the sensor
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3709.3.6.6.1.4.1.5
Indicates the current state of the fan based on its speed
EnvironmentSensorStatus
Type Values:
-2fail
-1error
0normal
1high
2low
3critical
.1.3.6.1.4.1.3709.3.6.6.1.4.1.6

psuTable

table
.1.3.6.1.4.1.3709.3.6.6.1.5 · 1 row entry · 2 columns
Uses the datacom variant from /opt/observium/mibs/datacom.
Command help
Walk psuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::psuTable'
List of Power Supply Units
psuEntry row .1.3.6.1.4.1.3709.3.6.6.1.5.1
Power Supply Unit information structure
Indexes
Column Syntax OID
Power Supply Unit identifier
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.3709.3.6.6.1.5.1.1
Indicates the current state of the PSU
Enumeration
Enumerated Values:
0ok
1powerInputFailure
2fuseFailure
3error
.1.3.6.1.4.1.3709.3.6.6.1.5.1.2