DMOS-HW-MONITOR-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
18
environmentChassisTable
table.1.3.6.1.4.1.3709.3.6.6.1.1
·
1 row entry
·
1 columns
Uses the datacom variant from
Command help
/opt/observium/mibs/datacom.
Walk environmentChassisTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::environmentChassisTable'
List of chassis for which thermal management information is available
Chassis identification field
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Chassis identifier
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3709.3.6.6.1.1.1.1 |
environmentSlotTable
table.1.3.6.1.4.1.3709.3.6.6.1.2
·
1 row entry
·
1 columns
Uses the datacom variant from
Command help
/opt/observium/mibs/datacom.
Walk environmentSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::environmentSlotTable'
List of slots for which thermal management information is available
Slot thermal information structure
| Column | Syntax | OID |
|---|---|---|
|
Slot identifier
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.2.1.1 |
temperatureSensorTable
table.1.3.6.1.4.1.3709.3.6.6.1.3
·
1 row entry
·
8 columns
Uses the datacom variant from
Command help
/opt/observium/mibs/datacom.
Walk temperatureSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::temperatureSensorTable'
List of temperature sensors present on a given slot and chassis
Temperature sensor information structure
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Temperature sensor identifier
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.3.1.1 |
||||||||||||
|
Temperature sensor description
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.3.1.2 |
||||||||||||
|
High temperature alarm threshold
|
CEnvironmentSensorTemperature | .1.3.6.1.4.1.3709.3.6.6.1.3.1.3 |
||||||||||||
|
Low temperature alarm threshold
|
CEnvironmentSensorTemperature | .1.3.6.1.4.1.3709.3.6.6.1.3.1.4 |
||||||||||||
|
Hysteresis value for both high and low temperature alarms
|
CEnvironmentSensorTemperature | .1.3.6.1.4.1.3709.3.6.6.1.3.1.5 |
||||||||||||
|
Current temperature value being read by the sensor
|
CEnvironmentSensorTemperature | .1.3.6.1.4.1.3709.3.6.6.1.3.1.6 |
||||||||||||
|
Indicates if an error occured while trying to read from the sensor
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.3709.3.6.6.1.3.1.7 |
||||||||||||
|
Temperature status based on minimum and maximum thresholds
|
EnvironmentSensorStatus Type Values:
|
.1.3.6.1.4.1.3709.3.6.6.1.3.1.8 |
fanTable
table.1.3.6.1.4.1.3709.3.6.6.1.4
·
1 row entry
·
6 columns
Uses the datacom variant from
Command help
/opt/observium/mibs/datacom.
Walk fanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::fanTable'
List of individual fans manageable on a given fan module/slot
Fan information structure
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Fan identifier
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.4.1.1 |
||||||||||||
|
Fan description
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.4.1.2 |
||||||||||||
|
Percentage of maximum fan speed applied for thermal control
|
%DMOS-TC-MIBUnsignedPercent Type Constraints: range: 0..100 |
.1.3.6.1.4.1.3709.3.6.6.1.4.1.3 |
||||||||||||
|
Current speed of the fan
|
RPMSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3709.3.6.6.1.4.1.4 |
||||||||||||
|
Indicates if an error occured while trying to read from the sensor
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.3709.3.6.6.1.4.1.5 |
||||||||||||
|
Indicates the current state of the fan based on its speed
|
EnvironmentSensorStatus Type Values:
|
.1.3.6.1.4.1.3709.3.6.6.1.4.1.6 |
psuTable
table.1.3.6.1.4.1.3709.3.6.6.1.5
·
1 row entry
·
2 columns
Uses the datacom variant from
Command help
/opt/observium/mibs/datacom.
Walk psuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DMOS-HW-MONITOR-MIB' -M '/opt/observium/mibs/datacom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DMOS-HW-MONITOR-MIB::psuTable'
List of Power Supply Units
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Power Supply Unit identifier
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3709.3.6.6.1.5.1.1 |
||||||||
|
Indicates the current state of the PSU
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3709.3.6.6.1.5.1.2 |