DGS-6600-EQUIPMENT-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
6
Rows
6
Columns
43
.1.3.6.1.4.1.171.10.120.100.1.2.1.1
·
1 row entry
·
6 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisControlModuleLEDInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisControlModuleLEDInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object indicates the slot index of Control Module.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.1 |
||||||||||||||||||
|
This object indicates the console type. There are two different interfaces:
1: RS232. 2: USB. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.2 |
||||||||||||||||||
|
This object indicates whether this control module is master or not?
1: This control module is active CM. 2: This control module is standby CM. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.3 |
||||||||||||||||||
|
This object indicates the CPU utilization(in percentage) of this control module.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.4 |
||||||||||||||||||
|
This object indicates the management port status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.5 |
||||||||||||||||||
|
This object indicates the management port link speed.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.6 |
chassisPowerInfoTable
table.1.3.6.1.4.1.171.10.120.100.1.2.2.1
·
1 row entry
·
7 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisPowerInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisPowerInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
This object indicates the PSU index.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.1 |
||||
|
This object indicates whether the specified PSU is exist or not.
1: The PSU is not exist. 2: The PSU is installed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.2 |
||||
|
This object indicates whether the specified PSU is alive or not.
1: The PSU is not available. 2: The PSU is working normally. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.4 |
||||
|
This object indicates the output voltage(V) of the specified PSU.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.5 |
||||
|
This object indicates the output current(mA) of the specified PSU.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.6 |
||||
|
This object indicates the output power(W) of the specified PSU.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.7 |
||||
|
This object indicates the internal fan speed(rpm) of specified PSU.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.8 |
chassisFanInfoTable
table.1.3.6.1.4.1.171.10.120.100.1.2.3.2
·
1 row entry
·
3 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisFanInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisFanInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
This object indicates the fan tray index.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.1 |
||||
|
This object indicates the fan status(ok or failed).
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.2 |
||||
|
This object indicates the fan speed in RPM.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.3 |
chassisSlotInfoTable
table.1.3.6.1.4.1.171.10.120.100.1.2.4.1
·
1 row entry
·
12 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisSlotInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisSlotInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object indicates the slot index.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.1 |
||||||||||
|
This object indicates the slot state:
1: The slot has no card installed. 2: The card which installed at this slot is not powered up. 3: The card which installed at this slot is failed. 4: The card which installed at thi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.2 |
||||||||||
|
This object indicates whether the PoE mode is enabled or not?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.3 |
||||||||||
|
This object indicates the card model name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.4 |
||||||||||
|
This object indicates the serial number of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.5 |
||||||||||
|
This object indicates the HW version of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.6 |
||||||||||
|
This object indicates the PCBA version of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.7 |
||||||||||
|
This object indicates the PCBA version of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.8 |
||||||||||
|
This object indicates the runtime version of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.9 |
||||||||||
|
This object indicates the CPLD version of the installed card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.10 |
||||||||||
|
This object indicates the first MAC address of the installed card.
|
SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.11 |
||||||||||
|
This object indicates the number of MAC address of the installed card.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.12 |
.1.3.6.1.4.1.171.10.120.100.1.2.5.1
·
1 row entry
·
10 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisTemperatureInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisTemperatureInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
This object indicates the slot number which is currently querying.
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.1 |
|
This object displays the current temperature of Inlet sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.2 |
|
This object displays the overheat threshold of Inlet sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.3 |
|
This object displays the heatdown threshold of Inlet sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.4 |
|
This object displays the current temperature of Center sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.5 |
|
This object displays the overheat threshold of Center sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.6 |
|
This object displays the heatdown threshold of Center sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.7 |
|
This object displays the current temperature of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.8 |
|
This object displays the overheat threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.9 |
|
This object displays the outlet threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.10 |
chassisPortLEDInfoTable
table.1.3.6.1.4.1.171.10.120.100.1.2.6.1
·
1 row entry
·
5 columns
Uses the d-link variant from
Command help
/opt/observium/mibs/d-link.
Walk chassisPortLEDInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisPortLEDInfoTable'
TBD.
TBD.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
This object indicates the interface index.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.1 |
||||||||||
|
This object indicates the interface name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.2 |
||||||||||
|
This object indicates the port LED status:
1: The port LED status of the interface index is off. 2: The port LED status of the interface index is steady-amber. 3: The port LED status of the interface index is steady-gr… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.3 |
||||||||||
|
This object indicates the port LED mode:
1: The port LED is in Ethernet mode. 2: The poer LED is in PoE mode. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.4 |
||||||||||
|
This object indicates the port LED medium type:
1: The medium type of port LED is copper. 2: The medium type of port LED is fiber. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.5 |