DGS-6600-EQUIPMENT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
43
.1.3.6.1.4.1.171.10.120.100.1.2.1.1 · 1 row entry · 6 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisControlModuleLEDInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisControlModuleLEDInfoTable'
TBD.
chassisControlModuleLEDInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.1.1.1
TBD.
Column Syntax OID
This object indicates the slot index of Control Module.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.1
This object indicates the console type. There are two different interfaces:
1: RS232.
2: USB.
Enumeration
Enumerated Values:
1rs232
2usb
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.2
This object indicates whether this control module is master or not?
1: This control module is active CM.
2: This control module is standby CM.
Enumeration
Enumerated Values:
1active
2standby
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.3
This object indicates the CPU utilization(in percentage) of this control module.
Enumeration
Enumerated Values:
0zero-LED
1one-LED
2two-LEDs
3three-LEDs
4four-LEDs
5five-LEDs
6six-LEDs
7seven-LEDs
8eight-LEDs
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.4
This object indicates the management port status.
Enumeration
Enumerated Values:
1off
2steady-green
3blinking-green
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.5
This object indicates the management port link speed.
Enumeration
Enumerated Values:
1link-0
2link-100
3link-1000
.1.3.6.1.4.1.171.10.120.100.1.2.1.1.1.6
.1.3.6.1.4.1.171.10.120.100.1.2.2.1 · 1 row entry · 7 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisPowerInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisPowerInfoTable'
TBD.
chassisPowerInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.2.1.1
TBD.
Column Syntax OID
This object indicates the PSU index.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.1
This object indicates whether the specified PSU is exist or not.
1: The PSU is not exist.
2: The PSU is installed.
Enumeration
Enumerated Values:
1empty
2exist
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.2
This object indicates whether the specified PSU is alive or not.
1: The PSU is not available.
2: The PSU is working normally.
Enumeration
Enumerated Values:
1failed
2in-operation
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.4
This object indicates the output voltage(V) of the specified PSU.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.5
This object indicates the output current(mA) of the specified PSU.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.6
This object indicates the output power(W) of the specified PSU.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.7
This object indicates the internal fan speed(rpm) of specified PSU.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.2.1.1.8
.1.3.6.1.4.1.171.10.120.100.1.2.3.2 · 1 row entry · 3 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisFanInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisFanInfoTable'
TBD.
chassisFanInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.3.2.1
TBD.
Indexes
Column Syntax OID
This object indicates the fan tray index.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.1
This object indicates the fan status(ok or failed).
Enumeration
Enumerated Values:
1failed
2ok
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.2
This object indicates the fan speed in RPM.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.3.2.1.3
.1.3.6.1.4.1.171.10.120.100.1.2.4.1 · 1 row entry · 12 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisSlotInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisSlotInfoTable'
TBD.
chassisSlotInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1
TBD.
Column Syntax OID
This object indicates the slot index.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.1
This object indicates the slot state:
1: The slot has no card installed.
2: The card which installed at this slot is not powered up.
3: The card which installed at this slot is failed.
4: The card which installed at thi…
Enumeration
Enumerated Values:
1empty
2no-power
3failed
4booting
5in-operation
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.2
This object indicates whether the PoE mode is enabled or not?
Enumeration
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.3
This object indicates the card model name.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.4
This object indicates the serial number of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.5
This object indicates the HW version of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.6
This object indicates the PCBA version of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.7
This object indicates the PCBA version of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.8
This object indicates the runtime version of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.9
This object indicates the CPLD version of the installed card.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.10
This object indicates the first MAC address of the installed card.
SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.11
This object indicates the number of MAC address of the installed card.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.4.1.1.12
.1.3.6.1.4.1.171.10.120.100.1.2.5.1 · 1 row entry · 10 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisTemperatureInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisTemperatureInfoTable'
TBD.
chassisTemperatureInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1
TBD.
Column Syntax OID
This object indicates the slot number which is currently querying.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.1
This object displays the current temperature of Inlet sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.2
This object displays the overheat threshold of Inlet sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.3
This object displays the heatdown threshold of Inlet sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.4
This object displays the current temperature of Center sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.5
This object displays the overheat threshold of Center sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.6
This object displays the heatdown threshold of Center sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.7
This object displays the current temperature of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.8
This object displays the overheat threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.9
This object displays the outlet threshold of Outlet sensor.
The string N/A will be displayed to indicate that the card has no this sensor.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.5.1.1.10
.1.3.6.1.4.1.171.10.120.100.1.2.6.1 · 1 row entry · 5 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk chassisPortLEDInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DGS-6600-EQUIPMENT-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DGS-6600-EQUIPMENT-MIB::chassisPortLEDInfoTable'
TBD.
chassisPortLEDInfoEntry row .1.3.6.1.4.1.171.10.120.100.1.2.6.1.1
TBD.
Column Syntax OID
This object indicates the interface index.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.1
This object indicates the interface name.
RFC1213-MIBDisplayString .1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.2
This object indicates the port LED status:
1: The port LED status of the interface index is off.
2: The port LED status of the interface index is steady-amber.
3: The port LED status of the interface index is steady-gr…
Enumeration
Enumerated Values:
1off
2steady-amber
3steady-green
4blinking-amber
5blinking-green
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.3
This object indicates the port LED mode:
1: The port LED is in Ethernet mode.
2: The poer LED is in PoE mode.
Enumeration
Enumerated Values:
1ethernet
2poe
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.4
This object indicates the port LED medium type:
1: The medium type of port LED is copper.
2: The medium type of port LED is fiber.
Enumeration
Enumerated Values:
1copper
2fiber
.1.3.6.1.4.1.171.10.120.100.1.2.6.1.1.5