DELL-MM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
17

dmmPowerTable

table mandatory
.1.3.6.1.4.1.674.10892.6.4.1 · 1 row entry · 9 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk dmmPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELL-MM-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELL-MM-MIB::dmmPowerTable'
This object defines the power table.
dmmPowerTableEntry row .1.3.6.1.4.1.674.10892.6.4.1.1
This object defines the power table entry.
Column Syntax OID
This attribute defines the index
(one-based) of the associated chassis.
DellPowerIndexRange
Type Constraints:
range: 1
.1.3.6.1.4.1.674.10892.6.4.1.1.1
This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the minimum power requirements
for all currently powered-on servers.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.1.1.2
This attribute defines the cumulative chassis power
usage (in KWh) since last reset.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.1.1.3
This attribute defines the timestamp of the most recent
chassis power accumulator reset.
DellTimestamp
Type Constraints:
range: 26
.1.3.6.1.4.1.674.10892.6.4.1.1.4
This attribute defines the chassis peak power
usage (in Watts) since last reset.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.1.1.5
This attribute defines the timestamp of the most recent
chassis peak power usage.
DellTimestamp
Type Constraints:
range: 26
.1.3.6.1.4.1.674.10892.6.4.1.1.6
This attribute defines the chassis mimimum power
usage (in Watts) since last reset.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.1.1.7
This attribute defines the timestamp of the most recent
chassis minimum power usage.
DellTimestamp
Type Constraints:
range: 26
.1.3.6.1.4.1.674.10892.6.4.1.1.8
This attribute defines the instantaneous chassis power
usage (in Watts).
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.1.1.9

dmmPSUTable

table mandatory
.1.3.6.1.4.1.674.10892.6.4.2 · 1 row entry · 8 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk dmmPSUTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELL-MM-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELL-MM-MIB::dmmPSUTable'
This object defines the PSU table.
dmmPSUTableEntry row .1.3.6.1.4.1.674.10892.6.4.2.1
This object defines the PSU table entry.
Column Syntax OID
This attribute defines the index
(one-based) of the associated chassis.
DellPowerIndexRange
Type Constraints:
range: 1
.1.3.6.1.4.1.674.10892.6.4.2.1.1
dmmPSUIndexmandatory
This attribute defines the index
(one-based) of the associated PSU.
DellPSUIndexRange
Type Constraints:
range: 1..6
.1.3.6.1.4.1.674.10892.6.4.2.1.2
This attribute defines the location
of the PSU.
DellString
Type Constraints:
range: 0..1023
.1.3.6.1.4.1.674.10892.6.4.2.1.3
dmmPSUStatemandatory
This attribute defines the enabled state of
of the PSU.
DellString
Type Constraints:
range: 0..1023
.1.3.6.1.4.1.674.10892.6.4.2.1.4
dmmPSUTypemandatory
This attribute defines the type
of the PSU.
DellString
Type Constraints:
range: 0..1023
.1.3.6.1.4.1.674.10892.6.4.2.1.5
This attribute defines the capacity in watts
of the PSU.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.2.1.6
dmmPSUVoltagemandatory
This attribute defines the input voltage
of the PSU.
DellPowerReading
Type Constraints:
range: 0..32
.1.3.6.1.4.1.674.10892.6.4.2.1.7
This attribute defines the current status
of the PSU.
DellStatus
Type Values:
1other
2unknown
3ok
4nonCritical
5critical
6nonRecoverable
.1.3.6.1.4.1.674.10892.6.4.2.1.8