configTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.2 · 1 row entry · 7 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk configTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTTRAPLOG-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTTRAPLOG-MIB::configTable'
configTableEntry row .1.3.6.1.4.1.52.4.1.44.2.1
Each entry allows a user to configure the alarm table
for a specific slot. Objects such as Current Entry,
MaxEntries Allowed, and an Enable/Disable switch are
available.
Indexes
Column Syntax OID
slotInChassismandatory
Each Slot can be separately configured. This is the
slot number for the configuration entry.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.1
This is the total number of entries looged for this
slot.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.2.1.2
Maximum number of entries to store before wrapping
the log on this slot.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.3
This is the number of entries allocated to log alarms
on this slot. It will always be less than or equal
to the requested number of entries.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.4
This is the log id of the last entry logged for this
slot.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.5
logCommandmandatory
Allows the user to send the log the commands
specified in the enumeration.
Enumerationr/w
Enumerated Values:
1clearLog
.1.3.6.1.4.1.52.4.1.44.2.1.6
wrapmandatory
This is whether or not this configuration has
wrapped or not.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.2.1.7

trapLogTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.3 · 1 row entry · 10 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk trapLogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTTRAPLOG-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTTRAPLOG-MIB::trapLogTable'
trapLogEntry row .1.3.6.1.4.1.52.4.1.44.3.1
Each alarm entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply.
Indexes
Column Syntax OID
logIdmandatory
Each slot has a maximium number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number
of entries for a slot is reached, the log wraps. Each
new en…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.1
nvmpIdmandatory
This contains the nvmp id of the trap that occurred.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.2
This field is set to 2 if a trap as been acknowledged
from the EM.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.3
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap.
OctetString
Constraints:
range: 0-1500
.1.3.6.1.4.1.52.4.1.44.3.1.4
This is an internally defined string used to describe
an alarm. Its primary use is for display on the EMs
LCD. A default value will be used for the old trap
calls.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.52.4.1.44.3.1.5
timeLoggedmandatory
The time the entry was logged. This will be date and
time if possible.
RFC1155-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.3.1.6
filterIdmandatory
This will be used to filter certain alarms. The
criteria is TBD. An example of classification:
informational - requires no intervention. warning -
Does not require immediate intervention. e.g. static
risk severe - Requi…
Enumeration
Enumerated Values:
1informational
2warning
3severe
4fatal
5existing
.1.3.6.1.4.1.52.4.1.44.3.1.7
slotChassismandatory
Slot of this trap log.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.3.1.8
trapOIDmandatory
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.44.3.1.9
z80Timemandatory
This is the time that the Z80 has been up for the
board that sent this trap.
RFC1155-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.3.1.10

filterTable

table mandatory
.1.3.6.1.4.1.52.4.1.44.4 · 1 row entry · 10 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk filterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTTRAPLOG-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTTRAPLOG-MIB::filterTable'
filterEntry row .1.3.6.1.4.1.52.4.1.44.4.1
Each filter entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply.
Column Syntax OID
filterLogIdmandatory
Each slot has a maximum number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number of
entries for a slot is reached, the log wraps. Each new
ent…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.1
filterNvmpIdmandatory
This contains the nvmp id of the trap that was
generated.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.2
This field is non-zero if a trap has been acknowleged
from the EM.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.3
This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap.
OctetString
Constraints:
range: 0-1500
.1.3.6.1.4.1.52.4.1.44.4.1.4
This is an internally defined string used to
describe an alarm. It's primary use is for display
on the EMs LCD. A default value will be used for
the old trap calls.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.52.4.1.44.4.1.5
The time the entry was logged. This will be date
and time if possible.
RFC1155-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.4.1.6
This will be used tofilter certain alarms. The
criteria is TBD. An example of classification:
informational-requires no intervention. warning -
Does not require immediate intervention. e.g.
statis risk severe - Requir…
Enumeration
Enumerated Values:
1informational
2warning
3severe
4fatal
5existing
.1.3.6.1.4.1.52.4.1.44.4.1.7
Slot of this filter entry.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.44.4.1.8
filterTrapOIDmandatory
This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.44.4.1.9
filterZ80Timemandatory
The number of time ticks that have passed since
this boards Z80 processor has been up.
RFC1155-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.44.4.1.10