CTRON-CSMACD-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
7
.1.3.6.1.4.1.52.4.1.2.4.1.1.1
·
1 row entry
·
3 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk ctFnbCSMACDTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-CSMACD-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-CSMACD-MIB::ctFnbCSMACDTable'
A list of entries that provide connection status of CSMA/CD subsystems, for the FNB.
An entry in the ctFnbCSMACDTable containing objects
that provide FNB connection status for a CSMA/CD
subsystem.
that provide FNB connection status for a CSMA/CD
subsystem.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ctFnbCSMACDIndexmandatory
An unique value for each CSMACD subsystem. Its
value ranges between 1 and chassisSlots. The value for each interface must remain constant, at least, from one re-initialization of the entity's network management system… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.1 |
||||||||||||||||
|
ctFnbConnectmandatory
Denotes the connection status of the CSMA/CD board
to the inter-RIC bus. The values of 1, 2, and 4 define connection status of connect for the subsystem, values 5 and 6 define connection status of subnet connect for th… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.2 |
||||||||||||||||
|
ctFnbPortChangesmandatory
Denotes the number of times any port on the
given MIM has changed it's connection to the inter-RIC bus. |
RFC1155-SMICounter Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.52.4.1.2.4.1.1.1.1.3 |
.1.3.6.1.4.1.52.4.1.2.4.1.2.1
·
1 row entry
·
4 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk ctFnbPortConnectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-CSMACD-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-CSMACD-MIB::ctFnbPortConnectTable'
This table is used to control port association on ethernet devices. Only those boards that support port switching will be listed in this table.
Describes a specific port connection entry.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
ctFnbPortConnectBoardIndexmandatory
An instance of a board for which this port
assignment relationship exists. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.4.1.2.1.1.1 |
||||||
|
ctFnbPortConnectPortIndexmandatory
An instance of a port for which this
assignment relationship exists. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.4.1.2.1.1.2 |
||||||
|
ctFnbPortConnectPortAssignmentmandatory
The specific channel that the port is
assigned. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.2.4.1.2.1.1.3 |
||||||
|
ctFnbPortCompIDmandatory
This is the component ID as defined in the chassis
MIB that this port is associated with. These components will be repeater components. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.2.4.1.2.1.1.4 |