The primary controller in the subsytem has failed.
Details:
The primary Controller has failed.
User Action:
Replace controller. Possible causes are controller physically
removed, actual hardware failure.
cpqCrController1InformationTrap
.1.3.6.1.4.1.232.141.3.2.0.2
The primary controller in the subsytem has recovered.
Details:
The primary controller has recovered.
User Action:
None.
cpqCrController2FailureTrap
.1.3.6.1.4.1.232.141.3.2.0.3
The secondary controller in the subsytem has failed.
Details:
The secondary controller has failed.
User Action:
Replace controller. Possible causes are controller
physically removed, actual hardware failure.
cpqCrController2InformationTrap
.1.3.6.1.4.1.232.141.3.2.0.4
The secondary controller in the subsytem has recovered.
Details:
The secondary controller has recovered.
User Action:
None.
cpqCrLogDriveInformationTrap
.1.3.6.1.4.1.232.141.3.3.0.5
A RAIDset has become optimal.
Details:
A RAIDset has become optimal due to a successful completion
of the reconstruction process.
User Action:
None.
cpqCrLogDriveFailureTrap
.1.3.6.1.4.1.232.141.3.3.0.6
A RAIDset has failed.
Details:
The RAIDset has failed and is off-line.
User Action:
Possible cause is too many failed disk drives that make up
the RAIDset, the OS can no longer communicate with the RAIDset
for other reasons.
cpqCrLogDriveReconstructTrap
.1.3.6.1.4.1.232.141.3.3.0.7
A RAIDset has started the reconstruction process.
Details:
The RAIDset has started the reconstruction process but is available
for normal use.
Possible causes are an available disk drive was created as
a spare to be inserted into the set, an existing spare was
automatically added to the set for reconstruction upon failure
of a member disk device.
User Action:
None.
cpqCrLogDriveReducedTrap
.1.3.6.1.4.1.232.141.3.3.0.8
A RAIDset has become degraded.
Details:
A RAIDset has become degraded due to a member disk device
failure.
User Action:
Replace the failed disk device; add a spare to the system
to cause a reconstruct.
cpqCrLogDriveInitializingTrap
.1.3.6.1.4.1.232.141.3.3.0.9
A RAIDset is initializing.
Details:
A RAIDset is in the process of being intialized.
User Action:
None.
cpqCrDiskInformationTrap
.1.3.6.1.4.1.232.141.3.5.0.10
A disk drive has recovered.
Details:
A disk device has recovered.
User Action:
None.
cpqCrDiskFailureTrap
.1.3.6.1.4.1.232.141.3.5.0.11
A disk drive has failed.
Details:
A disk device has failed.
User Action:
Replace the disk device.
cpqCrDiskReconstructTrap
.1.3.6.1.4.1.232.141.3.5.0.12
A disk drive has started the reconstruction process.
Details:
A disk member of a logical drive has begun the reconstruction
process and will be available for use when reconstruction is
complete.
User Action:
Wait for the reconstruction to complete.
cpqCrDiskAvailableTrap
.1.3.6.1.4.1.232.141.3.5.0.13
A disk drive has been made available for use.
Details:
A disk drive has been physically added or set to the
Available state. It can be used as a RAIDset member or as a Spare.
User Action:
None.
cpqCrDiskSpareTrap
.1.3.6.1.4.1.232.141.3.5.0.14
A disk drive has been made a Spare.
Details:
A disk drive has been set to Spare status from Available and
may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
a member device fail in one of those RAIDsets.
User Action:
None.
cpqCrPhyDiskInformationTrap
.1.3.6.1.4.1.232.141.3.5.0.30
A disk drive has recovered.
Details:
A disk device has recovered.
User Action:
None.
cpqCrPhyDiskFailureTrap
.1.3.6.1.4.1.232.141.3.5.0.31
A disk drive has failed.
Details:
A disk device has failed.
User Action:
Replace the disk device.
cpqCrPhyDiskReconstructTrap
.1.3.6.1.4.1.232.141.3.5.0.32
A disk drive has started the reconstruction process.
Details:
A disk member of a logical drive has begun the reconstruction
process and will be available for use when reconstruction is
complete.
User Action:
Wait for the reconstruction to complete.
cpqCrPhyDiskAvailableTrap
.1.3.6.1.4.1.232.141.3.5.0.33
A disk drive has been made available for use.
Details:
A disk drive has been physically added or set to the
Available state. It can be used as a RAIDset member or as a Spare.
User Action:
None.
cpqCrPhyDiskSpareTrap
.1.3.6.1.4.1.232.141.3.5.0.34
A disk drive has been made a Spare.
Details:
A disk drive has been set to Spare status from Available and
may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
a member device fail in one of those RAIDsets.
User Action:
None.
cpqCrEMUNormalTrap
.1.3.6.1.4.1.232.141.3.7.0.15
Primary enclosure state is normal.
Details:
The overall condition of the primary enclosure has returned
to normal.
User Action:
None.
cpqCrEMUFanFailureTrap
.1.3.6.1.4.1.232.141.3.7.0.16
Fan has failed.
Details:
One of the cooling fans in the primary enclosure has
failed.
User Action:
Replace the cooling fan. Possible causes are fan
physically removed, actual hardware failure.
cpqCrEMUFanInformationTrap
.1.3.6.1.4.1.232.141.3.7.0.17
The fan has recovered.
Details:
The cooling fan in the primary enclosure has recovered.
User Action:
None.
cpqCrEMUPowerSupplyFailureTrap
.1.3.6.1.4.1.232.141.3.7.0.18
Power supply has failed.
Details:
One of the power supplies in the primary enclosure has
failed.
User Action:
Replace the power supply. Possible causes are power
supply physically removed, power cord unplugged, actual
hardware failure.
cpqCrEMUPowerSupplyInformationTrap
.1.3.6.1.4.1.232.141.3.7.0.19
The power supply has recovered.
Details:
The power supply in the primary enclosure has recovered.
User Action:
None.
cpqCrEMUTemperatureWarningTrap
.1.3.6.1.4.1.232.141.3.7.0.23
Primary enclosure temperature warning.
Details:
The temperature in the primary enclosure has triggered a
warning condition detected by the controller.
User Action:
Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureCriticalTrap
.1.3.6.1.4.1.232.141.3.7.0.24
Primary enclosure temperature critical!.
Details:
The temperature in the primary enclosure has triggered a
critical condition detected by the controller.
User Action:
Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureInformationTrap
.1.3.6.1.4.1.232.141.3.7.0.25
Primary enclosure temperature normal.
Details:
The temperature in the primary enclosure has
returned to normal.
User Action:
None.
cpqCrExpCabFanFailureTrap
.1.3.6.1.4.1.232.141.3.8.0.20
Fan has failed in expansion cabinet.
Details:
One of the cooling fans in the expansion cabinet has
failed.
User Action:
Replace the cooling fan. Possible causes are fan
physically removed, actual hardware failure.
cpqCrExpCabFanInformationTrap
.1.3.6.1.4.1.232.141.3.8.0.21
Fan has recovered.
Details:
A cooling fan in the expansion cabinet has returned to a
normal state.
User Action:
None.
cpqCrExpCabPowerSupplyFailureTrap
.1.3.6.1.4.1.232.141.3.8.0.22
Power supply has failed.
Details:
One of the power supplies in the expansion cabinet has
failed.
User Action:
Replace the power supply. Possible causes are power
supply physically removed, power cord unplugged, actual
hardware failure.
cpqCrExpCabTemperatureWarningTrap
.1.3.6.1.4.1.232.141.3.8.0.26
Expansion cabinet temperature warning.
Details:
The temperature in the expansion cabinet has triggered a
warning condition detected by the controller.
User Action:
Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureCriticalTrap
.1.3.6.1.4.1.232.141.3.8.0.27
Expansion cabinet temperature critical!
Details:
The temperature in the expansion cabinet has triggered a
critical condition detected by the controller.
User Action:
Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureInformationTrap
.1.3.6.1.4.1.232.141.3.8.0.28
Expansion cabinet temperature normal.
Details:
The temperature in the expansion cabinet has returned to
normal.
User Action:
None.
cpqCrExpCabPowerSupplyInformationTrap
.1.3.6.1.4.1.232.141.3.8.0.29
The power supply has recovered.
Details:
The power supply in the expansion cabinet has recovered.
User Action:
None.