CPQCR-MIB

Imported Objects

compaq, cpqHoTrapFlagsCPQHOST-MIB
OBJECT-TYPERFC-1212
TRAP-TYPERFC-1215
enterprises, Counter, GaugeRFC1155-SMI
DisplayString, sysNameRFC1213-MIB

Objects

cpqClusteredRAID .1.3.6.1.4.1.232.141
cpqCrMibRev .1.3.6.1.4.1.232.141.1
cpqCrMibRevMajor .1.3.6.1.4.1.232.141.1.1
cpqCrMibRevMinor .1.3.6.1.4.1.232.141.1.2
cpqCrMibCondition .1.3.6.1.4.1.232.141.1.3
cpqCrComponent .1.3.6.1.4.1.232.141.2
cpqCrInterface .1.3.6.1.4.1.232.141.2.1
cpqCrOsCommon .1.3.6.1.4.1.232.141.2.1.4
cpqCrOsCommonPollFreq .1.3.6.1.4.1.232.141.2.1.4.1
cpqCrCntlr .1.3.6.1.4.1.232.141.2.2
cpqCrCntlrTable .1.3.6.1.4.1.232.141.2.2.1
cpqCrCntlrEntry .1.3.6.1.4.1.232.141.2.2.1.1
cpqCrCntlrIndex .1.3.6.1.4.1.232.141.2.2.1.1.1
cpqCrCntlrRebuildRate .1.3.6.1.4.1.232.141.2.2.1.1.10
cpqCrCntlrCreateRate .1.3.6.1.4.1.232.141.2.2.1.1.11
cpqCrCntlrCacheSize .1.3.6.1.4.1.232.141.2.2.1.1.12
cpqCrCntlrSimmSizeA .1.3.6.1.4.1.232.141.2.2.1.1.13
cpqCrCntlrSimmSizeB .1.3.6.1.4.1.232.141.2.2.1.1.14
cpqCrCntlrSerialNumber .1.3.6.1.4.1.232.141.2.2.1.1.2
cpqCrCntlrFWRev .1.3.6.1.4.1.232.141.2.2.1.1.3
cpqCrCntlrCondition .1.3.6.1.4.1.232.141.2.2.1.1.4
cpqCrCntlrCurrentRole .1.3.6.1.4.1.232.141.2.2.1.1.8
cpqCrCntlrDriveOwnership .1.3.6.1.4.1.232.141.2.2.1.1.9
cpqCrLogDrv .1.3.6.1.4.1.232.141.2.3
cpqCrLogDrvTable .1.3.6.1.4.1.232.141.2.3.1
cpqCrLogDrvEntry .1.3.6.1.4.1.232.141.2.3.1.1
cpqCrLogDrvCntlrIndex .1.3.6.1.4.1.232.141.2.3.1.1.1
cpqCrLogDrvCondition .1.3.6.1.4.1.232.141.2.3.1.1.10
cpqCrLogDrvPartitionIDs .1.3.6.1.4.1.232.141.2.3.1.1.11
cpqCrLogDrvIndex .1.3.6.1.4.1.232.141.2.3.1.1.2
cpqCrLogDrvRAIDLevel .1.3.6.1.4.1.232.141.2.3.1.1.3
cpqCrLogDrvStatus .1.3.6.1.4.1.232.141.2.3.1.1.4
cpqCrLogDrvRebuildPercentage .1.3.6.1.4.1.232.141.2.3.1.1.5
cpqCrLogDrvAvailSpares .1.3.6.1.4.1.232.141.2.3.1.1.7
cpqCrLogDrvSize .1.3.6.1.4.1.232.141.2.3.1.1.8
cpqCrLogDrvPhyDrvIDs .1.3.6.1.4.1.232.141.2.3.1.1.9
cpqCrSpareDrv .1.3.6.1.4.1.232.141.2.4
cpqCrSpareTable .1.3.6.1.4.1.232.141.2.4.1
cpqCrSpareEntry .1.3.6.1.4.1.232.141.2.4.1.1
cpqCrSpareCntlrIndex .1.3.6.1.4.1.232.141.2.4.1.1.1
cpqCrSparePhyDrvIndex .1.3.6.1.4.1.232.141.2.4.1.1.2
cpqCrSpareStatus .1.3.6.1.4.1.232.141.2.4.1.1.3
cpqCrSpareCondition .1.3.6.1.4.1.232.141.2.4.1.1.4
cpqCrSpareScsiID .1.3.6.1.4.1.232.141.2.4.1.1.5
cpqCrPhyDrv .1.3.6.1.4.1.232.141.2.5
cpqCrPhyDrvTable .1.3.6.1.4.1.232.141.2.5.1
cpqCrPhyDrvEntry .1.3.6.1.4.1.232.141.2.5.1.1
cpqCrPhyDrvCntlrIndex .1.3.6.1.4.1.232.141.2.5.1.1.1
cpqCrPhyDrvIndex .1.3.6.1.4.1.232.141.2.5.1.1.2
cpqCrPhyDrvVendor .1.3.6.1.4.1.232.141.2.5.1.1.3
cpqCrPhyDrvModel .1.3.6.1.4.1.232.141.2.5.1.1.4
cpqCrPhyDrvRevision .1.3.6.1.4.1.232.141.2.5.1.1.5
cpqCrPhyDrvStatus .1.3.6.1.4.1.232.141.2.5.1.1.6
cpqCrPhyDrvSize .1.3.6.1.4.1.232.141.2.5.1.1.7
cpqCrPhyDrvCondition .1.3.6.1.4.1.232.141.2.5.1.1.8
cpqCrPhyDrvScsiID .1.3.6.1.4.1.232.141.2.5.1.1.9
cpqCrEMU .1.3.6.1.4.1.232.141.2.7
cpqCrEMUBoardTemperatureStatus .1.3.6.1.4.1.232.141.2.7.1
cpqCrEMUTemperatureStatus .1.3.6.1.4.1.232.141.2.7.10
cpqCrEMUTemperatureLevel .1.3.6.1.4.1.232.141.2.7.11
cpqCrEMUTemperatureCondition .1.3.6.1.4.1.232.141.2.7.12
cpqCrEMUEnclosureTemperatureStatus .1.3.6.1.4.1.232.141.2.7.2
cpqCrEMUBoardTemperatureLevel .1.3.6.1.4.1.232.141.2.7.3
cpqCrEMUEnclosureTemperatureLevel .1.3.6.1.4.1.232.141.2.7.4
cpqCrEMUCondition .1.3.6.1.4.1.232.141.2.7.5
cpqCrEMUFanStatus .1.3.6.1.4.1.232.141.2.7.6
cpqCrEMUFanCondition .1.3.6.1.4.1.232.141.2.7.7
cpqCrEMUPowerSupplyStatus .1.3.6.1.4.1.232.141.2.7.8
cpqCrEMUPowerSupplyCondition .1.3.6.1.4.1.232.141.2.7.9
cpqCrExpCab .1.3.6.1.4.1.232.141.2.8
cpqCrExpCabPowerSupplyStatus .1.3.6.1.4.1.232.141.2.8.1
cpqCrExpCabTemperatureCondition .1.3.6.1.4.1.232.141.2.8.10
cpqCrExpCabFanStatus .1.3.6.1.4.1.232.141.2.8.2
cpqCrExpCabTemperatureStatus .1.3.6.1.4.1.232.141.2.8.3
cpqCrExpCabCondition .1.3.6.1.4.1.232.141.2.8.6
cpqCrExpCabPowerSupplyCondition .1.3.6.1.4.1.232.141.2.8.7
cpqCrExpCabFanCondition .1.3.6.1.4.1.232.141.2.8.9
cpqCrPartition .1.3.6.1.4.1.232.141.2.9
cpqCrPartitionTable .1.3.6.1.4.1.232.141.2.9.1
cpqCrPartitionEntry .1.3.6.1.4.1.232.141.2.9.1.1
cpqCrPartitionLogDrvIndex .1.3.6.1.4.1.232.141.2.9.1.1.1
cpqCrPartitionIndex .1.3.6.1.4.1.232.141.2.9.1.1.2
cpqCrPartitionRAIDLevel .1.3.6.1.4.1.232.141.2.9.1.1.3
cpqCrPartitionStatus .1.3.6.1.4.1.232.141.2.9.1.1.4
cpqCrPartitionSize .1.3.6.1.4.1.232.141.2.9.1.1.5
cpqCrPartitionCondition .1.3.6.1.4.1.232.141.2.9.1.1.6
cpqCrTrap .1.3.6.1.4.1.232.141.3
cpqCrInterfaceTrap .1.3.6.1.4.1.232.141.3.1
cpqCrCntlrTrap .1.3.6.1.4.1.232.141.3.2
cpqCrLogDrvTrap .1.3.6.1.4.1.232.141.3.3
cpqCrSpareDrvTrap .1.3.6.1.4.1.232.141.3.4
cpqCrPhyDrvTrap .1.3.6.1.4.1.232.141.3.5
cpqCrEMUTrap .1.3.6.1.4.1.232.141.3.7
cpqCrExpCabTrap .1.3.6.1.4.1.232.141.3.8

Notifications/Traps

NameOIDDescription
cpqCrController1FailureTrap

.1.3.6.1.4.1.232.141.3.2.0.1
y controller in the subsytem has failed.
          
Details:
  The primary Controller has failed.
          
User Action:
  Replace controller.  Possible causes are controller physically
  removed, actual hardware failure.
cpqCrController1InformationTrap

.1.3.6.1.4.1.232.141.3.2.0.2
y controller in the subsytem has recovered.
          
Details:
  The primary controller has recovered.
          
User Action:
  None.
cpqCrController2FailureTrap

.1.3.6.1.4.1.232.141.3.2.0.3
ary controller in the subsytem has failed.
          
Details:
  The secondary controller has failed.
          
User Action:
  Replace controller.  Possible causes are controller
  physically removed, actual hardware failure.
cpqCrController2InformationTrap

.1.3.6.1.4.1.232.141.3.2.0.4
ary controller in the subsytem has recovered.
          
Details:
  The secondary controller has recovered.
          
User Action:
  None.
cpqCrLogDriveInformationTrap


.1.3.6.1.4.1.232.141.3.3.0.5
has become optimal.
          
Details:
  A RAIDset has become optimal due to a successful completion
  of the reconstruction process.
          
User Action:
  None.
cpqCrLogDriveFailureTrap


.1.3.6.1.4.1.232.141.3.3.0.6
has failed.
          
Details:
  The RAIDset has failed and is off-line.
          
User Action:
  Possible cause is too many failed disk drives that make up
  the RAIDset, the OS can no longer communicate with the RAIDset
  for other reasons.
cpqCrLogDriveReconstructTrap


.1.3.6.1.4.1.232.141.3.3.0.7
has started the reconstruction process.
          
Details:
  The RAIDset has started the reconstruction process but is available
  for normal use.
  Possible causes are an available disk drive was created as
  a spare to be inserted into the set, an existing spare was
  automatically added to the set for reconstruction upon failure
  of a member disk device.
          
User Action:
  None.
cpqCrLogDriveReducedTrap


.1.3.6.1.4.1.232.141.3.3.0.8
has become degraded.
          
Details:
  A RAIDset has become degraded due to a member disk device
  failure.
          
User Action:
  Replace the failed disk device; add a spare to the system
  to cause a reconstruct.
cpqCrLogDriveInitializingTrap


.1.3.6.1.4.1.232.141.3.3.0.9
is initializing.
          
Details:
  A RAIDset is in the process of being intialized.
          
User Action:
  None.
cpqCrDiskInformationTrap



.1.3.6.1.4.1.232.141.3.5.0.10
ve has recovered.
          
Details:
  A disk device has recovered.
          
User Action:
  None.
cpqCrDiskFailureTrap



.1.3.6.1.4.1.232.141.3.5.0.11
ve has failed.
          
Details:
  A disk device has failed.
          
User Action:
  Replace the disk device.
cpqCrDiskReconstructTrap


.1.3.6.1.4.1.232.141.3.5.0.12
ve has started the reconstruction process.
          
Details:
  A disk member of a logical drive has begun the reconstruction
  process and will be available for use when reconstruction is
  complete.
          
User Action:
  Wait for the reconstruction to complete.
cpqCrDiskAvailableTrap


.1.3.6.1.4.1.232.141.3.5.0.13
ve has been made available for use.
          
Details:
  A disk drive has been physically added or set to the
  Available state. It can be used as a RAIDset member or as a Spare.
          
User Action:
  None.
cpqCrDiskSpareTrap


.1.3.6.1.4.1.232.141.3.5.0.14
ve has been made a Spare.
          
Details:
  A disk drive has been set to Spare status from Available and
  may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
  a member device fail in one of those RAIDsets.
          
User Action:
  None.
cpqCrPhyDiskInformationTrap


.1.3.6.1.4.1.232.141.3.5.0.30
ve has recovered.
          
Details:
  A disk device has recovered.
          
User Action:
  None.
cpqCrPhyDiskFailureTrap


.1.3.6.1.4.1.232.141.3.5.0.31
ve has failed.
          
Details:
  A disk device has failed.
          
User Action:
  Replace the disk device.
cpqCrPhyDiskReconstructTrap


.1.3.6.1.4.1.232.141.3.5.0.32
ve has started the reconstruction process.
          
Details:
  A disk member of a logical drive has begun the reconstruction
  process and will be available for use when reconstruction is
  complete.
          
User Action:
  Wait for the reconstruction to complete.
cpqCrPhyDiskAvailableTrap


.1.3.6.1.4.1.232.141.3.5.0.33
ve has been made available for use.
          
Details:
  A disk drive has been physically added or set to the
  Available state. It can be used as a RAIDset member or as a Spare.
          
User Action:
  None.
cpqCrPhyDiskSpareTrap


.1.3.6.1.4.1.232.141.3.5.0.34
ve has been made a Spare.
          
Details:
  A disk drive has been set to Spare status from Available and
  may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
  a member device fail in one of those RAIDsets.
          
User Action:
  None.
cpqCrEMUNormalTrap

.1.3.6.1.4.1.232.141.3.7.0.15
closure state is normal.
          
Details:
  The overall condition of the primary enclosure has returned
  to normal.
          
          
User Action:
  None.
cpqCrEMUFanFailureTrap

.1.3.6.1.4.1.232.141.3.7.0.16
iled.
          
Details:
  One of the cooling fans in the primary enclosure has
  failed.
          
User Action:
  Replace the cooling fan. Possible causes are fan
  physically removed, actual hardware failure.
cpqCrEMUFanInformationTrap

.1.3.6.1.4.1.232.141.3.7.0.17
s recovered.
          
Details:
  The cooling fan in the primary enclosure has recovered.
          
User Action:
  None.
cpqCrEMUPowerSupplyFailureTrap

.1.3.6.1.4.1.232.141.3.7.0.18
ly has failed.
          
Details:
  One of the power supplies in the primary enclosure has
  failed.
          
User Action:
  Replace the power supply. Possible causes are power
  supply physically removed, power cord unplugged, actual
  hardware failure.
cpqCrEMUPowerSupplyInformationTrap

.1.3.6.1.4.1.232.141.3.7.0.19
supply has recovered.
          
Details:
  The power supply in the primary enclosure has recovered.
          
User Action:
  None.
cpqCrEMUTemperatureWarningTrap

.1.3.6.1.4.1.232.141.3.7.0.23
closure temperature warning.
          
Details:
  The temperature in the primary enclosure has triggered a
  warning condition detected by the controller.
          
User Action:
  Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureCriticalTrap

.1.3.6.1.4.1.232.141.3.7.0.24
closure temperature critical!.
          
Details:
  The temperature in the primary enclosure has triggered a
  critical condition detected by the controller.
          
User Action:
  Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureInformationTrap

.1.3.6.1.4.1.232.141.3.7.0.25
closure temperature normal.
          
Details:
  The temperature in the primary enclosure has
  returned to normal.
          
User Action:
  None.
cpqCrExpCabFanFailureTrap

.1.3.6.1.4.1.232.141.3.8.0.20
iled in expansion cabinet.
          
Details:
  One of the cooling fans in the expansion cabinet has
  failed.
          
User Action:
  Replace the cooling fan. Possible causes are fan
  physically removed, actual hardware failure.
cpqCrExpCabFanInformationTrap

.1.3.6.1.4.1.232.141.3.8.0.21
covered.
          
Details:
  A cooling fan in the expansion cabinet has returned to a
  normal state.
          
User Action:
  None.
cpqCrExpCabPowerSupplyFailureTrap

.1.3.6.1.4.1.232.141.3.8.0.22
ly has failed.
          
Details:
  One of the power supplies in the expansion cabinet has
  failed.
          
User Action:
  Replace the power supply. Possible causes are power
  supply physically removed, power cord unplugged, actual
  hardware failure.
cpqCrExpCabTemperatureWarningTrap

.1.3.6.1.4.1.232.141.3.8.0.26
cabinet temperature warning.
          
Details:
  The temperature in the expansion cabinet has triggered a
  warning condition detected by the controller.
          
User Action:
  Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureCriticalTrap

.1.3.6.1.4.1.232.141.3.8.0.27
cabinet temperature critical!
          
Details:
  The temperature in the expansion cabinet has triggered a
  critical condition detected by the controller.
          
User Action:
  Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureInformationTrap

.1.3.6.1.4.1.232.141.3.8.0.28
cabinet temperature normal.
          
Details:
  The temperature in the expansion cabinet has returned to
  normal.
          
User Action:
  None.
cpqCrExpCabPowerSupplyInformationTrap

.1.3.6.1.4.1.232.141.3.8.0.29
supply has recovered.
          
Details:
  The power supply in the expansion cabinet has recovered.
          
User Action:
  None.