CPQCR-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
41
.1.3.6.1.4.1.232.141.2.2.1
·
1 row entry
·
11 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk cpqCrCntlrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQCR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQCR-MIB::cpqCrCntlrTable'
Clustered RAID Array Controller Table.
Clustered RAID Array Controller Entry.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
cpqCrCntlrIndexmandatory
Clustered RAID Array Controller Index.
This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number associated with it. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.2.1.1.1 |
||||||||
|
cpqCrCntlrSerialNumbermandatory
CR3500 Controller Serial Number.
|
OctetString Constraints: range: 0-9 |
.1.3.6.1.4.1.232.141.2.2.1.1.2 |
||||||||
|
cpqCrCntlrFWRevmandatory
Clustered RAID Array Controller Firmware Revision.
The firmware revision of the Clustered RAID Controller. This value can be used to help identify a particular revision of the controller. |
OctetString Constraints: range: 0-9 |
.1.3.6.1.4.1.232.141.2.2.1.1.3 |
||||||||
|
cpqCrCntlrConditionmandatory
The condition of the device. This value represents the overall
condition of this controller, and any associated logical drives, physical drives, and array accelerators. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.2.1.1.4 |
||||||||
|
cpqCrCntlrCurrentRolemandatory
Clustered RAID Array Controller Current Role.
For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) Indicates that the instrumen… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.2.1.1.8 |
||||||||
|
cpqCrCntlrDriveOwnershipmandatory
Clustered RAID Array Controller Drive Ownership.
For duplexed controllers, indicates to which controller slot the shared devices are associated. The following values are valid: … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.2.1.1.9 |
||||||||
|
cpqCrCntlrRebuildRatemandatory
Clustered RAID Array Controller Rebuild Rate.
Determines the rate at which disks are to be rebuilt if there is I/O activity. 1 = Minimum rate 100 = Maximum rate |
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.232.141.2.2.1.1.10 |
||||||||
|
cpqCrCntlrCreateRatemandatory
Clustered RAID Array Controller Create Rate.
Determines the rate at which RAIDsets are to be created if there is I/O activity. 1 = Minimum rate 100 = maximum rate |
Integer32 Constraints: range: 1-100 |
.1.3.6.1.4.1.232.141.2.2.1.1.11 |
||||||||
|
cpqCrCntlrCacheSizemandatory
Clustered RAID Array Controller Cache Size.
Size of the controller's cache in MB. |
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.232.141.2.2.1.1.12 |
||||||||
|
cpqCrCntlrSimmSizeAmandatory
Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot A in MB. |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.232.141.2.2.1.1.13 |
||||||||
|
cpqCrCntlrSimmSizeBmandatory
Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot B in MB. |
Integer32 Constraints: range: 0-128 |
.1.3.6.1.4.1.232.141.2.2.1.1.14 |
.1.3.6.1.4.1.232.141.2.3.1
·
1 row entry
·
10 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk cpqCrLogDrvTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQCR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQCR-MIB::cpqCrLogDrvTable'
Clustered RAID RAIDset Table.
A table of RAIDset entries.
Clustered RAID RAIDset Entry.
A RAIDset entry.
A RAIDset entry.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cpqCrLogDrvCntlrIndexmandatory
Clustered RAID RAIDset Controller Index.
This maps the RAIDsets into their respective controllers. Controller index 'i' under the controller group owns the associated drives in the RAIDset which use that … |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.3.1.1.1 |
||||||||||||||
|
cpqCrLogDrvIndexmandatory
Clustered RAID RAIDset Index.
This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index star… |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.3.1.1.2 |
||||||||||||||
|
cpqCrLogDrvRAIDLevelmandatory
RAID Level.
This shows the RAID level of the RAIDset. To change the RAID level, run the CL1850 Array Configuration Utility. The following values are valid for the RAIDset RAID Level: … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.3.1.1.3 |
||||||||||||||
|
cpqCrLogDrvStatusmandatory
RAIDset Status.
The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is ope… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.3.1.1.4 |
||||||||||||||
|
cpqCrLogDrvRebuildPercentagemandatory
RAIDset Rebuild Percentage Complete.
After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far the rebuild process has progressed as a perce… |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.232.141.2.3.1.1.5 |
||||||||||||||
|
cpqCrLogDrvAvailSparesmandatory
RAIDset Available Spares.
This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an … |
OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.3.1.1.7 |
||||||||||||||
|
cpqCrLogDrvSizemandatory
RAIDset Size.
This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte w… |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.232.141.2.3.1.1.8 |
||||||||||||||
|
cpqCrLogDrvPhyDrvIDsmandatory
RAIDset Physical Drive IDs.
This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the physical drive table. Each byte of the st… |
OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.3.1.1.9 |
||||||||||||||
|
cpqCrLogDrvConditionmandatory
RAIDset condition.
This value represents the overall condition of this RAIDset and any associated physical drives. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.3.1.1.10 |
||||||||||||||
|
cpqCrLogDrvPartitionIDsmandatory
RAIDset Logical Drive IDs.
This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the logical drive table. Each byte of the strin… |
OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.3.1.1.11 |
.1.3.6.1.4.1.232.141.2.4.1
·
1 row entry
·
5 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk cpqCrSpareTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQCR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQCR-MIB::cpqCrSpareTable'
Clustered RAID Spare Table.
A table of spare entries.
Clustered RAID Spare Entry.
An entry in the spare table.
An entry in the spare table.
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cpqCrSpareCntlrIndexmandatory
Spare Controller Index.
This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.4.1.1.1 |
||||||||||||||||||||
|
cpqCrSparePhyDrvIndexmandatory
Physical Drive Index.
This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.4.1.1.2 |
||||||||||||||||||||
|
cpqCrSpareStatusmandatory
Spare Status.
This shows the status of the on-line spare drive. The following values are valid for the spare status: Hot Spare(5) The drive attached to this channel… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.4.1.1.3 |
||||||||||||||||||||
|
cpqCrSpareConditionmandatory
Spare Drive condition.
This value represents the overall condition of this spare drive and any associated physical drives. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.4.1.1.4 |
||||||||||||||||||||
|
cpqCrSpareScsiIDmandatory
SCSI ID.
This value represents the SCSI identifier of this spare drive. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.4.1.1.5 |
.1.3.6.1.4.1.232.141.2.5.1
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk cpqCrPhyDrvTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQCR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQCR-MIB::cpqCrPhyDrvTable'
Clustered RAID Physical Drive Table.
A table of physical drive entries.
Clustered RAID Physical Drive Entry.
A physical drive entry.
A physical drive entry.
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cpqCrPhyDrvCntlrIndexmandatory
Clustered RAID Physical Drive Controller Index.
This index maps the physical drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller … |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.5.1.1.1 |
||||||||||||||||||||
|
cpqCrPhyDrvIndexmandatory
Clustered RAID Physical Drive Index.
This index is used for selecting the physical drive table entry. This number, along with the cpqCrPhyDrvCntlrIndex uniquely identify a specific physical drive. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.5.1.1.2 |
||||||||||||||||||||
|
cpqCrPhyDrvVendormandatory
Physical Drive Vendor.
This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry command but may have been modified due to space … |
OctetString Constraints: range: 0-8 |
.1.3.6.1.4.1.232.141.2.5.1.1.3 |
||||||||||||||||||||
|
cpqCrPhyDrvModelmandatory
Physical Drive Model.
This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: CP320… |
OctetString Constraints: range: 0-16 |
.1.3.6.1.4.1.232.141.2.5.1.1.4 |
||||||||||||||||||||
|
cpqCrPhyDrvRevisionmandatory
Physical Drive Revision.
This shows the physical drive revision number. |
OctetString Constraints: range: 0-4 |
.1.3.6.1.4.1.232.141.2.5.1.1.5 |
||||||||||||||||||||
|
cpqCrPhyDrvStatusmandatory
Physical Drive Status.
This shows the status of the physical drive. The following values are valid for the physical drive status: Offline (3) The drive attached to this c… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.5.1.1.6 |
||||||||||||||||||||
|
cpqCrPhyDrvSizemandatory
Physical Drive Size in MB.
This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.232.141.2.5.1.1.7 |
||||||||||||||||||||
|
cpqCrPhyDrvConditionmandatory
Physical Drive condition.
This value represents the overall condition of this physical drive. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.5.1.1.8 |
||||||||||||||||||||
|
cpqCrPhyDrvScsiIDmandatory
SCSI ID.
This value represents the SCSI identifier of this physical drive. |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.5.1.1.9 |
.1.3.6.1.4.1.232.141.2.9.1
·
1 row entry
·
6 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk cpqCrPartitionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQCR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQCR-MIB::cpqCrPartitionTable'
Clustered RAID Logical Drive Table.
A table of logical drive entries.
Clustered RAID Logical Drive Entry.
A Logical Drive entry.
A Logical Drive entry.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
cpqCrPartitionLogDrvIndexmandatory
Clustered RAID Logical Drive Index.
This maps the logical drives into their respective RAIDsets. RAIDset index 'i' under the RAIDset group owns the associated drives in the logical drives which use that i… |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.9.1.1.1 |
||||||||||||||
|
cpqCrPartitionIndexmandatory
Clustered RAID Logical Drive Index.
This logical drive number keeps track of multiple instances of logical drives which are part of the same RAIDset. For each RAIDset index value, the logical drive index… |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.232.141.2.9.1.1.2 |
||||||||||||||
|
cpqCrPartitionRAIDLevelmandatory
Logical Drive RAID Level.
This shows the RAID level of the logical drive. To change the RAID level, run the CR3500 Array Configuration Utility. The following values are valid for the logica… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.9.1.1.3 |
||||||||||||||
|
cpqCrPartitionStatusmandatory
Logical Drive Status.
The logical drive can be in one of the following states: Good (2) Indicates that the logical drive is fully operational. Reduced (3) Indicates that … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.9.1.1.4 |
||||||||||||||
|
cpqCrPartitionSizemandatory
Logical Drive Size.
This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as … |
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.232.141.2.9.1.1.5 |
||||||||||||||
|
cpqCrPartitionConditionmandatory
Logical drive condition.
This value represents the overall condition of this logical drive and any associated physical drives. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.232.141.2.9.1.1.6 |