CISCO-UNIFIED-COMPUTING-POWER-MIB

        MIB representation of the Cisco Unified Computing System
POWER management information model package
    
cucsPowerObjects 1.3.6.1.4.1.9.9.719.1.39
Imported Objects
CISCO-SMI ciscoMgmt
CISCO-TC CiscoAlarmSeverity CiscoInetAddressMask CiscoNetworkAddress TimeIntervalSec Unsigned64
CISCO-UNIFIED-COMPUTING-MIB ciscoUnifiedComputingMIBObjects CucsManagedObjectDn CucsManagedObjectId
CISCO-UNIFIED-COMPUTING-TC-MIB CucsNetworkSwitchId CucsPolicyPolicyOwner CucsPowerBudgetFanSpeed CucsPowerCapAction CucsPowerChThrAction CucsPowerGroupState CucsPowerGroupStatsHistThresholded CucsPowerGroupStatsThresholded CucsPowerLockState CucsPowerMemberState CucsPowerMgmtStyle CucsPowerOperState CucsPowerPolicyFanSpeed CucsPowerPowerAvailState CucsPowerPowerDeployState CucsPowerPrioritySharing CucsPowerProfilingMethod CucsPowerPsuLineMode CucsPowerPsuState CucsPowerReallocation CucsPowerReqConflict
INET-ADDRESS-MIB InetAddressIPv4 InetAddressIPv6
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-SMI Counter32 Counter64 Gauge32 MODULE-IDENTITY OBJECT-TYPE TimeTicks Unsigned32
SNMPv2-TC DateAndTime DisplayString MacAddress RowPointer TEXTUAL-CONVENTION TimeInterval TimeStamp TruthValue
Objects (208)
cucsPowerObjects .1.3.6.1.4.1.9.9.719.1.39
cucsPowerBudgetTable .1.3.6.1.4.1.9.9.719.1.39.1
cucsPowerBudgetEntry cucsPowerBudgetInstanceId .1.3.6.1.4.1.9.9.719.1.39.1.1
cucsPowerBudgetInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.1.1.1
cucsPowerBudgetMinPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.10
cucsPowerBudgetOperCommitted SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.11
cucsPowerBudgetOperMin SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.12
cucsPowerBudgetOperPeak SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.13
cucsPowerBudgetScaledWt SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.14
cucsPowerBudgetOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerOperState .1.3.6.1.4.1.9.9.719.1.39.1.1.15
cucsPowerBudgetDynRealloc CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerReallocation .1.3.6.1.4.1.9.9.719.1.39.1.1.16
cucsPowerBudgetPrio SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.17
cucsPowerBudgetCatalogPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.18
cucsPowerBudgetUpdateTime SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.719.1.39.1.1.19
cucsPowerBudgetDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.1.1.2
cucsPowerBudgetCapAction CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerCapAction .1.3.6.1.4.1.9.9.719.1.39.1.1.20
cucsPowerBudgetWeight SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.21
cucsPowerBudgetPsuCapacity SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.22
cucsPowerBudgetPsuState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPsuState .1.3.6.1.4.1.9.9.719.1.39.1.1.23
cucsPowerBudgetStyle CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMgmtStyle .1.3.6.1.4.1.9.9.719.1.39.1.1.24
cucsPowerBudgetAdminFPLockState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerLockState .1.3.6.1.4.1.9.9.719.1.39.1.1.25
cucsPowerBudgetAdminPeakNew SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.26
cucsPowerBudgetBootPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.27
cucsPowerBudgetChRsrvdPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.28
cucsPowerBudgetOperFPLockState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerLockState .1.3.6.1.4.1.9.9.719.1.39.1.1.29
cucsPowerBudgetRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.1.1.3
cucsPowerBudgetOperProfMethod CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerProfilingMethod .1.3.6.1.4.1.9.9.719.1.39.1.1.30
cucsPowerBudgetProfMethod CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerProfilingMethod .1.3.6.1.4.1.9.9.719.1.39.1.1.31
cucsPowerBudgetProfiling SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.1.1.32
cucsPowerBudgetPsuLineMode CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPsuLineMode .1.3.6.1.4.1.9.9.719.1.39.1.1.33
cucsPowerBudgetPowerAvailState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPowerAvailState .1.3.6.1.4.1.9.9.719.1.39.1.1.34
cucsPowerBudgetPowerDeployState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPowerDeployState .1.3.6.1.4.1.9.9.719.1.39.1.1.35
cucsPowerBudgetPowerOnDeploy SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.1.1.36
cucsPowerBudgetFanSpeed CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerBudgetFanSpeed .1.3.6.1.4.1.9.9.719.1.39.1.1.37
cucsPowerBudgetPowerCapSupportEnabled SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.1.1.38
cucsPowerBudgetAdminCommitted SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.4
cucsPowerBudgetAdminPeak SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.5
cucsPowerBudgetCurrentPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.6
cucsPowerBudgetGroupName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.1.1.7
cucsPowerBudgetIdlePower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.8
cucsPowerBudgetMaxPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.1.1.9
cucsPowerPolicyTable .1.3.6.1.4.1.9.9.719.1.39.10
cucsPowerPolicyEntry cucsPowerPolicyInstanceId .1.3.6.1.4.1.9.9.719.1.39.10.1
cucsPowerPolicyInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.10.1.1
cucsPowerPolicyPolicyOwner CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner .1.3.6.1.4.1.9.9.719.1.39.10.1.10
cucsPowerPolicyPropAcl CISCO-TCUnsigned64 .1.3.6.1.4.1.9.9.719.1.39.10.1.11
cucsPowerPolicyFanSpeed CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPolicyFanSpeed .1.3.6.1.4.1.9.9.719.1.39.10.1.12
cucsPowerPolicyDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.10.1.2
cucsPowerPolicyRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.10.1.3
cucsPowerPolicyDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.10.1.4
cucsPowerPolicyIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.10.1.5
cucsPowerPolicyName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.10.1.6
cucsPowerPolicyOperPrio SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.10.1.7
cucsPowerPolicyPrio SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.10.1.8
cucsPowerPolicyPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.10.1.9
cucsPowerPrioWghtTable .1.3.6.1.4.1.9.9.719.1.39.11
cucsPowerPrioWghtEntry cucsPowerPrioWghtInstanceId .1.3.6.1.4.1.9.9.719.1.39.11.1
cucsPowerPrioWghtInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.11.1.1
cucsPowerPrioWghtDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.11.1.2
cucsPowerPrioWghtRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.11.1.3
cucsPowerPrioWghtPrio SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.11.1.4
cucsPowerPrioWghtWeight SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.11.1.5
cucsPowerRackUnitMemberTable .1.3.6.1.4.1.9.9.719.1.39.12
cucsPowerRackUnitMemberEntry cucsPowerRackUnitMemberInstanceId .1.3.6.1.4.1.9.9.719.1.39.12.1
cucsPowerRackUnitMemberInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.12.1.1
cucsPowerRackUnitMemberDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.12.1.2
cucsPowerRackUnitMemberRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.12.1.3
cucsPowerRackUnitMemberId SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.12.1.4
cucsPowerRackUnitMemberOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMemberState .1.3.6.1.4.1.9.9.719.1.39.12.1.5
cucsPowerMgmtPolicyTable .1.3.6.1.4.1.9.9.719.1.39.13
cucsPowerMgmtPolicyEntry cucsPowerMgmtPolicyInstanceId .1.3.6.1.4.1.9.9.719.1.39.13.1
cucsPowerMgmtPolicyInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.13.1.1
cucsPowerMgmtPolicyProfiling SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.13.1.10
cucsPowerMgmtPolicySkipPowerCheck SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.13.1.11
cucsPowerMgmtPolicySkipPowerDeployCheck SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.13.1.12
cucsPowerMgmtPolicyDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.13.1.2
cucsPowerMgmtPolicyRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.13.1.3
cucsPowerMgmtPolicyDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.13.1.4
cucsPowerMgmtPolicyIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.13.1.5
cucsPowerMgmtPolicyName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.13.1.6
cucsPowerMgmtPolicyStyle CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMgmtStyle .1.3.6.1.4.1.9.9.719.1.39.13.1.7
cucsPowerMgmtPolicyPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.13.1.8
cucsPowerMgmtPolicyPolicyOwner CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner .1.3.6.1.4.1.9.9.719.1.39.13.1.9
cucsPowerProfiledPowerTable .1.3.6.1.4.1.9.9.719.1.39.14
cucsPowerProfiledPowerEntry cucsPowerProfiledPowerInstanceId .1.3.6.1.4.1.9.9.719.1.39.14.1
cucsPowerProfiledPowerInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.14.1.1
cucsPowerProfiledPowerPreDiscoveryPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.10
cucsPowerProfiledPowerProfileRunTime SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.11
cucsPowerProfiledPowerProfiledBoot SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.12
cucsPowerProfiledPowerProfiledMax SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.13
cucsPowerProfiledPowerProfiledMin SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.14
cucsPowerProfiledPowerSkipProfiling SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.14.1.15
cucsPowerProfiledPowerDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.14.1.2
cucsPowerProfiledPowerRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.14.1.3
cucsPowerProfiledPowerAbsMinPostPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.4
cucsPowerProfiledPowerMaxAppPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.5
cucsPowerProfiledPowerMaxPostPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.6
cucsPowerProfiledPowerMinAppPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.7
cucsPowerProfiledPowerMinNormPostPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.8
cucsPowerProfiledPowerMinPostPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.14.1.9
cucsPowerFIMemberTable .1.3.6.1.4.1.9.9.719.1.39.15
cucsPowerFIMemberEntry cucsPowerFIMemberInstanceId .1.3.6.1.4.1.9.9.719.1.39.15.1
cucsPowerFIMemberInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.15.1.1
cucsPowerFIMemberDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.15.1.2
cucsPowerFIMemberRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.15.1.3
cucsPowerFIMemberFiId CISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId .1.3.6.1.4.1.9.9.719.1.39.15.1.4
cucsPowerFIMemberId SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.15.1.5
cucsPowerFIMemberOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMemberState .1.3.6.1.4.1.9.9.719.1.39.15.1.6
cucsPowerFexMemberTable .1.3.6.1.4.1.9.9.719.1.39.16
cucsPowerFexMemberEntry cucsPowerFexMemberInstanceId .1.3.6.1.4.1.9.9.719.1.39.16.1
cucsPowerFexMemberInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.16.1.1
cucsPowerFexMemberDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.16.1.2
cucsPowerFexMemberRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.16.1.3
cucsPowerFexMemberId SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.16.1.4
cucsPowerFexMemberOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMemberState .1.3.6.1.4.1.9.9.719.1.39.16.1.5
cucsPowerChassisMemberTable .1.3.6.1.4.1.9.9.719.1.39.2
cucsPowerChassisMemberEntry cucsPowerChassisMemberInstanceId .1.3.6.1.4.1.9.9.719.1.39.2.1
cucsPowerChassisMemberInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.2.1.1
cucsPowerChassisMemberDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.2.1.2
cucsPowerChassisMemberRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.2.1.3
cucsPowerChassisMemberId SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.2.1.4
cucsPowerChassisMemberOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerMemberState .1.3.6.1.4.1.9.9.719.1.39.2.1.5
cucsPowerEpTable .1.3.6.1.4.1.9.9.719.1.39.3
cucsPowerEpEntry cucsPowerEpInstanceId .1.3.6.1.4.1.9.9.719.1.39.3.1
cucsPowerEpInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.3.1.1
cucsPowerEpDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.3.1.2
cucsPowerEpRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.3.1.3
cucsPowerGroupTable .1.3.6.1.4.1.9.9.719.1.39.4
cucsPowerGroupEntry cucsPowerGroupInstanceId .1.3.6.1.4.1.9.9.719.1.39.4.1
cucsPowerGroupInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.4.1.1
cucsPowerGroupCurReqPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.10
cucsPowerGroupMinReqPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.11
cucsPowerGroupIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.4.1.12
cucsPowerGroupName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.4.1.13
cucsPowerGroupQualifier SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.4.1.14
cucsPowerGroupOperCommitted SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.15
cucsPowerGroupOperPeak SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.16
cucsPowerGroupOperState CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerGroupState .1.3.6.1.4.1.9.9.719.1.39.4.1.17
cucsPowerGroupPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.18
cucsPowerGroupPolicyOwner CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner .1.3.6.1.4.1.9.9.719.1.39.4.1.19
cucsPowerGroupDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.4.1.2
cucsPowerGroupMaxReqPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.20
cucsPowerGroupRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.4.1.3
cucsPowerGroupRealloc CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerReallocation .1.3.6.1.4.1.9.9.719.1.39.4.1.4
cucsPowerGroupAdminCommitted SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.5
cucsPowerGroupAdminPeak SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.6
cucsPowerGroupCurrentPower SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.4.1.7
cucsPowerGroupDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.4.1.8
cucsPowerGroupFltAggr CISCO-TCUnsigned64 .1.3.6.1.4.1.9.9.719.1.39.4.1.9
cucsPowerGroupAdditionPolicyTable .1.3.6.1.4.1.9.9.719.1.39.5
cucsPowerGroupAdditionPolicyEntry cucsPowerGroupAdditionPolicyInstanceId .1.3.6.1.4.1.9.9.719.1.39.5.1
cucsPowerGroupAdditionPolicyInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.5.1.1
cucsPowerGroupAdditionPolicyDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.5.1.2
cucsPowerGroupAdditionPolicyRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.5.1.3
cucsPowerGroupAdditionPolicyAction CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerChThrAction .1.3.6.1.4.1.9.9.719.1.39.5.1.4
cucsPowerGroupAdditionPolicyDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.5.1.5
cucsPowerGroupAdditionPolicyIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.5.1.6
cucsPowerGroupAdditionPolicyName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.5.1.7
cucsPowerGroupAdditionPolicyPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.5.1.8
cucsPowerGroupAdditionPolicyPolicyOwner CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner .1.3.6.1.4.1.9.9.719.1.39.5.1.9
cucsPowerGroupQualTable .1.3.6.1.4.1.9.9.719.1.39.6
cucsPowerGroupQualEntry cucsPowerGroupQualInstanceId .1.3.6.1.4.1.9.9.719.1.39.6.1
cucsPowerGroupQualInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.6.1.1
cucsPowerGroupQualDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.6.1.2
cucsPowerGroupQualRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.6.1.3
cucsPowerGroupQualGroupName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.6.1.4
cucsPowerGroupStatsTable .1.3.6.1.4.1.9.9.719.1.39.7
cucsPowerGroupStatsEntry cucsPowerGroupStatsInstanceId .1.3.6.1.4.1.9.9.719.1.39.7.1
cucsPowerGroupStatsInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.7.1.1
cucsPowerGroupStatsThresholded CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerGroupStatsThresholded .1.3.6.1.4.1.9.9.719.1.39.7.1.10
cucsPowerGroupStatsTimeCollected SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.719.1.39.7.1.11
cucsPowerGroupStatsUpdate SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.7.1.12
cucsPowerGroupStatsDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.7.1.2
cucsPowerGroupStatsRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.7.1.3
cucsPowerGroupStatsIntervals SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.7.1.4
cucsPowerGroupStatsPower Integer32 .1.3.6.1.4.1.9.9.719.1.39.7.1.5
cucsPowerGroupStatsPowerAvg Integer32 .1.3.6.1.4.1.9.9.719.1.39.7.1.6
cucsPowerGroupStatsPowerMax Integer32 .1.3.6.1.4.1.9.9.719.1.39.7.1.7
cucsPowerGroupStatsPowerMin Integer32 .1.3.6.1.4.1.9.9.719.1.39.7.1.8
cucsPowerGroupStatsSuspect SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.7.1.9
cucsPowerGroupStatsHistTable .1.3.6.1.4.1.9.9.719.1.39.8
cucsPowerGroupStatsHistEntry cucsPowerGroupStatsHistInstanceId .1.3.6.1.4.1.9.9.719.1.39.8.1
cucsPowerGroupStatsHistInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.8.1.1
cucsPowerGroupStatsHistSuspect SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.8.1.10
cucsPowerGroupStatsHistThresholded CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerGroupStatsHistThresholded .1.3.6.1.4.1.9.9.719.1.39.8.1.11
cucsPowerGroupStatsHistTimeCollected SNMPv2-TCDateAndTime .1.3.6.1.4.1.9.9.719.1.39.8.1.12
cucsPowerGroupStatsHistDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.8.1.2
cucsPowerGroupStatsHistRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.8.1.3
cucsPowerGroupStatsHistId CISCO-TCUnsigned64 .1.3.6.1.4.1.9.9.719.1.39.8.1.4
cucsPowerGroupStatsHistMostRecent SNMPv2-TCTruthValue .1.3.6.1.4.1.9.9.719.1.39.8.1.5
cucsPowerGroupStatsHistPower Integer32 .1.3.6.1.4.1.9.9.719.1.39.8.1.6
cucsPowerGroupStatsHistPowerAvg Integer32 .1.3.6.1.4.1.9.9.719.1.39.8.1.7
cucsPowerGroupStatsHistPowerMax Integer32 .1.3.6.1.4.1.9.9.719.1.39.8.1.8
cucsPowerGroupStatsHistPowerMin Integer32 .1.3.6.1.4.1.9.9.719.1.39.8.1.9
cucsPowerPlacementTable .1.3.6.1.4.1.9.9.719.1.39.9
cucsPowerPlacementEntry cucsPowerPlacementInstanceId .1.3.6.1.4.1.9.9.719.1.39.9.1
cucsPowerPlacementInstanceId CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId .1.3.6.1.4.1.9.9.719.1.39.9.1.1
cucsPowerPlacementSelfReqConflict CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerReqConflict .1.3.6.1.4.1.9.9.719.1.39.9.1.10
cucsPowerPlacementPolicyLevel SNMPv2-SMIGauge32 .1.3.6.1.4.1.9.9.719.1.39.9.1.11
cucsPowerPlacementPolicyOwner CISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner .1.3.6.1.4.1.9.9.719.1.39.9.1.12
cucsPowerPlacementDn CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn .1.3.6.1.4.1.9.9.719.1.39.9.1.2
cucsPowerPlacementRn SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.9.1.3
cucsPowerPlacementDescr SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.9.1.4
cucsPowerPlacementIntId SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.9.1.5
cucsPowerPlacementName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.9.1.6
cucsPowerPlacementPeerReqConflict CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerReqConflict .1.3.6.1.4.1.9.9.719.1.39.9.1.7
cucsPowerPlacementPgName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.9.9.719.1.39.9.1.8
cucsPowerPlacementPrioShare CISCO-UNIFIED-COMPUTING-TC-MIBCucsPowerPrioritySharing .1.3.6.1.4.1.9.9.719.1.39.9.1.9