CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Download MIB Monitored by Observium
MIB representation of the Cisco Unified Computing System
COMPUTE management information model package
Observium actively monitors this MIB Visit Observium
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity Sensors Status
Source file
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Last revised
Identity
cucsComputeObjects
Base OID
1.3.6.1.4.1.9.9.719.1.9
Objects
0 scalars · 1,234 columns
Tables
83 tables
Net-SNMP examples using the cisco MIB directory

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-UNIFIED-COMPUTING-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeObjects'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-UNIFIED-COMPUTING-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeObjects'
Command help
Imported Objects
CISCO-SMI ciscoMgmt
CISCO-TC CiscoAlarmSeverity CiscoInetAddressMask CiscoNetworkAddress TimeIntervalSec Unsigned64
CISCO-UNIFIED-COMPUTING-MIB ciscoUnifiedComputingMIBObjects CucsManagedObjectDn CucsManagedObjectId
CISCO-UNIFIED-COMPUTING-TC-MIB CucsComputeABoardPower CucsComputeAdminLinkAggregation CucsComputeAdminMemoryState CucsComputeAdminPowerState CucsComputeAdminState CucsComputeAdminTrigger CucsComputeAlarmSeverity CucsComputeAssociation CucsComputeAvailability CucsComputeBackplaneSpeed CucsComputeBackplaneSpeedChassisPref CucsComputeBlackListing CucsComputeBladeEpId CucsComputeBladeEpSlotId CucsComputeBladeFsmCurrentFsm CucsComputeBladeFsmStageName CucsComputeBladeFsmTaskFlags CucsComputeBladeFsmTaskItem CucsComputeBladeSlotId CucsComputeCartridgeDiscovery CucsComputeCartridgeSlotId CucsComputeChassisConnPolicyChassisId CucsComputeChassisDiscAction CucsComputeChassisDiscPolicyMulticastHwHash CucsComputeChassisQualMaxId CucsComputeChassisQualMinId CucsComputeCheckPoint CucsComputeConnectivityRebalancing CucsComputeDiscovery CucsComputeEquipmentConstraintType CucsComputeFactoryResetStatus CucsComputeFactoryResetTrigger CucsComputeGraphicsCardPolicyGraphicsCardMode CucsComputeHwChangeDiscPolicyAction CucsComputeInstanceIdQualMaxId CucsComputeInstanceIdQualMinId CucsComputeInventoryStatus CucsComputeIOHubEnvStatsHistThresholded CucsComputeIOHubEnvStatsThresholded CucsComputeIssues CucsComputeKvmMgmtPolicyVmediaEncryption CucsComputeLinkAggregation CucsComputeMbPowerStatsHistThresholded CucsComputeMbPowerStatsThresholded CucsComputeMbTempStatsHistThresholded CucsComputeMbTempStatsThresholded CucsComputeMemoryUnitConstraintType CucsComputeMode CucsComputeOwner CucsComputePciCapOrder CucsComputePCIeFatalCompletionStatsThresholded CucsComputePCIeFatalProtocolStatsThresholded CucsComputePCIeFatalReceiveStatsThresholded CucsComputePCIeFatalStatsThresholded CucsComputePhysicalFsmCurrentFsm CucsComputePhysicalFsmStageName CucsComputePhysicalFsmTaskFlags CucsComputePhysicalFsmTaskItem CucsComputePhysicalLowVoltageMemory CucsComputePooledEnclosureComputeSlotServerInstanceId CucsComputePooledEnclosureComputeSlotSlotId CucsComputePooledRackUnitId CucsComputePooledSlotSlotId CucsComputePortDiscPolicyEthBreakoutAutoDiscovery CucsComputePortDiscPolicyEthSvrAutoDiscovery CucsComputePowerSyncOption CucsComputePowerTransitionSrc CucsComputePsuClusterState CucsComputePsuControlRedundancy CucsComputePsuRedundancy CucsComputePsuRedundancyOperQualifier CucsComputePsuRedundancyOperState CucsComputePwrChangeSource CucsComputeRackQualMaxId CucsComputeRackQualMinId CucsComputeRackUnitFsmCurrentFsm CucsComputeRackUnitFsmStageName CucsComputeRackUnitFsmTaskFlags CucsComputeRackUnitFsmTaskItem CucsComputeRackUnitId CucsComputeRackUnitMbTempStatsHistThresholded CucsComputeRackUnitMbTempStatsThresholded CucsComputeScrubAction CucsComputeServerDiscPolicyFsmCurrentFsm CucsComputeServerDiscPolicyFsmStageName CucsComputeServerDiscPolicyFsmTaskItem CucsComputeServerMgmtDiscAction CucsComputeServerTypeCapType CucsComputeServerUnitChassisId CucsComputeServerUnitFsmCurrentFsm CucsComputeServerUnitFsmStageName CucsComputeServerUnitFsmTaskFlags CucsComputeServerUnitFsmTaskItem CucsComputeServerUnitServerInstanceId CucsComputeServerUnitSlotId CucsComputeSlotQualMaxId CucsComputeSlotQualMinId CucsComputeStorageInitType CucsComputeStorageScrubType CucsConditionRemoteInvRslt CucsEquipmentBoardAggregationRole CucsEquipmentBoardConnectorType CucsEquipmentConnectionStatus CucsEquipmentFanSpeedPolicyFault CucsEquipmentOperability CucsEquipmentPhysicalSecurityState CucsEquipmentPowerState CucsEquipmentPresence CucsEquipmentSensorThresholdStatus CucsEquipmentSlotStatus CucsFsmCompletion CucsFsmFlags CucsFsmFsmStageStatus CucsLsOperState CucsNetworkSwitchId CucsPolicyPolicyOwner CucsPoolPoolAssignmentOrder CucsTrigAckChangeDetails CucsTrigAckChanges CucsTrigAckDisr CucsTrigAckOperState CucsTrigAckPrevOperState CucsTrigAdminState CucsTrigTrigState
INET-ADDRESS-MIB InetAddressIPv4 InetAddressIPv6
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-SMI Counter32 Counter64 Gauge32 MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page) TimeTicks Unsigned32
SNMPv2-TC DateAndTime DisplayString MacAddress RowPointer TEXTUAL-CONVENTION (no object page) TimeInterval TimeStamp TruthValue

Objects

OBS ✓11
.1.3.6.1.4.1.9.9.719.1.9.1 · 12 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.2 · 70 columns
OID Tree

Cisco UCS compute:Blade managed object table

cucsComputeBladeEntry .1.3.6.1.4.1.9.9.719.1.9.2.1
Column Syntax OID
cucsComputeBladeInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.2.1.1
cucsComputeBladeDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.2.1.2
cucsComputeBladeRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.3
cucsComputeBladeAdminPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminPowerState.1.3.6.1.4.1.9.9.719.1.9.2.1.4
cucsComputeBladeAdminStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminState.1.3.6.1.4.1.9.9.719.1.9.2.1.5
cucsComputeBladeAssignedToDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.6
cucsComputeBladeAssociationCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAssociation.1.3.6.1.4.1.9.9.719.1.9.2.1.7
cucsComputeBladeAvailabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAvailability.1.3.6.1.4.1.9.9.719.1.9.2.1.8
cucsComputeBladeAvailableMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.9
cucsComputeBladeChassisIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.10
cucsComputeBladeCheckPointCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCheckPoint.1.3.6.1.4.1.9.9.719.1.9.2.1.11
cucsComputeBladeConnPathCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.2.1.12
cucsComputeBladeConnStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.2.1.13
cucsComputeBladeDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.14
cucsComputeBladeDiscoveryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeDiscovery.1.3.6.1.4.1.9.9.719.1.9.2.1.15
cucsComputeBladeFltAggrCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.2.1.16
cucsComputeBladeFsmDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.17
cucsComputeBladeFsmFlagsSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.18
cucsComputeBladeFsmPrevSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.19
cucsComputeBladeFsmProgrSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.20
cucsComputeBladeFsmRmtInvErrCodeSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.21
cucsComputeBladeFsmRmtInvErrDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.22
cucsComputeBladeFsmRmtInvRsltCISCO-UNIFIED-COMPUTING-TC-MIBCucsConditionRemoteInvRslt.1.3.6.1.4.1.9.9.719.1.9.2.1.23
cucsComputeBladeFsmStageDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.24
cucsComputeBladeFsmStampSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.2.1.25
cucsComputeBladeFsmStatusSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.26
cucsComputeBladeFsmTrySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.27
cucsComputeBladeIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.28
cucsComputeBladeLcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminTrigger.1.3.6.1.4.1.9.9.719.1.9.2.1.29
cucsComputeBladeLcTsSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.2.1.30
cucsComputeBladeManagingInstCISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId.1.3.6.1.4.1.9.9.719.1.9.2.1.31
cucsComputeBladeModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.32
cucsComputeBladeNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.33
cucsComputeBladeNumOfAdaptorsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.34
cucsComputeBladeNumOfCoresSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.35
cucsComputeBladeNumOfCpusSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.36
cucsComputeBladeNumOfEthHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.37
cucsComputeBladeNumOfFcHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.38
cucsComputeBladeNumOfThreadsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.39
cucsComputeBladeOperPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.2.1.40
cucsComputeBladeOperQualifierCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeIssues.1.3.6.1.4.1.9.9.719.1.9.2.1.41
cucsComputeBladeOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsLsOperState.1.3.6.1.4.1.9.9.719.1.9.2.1.42
cucsComputeBladeOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.2.1.43
cucsComputeBladeOriginalUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.44
cucsComputeBladePresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSlotStatus.1.3.6.1.4.1.9.9.719.1.9.2.1.45
cucsComputeBladeRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.46
cucsComputeBladeSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.47
cucsComputeBladeServerIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.48
cucsComputeBladeSlotIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeBladeSlotId.1.3.6.1.4.1.9.9.719.1.9.2.1.49
cucsComputeBladeTotalMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.50
cucsComputeBladeUsrLblSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.51
cucsComputeBladeUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.52
cucsComputeBladeVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.53
cucsComputeBladeNumOfCoresEnabledSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.54
cucsComputeBladeLowVoltageMemoryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePhysicalLowVoltageMemory.1.3.6.1.4.1.9.9.719.1.9.2.1.55
cucsComputeBladeMemorySpeedSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.56
cucsComputeBladeMfgTimeSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.2.1.57
cucsComputeBladePartNumberSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.58
cucsComputeBladeVidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.59
cucsComputeBladePolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.60
cucsComputeBladePolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.2.1.61
cucsComputeBladeLocalIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.62
cucsComputeBladeScaledModeCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeMode.1.3.6.1.4.1.9.9.719.1.9.2.1.63
cucsComputeBladeOperPwrTransSrcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc.1.3.6.1.4.1.9.9.719.1.9.2.1.65
cucsComputeBladeDiscoveryStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.2.1.66
cucsComputeBladeNumOf40GAdaptorsWithOldFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.68
cucsComputeBladeNumOf40GAdaptorsWithUnknownFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.2.1.69
cucsComputeBladeAssetTagSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.70
cucsComputeBladeKmipFaultSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.2.1.71
cucsComputeBladeKmipFaultDescriptionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.2.1.72
.1.3.6.1.4.1.9.9.719.1.9.3 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.4 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.5 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.6 · 22 columns
OID Tree

Cisco UCS compute:Board managed object table

cucsComputeBoardEntry .1.3.6.1.4.1.9.9.719.1.9.6.1
Column Syntax OID
cucsComputeBoardInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.6.1.1
cucsComputeBoardDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.6.1.2
cucsComputeBoardRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.3
cucsComputeBoardCmosVoltageOBS ✓CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.6.1.4
cucsComputeBoardIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.6.1.5
cucsComputeBoardModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.6
cucsComputeBoardOperPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.6.1.7
cucsComputeBoardOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.6.1.8
cucsComputeBoardOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.6.1.9
cucsComputeBoardPerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.6.1.10
cucsComputeBoardPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeABoardPower.1.3.6.1.4.1.9.9.719.1.9.6.1.11
cucsComputeBoardPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.6.1.12
cucsComputeBoardRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.13
cucsComputeBoardSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.14
cucsComputeBoardThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.6.1.15
cucsComputeBoardVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.16
cucsComputeBoardVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.6.1.17
cucsComputeBoardOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.18
cucsComputeBoardPowerUsageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.6.1.19
cucsComputeBoardFaultQualifierSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.20
cucsComputeBoardLocationDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.21
cucsComputeBoardCpuTypeDescriptionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.6.1.23
.1.3.6.1.4.1.9.9.719.1.9.7 · 17 columns
OID Tree

Cisco UCS compute:BoardController managed object table

Column Syntax OID
cucsComputeBoardControllerInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.7.1.1
cucsComputeBoardControllerDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.7.1.2
cucsComputeBoardControllerRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.3
cucsComputeBoardControllerIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.7.1.4
cucsComputeBoardControllerModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.5
cucsComputeBoardControllerOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.7.1.6
cucsComputeBoardControllerOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.7.1.7
cucsComputeBoardControllerPerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.7.1.8
cucsComputeBoardControllerPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.7.1.9
cucsComputeBoardControllerPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.7.1.10
cucsComputeBoardControllerRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.11
cucsComputeBoardControllerSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.12
cucsComputeBoardControllerThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.7.1.13
cucsComputeBoardControllerVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.14
cucsComputeBoardControllerVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.7.1.15
cucsComputeBoardControllerOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.16
cucsComputeBoardControllerLocationDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.7.1.17
.1.3.6.1.4.1.9.9.719.1.9.8 · 14 columns
OID Tree

Cisco UCS compute:ChassisDiscPolicy managed object table

Column Syntax OID
cucsComputeChassisDiscPolicyInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.8.1.1
cucsComputeChassisDiscPolicyDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.8.1.2
cucsComputeChassisDiscPolicyRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.8.1.3
cucsComputeChassisDiscPolicyActionCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeChassisDiscAction.1.3.6.1.4.1.9.9.719.1.9.8.1.4
cucsComputeChassisDiscPolicyDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.8.1.5
cucsComputeChassisDiscPolicyIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.8.1.6
cucsComputeChassisDiscPolicyNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.8.1.7
cucsComputeChassisDiscPolicyQualifierSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.8.1.8
cucsComputeChassisDiscPolicyRebalanceCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeConnectivityRebalancing.1.3.6.1.4.1.9.9.719.1.9.8.1.9
cucsComputeChassisDiscPolicyLinkAggregationPrefCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeLinkAggregation.1.3.6.1.4.1.9.9.719.1.9.8.1.10
cucsComputeChassisDiscPolicyPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.8.1.11
cucsComputeChassisDiscPolicyPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.8.1.12
cucsComputeChassisDiscPolicyMulticastHwHashCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeChassisDiscPolicyMulticastHwHash.1.3.6.1.4.1.9.9.719.1.9.8.1.13
cucsComputeChassisDiscPolicyBackplaneSpeedPrefCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeBackplaneSpeed.1.3.6.1.4.1.9.9.719.1.9.8.1.14
.1.3.6.1.4.1.9.9.719.1.9.9 · 5 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.10 · 3 columns
OID Tree

Cisco UCS compute:Defaults managed object table

.1.3.6.1.4.1.9.9.719.1.9.11 · 17 columns
OID Tree

Cisco UCS compute:IOHub managed object table

cucsComputeIOHubEntry .1.3.6.1.4.1.9.9.719.1.9.11.1
Column Syntax OID
cucsComputeIOHubInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.11.1.1
cucsComputeIOHubDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.11.1.2
cucsComputeIOHubRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.3
cucsComputeIOHubIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.11.1.4
cucsComputeIOHubModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.5
cucsComputeIOHubOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.11.1.6
cucsComputeIOHubOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.11.1.7
cucsComputeIOHubPerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.11.1.8
cucsComputeIOHubPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.11.1.9
cucsComputeIOHubPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.11.1.10
cucsComputeIOHubRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.11
cucsComputeIOHubSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.12
cucsComputeIOHubThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.11.1.13
cucsComputeIOHubVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.14
cucsComputeIOHubVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.11.1.15
cucsComputeIOHubOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.16
cucsComputeIOHubLocationDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.11.1.17
.1.3.6.1.4.1.9.9.719.1.9.12 · 12 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.13 · 12 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.14 · 20 columns
OID Tree

Cisco UCS compute:MbPowerStats managed object table

Column Syntax OID
cucsComputeMbPowerStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.14.1.1
cucsComputeMbPowerStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.14.1.2
cucsComputeMbPowerStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.14.1.3
cucsComputeMbPowerStatsConsumedPowerOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.14.1.4
cucsComputeMbPowerStatsConsumedPowerAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.5
cucsComputeMbPowerStatsConsumedPowerMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.6
cucsComputeMbPowerStatsConsumedPowerMinInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.7
cucsComputeMbPowerStatsInputCurrentOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.14.1.8
cucsComputeMbPowerStatsInputCurrentAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.9
cucsComputeMbPowerStatsInputCurrentMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.10
cucsComputeMbPowerStatsInputCurrentMinInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.11
cucsComputeMbPowerStatsInputVoltageOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.14.1.12
cucsComputeMbPowerStatsInputVoltageAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.13
cucsComputeMbPowerStatsInputVoltageMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.14
cucsComputeMbPowerStatsInputVoltageMinInteger32.1.3.6.1.4.1.9.9.719.1.9.14.1.15
cucsComputeMbPowerStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.14.1.16
cucsComputeMbPowerStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.14.1.17
cucsComputeMbPowerStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeMbPowerStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.14.1.18
cucsComputeMbPowerStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.14.1.19
cucsComputeMbPowerStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.14.1.20
.1.3.6.1.4.1.9.9.719.1.9.15 · 20 columns
OID Tree

Cisco UCS compute:MbPowerStatsHist managed object table

Column Syntax OID
cucsComputeMbPowerStatsHistInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.15.1.1
cucsComputeMbPowerStatsHistDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.15.1.2
cucsComputeMbPowerStatsHistRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.15.1.3
cucsComputeMbPowerStatsHistConsumedPowerInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.4
cucsComputeMbPowerStatsHistConsumedPowerAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.5
cucsComputeMbPowerStatsHistConsumedPowerMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.6
cucsComputeMbPowerStatsHistConsumedPowerMinInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.7
cucsComputeMbPowerStatsHistIdCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.15.1.8
cucsComputeMbPowerStatsHistInputCurrentInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.9
cucsComputeMbPowerStatsHistInputCurrentAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.10
cucsComputeMbPowerStatsHistInputCurrentMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.11
cucsComputeMbPowerStatsHistInputCurrentMinInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.12
cucsComputeMbPowerStatsHistInputVoltageInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.13
cucsComputeMbPowerStatsHistInputVoltageAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.14
cucsComputeMbPowerStatsHistInputVoltageMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.15
cucsComputeMbPowerStatsHistInputVoltageMinInteger32.1.3.6.1.4.1.9.9.719.1.9.15.1.16
cucsComputeMbPowerStatsHistMostRecentSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.15.1.17
cucsComputeMbPowerStatsHistSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.15.1.18
cucsComputeMbPowerStatsHistThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeMbPowerStatsHistThresholded.1.3.6.1.4.1.9.9.719.1.9.15.1.19
cucsComputeMbPowerStatsHistTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.15.1.20
.1.3.6.1.4.1.9.9.719.1.9.16 · 24 columns
OID Tree

Cisco UCS compute:MbTempStats managed object table

Column Syntax OID
cucsComputeMbTempStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.16.1.1
cucsComputeMbTempStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.16.1.2
cucsComputeMbTempStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.16.1.3
cucsComputeMbTempStatsFmTempSenIoInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.4
cucsComputeMbTempStatsFmTempSenIoAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.5
cucsComputeMbTempStatsFmTempSenIoMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.6
cucsComputeMbTempStatsFmTempSenIoMinInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.7
cucsComputeMbTempStatsFmTempSenRearInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.8
cucsComputeMbTempStatsFmTempSenRearAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.9
cucsComputeMbTempStatsFmTempSenRearLInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.10
cucsComputeMbTempStatsFmTempSenRearLAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.11
cucsComputeMbTempStatsFmTempSenRearLMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.12
cucsComputeMbTempStatsFmTempSenRearLMinInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.13
cucsComputeMbTempStatsFmTempSenRearMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.14
cucsComputeMbTempStatsFmTempSenRearMinInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.15
cucsComputeMbTempStatsFmTempSenRearRInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.16
cucsComputeMbTempStatsFmTempSenRearRAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.17
cucsComputeMbTempStatsFmTempSenRearRMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.18
cucsComputeMbTempStatsFmTempSenRearRMinInteger32.1.3.6.1.4.1.9.9.719.1.9.16.1.19
cucsComputeMbTempStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.16.1.20
cucsComputeMbTempStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.16.1.21
cucsComputeMbTempStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeMbTempStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.16.1.22
cucsComputeMbTempStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.16.1.23
cucsComputeMbTempStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.16.1.24
.1.3.6.1.4.1.9.9.719.1.9.17 · 24 columns
OID Tree

Cisco UCS compute:MbTempStatsHist managed object table

Column Syntax OID
cucsComputeMbTempStatsHistInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.17.1.1
cucsComputeMbTempStatsHistDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.17.1.2
cucsComputeMbTempStatsHistRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.17.1.3
cucsComputeMbTempStatsHistFmTempSenIoInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.4
cucsComputeMbTempStatsHistFmTempSenIoAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.5
cucsComputeMbTempStatsHistFmTempSenIoMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.6
cucsComputeMbTempStatsHistFmTempSenIoMinInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.7
cucsComputeMbTempStatsHistFmTempSenRearInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.8
cucsComputeMbTempStatsHistFmTempSenRearAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.9
cucsComputeMbTempStatsHistFmTempSenRearLInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.10
cucsComputeMbTempStatsHistFmTempSenRearLAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.11
cucsComputeMbTempStatsHistFmTempSenRearLMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.12
cucsComputeMbTempStatsHistFmTempSenRearLMinInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.13
cucsComputeMbTempStatsHistFmTempSenRearMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.14
cucsComputeMbTempStatsHistFmTempSenRearMinInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.15
cucsComputeMbTempStatsHistFmTempSenRearRInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.16
cucsComputeMbTempStatsHistFmTempSenRearRAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.17
cucsComputeMbTempStatsHistFmTempSenRearRMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.18
cucsComputeMbTempStatsHistFmTempSenRearRMinInteger32.1.3.6.1.4.1.9.9.719.1.9.17.1.19
cucsComputeMbTempStatsHistIdCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.17.1.20
cucsComputeMbTempStatsHistMostRecentSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.17.1.21
cucsComputeMbTempStatsHistSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.17.1.22
cucsComputeMbTempStatsHistThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeMbTempStatsHistThresholded.1.3.6.1.4.1.9.9.719.1.9.17.1.23
cucsComputeMbTempStatsHistTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.17.1.24
.1.3.6.1.4.1.9.9.719.1.9.18 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.19 · 41 columns
OID Tree

Cisco UCS compute:PCIeFatalCompletionStats managed object table

Column Syntax OID
cucsComputePCIeFatalCompletionStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.19.1.1
cucsComputePCIeFatalCompletionStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.19.1.2
cucsComputePCIeFatalCompletionStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.19.1.3
cucsComputePCIeFatalCompletionStatsAbortErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.19.1.4
cucsComputePCIeFatalCompletionStatsAbortErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.5
cucsComputePCIeFatalCompletionStatsAbortErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.6
cucsComputePCIeFatalCompletionStatsAbortErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.7
cucsComputePCIeFatalCompletionStatsAbortErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.8
cucsComputePCIeFatalCompletionStatsAbortErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.9
cucsComputePCIeFatalCompletionStatsAbortErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.10
cucsComputePCIeFatalCompletionStatsAbortErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.11
cucsComputePCIeFatalCompletionStatsAbortErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.12
cucsComputePCIeFatalCompletionStatsTimeoutErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.19.1.13
cucsComputePCIeFatalCompletionStatsTimeoutErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.14
cucsComputePCIeFatalCompletionStatsTimeoutErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.15
cucsComputePCIeFatalCompletionStatsTimeoutErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.16
cucsComputePCIeFatalCompletionStatsTimeoutErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.17
cucsComputePCIeFatalCompletionStatsTimeoutErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.18
cucsComputePCIeFatalCompletionStatsTimeoutErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.19
cucsComputePCIeFatalCompletionStatsTimeoutErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.20
cucsComputePCIeFatalCompletionStatsTimeoutErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.21
cucsComputePCIeFatalCompletionStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.22
cucsComputePCIeFatalCompletionStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.19.1.23
cucsComputePCIeFatalCompletionStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePCIeFatalCompletionStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.19.1.24
cucsComputePCIeFatalCompletionStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.19.1.25
cucsComputePCIeFatalCompletionStatsUnexpectedErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.19.1.26
cucsComputePCIeFatalCompletionStatsUnexpectedErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.27
cucsComputePCIeFatalCompletionStatsUnexpectedErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.28
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.29
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.30
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.31
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.32
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.33
cucsComputePCIeFatalCompletionStatsUnexpectedErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.34
cucsComputePCIeFatalCompletionStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.35
cucsComputePCIeFatalCompletionStatsAbortErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.36
cucsComputePCIeFatalCompletionStatsAbortErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.37
cucsComputePCIeFatalCompletionStatsTimeoutErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.38
cucsComputePCIeFatalCompletionStatsTimeoutErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.39
cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.40
cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.19.1.41
.1.3.6.1.4.1.9.9.719.1.9.20 · 30 columns
OID Tree

Cisco UCS compute:PCIeFatalProtocolStats managed object table

Column Syntax OID
cucsComputePCIeFatalProtocolStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.20.1.1
cucsComputePCIeFatalProtocolStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.20.1.2
cucsComputePCIeFatalProtocolStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.20.1.3
cucsComputePCIeFatalProtocolStatsDllpErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.20.1.4
cucsComputePCIeFatalProtocolStatsDllpErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.5
cucsComputePCIeFatalProtocolStatsDllpErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.6
cucsComputePCIeFatalProtocolStatsDllpErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.7
cucsComputePCIeFatalProtocolStatsDllpErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.8
cucsComputePCIeFatalProtocolStatsDllpErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.9
cucsComputePCIeFatalProtocolStatsDllpErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.10
cucsComputePCIeFatalProtocolStatsDllpErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.11
cucsComputePCIeFatalProtocolStatsDllpErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.12
cucsComputePCIeFatalProtocolStatsFlowControlErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.20.1.13
cucsComputePCIeFatalProtocolStatsFlowControlErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.14
cucsComputePCIeFatalProtocolStatsFlowControlErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.15
cucsComputePCIeFatalProtocolStatsFlowControlErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.16
cucsComputePCIeFatalProtocolStatsFlowControlErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.17
cucsComputePCIeFatalProtocolStatsFlowControlErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.18
cucsComputePCIeFatalProtocolStatsFlowControlErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.19
cucsComputePCIeFatalProtocolStatsFlowControlErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.20
cucsComputePCIeFatalProtocolStatsFlowControlErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.21
cucsComputePCIeFatalProtocolStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.22
cucsComputePCIeFatalProtocolStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.20.1.23
cucsComputePCIeFatalProtocolStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePCIeFatalProtocolStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.20.1.24
cucsComputePCIeFatalProtocolStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.20.1.25
cucsComputePCIeFatalProtocolStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.26
cucsComputePCIeFatalProtocolStatsDllpErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.27
cucsComputePCIeFatalProtocolStatsDllpErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.28
cucsComputePCIeFatalProtocolStatsFlowControlErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.29
cucsComputePCIeFatalProtocolStatsFlowControlErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.20.1.30
.1.3.6.1.4.1.9.9.719.1.9.21 · 52 columns
OID Tree

Cisco UCS compute:PCIeFatalReceiveStats managed object table

Column Syntax OID
cucsComputePCIeFatalReceiveStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.21.1.1
cucsComputePCIeFatalReceiveStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.21.1.2
cucsComputePCIeFatalReceiveStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.21.1.3
cucsComputePCIeFatalReceiveStatsBufferOverflowErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.21.1.4
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.5
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.6
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.7
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.8
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.9
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.10
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.11
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.12
cucsComputePCIeFatalReceiveStatsErrFatalErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.21.1.13
cucsComputePCIeFatalReceiveStatsErrFatalErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.14
cucsComputePCIeFatalReceiveStatsErrFatalErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.15
cucsComputePCIeFatalReceiveStatsErrFatalErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.16
cucsComputePCIeFatalReceiveStatsErrFatalErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.17
cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.18
cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.19
cucsComputePCIeFatalReceiveStatsErrFatalErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.20
cucsComputePCIeFatalReceiveStatsErrFatalErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.21
cucsComputePCIeFatalReceiveStatsErrNonFatalErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.21.1.22
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.23
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.24
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.25
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.26
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.27
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.28
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.29
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.30
cucsComputePCIeFatalReceiveStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.31
cucsComputePCIeFatalReceiveStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.21.1.32
cucsComputePCIeFatalReceiveStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePCIeFatalReceiveStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.21.1.33
cucsComputePCIeFatalReceiveStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.21.1.34
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.21.1.35
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.36
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.37
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.38
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.39
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.40
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.41
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.42
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.43
cucsComputePCIeFatalReceiveStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.44
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.45
cucsComputePCIeFatalReceiveStatsBufferOverflowErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.46
cucsComputePCIeFatalReceiveStatsErrFatalErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.47
cucsComputePCIeFatalReceiveStatsErrFatalErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.48
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.49
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.50
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.51
cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.21.1.52
.1.3.6.1.4.1.9.9.719.1.9.22 · 52 columns
OID Tree

Cisco UCS compute:PCIeFatalStats managed object table

Column Syntax OID
cucsComputePCIeFatalStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.22.1.1
cucsComputePCIeFatalStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.22.1.2
cucsComputePCIeFatalStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.22.1.3
cucsComputePCIeFatalStatsAcsViolationErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.22.1.4
cucsComputePCIeFatalStatsAcsViolationErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.5
cucsComputePCIeFatalStatsAcsViolationErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.6
cucsComputePCIeFatalStatsAcsViolationErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.7
cucsComputePCIeFatalStatsAcsViolationErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.8
cucsComputePCIeFatalStatsAcsViolationErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.9
cucsComputePCIeFatalStatsAcsViolationErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.10
cucsComputePCIeFatalStatsAcsViolationErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.11
cucsComputePCIeFatalStatsAcsViolationErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.12
cucsComputePCIeFatalStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.13
cucsComputePCIeFatalStatsMalformedTLPErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.22.1.14
cucsComputePCIeFatalStatsMalformedTLPErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.15
cucsComputePCIeFatalStatsMalformedTLPErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.16
cucsComputePCIeFatalStatsMalformedTLPErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.17
cucsComputePCIeFatalStatsMalformedTLPErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.18
cucsComputePCIeFatalStatsMalformedTLPErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.19
cucsComputePCIeFatalStatsMalformedTLPErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.20
cucsComputePCIeFatalStatsMalformedTLPErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.21
cucsComputePCIeFatalStatsMalformedTLPErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.22
cucsComputePCIeFatalStatsPoisonedTLPErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.22.1.23
cucsComputePCIeFatalStatsPoisonedTLPErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.24
cucsComputePCIeFatalStatsPoisonedTLPErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.25
cucsComputePCIeFatalStatsPoisonedTLPErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.26
cucsComputePCIeFatalStatsPoisonedTLPErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.27
cucsComputePCIeFatalStatsPoisonedTLPErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.28
cucsComputePCIeFatalStatsPoisonedTLPErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.29
cucsComputePCIeFatalStatsPoisonedTLPErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.30
cucsComputePCIeFatalStatsPoisonedTLPErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.31
cucsComputePCIeFatalStatsSurpriseLinkDownErrorsSNMPv2-SMICounter32.1.3.6.1.4.1.9.9.719.1.9.22.1.32
cucsComputePCIeFatalStatsSurpriseLinkDownErrors15MinSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.33
cucsComputePCIeFatalStatsSurpriseLinkDownErrors15MinHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.34
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1DaySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.35
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1DayHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.36
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1HourSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.37
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1HourHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.38
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1WeekSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.39
cucsComputePCIeFatalStatsSurpriseLinkDownErrors1WeekHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.40
cucsComputePCIeFatalStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.22.1.41
cucsComputePCIeFatalStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePCIeFatalStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.22.1.42
cucsComputePCIeFatalStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.22.1.43
cucsComputePCIeFatalStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.44
cucsComputePCIeFatalStatsAcsViolationErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.45
cucsComputePCIeFatalStatsAcsViolationErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.46
cucsComputePCIeFatalStatsMalformedTLPErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.47
cucsComputePCIeFatalStatsMalformedTLPErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.48
cucsComputePCIeFatalStatsPoisonedTLPErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.49
cucsComputePCIeFatalStatsPoisonedTLPErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.50
cucsComputePCIeFatalStatsSurpriseLinkDownErrors2WeeksSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.51
cucsComputePCIeFatalStatsSurpriseLinkDownErrors2WeeksHSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.22.1.52
.1.3.6.1.4.1.9.9.719.1.9.23 · 7 columns
OID Tree

Cisco UCS compute:PciCap managed object table

.1.3.6.1.4.1.9.9.719.1.9.24 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.25 · 5 columns
OID Tree

Cisco UCS compute:PhysicalQual managed object table

.1.3.6.1.4.1.9.9.719.1.9.26 · 8 columns
OID Tree

Cisco UCS compute:Platform managed object table

.1.3.6.1.4.1.9.9.719.1.9.27 · 11 columns
OID Tree

Cisco UCS compute:Pool managed object table

.1.3.6.1.4.1.9.9.719.1.9.28 · 5 columns
OID Tree

Cisco UCS compute:Poolable managed object table

.1.3.6.1.4.1.9.9.719.1.9.29 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.30 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.31 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.32 · 14 columns
OID Tree

Cisco UCS compute:PsuControl managed object table

cucsComputePsuControlEntry .1.3.6.1.4.1.9.9.719.1.9.32.1
Column Syntax OID
cucsComputePsuControlInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.32.1.1
cucsComputePsuControlDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.32.1.2
cucsComputePsuControlRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.32.1.3
cucsComputePsuControlClusterStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePsuClusterState.1.3.6.1.4.1.9.9.719.1.9.32.1.4
cucsComputePsuControlDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.32.1.5
cucsComputePsuControlInputPowerStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.32.1.6
cucsComputePsuControlIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.32.1.7
cucsComputePsuControlNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.32.1.8
cucsComputePsuControlOperQualifierCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePsuRedundancyOperQualifier.1.3.6.1.4.1.9.9.719.1.9.32.1.9
cucsComputePsuControlOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePsuRedundancyOperState.1.3.6.1.4.1.9.9.719.1.9.32.1.10
cucsComputePsuControlOutputPowerStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.32.1.11
cucsComputePsuControlRedundancyCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePsuControlRedundancy.1.3.6.1.4.1.9.9.719.1.9.32.1.12
cucsComputePsuControlPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.32.1.13
cucsComputePsuControlPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.32.1.14
.1.3.6.1.4.1.9.9.719.1.9.33 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.34 · 8 columns
OID Tree

Cisco UCS compute:Qual managed object table

.1.3.6.1.4.1.9.9.719.1.9.35 · 72 columns
OID Tree

Cisco UCS compute:RackUnit managed object table

cucsComputeRackUnitEntry .1.3.6.1.4.1.9.9.719.1.9.35.1
Column Syntax OID
cucsComputeRackUnitInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.35.1.1
cucsComputeRackUnitDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.35.1.2
cucsComputeRackUnitRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.3
cucsComputeRackUnitAdminPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminPowerState.1.3.6.1.4.1.9.9.719.1.9.35.1.4
cucsComputeRackUnitAdminStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminState.1.3.6.1.4.1.9.9.719.1.9.35.1.5
cucsComputeRackUnitAssignedToDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.6
cucsComputeRackUnitAssociationCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAssociation.1.3.6.1.4.1.9.9.719.1.9.35.1.7
cucsComputeRackUnitAvailabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAvailability.1.3.6.1.4.1.9.9.719.1.9.35.1.8
cucsComputeRackUnitAvailableMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.9
cucsComputeRackUnitCheckPointCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCheckPoint.1.3.6.1.4.1.9.9.719.1.9.35.1.10
cucsComputeRackUnitConnPathCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.35.1.11
cucsComputeRackUnitConnStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.35.1.12
cucsComputeRackUnitDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.13
cucsComputeRackUnitDiscoveryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeDiscovery.1.3.6.1.4.1.9.9.719.1.9.35.1.14
cucsComputeRackUnitFltAggrCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.35.1.15
cucsComputeRackUnitFsmDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.16
cucsComputeRackUnitFsmFlagsSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.17
cucsComputeRackUnitFsmPrevSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.18
cucsComputeRackUnitFsmProgrSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.19
cucsComputeRackUnitFsmRmtInvErrCodeSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.20
cucsComputeRackUnitFsmRmtInvErrDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.21
cucsComputeRackUnitFsmRmtInvRsltCISCO-UNIFIED-COMPUTING-TC-MIBCucsConditionRemoteInvRslt.1.3.6.1.4.1.9.9.719.1.9.35.1.22
cucsComputeRackUnitFsmStageDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.23
cucsComputeRackUnitFsmStampSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.35.1.24
cucsComputeRackUnitFsmStatusSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.25
cucsComputeRackUnitFsmTrySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.26
cucsComputeRackUnitIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeRackUnitId.1.3.6.1.4.1.9.9.719.1.9.35.1.27
cucsComputeRackUnitIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.28
cucsComputeRackUnitLcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminTrigger.1.3.6.1.4.1.9.9.719.1.9.35.1.29
cucsComputeRackUnitLcTsSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.35.1.30
cucsComputeRackUnitManagingInstCISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId.1.3.6.1.4.1.9.9.719.1.9.35.1.31
cucsComputeRackUnitModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.32
cucsComputeRackUnitNameOBS ✓SNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.33
cucsComputeRackUnitNumOfAdaptorsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.34
cucsComputeRackUnitNumOfCoresSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.35
cucsComputeRackUnitNumOfCpusSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.36
cucsComputeRackUnitNumOfEthHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.37
cucsComputeRackUnitNumOfFcHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.38
cucsComputeRackUnitNumOfThreadsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.39
cucsComputeRackUnitOperPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.35.1.40
cucsComputeRackUnitOperQualifierCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeIssues.1.3.6.1.4.1.9.9.719.1.9.35.1.41
cucsComputeRackUnitOperStateOBS ✓CISCO-UNIFIED-COMPUTING-TC-MIBCucsLsOperState.1.3.6.1.4.1.9.9.719.1.9.35.1.42
cucsComputeRackUnitOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.35.1.43
cucsComputeRackUnitOriginalUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.44
cucsComputeRackUnitPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSlotStatus.1.3.6.1.4.1.9.9.719.1.9.35.1.45
cucsComputeRackUnitRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.46
cucsComputeRackUnitSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.47
cucsComputeRackUnitServerIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.48
cucsComputeRackUnitTotalMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.49
cucsComputeRackUnitUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.50
cucsComputeRackUnitVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.51
cucsComputeRackUnitVersionHolderSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.35.1.52
cucsComputeRackUnitNumOfCoresEnabledSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.53
cucsComputeRackUnitLowVoltageMemoryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePhysicalLowVoltageMemory.1.3.6.1.4.1.9.9.719.1.9.35.1.54
cucsComputeRackUnitMemorySpeedSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.55
cucsComputeRackUnitUsrLblSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.56
cucsComputeRackUnitMfgTimeSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.35.1.57
cucsComputeRackUnitPartNumberSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.58
cucsComputeRackUnitVidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.59
cucsComputeRackUnitPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.60
cucsComputeRackUnitPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.35.1.61
cucsComputeRackUnitLocalIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.62
cucsComputeRackUnitOperPwrTransSrcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc.1.3.6.1.4.1.9.9.719.1.9.35.1.63
cucsComputeRackUnitDiscoveryStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.35.1.64
cucsComputeRackUnitNumOf40GAdaptorsWithOldFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.66
cucsComputeRackUnitNumOf40GAdaptorsWithUnknownFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.35.1.67
cucsComputeRackUnitFanSpeedConfigStatusSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.68
cucsComputeRackUnitFanSpeedPolicyFaultCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentFanSpeedPolicyFault.1.3.6.1.4.1.9.9.719.1.9.35.1.69
cucsComputeRackUnitAssetTagSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.70
cucsComputeRackUnitKmipFaultSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.35.1.71
cucsComputeRackUnitKmipFaultDescriptionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.35.1.72
cucsComputeRackUnitPhysicalSecurityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPhysicalSecurityState.1.3.6.1.4.1.9.9.719.1.9.35.1.73
.1.3.6.1.4.1.9.9.719.1.9.36 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.37 · 17 columns
OID Tree

Cisco UCS compute:RtcBattery managed object table

cucsComputeRtcBatteryEntry .1.3.6.1.4.1.9.9.719.1.9.37.1
Column Syntax OID
cucsComputeRtcBatteryInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.37.1.1
cucsComputeRtcBatteryDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.37.1.2
cucsComputeRtcBatteryRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.3
cucsComputeRtcBatteryIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.37.1.4
cucsComputeRtcBatteryModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.5
cucsComputeRtcBatteryOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.37.1.6
cucsComputeRtcBatteryOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.37.1.7
cucsComputeRtcBatteryPerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.37.1.8
cucsComputeRtcBatteryPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.37.1.9
cucsComputeRtcBatteryPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.37.1.10
cucsComputeRtcBatteryRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.11
cucsComputeRtcBatterySerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.12
cucsComputeRtcBatteryThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.37.1.13
cucsComputeRtcBatteryVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.14
cucsComputeRtcBatteryVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.37.1.15
cucsComputeRtcBatteryOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.16
cucsComputeRtcBatteryLocationDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.37.1.17
.1.3.6.1.4.1.9.9.719.1.9.38 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.39 · 21 columns
OID Tree

Cisco UCS compute:ServerDiscPolicy managed object table

Column Syntax OID
cucsComputeServerDiscPolicyInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.39.1.1
cucsComputeServerDiscPolicyDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.39.1.2
cucsComputeServerDiscPolicyRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.3
cucsComputeServerDiscPolicyActionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.4
cucsComputeServerDiscPolicyDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.5
cucsComputeServerDiscPolicyIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.6
cucsComputeServerDiscPolicyNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.7
cucsComputeServerDiscPolicyQualifierSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.8
cucsComputeServerDiscPolicyScrubPolicyNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.9
cucsComputeServerDiscPolicyFsmDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.10
cucsComputeServerDiscPolicyFsmPrevSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.11
cucsComputeServerDiscPolicyFsmProgrSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.39.1.12
cucsComputeServerDiscPolicyFsmRmtInvErrCodeSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.39.1.13
cucsComputeServerDiscPolicyFsmRmtInvErrDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.14
cucsComputeServerDiscPolicyFsmRmtInvRsltCISCO-UNIFIED-COMPUTING-TC-MIBCucsConditionRemoteInvRslt.1.3.6.1.4.1.9.9.719.1.9.39.1.15
cucsComputeServerDiscPolicyFsmStageDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.16
cucsComputeServerDiscPolicyFsmStampSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.39.1.17
cucsComputeServerDiscPolicyFsmStatusSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.39.1.18
cucsComputeServerDiscPolicyFsmTrySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.39.1.19
cucsComputeServerDiscPolicyPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.39.1.20
cucsComputeServerDiscPolicyPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.39.1.21
.1.3.6.1.4.1.9.9.719.1.9.40 · 5 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.41 · 4 columns
OID Tree

Cisco UCS compute:PhysicalAssocCtx managed object table

.1.3.6.1.4.1.9.9.719.1.9.42 · 5 columns
OID Tree

Cisco UCS compute:PoolPolicyRef managed object table

.1.3.6.1.4.1.9.9.719.1.9.43 · 5 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.44 · 28 columns
OID Tree

Cisco UCS compute:RackUnitMbTempStats managed object table

Column Syntax OID
cucsComputeRackUnitMbTempStatsInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.44.1.1
cucsComputeRackUnitMbTempStatsDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.44.1.2
cucsComputeRackUnitMbTempStatsRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.44.1.3
cucsComputeRackUnitMbTempStatsAmbientTempOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.44.1.4
cucsComputeRackUnitMbTempStatsAmbientTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.5
cucsComputeRackUnitMbTempStatsAmbientTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.6
cucsComputeRackUnitMbTempStatsAmbientTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.7
cucsComputeRackUnitMbTempStatsFrontTempOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.44.1.8
cucsComputeRackUnitMbTempStatsFrontTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.9
cucsComputeRackUnitMbTempStatsFrontTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.10
cucsComputeRackUnitMbTempStatsFrontTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.11
cucsComputeRackUnitMbTempStatsIntervalsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.44.1.12
cucsComputeRackUnitMbTempStatsIoh1TempOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.44.1.13
cucsComputeRackUnitMbTempStatsIoh1TempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.14
cucsComputeRackUnitMbTempStatsIoh1TempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.15
cucsComputeRackUnitMbTempStatsIoh1TempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.16
cucsComputeRackUnitMbTempStatsIoh2TempOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.44.1.17
cucsComputeRackUnitMbTempStatsIoh2TempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.18
cucsComputeRackUnitMbTempStatsIoh2TempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.19
cucsComputeRackUnitMbTempStatsIoh2TempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.20
cucsComputeRackUnitMbTempStatsRearTempOBS ✓Integer32.1.3.6.1.4.1.9.9.719.1.9.44.1.21
cucsComputeRackUnitMbTempStatsRearTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.22
cucsComputeRackUnitMbTempStatsRearTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.23
cucsComputeRackUnitMbTempStatsRearTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.44.1.24
cucsComputeRackUnitMbTempStatsSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.44.1.25
cucsComputeRackUnitMbTempStatsThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeRackUnitMbTempStatsThresholded.1.3.6.1.4.1.9.9.719.1.9.44.1.26
cucsComputeRackUnitMbTempStatsTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.44.1.27
cucsComputeRackUnitMbTempStatsUpdateSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.44.1.28
.1.3.6.1.4.1.9.9.719.1.9.45 · 28 columns
OID Tree

Cisco UCS compute:RackUnitMbTempStatsHist managed object table

Column Syntax OID
cucsComputeRackUnitMbTempStatsHistInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.45.1.1
cucsComputeRackUnitMbTempStatsHistDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.45.1.2
cucsComputeRackUnitMbTempStatsHistRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.45.1.3
cucsComputeRackUnitMbTempStatsHistAmbientTempInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.4
cucsComputeRackUnitMbTempStatsHistAmbientTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.5
cucsComputeRackUnitMbTempStatsHistAmbientTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.6
cucsComputeRackUnitMbTempStatsHistAmbientTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.7
cucsComputeRackUnitMbTempStatsHistFrontTempInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.8
cucsComputeRackUnitMbTempStatsHistFrontTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.9
cucsComputeRackUnitMbTempStatsHistFrontTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.10
cucsComputeRackUnitMbTempStatsHistFrontTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.11
cucsComputeRackUnitMbTempStatsHistIdCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.45.1.12
cucsComputeRackUnitMbTempStatsHistIoh1TempInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.13
cucsComputeRackUnitMbTempStatsHistIoh1TempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.14
cucsComputeRackUnitMbTempStatsHistIoh1TempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.15
cucsComputeRackUnitMbTempStatsHistIoh1TempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.16
cucsComputeRackUnitMbTempStatsHistIoh2TempInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.17
cucsComputeRackUnitMbTempStatsHistIoh2TempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.18
cucsComputeRackUnitMbTempStatsHistIoh2TempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.19
cucsComputeRackUnitMbTempStatsHistIoh2TempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.20
cucsComputeRackUnitMbTempStatsHistMostRecentSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.45.1.21
cucsComputeRackUnitMbTempStatsHistRearTempInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.22
cucsComputeRackUnitMbTempStatsHistRearTempAvgInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.23
cucsComputeRackUnitMbTempStatsHistRearTempMaxInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.24
cucsComputeRackUnitMbTempStatsHistRearTempMinInteger32.1.3.6.1.4.1.9.9.719.1.9.45.1.25
cucsComputeRackUnitMbTempStatsHistSuspectSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.45.1.26
cucsComputeRackUnitMbTempStatsHistThresholdedCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeRackUnitMbTempStatsHistThresholded.1.3.6.1.4.1.9.9.719.1.9.45.1.27
cucsComputeRackUnitMbTempStatsHistTimeCollectedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.45.1.28
.1.3.6.1.4.1.9.9.719.1.9.46 · 13 columns
OID Tree

Cisco UCS compute:ChassisConnPolicy managed object table

.1.3.6.1.4.1.9.9.719.1.9.47 · 5 columns
OID Tree

Cisco UCS compute:PnuOSImage managed object table

.1.3.6.1.4.1.9.9.719.1.9.48 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.49 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.50 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.51 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.52 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.53 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.54 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.55 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.56 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.57 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.58 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.59 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.60 · 23 columns
OID Tree

Cisco UCS compute:FwSyncAck managed object table

cucsComputeFwSyncAckEntry .1.3.6.1.4.1.9.9.719.1.9.60.1
Column Syntax OID
cucsComputeFwSyncAckInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.60.1.1
cucsComputeFwSyncAckDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.60.1.2
cucsComputeFwSyncAckRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.3
cucsComputeFwSyncAckAckedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.60.1.4
cucsComputeFwSyncAckAckedBySNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.5
cucsComputeFwSyncAckAdminStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAdminState.1.3.6.1.4.1.9.9.719.1.9.60.1.6
cucsComputeFwSyncAckAutoDeleteSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.60.1.7
cucsComputeFwSyncAckChangeBySNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.8
cucsComputeFwSyncAckChangeDetailsCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAckChangeDetails.1.3.6.1.4.1.9.9.719.1.9.60.1.9
cucsComputeFwSyncAckChangesCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAckChanges.1.3.6.1.4.1.9.9.719.1.9.60.1.10
cucsComputeFwSyncAckDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.11
cucsComputeFwSyncAckDisrCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAckDisr.1.3.6.1.4.1.9.9.719.1.9.60.1.12
cucsComputeFwSyncAckIgnoreCapSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.60.1.13
cucsComputeFwSyncAckIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.14
cucsComputeFwSyncAckModifiedSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.60.1.15
cucsComputeFwSyncAckNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.16
cucsComputeFwSyncAckOperSchedulerSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.17
cucsComputeFwSyncAckOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAckOperState.1.3.6.1.4.1.9.9.719.1.9.60.1.18
cucsComputeFwSyncAckPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.60.1.19
cucsComputeFwSyncAckPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.60.1.20
cucsComputeFwSyncAckPrevOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigAckPrevOperState.1.3.6.1.4.1.9.9.719.1.9.60.1.21
cucsComputeFwSyncAckSchedulerSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.60.1.22
cucsComputeFwSyncAckTriggerConfigStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsTrigTrigState.1.3.6.1.4.1.9.9.719.1.9.60.1.23
.1.3.6.1.4.1.9.9.719.1.9.61 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.62 · 5 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.63 · 6 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.64 · 28 columns
OID Tree

Cisco UCS compute:ExtBoard managed object table

cucsComputeExtBoardEntry .1.3.6.1.4.1.9.9.719.1.9.64.1
Column Syntax OID
cucsComputeExtBoardInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.64.1.1
cucsComputeExtBoardDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.64.1.2
cucsComputeExtBoardRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.3
cucsComputeExtBoardBoardAggregationRoleCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentBoardAggregationRole.1.3.6.1.4.1.9.9.719.1.9.64.1.4
cucsComputeExtBoardChassisIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.64.1.5
cucsComputeExtBoardCmosVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.6
cucsComputeExtBoardConnPathCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.7
cucsComputeExtBoardConnStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.8
cucsComputeExtBoardFaultQualifierSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.9
cucsComputeExtBoardIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.64.1.10
cucsComputeExtBoardLocationDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.11
cucsComputeExtBoardManagingInstCISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId.1.3.6.1.4.1.9.9.719.1.9.64.1.12
cucsComputeExtBoardModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.13
cucsComputeExtBoardOperPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.64.1.14
cucsComputeExtBoardOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.15
cucsComputeExtBoardOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.64.1.16
cucsComputeExtBoardOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.64.1.17
cucsComputeExtBoardPerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.18
cucsComputeExtBoardPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeABoardPower.1.3.6.1.4.1.9.9.719.1.9.64.1.19
cucsComputeExtBoardPowerUsageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.20
cucsComputeExtBoardPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.64.1.21
cucsComputeExtBoardRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.22
cucsComputeExtBoardSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.23
cucsComputeExtBoardSlotIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.64.1.24
cucsComputeExtBoardThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.25
cucsComputeExtBoardVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.64.1.26
cucsComputeExtBoardVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.27
cucsComputeExtBoardDiscoveryStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.64.1.28
.1.3.6.1.4.1.9.9.719.1.9.65 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.66 · 12 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.67 · 12 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.68 · 4 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.71 · 22 columns
OID Tree

Cisco UCS compute:Cartridge managed object table

cucsComputeCartridgeEntry .1.3.6.1.4.1.9.9.719.1.9.71.1
Column Syntax OID
cucsComputeCartridgeInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.71.1.1
cucsComputeCartridgeDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.71.1.2
cucsComputeCartridgeRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.3
cucsComputeCartridgeChassisIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.71.1.4
cucsComputeCartridgeDiscoveryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCartridgeDiscovery.1.3.6.1.4.1.9.9.719.1.9.71.1.5
cucsComputeCartridgeFltAggrCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.71.1.6
cucsComputeCartridgeIdSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.71.1.7
cucsComputeCartridgeLcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminTrigger.1.3.6.1.4.1.9.9.719.1.9.71.1.8
cucsComputeCartridgeLcTsSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.71.1.9
cucsComputeCartridgeModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.10
cucsComputeCartridgeOperQualifierReasonSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.11
cucsComputeCartridgeOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.71.1.12
cucsComputeCartridgeOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.71.1.13
cucsComputeCartridgePerfCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.71.1.14
cucsComputeCartridgePowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.71.1.15
cucsComputeCartridgePresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence.1.3.6.1.4.1.9.9.719.1.9.71.1.16
cucsComputeCartridgeRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.17
cucsComputeCartridgeSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.18
cucsComputeCartridgeSlotIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCartridgeSlotId.1.3.6.1.4.1.9.9.719.1.9.71.1.19
cucsComputeCartridgeThermalCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.71.1.20
cucsComputeCartridgeVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.71.1.21
cucsComputeCartridgeVoltageCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus.1.3.6.1.4.1.9.9.719.1.9.71.1.22
.1.3.6.1.4.1.9.9.719.1.9.72 · 5 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.73 · 11 columns
OID Tree
Cisco UCS compute:PooledEnclosureComputeSlot managed
          object table
.1.3.6.1.4.1.9.9.719.1.9.74 · 70 columns
OID Tree

Cisco UCS compute:ServerUnit managed object table

cucsComputeServerUnitEntry .1.3.6.1.4.1.9.9.719.1.9.74.1
Column Syntax OID
cucsComputeServerUnitInstanceIdCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId.1.3.6.1.4.1.9.9.719.1.9.74.1.1
cucsComputeServerUnitDnCISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn.1.3.6.1.4.1.9.9.719.1.9.74.1.2
cucsComputeServerUnitRnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.3
cucsComputeServerUnitAdminPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminPowerState.1.3.6.1.4.1.9.9.719.1.9.74.1.4
cucsComputeServerUnitAdminStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminState.1.3.6.1.4.1.9.9.719.1.9.74.1.5
cucsComputeServerUnitAssignedToDnSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.6
cucsComputeServerUnitAssociationCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAssociation.1.3.6.1.4.1.9.9.719.1.9.74.1.7
cucsComputeServerUnitAvailabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAvailability.1.3.6.1.4.1.9.9.719.1.9.74.1.8
cucsComputeServerUnitAvailableMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.9
cucsComputeServerUnitChassisIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeServerUnitChassisId.1.3.6.1.4.1.9.9.719.1.9.74.1.10
cucsComputeServerUnitCheckPointCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeCheckPoint.1.3.6.1.4.1.9.9.719.1.9.74.1.11
cucsComputeServerUnitConnPathCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.74.1.12
cucsComputeServerUnitConnStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.74.1.13
cucsComputeServerUnitDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.14
cucsComputeServerUnitDiscoveryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeDiscovery.1.3.6.1.4.1.9.9.719.1.9.74.1.15
cucsComputeServerUnitDiscoveryStatusCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentConnectionStatus.1.3.6.1.4.1.9.9.719.1.9.74.1.16
cucsComputeServerUnitFltAggrCISCO-TCUnsigned64.1.3.6.1.4.1.9.9.719.1.9.74.1.17
cucsComputeServerUnitFsmDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.18
cucsComputeServerUnitFsmFlagsSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.19
cucsComputeServerUnitFsmPrevSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.20
cucsComputeServerUnitFsmProgrSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.21
cucsComputeServerUnitFsmRmtInvErrCodeSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.22
cucsComputeServerUnitFsmRmtInvErrDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.23
cucsComputeServerUnitFsmRmtInvRsltCISCO-UNIFIED-COMPUTING-TC-MIBCucsConditionRemoteInvRslt.1.3.6.1.4.1.9.9.719.1.9.74.1.24
cucsComputeServerUnitFsmStageDescrSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.25
cucsComputeServerUnitFsmStampSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.74.1.26
cucsComputeServerUnitFsmStatusSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.27
cucsComputeServerUnitFsmTrySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.28
cucsComputeServerUnitIntIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.29
cucsComputeServerUnitLcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeAdminTrigger.1.3.6.1.4.1.9.9.719.1.9.74.1.30
cucsComputeServerUnitLcTsSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.74.1.31
cucsComputeServerUnitLocalIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.32
cucsComputeServerUnitLowVoltageMemoryCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePhysicalLowVoltageMemory.1.3.6.1.4.1.9.9.719.1.9.74.1.33
cucsComputeServerUnitManagingInstCISCO-UNIFIED-COMPUTING-TC-MIBCucsNetworkSwitchId.1.3.6.1.4.1.9.9.719.1.9.74.1.34
cucsComputeServerUnitMemorySpeedSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.35
cucsComputeServerUnitMfgTimeSNMPv2-TCDateAndTime.1.3.6.1.4.1.9.9.719.1.9.74.1.36
cucsComputeServerUnitModelSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.37
cucsComputeServerUnitNameSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.38
cucsComputeServerUnitNumOfAdaptorsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.39
cucsComputeServerUnitNumOfCoresSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.40
cucsComputeServerUnitNumOfCoresEnabledSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.41
cucsComputeServerUnitNumOfCpusSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.42
cucsComputeServerUnitNumOfEthHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.43
cucsComputeServerUnitNumOfFcHostIfsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.44
cucsComputeServerUnitNumOfThreadsSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.45
cucsComputeServerUnitOperPowerCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState.1.3.6.1.4.1.9.9.719.1.9.74.1.46
cucsComputeServerUnitOperQualifierCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeIssues.1.3.6.1.4.1.9.9.719.1.9.74.1.47
cucsComputeServerUnitOperStateCISCO-UNIFIED-COMPUTING-TC-MIBCucsLsOperState.1.3.6.1.4.1.9.9.719.1.9.74.1.48
cucsComputeServerUnitOperabilityCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability.1.3.6.1.4.1.9.9.719.1.9.74.1.49
cucsComputeServerUnitOriginalUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.50
cucsComputeServerUnitPartNumberSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.51
cucsComputeServerUnitPolicyLevelSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.52
cucsComputeServerUnitPolicyOwnerCISCO-UNIFIED-COMPUTING-TC-MIBCucsPolicyPolicyOwner.1.3.6.1.4.1.9.9.719.1.9.74.1.53
cucsComputeServerUnitPresenceCISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSlotStatus.1.3.6.1.4.1.9.9.719.1.9.74.1.54
cucsComputeServerUnitRevisionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.55
cucsComputeServerUnitSerialSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.56
cucsComputeServerUnitServerIdSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.57
cucsComputeServerUnitServerInstanceIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeServerUnitServerInstanceId.1.3.6.1.4.1.9.9.719.1.9.74.1.58
cucsComputeServerUnitSlotIdCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputeServerUnitSlotId.1.3.6.1.4.1.9.9.719.1.9.74.1.59
cucsComputeServerUnitTotalMemorySNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.60
cucsComputeServerUnitUsrLblSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.61
cucsComputeServerUnitUuidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.62
cucsComputeServerUnitVendorSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.63
cucsComputeServerUnitVidSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.64
cucsComputeServerUnitNumOf40GAdaptorsWithOldFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.66
cucsComputeServerUnitNumOf40GAdaptorsWithUnknownFwSNMPv2-SMIGauge32.1.3.6.1.4.1.9.9.719.1.9.74.1.67
cucsComputeServerUnitOperPwrTransSrcCISCO-UNIFIED-COMPUTING-TC-MIBCucsComputePowerTransitionSrc.1.3.6.1.4.1.9.9.719.1.9.74.1.68
cucsComputeServerUnitAssetTagSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.69
cucsComputeServerUnitKmipFaultSNMPv2-TCTruthValue.1.3.6.1.4.1.9.9.719.1.9.74.1.70
cucsComputeServerUnitKmipFaultDescriptionSNMP-FRAMEWORK-MIBSnmpAdminString.1.3.6.1.4.1.9.9.719.1.9.74.1.71
.1.3.6.1.4.1.9.9.719.1.9.75 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.76 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.77 · 7 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.117 · 8 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.118 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.119 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.121 · 9 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.122 · 10 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.123 · 4 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.124 · 11 columns
OID Tree
.1.3.6.1.4.1.9.9.719.1.9.125 · 7 columns
OID Tree

Cisco UCS compute:RebootLog managed object table

Dependencies (9) 8 direct · 1 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree