CISCO-FIREPOWER-LSMAINT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
37
.1.3.6.1.4.1.9.9.826.1.48.1 · 1 row entry · 26 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfprLsmaintAckTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-LSMAINT-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-LSMAINT-MIB::cfprLsmaintAckTable'
Cisco Firepower lsmaint:Ack managed object table
cfprLsmaintAckEntry row .1.3.6.1.4.1.9.9.826.1.48.1.1
Entry for the cfprLsmaintAckTable table.
Column Syntax OID
Instance identifier of the managed object.
CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.48.1.1.1
Cisco Firepower lsmaint:Ack:dn managed object property
CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.48.1.1.2
Cisco Firepower lsmaint:Ack:rn managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.3
Cisco Firepower lsmaint:Ack:acked managed object property
SNMPv2-TCDateAndTime
Type Constraints:
range: 8
range: 11
Description:
A date-time specification.

field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month …
.1.3.6.1.4.1.9.9.826.1.48.1.1.4
Cisco Firepower lsmaint:Ack:ackedBy managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.5
Cisco Firepower lsmaint:Ack:adminState managed object property
CISCO-FIREPOWER-TC-MIBCfprTrigAdminState
Type Values:
0triggerImmediate
1trigger
2triggered
3untriggered
4userAck
5userDiscard
.1.3.6.1.4.1.9.9.826.1.48.1.1.6
Cisco Firepower lsmaint:Ack:autoDelete managed object property
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.826.1.48.1.1.7
Cisco Firepower lsmaint:Ack:changeBy managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.8
Cisco Firepower lsmaint:Ack:changeDetails managed
object property
CISCO-FIREPOWER-TC-MIBCfprLsmaintAckChangeDetails
Type Values:
0binding
1hostVirtEthIf
2hostNonvirtEthIf
3hostEthIfProfile
4hostEthIfQos
5hostEthIfNwCtrl
6hostVirtFcIf
7hostNonvirtFcIf
8hostVirtFcIfPersBind
9hostNonvirtFcIfPersBind
10hostFcIfProfile
11hostFcIfQos
12hostFcoeIf
13vif
14vlan
15vsan
16ip
17bootOrder
18bootVirtVnic
19bootNonvirtVnic
20bootLocalStorage
21bootVirtPxe
22bootNonvirtPxe
24bladeIdentity
25agentPolicy
26biosFw
27storageControllerFw
28adaptorHostFw
29adaptorNwFw
30mgmtControllerFw
31localDiskPolicy
32pin
33sol
34epAuth
35biosProfile
36checkpoint
37implicitReboot
38implicitHostFcIfProfileRedeploy
39boardControllerFw
40hostEthIfQosHostControl
41localDiskFw
42implicitHostEthIfProfileRedeploy
43storagePath
44bmcUpdateBiosFw
45hostIfPcie
46flexflashConfig
48bootmodeConfig
49securebootConfig
50vmediaConfig
51ssposUpdateFw
.1.3.6.1.4.1.9.9.826.1.48.1.1.9
Cisco Firepower lsmaint:Ack:changeMode managed object property
CISCO-FIREPOWER-TC-MIBCfprLsmaintChangeMode
Type Values:
0noChange
1unconfig
2forceUnconfig
4rediscover
8config
16diagConfig
32diagUnconfig
64removeConfig
128diag
.1.3.6.1.4.1.9.9.826.1.48.1.1.10
Cisco Firepower lsmaint:Ack:changes managed object property
CISCO-FIREPOWER-TC-MIBCfprLsmaintAckChanges
Type Values:
0serverIdentity
1storage
2networking
3vnicVhbaPlacement
4bootOrder
5serverAssignment
6operationalPolicies
.1.3.6.1.4.1.9.9.826.1.48.1.1.11
Cisco Firepower lsmaint:Ack:configIssues managed object property
CISCO-FIREPOWER-TC-MIBCfprLsConfigIssues
Type Values:
0insufficientResources
1vnicCapacity
2vhbaCapacity
3fcoeCapacity
4switchVirtualIfCapacity
5macAddressAssignment
6wwpnAssignment
7wwnnAssignment
8systemUuidAssignment
9bootOrderSanImagePath
10bootOrderPxe
11computeUndiscovered
12adaptorProtectedEthCapability
13adaptorFcoeCapability
14incompatibleNumberOfLocalDisks
15adaptorRequirement
16memoryRequirement
17processorRequirement
18serverPositionRequirement
19computeUnavailable
20wwnnDerivationFromVhba
21bootConfigurationInvalid
22connectionPlacement
23wwpnDerivationVirtualizedPort
24macDerivationVirtualizedPort
25qosPolicyInvalid
26vlanPortCapacity
27physicalRequirement
28destructiveLocalDiskConfig
29powerGroupRequirement
30migration
31incompatibleBiosImage
32incompatibleDiskTypes
33incompatibleRaidLevel
34invalidWwn
35insufficientPowerBudget
36bootipPolicyInvalid
37hostimgPolicyInvalid
38imgsecPolicyInvalid
39provsrvPolicyInvalid
40incompatBiosForSriovVnics
41iscsiConfig
42vnicNotHaReady
43missingPrimaryVlan
44missingRaidKey
45bootOrderIscsi
46vfcVnicPvlanConflict
47vifResourcesOverprovisioned
48pinningVlanMismatch
49vnicVlanAssignmentError
50iscsiInitiatorIpAddress
51storagePathConfigurationError
52zoneCapacity
53dynamicVfVnic
54boardControllerUpdateUnsupported
55vnicVconProvisioningChange
56namedVlanInaccessible
57pinningInvalid
58nonInterruptFsmRunning
59missingFirmwareImage
60remotePolicy
61resourceOwnershipConflict
62duplicateAddressConflict
.1.3.6.1.4.1.9.9.826.1.48.1.1.12
Cisco Firepower lsmaint:Ack:deploymentMode managed
object property
CISCO-FIREPOWER-TC-MIBCfprTrigAckMode
Type Values:
0immediate
1userAck
2timerAutomatic
.1.3.6.1.4.1.9.9.826.1.48.1.1.13
Cisco Firepower lsmaint:Ack:descr managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.14
Cisco Firepower lsmaint:Ack:disr managed object property
CISCO-FIREPOWER-TC-MIBCfprLsmaintAckDisr
Type Values:
0upTime
1acPowerCycle
.1.3.6.1.4.1.9.9.826.1.48.1.1.15
Cisco Firepower lsmaint:Ack:ignoreCap managed object property
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.826.1.48.1.1.16
Cisco Firepower lsmaint:Ack:intId managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.17
Cisco Firepower lsmaint:Ack:modified managed object property
SNMPv2-TCDateAndTime
Type Constraints:
range: 8
range: 11
Description:
A date-time specification.

field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month …
.1.3.6.1.4.1.9.9.826.1.48.1.1.18
Cisco Firepower lsmaint:Ack:name managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.19
Cisco Firepower lsmaint:Ack:oldPnDn managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.20
Cisco Firepower lsmaint:Ack:operScheduler managed
object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.21
Cisco Firepower lsmaint:Ack:operState managed object property
CISCO-FIREPOWER-TC-MIBCfprTrigAckOperState
Type Values:
0untriggered
1evaluationPending
2evaluated
3waitingForUser
4waitingForMaintWindow
5applyPending
6applied
7waitingForDependency
8none
9expired
10pending
11active
.1.3.6.1.4.1.9.9.826.1.48.1.1.22
Cisco Firepower lsmaint:Ack:policyLevel managed object property
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.826.1.48.1.1.23
Cisco Firepower lsmaint:Ack:policyOwner managed object property
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner
Type Values:
0local
1policy
2pendingPolicy
.1.3.6.1.4.1.9.9.826.1.48.1.1.24
Cisco Firepower lsmaint:Ack:prevOperState managed
object property
CISCO-FIREPOWER-TC-MIBCfprTrigAckPrevOperState
Type Values:
0untriggered
1evaluationPending
2evaluated
3waitingForUser
4waitingForMaintWindow
5applyPending
6applied
7waitingForDependency
8none
9expired
10pending
11active
.1.3.6.1.4.1.9.9.826.1.48.1.1.25
Cisco Firepower lsmaint:Ack:scheduler managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.1.1.26
.1.3.6.1.4.1.9.9.826.1.48.2 · 1 row entry · 11 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfprLsmaintMaintPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-LSMAINT-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-LSMAINT-MIB::cfprLsmaintMaintPolicyTable'
Cisco Firepower lsmaint:MaintPolicy managed object table
cfprLsmaintMaintPolicyEntry row .1.3.6.1.4.1.9.9.826.1.48.2.1
Entry for the cfprLsmaintMaintPolicyTable table.
Column Syntax OID
Instance identifier of the managed object.
CISCO-FIREPOWER-MIBCfprManagedObjectId .1.3.6.1.4.1.9.9.826.1.48.2.1.1
Cisco Firepower lsmaint:MaintPolicy:dn managed object property
CISCO-FIREPOWER-MIBCfprManagedObjectDn .1.3.6.1.4.1.9.9.826.1.48.2.1.2
Cisco Firepower lsmaint:MaintPolicy:rn managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.3
Cisco Firepower lsmaint:MaintPolicy:descr managed
object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.4
Cisco Firepower lsmaint:MaintPolicy:intId managed
object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.5
Cisco Firepower lsmaint:MaintPolicy:name managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.6
Cisco Firepower lsmaint:MaintPolicy:operSchedName
managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.7
Cisco Firepower lsmaint:MaintPolicy:policyLevel
managed object property
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.826.1.48.2.1.8
Cisco Firepower lsmaint:MaintPolicy:policyOwner
managed object property
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner
Type Values:
0local
1policy
2pendingPolicy
.1.3.6.1.4.1.9.9.826.1.48.2.1.9
Cisco Firepower lsmaint:MaintPolicy:schedName
managed object property
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.826.1.48.2.1.10
Cisco Firepower lsmaint:MaintPolicy:uptimeDisr
managed object property
CISCO-FIREPOWER-TC-MIBCfprTrigAckMode
Type Values:
0immediate
1userAck
2timerAutomatic
.1.3.6.1.4.1.9.9.826.1.48.2.1.11