CISCO-FIREPOWER-COMPUTE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
65
Rows
65
Columns
986
.1.3.6.1.4.1.9.9.826.1.12.1
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeAutoconfigPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeAutoconfigPolicyTable'
Cisco Firepower compute:AutoconfigPolicy managed object table
Entry for the cfprComputeAutoconfigPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.1.1.1 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.1.1.2 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.3 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.4 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:dstDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.5 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.6 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.7 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.8 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.1.1.9 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.10 |
||||||
|
Cisco Firepower compute:AutoconfigPolicy:srcTemplName
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.1.1.11 |
cfprComputeBladeTable
table.1.3.6.1.4.1.9.9.826.1.12.2
·
1 row entry
·
69 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeTable'
Cisco Firepower compute:Blade managed object table
Entry for the cfprComputeBladeTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.2.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.2.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:adminPower managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeAdminPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:adminState managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeAdminState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:assignedToDn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:association managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAssociation Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:availability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAvailability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:availableMemory
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:chassisId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:checkPoint managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeCheckPoint Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:connPath managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:connStatus managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:discovery managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeDiscovery Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fltAggr managed object property
|
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.2.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmDescr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmFlags managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmPrev managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmProgr managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmRmtInvErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmRmtInvErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.22 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmRmtInvRslt managed
object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.23 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmStageDescr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.24 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmStamp managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.2.1.25 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmStatus managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.26 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:fsmTry managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.27 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.28 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:lc managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeAdminTrigger Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.29 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:lcTs managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.2.1.30 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:localId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.31 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:lowVoltageMemory
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalLowVoltageMemory Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.32 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:managingInst managed
object property |
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.33 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:memorySpeed managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.34 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:mfgTime managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.2.1.35 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.36 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.37 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfAdaptors managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.38 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfCores managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.39 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfCoresEnabled
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.40 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfCpus managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.41 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfEthHostIfs
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.42 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfFcHostIfs managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.43 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:numOfThreads managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.44 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:operPower managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.45 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:operQualifier managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeIssues Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.46 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:operState managed object property
|
CISCO-FIREPOWER-TC-MIBCfprLsOperState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.47 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:operability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.48 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:originalUuid managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.49 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:partNumber managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.50 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:policyLevel managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.51 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:policyOwner managed
object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.52 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:presence managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSlotStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.53 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:revision managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.54 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:scaledMode managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeMode Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.55 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.56 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:serverId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.57 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:slotId managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeBladeSlotId Type Constraints: range: 1..8 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.58 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:totalMemory managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.59 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:upgradeScenario
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeUpgradeStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.60 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:usrLbl managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.61 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:uuid managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.62 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.63 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:vid managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.64 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:lastAdaptorCrashReset
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.65 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:lastBiosHangReset
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.2.1.66 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:postState managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentBiosPostState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.2.1.67 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:postWaitCount managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.68 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Blade:resetCount managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.2.1.69 |
.1.3.6.1.4.1.9.9.826.1.12.3
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeDiscPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeDiscPolicyTable'
Cisco Firepower compute:BladeDiscPolicy managed object table
Entry for the cfprComputeBladeDiscPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.3.1.1 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.3.1.2 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.3 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:action
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.4 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.5 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.6 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:name managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.7 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.8 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.3.1.9 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.10 |
||||||
|
Cisco Firepower compute:BladeDiscPolicy:scrubPolicyName
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.3.1.11 |
cfprComputeBladeFsmTable
table.1.3.6.1.4.1.9.9.826.1.12.4
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeFsmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeFsmTable'
Cisco Firepower compute:BladeFsm managed object table
Entry for the cfprComputeBladeFsmTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.4.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.4.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.4.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:completionTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.4.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:currentFsm managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBladeFsmCurrentFsm Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.4.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.4.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:fsmStatus managed
object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.4.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:progress managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.4.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:rmtErrCode managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.4.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:rmtErrDescr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.4.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsm:rmtRslt managed object property
|
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.4.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.5
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeFsmStageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeFsmStageTable'
Cisco Firepower compute:BladeFsmStage managed object table
Entry for the cfprComputeBladeFsmStageTable table.
| Column | Syntax | OID | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.5.1.1 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.5.1.2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.5.1.3 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.5.1.4 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:lastUpdateTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.5.1.5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:name managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBladeFsmStageName Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.5.1.6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:order managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.5.1.7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:retry managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.5.1.8 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BladeFsmStage:stageStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.5.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.6
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeFsmTaskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeFsmTaskTable'
Cisco Firepower compute:BladeFsmTask managed object table
Entry for the cfprComputeBladeFsmTaskTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.6.1.1 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.6.1.2 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.6.1.3 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:completion
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmCompletion Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.6.1.4 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:flags managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBladeFsmTaskFlags Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.6.1.5 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:item managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBladeFsmTaskItem Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.6.1.6 |
||||||||
|
Cisco Firepower compute:BladeFsmTask:seqId managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.6.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.7
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBladeInheritPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBladeInheritPolicyTable'
Cisco Firepower compute:BladeInheritPolicy managed object table
Entry for the cfprComputeBladeInheritPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.7.1.1 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.7.1.2 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.3 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.4 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:dstDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.5 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.6 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.7 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.8 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.7.1.9 |
||||||
|
Cisco Firepower compute:BladeInheritPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.7.1.10 |
cfprComputeBoardTable
table.1.3.6.1.4.1.9.9.826.1.12.8
·
1 row entry
·
22 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBoardTable'
Cisco Firepower compute:Board managed object table
Entry for the cfprComputeBoardTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.8.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.8.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:cmosVoltage managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:cpuType managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentCpuType Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:faultQualifier managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:locationDn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:operPower managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:operState managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:operability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:perf managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:power managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeABoardPower Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:powerUsage managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:presence managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:revision managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:thermal managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.8.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:Board:voltage managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.8.1.22 |
.1.3.6.1.4.1.9.9.826.1.12.9
·
1 row entry
·
6 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBoardConnectorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBoardConnectorTable'
Cisco Firepower compute:BoardConnector managed object table
Entry for the cfprComputeBoardConnectorTable table.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.9.1.1 |
||||
|
Cisco Firepower compute:BoardConnector:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.9.1.2 |
||||
|
Cisco Firepower compute:BoardConnector:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.9.1.3 |
||||
|
Cisco Firepower compute:BoardConnector:boardConnectorType
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentBoardConnectorType Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.9.1.4 |
||||
|
Cisco Firepower compute:BoardConnector:masterSlotId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.9.1.5 |
||||
|
Cisco Firepower compute:BoardConnector:slaveSlotId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.9.1.6 |
.1.3.6.1.4.1.9.9.826.1.12.10
·
1 row entry
·
17 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeBoardControllerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeBoardControllerTable'
Cisco Firepower compute:BoardController managed object table
Entry for the cfprComputeBoardControllerTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.10.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.10.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:id managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:locationDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:model
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:operState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:operability
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:perf managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:power
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:presence
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:revision
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:serial
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:thermal
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:vendor
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.10.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:BoardController:voltage
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.10.1.17 |
.1.3.6.1.4.1.9.9.826.1.12.11
·
1 row entry
·
12 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeChassisConnPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeChassisConnPolicyTable'
Cisco Firepower compute:ChassisConnPolicy managed object table
Entry for the cfprComputeChassisConnPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.11.1.1 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.11.1.2 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.3 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:adminState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAdminLinkAggregation Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.11.1.4 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:chassisId
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeChassisConnPolicyChassisId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.5 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.6 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.7 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.8 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.9 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.11.1.10 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.11.1.11 |
||||||
|
Cisco Firepower compute:ChassisConnPolicy:switchId
managed object property |
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.11.1.12 |
.1.3.6.1.4.1.9.9.826.1.12.12
·
1 row entry
·
12 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeChassisDiscPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeChassisDiscPolicyTable'
Cisco Firepower compute:ChassisDiscPolicy managed object table
Entry for the cfprComputeChassisDiscPolicyTable table.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.12.1.1 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.12.1.2 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.3 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:action
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeChassisDiscAction Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.12.1.4 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.5 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.6 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:linkAggregationPref
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeLinkAggregation Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.12.1.7 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.8 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.9 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.12.1.10 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.12.1.11 |
||||||||||||||
|
Cisco Firepower compute:ChassisDiscPolicy:rebalance
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeConnectivityRebalancing Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.12.1.12 |
.1.3.6.1.4.1.9.9.826.1.12.13
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeChassisQualTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeChassisQualTable'
Cisco Firepower compute:ChassisQual managed object table
Entry for the cfprComputeChassisQualTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.13.1.1 |
|
Cisco Firepower compute:ChassisQual:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.13.1.2 |
|
Cisco Firepower compute:ChassisQual:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.13.1.3 |
|
Cisco Firepower compute:ChassisQual:maxId managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeChassisQualMaxId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.13.1.4 |
|
Cisco Firepower compute:ChassisQual:minId managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeChassisQualMinId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.13.1.5 |
cfprComputeDefaultsTable
table.1.3.6.1.4.1.9.9.826.1.12.14
·
1 row entry
·
3 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeDefaultsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeDefaultsTable'
Cisco Firepower compute:Defaults managed object table
Entry for the cfprComputeDefaultsTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.14.1.1 |
|
Cisco Firepower compute:Defaults:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.14.1.2 |
|
Cisco Firepower compute:Defaults:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.14.1.3 |
cfprComputeExtBoardTable
table.1.3.6.1.4.1.9.9.826.1.12.15
·
1 row entry
·
27 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeExtBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeExtBoardTable'
Cisco Firepower compute:ExtBoard managed object table
Entry for the cfprComputeExtBoardTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.15.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.15.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:boardAggregationRole
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentBoardAggregationRole Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:chassisId managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:cmosVoltage managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:connPath managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:connStatus managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:faultQualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:locationDn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:managingInst
managed object property |
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:operPower managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:operState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:operability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:perf managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:power managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeABoardPower Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:powerUsage managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:presence managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:revision managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.22 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.23 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:slotId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.24 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:thermal managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.25 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.15.1.26 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ExtBoard:voltage managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.15.1.27 |
.1.3.6.1.4.1.9.9.826.1.12.16
·
1 row entry
·
22 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeFwSyncAckTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeFwSyncAckTable'
Cisco Firepower compute:FwSyncAck managed object table
Entry for the cfprComputeFwSyncAckTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.16.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.16.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:acked managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.16.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:ackedBy managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:adminState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprTrigAdminState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:autoDelete managed
object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.16.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:changeBy managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:changeDetails
managed object property |
CISCO-FIREPOWER-TC-MIBCfprTrigAckChangeDetails Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:changes managed
object property |
CISCO-FIREPOWER-TC-MIBCfprTrigAckChanges Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:disr managed object property
|
CISCO-FIREPOWER-TC-MIBCfprTrigAckDisr Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:ignoreCap managed
object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.16.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:modified managed
object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.16.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:operScheduler
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:operState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprTrigAckOperState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:prevOperState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprTrigAckPrevOperState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.16.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:FwSyncAck:scheduler managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.16.1.22 |
.1.3.6.1.4.1.9.9.826.1.12.17
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeHealthLedSensorAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeHealthLedSensorAlarmTable'
Cisco Firepower compute:HealthLedSensorAlarm managed object table
Entry for the cfprComputeHealthLedSensorAlarmTable table.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.17.1.1 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.17.1.2 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.17.1.3 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:alarmDesc
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.17.1.4 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:alarmSeverity
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAlarmSeverity Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.17.1.5 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:sensorId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.17.1.6 |
||||
|
Cisco Firepower compute:HealthLedSensorAlarm:sensorName
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.17.1.7 |
cfprComputeIOHubTable
table.1.3.6.1.4.1.9.9.826.1.12.18
·
1 row entry
·
17 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeIOHubTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeIOHubTable'
Cisco Firepower compute:IOHub managed object table
Entry for the cfprComputeIOHubTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.18.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.18.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:locationDn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:operState managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:operability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:perf managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:power managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:presence managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:revision managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:thermal managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.18.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:IOHub:voltage managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.18.1.17 |
.1.3.6.1.4.1.9.9.826.1.12.19
·
1 row entry
·
12 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeIOHubEnvStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeIOHubEnvStatsTable'
Cisco Firepower compute:IOHubEnvStats managed object table
Entry for the cfprComputeIOHubEnvStatsTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.19.1.1 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.19.1.2 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.3 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.4 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.19.1.5 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:temperature
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.6 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:temperatureAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.7 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:temperatureMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.8 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:temperatureMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.9 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeIOHubEnvStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.19.1.10 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.19.1.11 |
||||||||
|
Cisco Firepower compute:IOHubEnvStats:update managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.19.1.12 |
.1.3.6.1.4.1.9.9.826.1.12.20
·
1 row entry
·
12 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeIOHubEnvStatsHistTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeIOHubEnvStatsHistTable'
Cisco Firepower compute:IOHubEnvStatsHist managed object table
Entry for the cfprComputeIOHubEnvStatsHistTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.20.1.1 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.20.1.2 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.20.1.3 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:id managed
object property |
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.20.1.4 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:mostRecent
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.20.1.5 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.20.1.6 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:temperature
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.20.1.7 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:temperatureAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.20.1.8 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:temperatureMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.20.1.9 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:temperatureMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.20.1.10 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeIOHubEnvStatsHistThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.20.1.11 |
||||||||
|
Cisco Firepower compute:IOHubEnvStatsHist:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.20.1.12 |
.1.3.6.1.4.1.9.9.826.1.12.21
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeKvmMgmtPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeKvmMgmtPolicyTable'
Cisco Firepower compute:KvmMgmtPolicy managed object table
Entry for the cfprComputeKvmMgmtPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.21.1.1 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.21.1.2 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.21.1.3 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.21.1.4 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:intId managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.21.1.5 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:name managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.21.1.6 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.21.1.7 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.21.1.8 |
||||||
|
Cisco Firepower compute:KvmMgmtPolicy:vmediaEncryption
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeKvmMgmtPolicyVmediaEncryption Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.21.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.22
·
1 row entry
·
20 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMbPowerStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMbPowerStatsTable'
Cisco Firepower compute:MbPowerStats managed object table
Entry for the cfprComputeMbPowerStatsTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.22.1.1 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.22.1.2 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.3 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:consumedPower
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.4 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:consumedPowerAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.5 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:consumedPowerMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.6 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:consumedPowerMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.7 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputCurrent
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.8 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputCurrentAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.9 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputCurrentMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.10 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputCurrentMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.11 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputVoltage
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.12 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputVoltageAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.13 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputVoltageMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.14 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:inputVoltageMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.15 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.16 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:suspect managed
object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.22.1.17 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeMbPowerStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.22.1.18 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.22.1.19 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStats:update managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.22.1.20 |
.1.3.6.1.4.1.9.9.826.1.12.23
·
1 row entry
·
20 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMbPowerStatsHistTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMbPowerStatsHistTable'
Cisco Firepower compute:MbPowerStatsHist managed object table
Entry for the cfprComputeMbPowerStatsHistTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.23.1.1 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.23.1.2 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.3 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:consumedPower
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.4 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:consumedPowerAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.5 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:consumedPowerMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.6 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:consumedPowerMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.7 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:id managed
object property |
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.23.1.8 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputCurrent
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.9 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputCurrentAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.10 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputCurrentMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.11 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputCurrentMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.12 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputVoltage
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.13 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputVoltageAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.14 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputVoltageMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.15 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:inputVoltageMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.23.1.16 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:mostRecent
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.23.1.17 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.23.1.18 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeMbPowerStatsHistThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.23.1.19 |
||||||||||||||||||||||||
|
Cisco Firepower compute:MbPowerStatsHist:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.23.1.20 |
.1.3.6.1.4.1.9.9.826.1.12.24
·
1 row entry
·
24 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMbTempStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMbTempStatsTable'
Cisco Firepower compute:MbTempStats managed object table
Entry for the cfprComputeMbTempStatsTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.24.1.1 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.24.1.2 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.3 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenIo
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.4 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenIoAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.5 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenIoMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.6 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenIoMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.7 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRear
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.8 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.9 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearL
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.10 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearLAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.11 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearLMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.12 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearLMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.13 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.14 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.15 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearR
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.16 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearRAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.17 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearRMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.18 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:fmTempSenRearRMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.19 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.20 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:suspect managed
object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.24.1.21 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeMbTempStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.24.1.22 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.24.1.23 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStats:update managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.24.1.24 |
.1.3.6.1.4.1.9.9.826.1.12.25
·
1 row entry
·
24 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMbTempStatsHistTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMbTempStatsHistTable'
Cisco Firepower compute:MbTempStatsHist managed object table
Entry for the cfprComputeMbTempStatsHistTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.25.1.1 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.25.1.2 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.3 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenIo
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.4 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenIoAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.5 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenIoMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.6 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenIoMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.7 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRear
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.8 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.9 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearL
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.10 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.11 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.12 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.13 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.14 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.15 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearR
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.16 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.17 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.18 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.25.1.19 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:id managed
object property |
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.25.1.20 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:mostRecent
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.25.1.21 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.25.1.22 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeMbTempStatsHistThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.25.1.23 |
||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:MbTempStatsHist:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.25.1.24 |
.1.3.6.1.4.1.9.9.826.1.12.26
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMemoryConfigPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMemoryConfigPolicyTable'
Cisco Firepower compute:MemoryConfigPolicy managed object table
Entry for the cfprComputeMemoryConfigPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.26.1.1 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.26.1.2 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.26.1.3 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:blackListing
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBlackListing Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.26.1.4 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.26.1.5 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.26.1.6 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.26.1.7 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.26.1.8 |
||||||
|
Cisco Firepower compute:MemoryConfigPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.26.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.27
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMemoryConfigurationTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMemoryConfigurationTable'
Cisco Firepower compute:MemoryConfiguration managed object table
Entry for the cfprComputeMemoryConfigurationTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.27.1.1 |
||||||
|
Cisco Firepower compute:MemoryConfiguration:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.27.1.2 |
||||||
|
Cisco Firepower compute:MemoryConfiguration:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.27.1.3 |
||||||
|
Cisco Firepower compute:MemoryConfiguration:adminMemoryState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAdminMemoryState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.27.1.4 |
||||||
|
Cisco Firepower compute:MemoryConfiguration:blackListing
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeBlackListing Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.27.1.5 |
.1.3.6.1.4.1.9.9.826.1.12.28
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeMemoryUnitConstraintDefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeMemoryUnitConstraintDefTable'
Cisco Firepower compute:MemoryUnitConstraintDef managed object table
Entry for the cfprComputeMemoryUnitConstraintDefTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.28.1.1 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.28.1.2 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.3 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.4 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.5 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.6 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.7 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.28.1.8 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:revisionModifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.28.1.9 |
||||||
|
Cisco Firepower compute:MemoryUnitConstraintDef:type
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeMemoryUnitConstraintType Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.28.1.10 |
.1.3.6.1.4.1.9.9.826.1.12.29
·
1 row entry
·
41 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePCIeFatalCompletionStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePCIeFatalCompletionStatsTable'
Cisco Firepower compute:PCIeFatalCompletionStats managed object table
Entry for the cfprComputePCIeFatalCompletionStatsTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.29.1.1 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.29.1.2 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.3 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.4 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.5 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors15Min
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.6 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.7 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.8 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.9 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Hour
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.10 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.11 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Week
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.12 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors2Week
s managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.13 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors2Week
sH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.14 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.15 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors15M
in managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.16 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors15M
inH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.17 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Da
y managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.18 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Da
yH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.19 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Ho
ur managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.20 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Ho
urH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.21 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1We
ek managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.22 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1We
ekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.23 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors2We
eks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.24 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors2We
eksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.25 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.26 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.29.1.27 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePCIeFatalCompletionStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.29.1.28 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.29.1.29 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.30 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
15Min managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.31 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
15MinH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.32 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1Day managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.33 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1DayH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.34 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1Hour managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.35 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1HourH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.36 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1Week managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.37 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
1WeekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.38 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
2Weeks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.39 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors
2WeeksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.40 |
||||||
|
Cisco Firepower compute:PCIeFatalCompletionStats:update
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.29.1.41 |
.1.3.6.1.4.1.9.9.826.1.12.30
·
1 row entry
·
30 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePCIeFatalProtocolStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePCIeFatalProtocolStatsTable'
Cisco Firepower compute:PCIeFatalProtocolStats managed object table
Entry for the cfprComputePCIeFatalProtocolStatsTable table.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.30.1.1 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.30.1.2 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.3 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.4 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.5 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors15MinH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.6 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.7 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.8 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.9 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1HourH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.10 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.11 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1WeekH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.12 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors2Weeks
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.13 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors2WeeksH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.14 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.15 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
5Min managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.16 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
5MinH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.17 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
Day managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.18 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
DayH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.19 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
Hour managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.20 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
HourH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.21 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
Week managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.22 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1
WeekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.23 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors2
Weeks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.24 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors2
WeeksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.25 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.26 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.30.1.27 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePCIeFatalProtocolStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.30.1.28 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.30.1.29 |
||||
|
Cisco Firepower compute:PCIeFatalProtocolStats:update
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.30.1.30 |
.1.3.6.1.4.1.9.9.826.1.12.31
·
1 row entry
·
52 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePCIeFatalReceiveStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePCIeFatalReceiveStatsTable'
Cisco Firepower compute:PCIeFatalReceiveStats managed object table
Entry for the cfprComputePCIeFatalReceiveStatsTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.31.1.1 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.31.1.2 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.3 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.4 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s15Min managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.5 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s15MinH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.6 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1Day managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.7 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1DayH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.8 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1Hour managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.9 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1HourH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.10 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1Week managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.11 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s1WeekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.12 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s2Weeks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.13 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError
s2WeeksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.14 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.15 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.16 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors15Min
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.17 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.18 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.19 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.20 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Hour
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.21 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.22 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Week
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.23 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors2Week
s managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.24 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors2Week
sH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.25 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.26 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors15
Min managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.27 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors15
MinH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.28 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1D
ay managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.29 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1D
ayH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.30 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1H
our managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.31 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1H
ourH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.32 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1W
eek managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.33 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1W
eekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.34 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors2W
eeks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.35 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors2W
eeksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.36 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.37 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.31.1.38 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePCIeFatalReceiveStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.31.1.39 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.31.1.40 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.41 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors15Min managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.42 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors15MinH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.43 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1Day managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.44 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1DayH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.45 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1Hour managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.46 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1HourH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.47 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1Week managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.48 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors1WeekH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.49 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors2Weeks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.50 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE
rrors2WeeksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.51 |
||||||||
|
Cisco Firepower compute:PCIeFatalReceiveStats:update
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.31.1.52 |
.1.3.6.1.4.1.9.9.826.1.12.32
·
1 row entry
·
52 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePCIeFatalStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePCIeFatalStatsTable'
Cisco Firepower compute:PCIeFatalStats managed object table
Entry for the cfprComputePCIeFatalStatsTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.32.1.1 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.32.1.2 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.3 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.4 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.5 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors15MinH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.6 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.7 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.8 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.9 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1HourH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.10 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.11 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1WeekH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.12 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors2Weeks
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.13 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:acsViolationErrors2WeeksH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.14 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.15 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.16 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.17 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors15MinH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.18 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.19 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.20 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.21 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1HourH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.22 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.23 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1WeekH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.24 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors2Weeks
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.25 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors2WeeksH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.26 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.27 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors15Min
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.28 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors15MinH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.29 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.30 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1DayH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.31 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Hour
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.32 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1HourH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.33 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Week
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.34 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1WeekH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.35 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors2Weeks
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.36 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors2WeeksH
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.37 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors
managed object property |
SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.38 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors15Mi
n managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.39 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors15Mi
nH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.40 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Day
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.41 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Day
H managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.42 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Hou
r managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.43 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Hou
rH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.44 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Wee
k managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.45 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Wee
kH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.46 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors2Wee
ks managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.47 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors2Wee
ksH managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.48 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.32.1.49 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePCIeFatalStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.32.1.50 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.32.1.51 |
||||||||
|
Cisco Firepower compute:PCIeFatalStats:update
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.32.1.52 |
cfprComputePciCapTable
table.1.3.6.1.4.1.9.9.826.1.12.33
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePciCapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePciCapTable'
Cisco Firepower compute:PciCap managed object table
Entry for the cfprComputePciCapTable table.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.33.1.1 |
||||||||||
|
Cisco Firepower compute:PciCap:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.33.1.2 |
||||||||||
|
Cisco Firepower compute:PciCap:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.33.1.3 |
||||||||||
|
Cisco Firepower compute:PciCap:maxBusIdPerSlot
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.33.1.4 |
||||||||||
|
Cisco Firepower compute:PciCap:numOfPhysSlots
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.33.1.5 |
||||||||||
|
Cisco Firepower compute:PciCap:order managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputePciCapOrder Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.33.1.6 |
||||||||||
|
Cisco Firepower compute:PciCap:startsWith managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.33.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.34
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePciSlotScanDefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePciSlotScanDefTable'
Cisco Firepower compute:PciSlotScanDef managed object table
Entry for the cfprComputePciSlotScanDefTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.34.1.1 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.34.1.2 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.3 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.4 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:intId managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.5 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:name managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.6 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.7 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.34.1.8 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:scanOrder
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.9 |
||||||
|
Cisco Firepower compute:PciSlotScanDef:slotId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.34.1.10 |
.1.3.6.1.4.1.9.9.826.1.12.35
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePhysicalAssocCtxTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePhysicalAssocCtxTable'
Cisco Firepower compute:PhysicalAssocCtx managed object table
Entry for the cfprComputePhysicalAssocCtxTable table.
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.35.1.1 |
|
Cisco Firepower compute:PhysicalAssocCtx:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.35.1.2 |
|
Cisco Firepower compute:PhysicalAssocCtx:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.35.1.3 |
|
Cisco Firepower compute:PhysicalAssocCtx:fruCapDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.35.1.4 |
.1.3.6.1.4.1.9.9.826.1.12.36
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePhysicalFsmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePhysicalFsmTable'
Cisco Firepower compute:PhysicalFsm managed object table
Entry for the cfprComputePhysicalFsmTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.36.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.36.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.36.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:completionTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.36.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:currentFsm
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalFsmCurrentFsm Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.36.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.36.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:fsmStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.36.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:progress managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.36.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:rmtErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.36.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:rmtErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.36.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsm:rmtRslt managed
object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.36.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.37
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePhysicalFsmStageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePhysicalFsmStageTable'
Cisco Firepower compute:PhysicalFsmStage managed object table
Entry for the cfprComputePhysicalFsmStageTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.37.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.37.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.37.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.37.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:lastUpdateTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.37.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:name
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalFsmStageName Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.37.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:order
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.37.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:retry
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.37.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmStage:stageStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.37.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.38
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePhysicalFsmTaskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePhysicalFsmTaskTable'
Cisco Firepower compute:PhysicalFsmTask managed object table
Entry for the cfprComputePhysicalFsmTaskTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.38.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.38.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.38.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:completion
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmCompletion Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.38.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:flags
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalFsmTaskFlags Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.38.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:item managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalFsmTaskItem Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.38.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:PhysicalFsmTask:seqId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.38.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.39
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePhysicalQualTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePhysicalQualTable'
Cisco Firepower compute:PhysicalQual managed object table
Entry for the cfprComputePhysicalQualTable table.
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.39.1.1 |
|
Cisco Firepower compute:PhysicalQual:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.39.1.2 |
|
Cisco Firepower compute:PhysicalQual:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.39.1.3 |
|
Cisco Firepower compute:PhysicalQual:model managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.39.1.4 |
cfprComputePlatformTable
table.1.3.6.1.4.1.9.9.826.1.12.40
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePlatformTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePlatformTable'
Cisco Firepower compute:Platform managed object table
Entry for the cfprComputePlatformTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.40.1.1 |
|
Cisco Firepower compute:Platform:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.40.1.2 |
|
Cisco Firepower compute:Platform:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.40.1.3 |
|
Cisco Firepower compute:Platform:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.40.1.4 |
|
Cisco Firepower compute:Platform:productName managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.40.1.5 |
|
Cisco Firepower compute:Platform:revision managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.40.1.6 |
|
Cisco Firepower compute:Platform:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.40.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.41
·
1 row entry
·
6 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePnuOSImageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePnuOSImageTable'
Cisco Firepower compute:PnuOSImage managed object table
Entry for the cfprComputePnuOSImageTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.41.1.1 |
|
Cisco Firepower compute:PnuOSImage:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.41.1.2 |
|
Cisco Firepower compute:PnuOSImage:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.41.1.3 |
|
Cisco Firepower compute:PnuOSImage:imgLFBFFName
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.41.1.4 |
|
Cisco Firepower compute:PnuOSImage:imgLoc managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.41.1.5 |
|
Cisco Firepower compute:PnuOSImage:imgName managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.41.1.6 |
cfprComputePoolTable
table.1.3.6.1.4.1.9.9.826.1.12.42
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePoolTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePoolTable'
Cisco Firepower compute:Pool managed object table
Entry for the cfprComputePoolTable table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.42.1.1 |
||||||
|
Cisco Firepower compute:Pool:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.42.1.2 |
||||||
|
Cisco Firepower compute:Pool:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.3 |
||||||
|
Cisco Firepower compute:Pool:assigned managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.4 |
||||||
|
Cisco Firepower compute:Pool:assignmentOrder managed
object property |
CISCO-FIREPOWER-TC-MIBCfprPoolPoolAssignmentOrder Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.42.1.5 |
||||||
|
Cisco Firepower compute:Pool:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.6 |
||||||
|
Cisco Firepower compute:Pool:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.7 |
||||||
|
Cisco Firepower compute:Pool:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.8 |
||||||
|
Cisco Firepower compute:Pool:policyLevel managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.9 |
||||||
|
Cisco Firepower compute:Pool:policyOwner managed object property
|
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.42.1.10 |
||||||
|
Cisco Firepower compute:Pool:size managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.42.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.43
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePoolPolicyRefTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePoolPolicyRefTable'
Cisco Firepower compute:PoolPolicyRef managed object table
Entry for the cfprComputePoolPolicyRefTable table.
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.43.1.1 |
|
Cisco Firepower compute:PoolPolicyRef:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.43.1.2 |
|
Cisco Firepower compute:PoolPolicyRef:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.43.1.3 |
|
Cisco Firepower compute:PoolPolicyRef:id managed object property
|
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.43.1.4 |
|
Cisco Firepower compute:PoolPolicyRef:policyDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.43.1.5 |
cfprComputePoolableTable
table.1.3.6.1.4.1.9.9.826.1.12.44
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePoolableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePoolableTable'
Cisco Firepower compute:Poolable managed object table
Entry for the cfprComputePoolableTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.44.1.1 |
|
Cisco Firepower compute:Poolable:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.44.1.2 |
|
Cisco Firepower compute:Poolable:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.44.1.3 |
|
Cisco Firepower compute:Poolable:id managed object property
|
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.44.1.4 |
|
Cisco Firepower compute:Poolable:poolDn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.44.1.5 |
.1.3.6.1.4.1.9.9.826.1.12.45
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePooledRackUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePooledRackUnitTable'
Cisco Firepower compute:PooledRackUnit managed object table
Entry for the cfprComputePooledRackUnitTable table.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.45.1.1 |
||||
|
Cisco Firepower compute:PooledRackUnit:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.45.1.2 |
||||
|
Cisco Firepower compute:PooledRackUnit:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.45.1.3 |
||||
|
Cisco Firepower compute:PooledRackUnit:assigned
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.45.1.4 |
||||
|
Cisco Firepower compute:PooledRackUnit:assignedToDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.45.1.5 |
||||
|
Cisco Firepower compute:PooledRackUnit:id managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputePooledRackUnitId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.45.1.6 |
||||
|
Cisco Firepower compute:PooledRackUnit:owner managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.45.1.7 |
||||
|
Cisco Firepower compute:PooledRackUnit:poolableDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.45.1.8 |
||||
|
Cisco Firepower compute:PooledRackUnit:prevAssignedToDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.45.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.46
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePooledSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePooledSlotTable'
Cisco Firepower compute:PooledSlot managed object table
Entry for the cfprComputePooledSlotTable table.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.46.1.1 |
||||
|
Cisco Firepower compute:PooledSlot:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.46.1.2 |
||||
|
Cisco Firepower compute:PooledSlot:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.3 |
||||
|
Cisco Firepower compute:PooledSlot:assigned managed
object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.46.1.4 |
||||
|
Cisco Firepower compute:PooledSlot:assignedToDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.5 |
||||
|
Cisco Firepower compute:PooledSlot:chassisId managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.6 |
||||
|
Cisco Firepower compute:PooledSlot:owner managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.46.1.7 |
||||
|
Cisco Firepower compute:PooledSlot:poolableDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.8 |
||||
|
Cisco Firepower compute:PooledSlot:prevAssignedToDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.9 |
||||
|
Cisco Firepower compute:PooledSlot:slotId managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputePooledSlotSlotId Type Constraints: range: 1..8 |
.1.3.6.1.4.1.9.9.826.1.12.46.1.10 |
.1.3.6.1.4.1.9.9.826.1.12.47
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePoolingPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePoolingPolicyTable'
Cisco Firepower compute:PoolingPolicy managed object table
Entry for the cfprComputePoolingPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.47.1.1 |
||||||
|
Cisco Firepower compute:PoolingPolicy:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.47.1.2 |
||||||
|
Cisco Firepower compute:PoolingPolicy:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.3 |
||||||
|
Cisco Firepower compute:PoolingPolicy:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.4 |
||||||
|
Cisco Firepower compute:PoolingPolicy:intId managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.5 |
||||||
|
Cisco Firepower compute:PoolingPolicy:name managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.6 |
||||||
|
Cisco Firepower compute:PoolingPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.7 |
||||||
|
Cisco Firepower compute:PoolingPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.47.1.8 |
||||||
|
Cisco Firepower compute:PoolingPolicy:poolDn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.9 |
||||||
|
Cisco Firepower compute:PoolingPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.47.1.10 |
.1.3.6.1.4.1.9.9.826.1.12.48
·
1 row entry
·
14 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePsuControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePsuControlTable'
Cisco Firepower compute:PsuControl managed object table
Entry for the cfprComputePsuControlTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.48.1.1 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.48.1.2 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.48.1.3 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:clusterState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePsuClusterState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.4 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.48.1.5 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:inputPowerState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.6 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.48.1.7 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.48.1.8 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:operQualifier
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePsuRedundancyOperQualifier Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.9 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:operState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputePsuRedundancyOperState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.10 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:outputPowerState
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.11 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.48.1.12 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.13 |
||||||||||||||||||
|
Cisco Firepower compute:PsuControl:redundancy
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePsuControlRedundancy Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.48.1.14 |
.1.3.6.1.4.1.9.9.826.1.12.49
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputePsuPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputePsuPolicyTable'
Cisco Firepower compute:PsuPolicy managed object table
Entry for the cfprComputePsuPolicyTable table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.49.1.1 |
||||||
|
Cisco Firepower compute:PsuPolicy:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.49.1.2 |
||||||
|
Cisco Firepower compute:PsuPolicy:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.49.1.3 |
||||||
|
Cisco Firepower compute:PsuPolicy:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.49.1.4 |
||||||
|
Cisco Firepower compute:PsuPolicy:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.49.1.5 |
||||||
|
Cisco Firepower compute:PsuPolicy:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.49.1.6 |
||||||
|
Cisco Firepower compute:PsuPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.49.1.7 |
||||||
|
Cisco Firepower compute:PsuPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.49.1.8 |
||||||
|
Cisco Firepower compute:PsuPolicy:redundancy managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputePsuRedundancy Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.49.1.9 |
cfprComputeQualTable
table.1.3.6.1.4.1.9.9.826.1.12.50
·
1 row entry
·
8 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeQualTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeQualTable'
Cisco Firepower compute:Qual managed object table
Entry for the cfprComputeQualTable table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.50.1.1 |
||||||
|
Cisco Firepower compute:Qual:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.50.1.2 |
||||||
|
Cisco Firepower compute:Qual:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.50.1.3 |
||||||
|
Cisco Firepower compute:Qual:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.50.1.4 |
||||||
|
Cisco Firepower compute:Qual:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.50.1.5 |
||||||
|
Cisco Firepower compute:Qual:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.50.1.6 |
||||||
|
Cisco Firepower compute:Qual:policyLevel managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.50.1.7 |
||||||
|
Cisco Firepower compute:Qual:policyOwner managed object property
|
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.50.1.8 |
cfprComputeRackQualTable
table.1.3.6.1.4.1.9.9.826.1.12.51
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackQualTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackQualTable'
Cisco Firepower compute:RackQual managed object table
Entry for the cfprComputeRackQualTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.51.1.1 |
|
Cisco Firepower compute:RackQual:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.51.1.2 |
|
Cisco Firepower compute:RackQual:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.51.1.3 |
|
Cisco Firepower compute:RackQual:maxId managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeRackQualMaxId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.51.1.4 |
|
Cisco Firepower compute:RackQual:minId managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeRackQualMinId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.51.1.5 |
cfprComputeRackUnitTable
table.1.3.6.1.4.1.9.9.826.1.12.52
·
1 row entry
·
63 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitTable'
Cisco Firepower compute:RackUnit managed object table
Entry for the cfprComputeRackUnitTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.52.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.52.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:adminPower managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAdminPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:adminState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAdminState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:assignedToDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:association managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAssociation Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:availability
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeAvailability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:availableMemory
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:checkPoint managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeCheckPoint Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:connPath managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:connStatus managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentConnectionStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:descr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:discovery managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeDiscovery Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fltAggr managed object property
|
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.52.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmDescr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmFlags managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmPrev managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmProgr managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmRmtInvErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmRmtInvErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmRmtInvRslt
managed object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.22 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmStageDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.23 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmStamp managed
object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.52.1.24 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmStatus managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.25 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:fsmTry managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.26 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:id managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitId Type Constraints: range: 1..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.27 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:intId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.28 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:lc managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeAdminTrigger Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.29 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:lcTs managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.52.1.30 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:localId managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.31 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:lowVoltageMemory
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputePhysicalLowVoltageMemory Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.32 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:managingInst
managed object property |
CISCO-FIREPOWER-TC-MIBCfprNetworkSwitchId Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.33 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:memorySpeed managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.34 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:mfgTime managed object property
|
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.52.1.35 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.36 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.37 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfAdaptors
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.38 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfCores managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.39 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfCoresEnabled
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.40 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfCpus managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.41 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfEthHostIfs
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.42 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfFcHostIfs
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.43 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:numOfThreads
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.44 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:operPower managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.45 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:operQualifier
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeIssues Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.46 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:operState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprLsOperState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.47 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:operability managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.48 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:originalUuid
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.49 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:partNumber managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.50 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:policyLevel managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.51 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:policyOwner managed
object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.52 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:presence managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSlotStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.53 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:revision managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.54 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.55 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:serverId managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.56 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:totalMemory managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.57 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:usrLbl managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.58 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:uuid managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.59 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.60 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:versionHolder
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.52.1.61 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:vid managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.52.1.62 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnit:postState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentBiosPostState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.52.1.63 |
.1.3.6.1.4.1.9.9.826.1.12.53
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitFsmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitFsmTable'
Cisco Firepower compute:RackUnitFsm managed object table
Entry for the cfprComputeRackUnitFsmTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.53.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.53.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.53.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:completionTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.53.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:currentFsm
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitFsmCurrentFsm Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.53.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.53.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:fsmStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.53.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:progress managed
object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.53.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:rmtErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.53.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:rmtErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.53.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsm:rmtRslt managed
object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.53.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.54
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitFsmStageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitFsmStageTable'
Cisco Firepower compute:RackUnitFsmStage managed object table
Entry for the cfprComputeRackUnitFsmStageTable table.
| Column | Syntax | OID | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.54.1.1 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.54.1.2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.54.1.3 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.54.1.4 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:lastUpdateTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.54.1.5 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:name
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitFsmStageName Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.54.1.6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:order
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.54.1.7 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:retry
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.54.1.8 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitFsmStage:stageStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.54.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.55
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitFsmTaskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitFsmTaskTable'
Cisco Firepower compute:RackUnitFsmTask managed object table
Entry for the cfprComputeRackUnitFsmTaskTable table.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.55.1.1 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.55.1.2 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.55.1.3 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:completion
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmCompletion Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.55.1.4 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:flags
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitFsmTaskFlags Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.55.1.5 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:item managed
object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitFsmTaskItem Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.55.1.6 |
||||||||||
|
Cisco Firepower compute:RackUnitFsmTask:seqId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.55.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.56
·
1 row entry
·
28 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitMbTempStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitMbTempStatsTable'
Cisco Firepower compute:RackUnitMbTempStats managed object table
Entry for the cfprComputeRackUnitMbTempStatsTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.56.1.1 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.56.1.2 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.3 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ambientTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.4 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ambientTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.5 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ambientTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.6 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ambientTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.7 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:frontTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.8 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:frontTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.9 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:frontTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.10 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:frontTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.11 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:intervals
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.12 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh1Temp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.13 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh1TempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.14 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh1TempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.15 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh1TempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.16 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh2Temp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.17 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh2TempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.18 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh2TempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.19 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:ioh2TempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.20 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:rearTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.21 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:rearTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.22 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:rearTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.23 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:rearTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.24 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.56.1.25 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitMbTempStatsThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.56.1.26 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.56.1.27 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStats:update
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.56.1.28 |
.1.3.6.1.4.1.9.9.826.1.12.57
·
1 row entry
·
28 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRackUnitMbTempStatsHistTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRackUnitMbTempStatsHistTable'
Cisco Firepower compute:RackUnitMbTempStatsHist managed object table
Entry for the cfprComputeRackUnitMbTempStatsHistTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.57.1.1 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.57.1.2 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.3 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.4 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.5 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.6 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.7 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:frontTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.8 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.9 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.10 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.11 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:id
managed object property |
CISCO-TCUnsigned64 | .1.3.6.1.4.1.9.9.826.1.12.57.1.12 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1Temp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.13 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.14 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.15 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.16 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2Temp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.17 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.18 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.19 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.20 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:mostRecent
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.57.1.21 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:rearTemp
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.22 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempAvg
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.23 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempMax
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.24 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempMin
managed object property |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.826.1.12.57.1.25 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:suspect
managed object property |
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.826.1.12.57.1.26 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:thresholded
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeRackUnitMbTempStatsHistThresholded Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.57.1.27 |
||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RackUnitMbTempStatsHist:timeCollected
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.57.1.28 |
.1.3.6.1.4.1.9.9.826.1.12.58
·
1 row entry
·
17 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeRtcBatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeRtcBatteryTable'
Cisco Firepower compute:RtcBattery managed object table
Entry for the cfprComputeRtcBatteryTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.58.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.58.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:locationDn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:operState managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:operability
managed object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:perf managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:power managed object property
|
CISCO-FIREPOWER-TC-MIBCfprEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:presence managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:revision managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:serial managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:thermal managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:vendor managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.58.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:RtcBattery:voltage managed
object property |
CISCO-FIREPOWER-TC-MIBCfprEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.58.1.17 |
.1.3.6.1.4.1.9.9.826.1.12.59
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeScrubPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeScrubPolicyTable'
Cisco Firepower compute:ScrubPolicy managed object table
Entry for the cfprComputeScrubPolicyTable table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.59.1.1 |
||||||
|
Cisco Firepower compute:ScrubPolicy:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.59.1.2 |
||||||
|
Cisco Firepower compute:ScrubPolicy:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.59.1.3 |
||||||
|
Cisco Firepower compute:ScrubPolicy:biosSettingsScrub
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeScrubAction Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.59.1.4 |
||||||
|
Cisco Firepower compute:ScrubPolicy:descr managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.59.1.5 |
||||||
|
Cisco Firepower compute:ScrubPolicy:diskScrub
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeScrubAction Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.59.1.6 |
||||||
|
Cisco Firepower compute:ScrubPolicy:flexFlashScrub
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeScrubAction Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.59.1.7 |
||||||
|
Cisco Firepower compute:ScrubPolicy:intId managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.59.1.8 |
||||||
|
Cisco Firepower compute:ScrubPolicy:name managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.59.1.9 |
||||||
|
Cisco Firepower compute:ScrubPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.59.1.10 |
||||||
|
Cisco Firepower compute:ScrubPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.59.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.60
·
1 row entry
·
21 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeServerDiscPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeServerDiscPolicyTable'
Cisco Firepower compute:ServerDiscPolicy managed object table
Entry for the cfprComputeServerDiscPolicyTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.60.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.60.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:action
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmPrev
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmProgr
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvRslt
managed object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.60.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmStageDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmStamp
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.60.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmStatus
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:fsmTry
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.60.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicy:scrubPolicyName
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.60.1.21 |
.1.3.6.1.4.1.9.9.826.1.12.61
·
1 row entry
·
11 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeServerDiscPolicyFsmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeServerDiscPolicyFsmTable'
Cisco Firepower compute:ServerDiscPolicyFsm managed object table
Entry for the cfprComputeServerDiscPolicyFsmTable table.
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.61.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.61.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.61.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:completionTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.61.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:currentFsm
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeServerDiscPolicyFsmCurrentFsm Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.61.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.61.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:fsmStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.61.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:progress
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.61.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:rmtErrCode
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.61.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:rmtErrDescr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.61.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsm:rmtRslt
managed object property |
CISCO-FIREPOWER-TC-MIBCfprConditionRemoteInvRslt Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.61.1.11 |
.1.3.6.1.4.1.9.9.826.1.12.62
·
1 row entry
·
9 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeServerDiscPolicyFsmStageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeServerDiscPolicyFsmStageTable'
Cisco Firepower compute:ServerDiscPolicyFsmStage managed object table
Entry for the cfprComputeServerDiscPolicyFsmStageTable table.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.62.1.1 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.62.1.2 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.62.1.3 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.62.1.4 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:lastUpdateTime
managed object property |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.9.9.826.1.12.62.1.5 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:name
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeServerDiscPolicyFsmStageName Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.62.1.6 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:order
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.62.1.7 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:retry
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.62.1.8 |
||||||||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmStage:stageStatus
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFsmStageStatus Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.62.1.9 |
.1.3.6.1.4.1.9.9.826.1.12.63
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeServerDiscPolicyFsmTaskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeServerDiscPolicyFsmTaskTable'
Cisco Firepower compute:ServerDiscPolicyFsmTask managed object table
Entry for the cfprComputeServerDiscPolicyFsmTaskTable table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.63.1.1 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:dn
managed object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.63.1.2 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:rn
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.63.1.3 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:completion
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmCompletion Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.63.1.4 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:flags
managed object property |
CISCO-FIREPOWER-TC-MIBCfprFsmFlags Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.63.1.5 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:item
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeServerDiscPolicyFsmTaskItem Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.63.1.6 |
||||||||
|
Cisco Firepower compute:ServerDiscPolicyFsmTask:seqId
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.63.1.7 |
.1.3.6.1.4.1.9.9.826.1.12.64
·
1 row entry
·
10 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeServerMgmtPolicyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeServerMgmtPolicyTable'
Cisco Firepower compute:ServerMgmtPolicy managed object table
Entry for the cfprComputeServerMgmtPolicyTable table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.64.1.1 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:dn managed
object property |
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.64.1.2 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:rn managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.3 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:action
managed object property |
CISCO-FIREPOWER-TC-MIBCfprComputeServerMgmtDiscAction Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.64.1.4 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:descr
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.5 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:intId
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.6 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:name
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.7 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:policyLevel
managed object property |
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.8 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:policyOwner
managed object property |
CISCO-FIREPOWER-TC-MIBCfprPolicyPolicyOwner Type Values:
|
.1.3.6.1.4.1.9.9.826.1.12.64.1.9 |
||||||
|
Cisco Firepower compute:ServerMgmtPolicy:qualifier
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.64.1.10 |
cfprComputeSlotQualTable
table.1.3.6.1.4.1.9.9.826.1.12.65
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprComputeSlotQualTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-COMPUTE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-COMPUTE-MIB::cfprComputeSlotQualTable'
Cisco Firepower compute:SlotQual managed object table
Entry for the cfprComputeSlotQualTable table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.12.65.1.1 |
|
Cisco Firepower compute:SlotQual:dn managed object property
|
CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.12.65.1.2 |
|
Cisco Firepower compute:SlotQual:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.826.1.12.65.1.3 |
|
Cisco Firepower compute:SlotQual:maxId managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeSlotQualMaxId Type Constraints: range: 1..8 |
.1.3.6.1.4.1.9.9.826.1.12.65.1.4 |
|
Cisco Firepower compute:SlotQual:minId managed object property
|
CISCO-FIREPOWER-TC-MIBCfprComputeSlotQualMinId Type Constraints: range: 1..8 |
.1.3.6.1.4.1.9.9.826.1.12.65.1.5 |