CISCO-DMN-DSG-DIAG-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
14
.1.3.6.1.4.1.1429.2.2.5.18.2.1 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk diagHealthMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DMN-DSG-DIAG-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DMN-DSG-DIAG-MIB::diagHealthMonitorTable'
Health Monitor Table.
diagHealthMonitorEntry row .1.3.6.1.4.1.1429.2.2.5.18.2.1.1
Entry for Health Monitor table.
Column Syntax OID
Health Monitor index.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.1429.2.2.5.18.2.1.1.1
Health Monitor Item Name -
Gives Board Current temperature if monitor index is CURTEMP
Gives Board Maximum tempearture if monitor index is MAXTEMP
Gives Board Average temperature if monitor index is AVGTEMP
Gives Board …
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.1429.2.2.5.18.2.1.1.2
Health monitor Item Value.
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.1429.2.2.5.18.2.1.1.3
.1.3.6.1.4.1.1429.2.2.5.18.2.2 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk diagFanRPMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DMN-DSG-DIAG-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DMN-DSG-DIAG-MIB::diagFanRPMTable'
Fan RPM Table.
diagFanRPMEntry row .1.3.6.1.4.1.1429.2.2.5.18.2.2.1
Entry for Fan RPM table.
Indexes
Column Syntax OID
Fan RPM index.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1429.2.2.5.18.2.2.1.1
Fan RPM Item Name :
Gives Fan 1 speed in rpm if Fan RPM index is FAN1
Gives Fan 2 speed in rpm if Fan RPM index is FAN2
Gives Fan 3 speed in rpm if Fan RPM index is FAN3
Gives Fan 4 speed in rpm if Fan RPM index is FAN4…
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.1429.2.2.5.18.2.2.1.2
Health monitor Item Value.
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.1429.2.2.5.18.2.2.1.3
.1.3.6.1.4.1.1429.2.2.5.18.2.3 · 1 row entry · 5 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk diagECCReadingsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DMN-DSG-DIAG-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DMN-DSG-DIAG-MIB::diagECCReadingsTable'
ECC Readings Table.
diagECCReadingsEntry row .1.3.6.1.4.1.1429.2.2.5.18.2.3.1
Entry for ECC Readings table.
Column Syntax OID
ECC Readings index.
Integer32
Constraints:
range: 1-15
.1.3.6.1.4.1.1429.2.2.5.18.2.3.1.1
ECC Reading Location.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1429.2.2.5.18.2.3.1.2
ECC Reading Type.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1429.2.2.5.18.2.3.1.3
ECC Reading Value.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1429.2.2.5.18.2.3.1.4
ECC Reading Applicibility for this device.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1429.2.2.5.18.2.3.1.5
.1.3.6.1.4.1.1429.2.2.5.18.2.4 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk diagCtrlHistoryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DMN-DSG-DIAG-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DMN-DSG-DIAG-MIB::diagCtrlHistoryTable'
Control History Table.
diagCtrlHistoryEntry row .1.3.6.1.4.1.1429.2.2.5.18.2.4.1
Entry for Control History table.
Column Syntax OID
Control History Table Index.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1429.2.2.5.18.2.4.1.1
Control History Text.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.1429.2.2.5.18.2.4.1.2
Control History Date and Time.
OctetString
Constraints:
range: 0-30
.1.3.6.1.4.1.1429.2.2.5.18.2.4.1.3