CISCO-DM-MIB
The MIB module for the domain management functionality
defined by the Fibre Channel standards (FC-SW2). For the
purposes of this MIB, 'Domain Manager' is the software
functionality which executes in both the principal switch
and other switches.
- Source file
CISCO-DM-MIB- Last revised
- Identity
ciscoDmMIB- Base OID
1.3.6.1.4.1.9.9.302
Imported Objects
| CISCO-FC-FE-MIB | cffFcFeElementName |
| CISCO-SMI | ciscoMgmt |
| CISCO-ST-TC | DomainId DomainIdOrZero FcAddressId FcNameId FcNameIdOrZero |
| CISCO-VSAN-MIB | notifyVsanIndex vsanIndex |
| IF-MIB | ifIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | RowStatus TEXTUAL-CONVENTION (no object page) TruthValue |
Net-SNMP examples using the cisco MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-DM-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-DM-MIB::ciscoDmMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-DM-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-DM-MIB::ciscoDmMIB'
Objects (71)
Showing 71 of 71 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.9.9.302 |
||
.1.3.6.1.4.1.9.9.302.1 |
||
.1.3.6.1.4.1.9.9.302.1.1 |
||
.1.3.6.1.4.1.9.9.302.1.1.1 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1 |
||
|
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.1 |
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.10 |
||
|
OctetString
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.11 |
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.12 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.13 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.14 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.15 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.16 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.17 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.18 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.19 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.2 |
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.20 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.21 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.22 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.23 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.24 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.25 |
||
|
|
Enumeration
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.26 |
|
|
OctetString
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.27 |
|
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.3 |
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.4 |
||
.1.3.6.1.4.1.9.9.302.1.1.1.1.5 |
||
|
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.6 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.7 |
|
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.8 |
|
.1.3.6.1.4.1.9.9.302.1.1.1.1.9 |
||
.1.3.6.1.4.1.9.9.302.1.1.2 |
||
.1.3.6.1.4.1.9.9.302.1.1.2.1 |
||
|
|
.1.3.6.1.4.1.9.9.302.1.1.2.1.1 |
|
.1.3.6.1.4.1.9.9.302.1.1.2.1.2 |
||
|
|
.1.3.6.1.4.1.9.9.302.1.1.2.1.3 |
|
.1.3.6.1.4.1.9.9.302.1.1.3 |
||
.1.3.6.1.4.1.9.9.302.1.1.4 |
||
.1.3.6.1.4.1.9.9.302.1.1.4.1 |
||
.1.3.6.1.4.1.9.9.302.1.1.4.1.1 |
||
.1.3.6.1.4.1.9.9.302.1.1.4.1.2 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.302.1.1.4.1.3 |
|
.1.3.6.1.4.1.9.9.302.1.1.4.1.4 |
||
|
Enumeration
|
.1.3.6.1.4.1.9.9.302.1.1.4.1.5 |
|
.1.3.6.1.4.1.9.9.302.1.1.4.1.6 |
||
.1.3.6.1.4.1.9.9.302.1.1.5 |
||
.1.3.6.1.4.1.9.9.302.1.1.5.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.9.9.302.1.1.5.1.1 |
|
|
OctetString
|
.1.3.6.1.4.1.9.9.302.1.1.5.1.2 |
|
.1.3.6.1.4.1.9.9.302.1.1.5.1.3 |
||
.1.3.6.1.4.1.9.9.302.1.2 |
||
.1.3.6.1.4.1.9.9.302.1.2.1 |
||
.1.3.6.1.4.1.9.9.302.1.2.1.1 |
||
|
Unsigned32
|
.1.3.6.1.4.1.9.9.302.1.2.1.1.1 |
|
|
OctetString
|
.1.3.6.1.4.1.9.9.302.1.2.1.1.2 |
|
.1.3.6.1.4.1.9.9.302.1.2.2 |
||
.1.3.6.1.4.1.9.9.302.1.2.2.1 |
||
.1.3.6.1.4.1.9.9.302.1.2.2.1.1 |
||
.1.3.6.1.4.1.9.9.302.1.2.2.1.2 |
||
|
Unsigned32
|
.1.3.6.1.4.1.9.9.302.1.2.3 |
|
.1.3.6.1.4.1.9.9.302.1.2.4 |
||
.1.3.6.1.4.1.9.9.302.1.2.4.1 |
||
.1.3.6.1.4.1.9.9.302.1.2.4.1.1 |
||
|
OctetString
|
.1.3.6.1.4.1.9.9.302.1.2.4.1.2 |
|
|
Unsigned32
|
.1.3.6.1.4.1.9.9.302.1.2.4.1.3 |
|
.1.3.6.1.4.1.9.9.302.1.3 |
||
.1.3.6.1.4.1.9.9.302.1.3.0 |
||
.1.3.6.1.4.1.9.9.302.2 |
||
.1.3.6.1.4.1.9.9.302.2.1 |
||
.1.3.6.1.4.1.9.9.302.2.2 |
Dependencies (19) 9 direct · 10 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- CISCO-SMIcisco
- SNMPv2-TCrfc
- CISCO-TCcisco
- IANA-ENTITY-MIBrfc
- SNMPv2-CONFrfc
- SNMP-FRAMEWORK-MIBrfc
- UUID-TC-MIBrfc
- ENTITY-MIBrfc
- IANAifType-MIBrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- CISCO-IF-EXTENSION-MIBcisco
- CISCO-ST-TCcisco
- CISCO-VSAN-MIBcisco
- CISCO-NS-MIBcisco
- INET-ADDRESS-MIBrfc
- CISCO-ZS-MIBcisco
- CISCO-FC-FE-MIBcisco
- CISCO-DM-MIBciscoselected
Type Definitions (4)
| Enumeration |
starting(1)unconfigured(2)principalSwitchSelection(3)domainIdDistribution(4)buildFabricPhase(5)reconfigureFabricPhase(6)stable(7)stableWithNoEports(8)stableWithDomainConfigured(9)noDomains(10)disabled(11)suspended(12)unknown(13) |
|
| Enumeration |
nonPrincipal(1)principalUpstream(2)principalDownsteam(3)isolated(4)down(5)unknown(6) |
|
| Unsigned32 |
range: 1..255 |
|
| Integer32 |
range: 0..255 |
Conformance Groups (9)
Compliance Statements (4)
OID
.1.3.6.1.4.1.9.9.302.2.1.1The compliance statement for entities which
implement the Domain Manager.
implement the Domain Manager.
Required groups
| mandatory | dmGroup | |
| mandatory | dmDatabaseGroup | |
| mandatory | dmAreaGroup | |
| mandatory | dmCacheGroup | |
| mandatory | dmNotificationGroup |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| dmIfRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
OID
.1.3.6.1.4.1.9.9.302.2.1.2The compliance statement for entities which
implement the Domain Manager.
implement the Domain Manager.
Required groups
| mandatory | dmGroupRev1 | |
| mandatory | dmDatabaseGroup | |
| mandatory | dmAreaGroup | |
| mandatory | dmCacheGroup | |
| mandatory | dmNotificationGroup | |
| optional | dmFcIdPersistencyGroup |
This group is manadatory for systems which support FC ID persistency. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| dmIfRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistencyRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistency | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
|
| dmFcIdPurge | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
OID
.1.3.6.1.4.1.9.9.302.2.1.3The compliance statement for entities which
implement the Domain Manager.
implement the Domain Manager.
Required groups
| mandatory | dmGroupRev1 | |
| mandatory | dmDatabaseGroup | |
| mandatory | dmAreaGroup | |
| mandatory | dmCacheGroup | |
| mandatory | dmNotificationGroup | |
| optional | dmFcIdPersistencyGroup |
This group is manadatory for systems which support FC ID persistency. |
| optional | dmDomainIDAllowedGroup |
This group is manadatory for systems which support domain ID list configuration. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| dmIfRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistencyRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistency | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
|
| dmFcIdPurge | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
OID
.1.3.6.1.4.1.9.9.302.2.1.4The compliance statement for entities which
implement the Domain Manager.
implement the Domain Manager.
Required groups
| mandatory | dmGroupRev2 | |
| mandatory | dmDatabaseGroup | |
| mandatory | dmAreaGroup | |
| mandatory | dmCacheGroup | |
| mandatory | dmNotificationGroup | |
| optional | dmFcIdPersistencyGroup |
This group is manadatory for systems which support FC ID persistency. |
| optional | dmDomainIDAllowedGroup |
This group is manadatory for systems which support domain ID list configuration. |
Object refinements
| Object | Access | Syntax | Description |
|---|---|---|---|
| dmIfRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistencyRowStatus | readwrite |
active(1), createAndGo(4), destroy(6)
|
Only values 'createAndGo' 'destroy' and 'active' need to be supported. |
| dmFcIdPersistency | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
|
| dmFcIdPurge | readonly | Only read-only access is needed for systems which does not support FC ID Persistency feature. If they do, read-create access is mandatory. |
Notifications / Traps (3)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.9.9.302.1.3.0.1 |
If a Domain ID is not configured or assigned on a
VSAN, then the switch may isolate E_ports on that VSAN. The conditions are : - If the Domain Manager is enabled on the local switch and its request for a configured static Domain ID is rejected or no other Domain ID is assigned, then the E_ports are isolated. - If the domain manager is not enabled and if a static Domain ID is not configured on the VSAN, then the switch will isolate all of its E_ports on the VSAN. This notification contains the vsanIndex of the VSAN on which the condition happened. |
|
.1.3.6.1.4.1.9.9.302.1.3.0.2 |
This notification indicates that the sending switch
has become the new Principal Switch on a VSAN. This notification is sent soon after its election as the new Principal Switch, i.e., upon expiration of a Principal Switch selection timer which is equal to twice Fabric Stability Timeout value (F_S_TOV). This notification contains the vsanIndex of the VSAN on which the switch became the Principal Switch and the WWN of the switch which became the Principal Switch. |
|
.1.3.6.1.4.1.9.9.302.1.3.0.3 |
This notification is sent whenever a switch sends or
receives a Build Fabric (BF) or a ReConfigure Fabric (RCF) message on a VSAN. A switch can receive or issue a BuildFabric (BF) or a ReConfigureFabric (RCF) message under following conditions: - A new link causes two disjoint fabrics in a VSAN to merge into one fabric. The sent/received message is BF if the Domain ID lists on the disjoint fabric does not overlap and it is RCF if they overlap. - An upsteam principal ISL which connects to Principal switch and other switches in a VSAN fails. BF is issued to see if there is an alternative path to the Principal Switch. If not paths exit, then an RCF is issued. - A switch asks for a different set of Domain IDs than the currently assigned list, the Principal switch would issue an RCF. The notification is not sent if a 'dmNewPrincipalSwitchNotify' notification is sent for the same transition. This notification contains the vsanIndex of the VSAN on which RCF was issued. |