This MIB allows management of redundancy of CPU and switch cards for the Catalyst 8540 switch, and other products with similar implementations. The Catalyst 8540 is an ATM switch. It has 13 (or, in some models, 14) slots, of which 2 slots can hold CPU cards, and 3 (or, in some models, 4) slots can hold switch cards. A switch card is one that contains the ATM switching fabric. Two switch cards are combined to operate in 20Gbps switching mode. For CPU cards, 1+1 redundancy is supported. For switch cards, 2+1 redundancy is supported. |
ciscoMgmt | CISCO-SMI |
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP | SNMPv2-CONF |
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32 | SNMPv2-SMI |
TEXTUAL-CONVENTION, TimeStamp, TruthValue | SNMPv2-TC |
Name | Base Type | Values/Constraints |
---|---|---|
active(1), standby(2), unused(3), notPresent(4) | ||
range: 1..65535 | ||
notPresent(1), ok(2), fault(3) |
![]() | .1.3.6.1.4.1.9.9.105 | |
![]() | .1.3.6.1.4.1.9.9.105.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.1.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.1.1.2 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.1.1.3 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.2 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.3 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.4 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.5 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.6 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.7 | |
![]() | .1.3.6.1.4.1.9.9.105.1.1.8 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.1.1.1 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.1.1.2 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.1.1.3 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.2 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.3 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.4 | |
![]() | .1.3.6.1.4.1.9.9.105.1.2.5 | |
![]() | .1.3.6.1.4.1.9.9.105.2 | |
![]() | .1.3.6.1.4.1.9.9.105.2.0 | |
![]() | .1.3.6.1.4.1.9.9.105.3 | |
![]() | .1.3.6.1.4.1.9.9.105.3.1 | |
![]() | .1.3.6.1.4.1.9.9.105.3.2 |
Name | OID | Description |
---|---|---|
.1.3.6.1.4.1.9.9.105.2.0.1 | This notification is generated when the value of ccrCpuStatus changes for a CPU card. The varbind indicates the current status of the affected card. | |
.1.3.6.1.4.1.9.9.105.2.0.2 | This notification is generated when the value of ccrSwitchStatus changes for a switch card. The varbind indicates the current status of the affected card. | |
.1.3.6.1.4.1.9.9.105.2.0.3 | This notification is generated when the value of ccrSwitchMode changes from active(1) to either standby(2) or unused(3) or notPresent(4). The varbind indicates the current mode of the affected card. |