This MIB allows management of redundancy of CPU and 
switch cards for the Catalyst 8540 switch, and other 
products with similar implementations.
        
The Catalyst 8540 is an ATM switch. It has 13 (or, in
some models, 14) slots, of which 2 slots can hold CPU
cards, and 3 (or, in some models, 4) slots can hold
switch cards. A switch card is one that contains the
ATM switching fabric. Two switch cards are combined 
to operate in 20Gbps switching mode.
For CPU cards, 1+1 redundancy is supported.
For switch cards, 2+1 redundancy is supported.
     | 
ciscoC8500RedundancyMIB1.3.6.1.4.1.9.9.105 | 
| ciscoMgmt | CISCO-SMI | 
| MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP | SNMPv2-CONF | 
| MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32 | SNMPv2-SMI | 
| TEXTUAL-CONVENTION, TimeStamp, TruthValue | SNMPv2-TC | 
| Name | Base Type | Values/Constraints | 
|---|---|---|
| active(1), standby(2), unused(3), notPresent(4) | ||
| range: 1..65535 | ||
| notPresent(1), ok(2), fault(3) | 
![]()  | .1.3.6.1.4.1.9.9.105 | |
![]()  | .1.3.6.1.4.1.9.9.105.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.1.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.1.1.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.1.1.3 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.3 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.4 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.5 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.6 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.7 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.1.8 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.1.1.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.1.1.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.1.1.3 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.3 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.4 | |
![]()  | .1.3.6.1.4.1.9.9.105.1.2.5 | |
![]()  | .1.3.6.1.4.1.9.9.105.2 | |
![]()  | .1.3.6.1.4.1.9.9.105.2.0 | |
![]()  | .1.3.6.1.4.1.9.9.105.3 | |
![]()  | .1.3.6.1.4.1.9.9.105.3.1 | |
![]()  | .1.3.6.1.4.1.9.9.105.3.2 | 
| Name | OID | Description | 
|---|---|---|
| .1.3.6.1.4.1.9.9.105.2.0.1 | This notification is generated when the value of
ccrCpuStatus changes for a CPU card.
          
The varbind indicates the current status of the
affected card. | |
| .1.3.6.1.4.1.9.9.105.2.0.2 | This notification is generated when the value of
ccrSwitchStatus changes for a switch card.
          
The varbind indicates the current status of the
affected card. | |
| .1.3.6.1.4.1.9.9.105.2.0.3 | This notification is generated when the value of ccrSwitchMode changes from active(1) to either standby(2) or unused(3) or notPresent(4). The varbind indicates the current mode of the affected card.  |