CISCO-BSC-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
27

bscPortTable

table
.1.3.6.1.4.1.9.9.36.1.1.1 · 1 row entry · 14 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk bscPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-BSC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-BSC-MIB::bscPortTable'
A list of port (serial interfaces) which have been configured 
to support a BSC BSTUN group.
bscPortEntry row .1.3.6.1.4.1.9.9.36.1.1.1.1
Status and parameter values for a port.
Indexes
Column Syntax OID
The router's DLC role to the attached node.
If the bscPortRole is primary, this implies that
the port is connected to a remote secondary device.
If the role is generic, this indicates that the port
will be running fram…
Enumeration
Enumerated Values:
1primary
2secondary
3contention
4dialContention
5generic
.1.3.6.1.4.1.9.9.36.1.1.1.1.1
The code set used for the line controls.
Enumeration
Enumerated Values:
1ebcdic
2ascii
.1.3.6.1.4.1.9.9.36.1.1.1.1.2
For primary, it is the minimum time to be taken
for a cycle round the active poll table; if this
time has not elapsed when the bottom of the poll
table is reached, then polling will pause until
this timer expires. A…
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.9.9.36.1.1.1.1.3
This parameter is valid for primary only. It is
the number of times the active poll table will
be cycled before a non-responding control unit
will be polled. The default is 3.
Integer32
Constraints:
range: 1-50
.1.3.6.1.4.1.9.9.36.1.1.1.1.4
This parameter is valid for primary only. It is
the time that the primary will wait for a response
to a poll or select. The units are tenths of a second.
The default is 10 (1 second).
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.9.9.36.1.1.1.1.5
This is the number of times that a recovery sequence
will be retried before the connection is considered
to have failed. The default is 5.
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.9.9.36.1.1.1.1.6
Count of frames received from the serial
interface with an unsupported control unit
address. If this value is non-zero it indicates
a problem in the configuration.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.1.1.1.7
Count of soft errors; these are errors
which have been recovered. This includes
CRC errors received, frames which were
retransmitted for any reason (NAK received
or the wrong ACK received), etc. This count
is a measu…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.1.1.1.8
Count of hard errors; these are errors which
have not been recovered after bscPortRecoveryRetries
number of retries, and therefore the connection
has been terminated.
These errors could be caused by a hardware error
i…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.1.1.1.9
Count of protocol violations. This counter is
incremented when an unexpected BSC Data Link Control
character is received from the remote device; that
is, the control character is invalid in the current
state of the lo…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.1.1.1.10
This parameter is valid for interfaces configured secondary
which additionally are running local-acknowledgement. If the
configuration does not match the value will be shown as zero.
It is the time the interface will w…
decisecondsInteger32
Constraints:
range: 30-3000
.1.3.6.1.4.1.9.9.36.1.1.1.1.11
This parameter is valid for primary, local-acknowledgement
interfaces only. It is set to TRUE when the interface is
configured to treat specific polls as general polls.
If the configuration cannot support this value, …
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.36.1.1.1.1.12
This parameter is valid for contention only. It is
the address to be used for this interface when the
remote peer router is being used as a concentrator.
The default is 01.
Integer32
Constraints:
range: 1-254
.1.3.6.1.4.1.9.9.36.1.1.1.1.13
This parameter is valid for dialContention only. It is
the amount of time an interface can be quiescent before
return the interface to the dial-in pool.
The default is 5 seconds.
secondsInteger32
Constraints:
range: 2-30
.1.3.6.1.4.1.9.9.36.1.1.1.1.14
.1.3.6.1.4.1.9.9.36.1.2.1 · 1 row entry · 11 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk bscControlUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-BSC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-BSC-MIB::bscControlUnitTable'
A table containing information about specific 
Control Units.
bscCUEntry row .1.3.6.1.4.1.9.9.36.1.2.1.1
The information regarding a single Control Unit.
Column Syntax OID
This value is the poll address of the
BSC Control Unit. This address must be unique
within a BSTUN Group.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.9.9.36.1.2.1.1.1
State of the BSC Control Unit; when active this indicates that
the remote Control Unit is polling or responding to polls.
Enumeration
Enumerated Values:
1inactive
2active
.1.3.6.1.4.1.9.9.36.1.2.1.1.2
Count of sent bytes (octets).
Includes all control characters.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.3
Count of received bytes (octets).
Includes all control characters.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.4
Count of sent frames (blocks).
Includes all control frames.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.5
Count of received frames (blocks).
Includes all control frames.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.6
Count of sent data frames (blocks).
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.7
Count of received data frames (blocks).
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.8
Count of soft errors; these are errors
which have been recovered. This includes
CRC errors received, frames which were
retransmitted for any reason (NAK received
or the wrong ACK received), etc. This count
is a measu…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.9
Count of hard errors; these are errors which
have not been recovered after bscPortRecoveryRetries
number of retries, and therefore the connection
has been terminated.
These errors could be caused by a hardware error
i…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.10
Count of protocol violations. This counter is
incremented when an unexpected BSC Data Link Control
character is received from the remote device; that
is, the control character is invalid in the current
state of the lo…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.36.1.2.1.1.11
.1.3.6.1.4.1.9.9.36.1.3.1 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk bscExtAddressTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-BSC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-BSC-MIB::bscExtAddressTable'
List of all addresses configured by the bsc
extended-address command. This applies only to interfaces
with an ifType of 'bsc'. The address entries must be
unique per interface.
bscExtAddressEntry row .1.3.6.1.4.1.9.9.36.1.3.1.1
The information regarding a single extended addresses.
Column Syntax OID
The poll address of the station configured by the
bsc extended-address command.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.9.9.36.1.3.1.1.1
The select address of the station configured by the
bsc extended-address command.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.9.9.36.1.3.1.1.2