chkpntTrapNetIfState | .1.3.6.1.4.1.2620.1.2000.1.1 | Interface admin status alert, alerts when svnNetIfState = 0(Interface name provided in trap) |
chkpntTrapNetIfUnplugged | .1.3.6.1.4.1.2620.1.2000.1.2 | Interface unplugged alert, alerts when an interface disappear from svnNetIfTable(Interface name provided in trap) |
chkpntTrapNewConnRate | .1.3.6.1.4.1.2620.1.2000.1.3 | New connection rate alert, alerts when the new connection rate equals\exceeds X (New Connections/Sec) |
chkpntTrapConcurrentConnRate | .1.3.6.1.4.1.2620.1.2000.1.4 | Concurrent connections rate alert, alerts when fwNumConn >= X (Connections/Sec) |
chkpntTrapBytesThroughput | .1.3.6.1.4.1.2620.1.2000.1.5 | Bytes throughput alert, alerts when the throughput equals\exceeds X (Bytes/Sec) |
chkpntTrapAcceptedPacketRate | .1.3.6.1.4.1.2620.1.2000.1.6 | Accepted packet rate alert, alerts when the accepted packet rate equals\exceeds X (Packets/Sec) |
chkpntTrapNetIfOperState | .1.3.6.1.4.1.2620.1.2000.1.7 | Interface operational link status alert, alerts when svnNetIfOperState = 0(Interface name provided in trap) |
chkpntTrapNetIfRXDrop | .1.3.6.1.4.1.2620.1.2000.1.8 | Interface RX drops changed alert, alerts when svnNetIfRXDrop changed |
chkpntDiskSpaceTrap | .1.3.6.1.4.1.2620.1.2000.2.1 | Monitored disk partiton is dangerously full alert, alerts when multiDiskFreeAvailablePercent <= X (filesystem name in trap) |
chkpntRAIDVolumeTrap | .1.3.6.1.4.1.2620.1.2000.2.2 | Monitored RAID volume state, alerts when raidVolumeState = 2(volume ID in trap) |
chkpntRAIDDiskTrap | .1.3.6.1.4.1.2620.1.2000.2.3 | Monitored RAID disk state alert, alerts when raidDiskState is one of [DEGRADED (1), FAILED(2) or UNKNOWN(255)](disk ID and volume ID in trap) |
chkpntRAIDDiskFlagsTrap | .1.3.6.1.4.1.2620.1.2000.2.4 | Monitored RAID disk flag alert, alerts when raidDiskFalgs contains the OUT_OF_SYNC(0x01) or QUIESCED(0x02) flags (disk ID and volume ID in trap) |
chkpntCPUCoreUtilTrap | .1.3.6.1.4.1.2620.1.2000.3.1 | Core utilization alert, alerts when multiProcUsage >= X (core name in trap) |
chkpntCPUCoreInterruptsTrap | .1.3.6.1.4.1.2620.1.2000.3.2 | Core interrupts alert, alerts when multiProcInterrupts >= X (core name in trap) |
chkpntSwapMemoryTrap | .1.3.6.1.4.1.2620.1.2000.4.1 | Swap memory utilization alert, alerts when memActiveVirtual64 exceeds X% of memTotalVirtual64 |
chkpntRealMemoryTrap | .1.3.6.1.4.1.2620.1.2000.4.2 | Real memory utilization alert, alerts when memActiveReal64 exceeds X% of memTotalReal64 |
chkpntTempertureTrap | .1.3.6.1.4.1.2620.1.2000.5.1.1 | Temperture sensor alert (Sensor name provided in trap) |
chkpntFanSpeedTrap | .1.3.6.1.4.1.2620.1.2000.5.2.1 | Fan speed sensor alert (Sensor name provided in trap) |
chkpntVoltageTrap | .1.3.6.1.4.1.2620.1.2000.5.3.1 | Voltage sensor alert (Sensor name provided in trap) |
chkpntClusterMemberStateTrap | .1.3.6.1.4.1.2620.1.2000.6.1 | Cluster member state changed alert, alerts when haState changed (Cluster member identifier provided in trap) |
chkpntClusterBlockStateTrap | .1.3.6.1.4.1.2620.1.2000.6.2 | Cluster block state alert, alert when haBlockState is not equal to OK (Cluster member identifier provided in trap) |
chkpntClusterStateTrap | .1.3.6.1.4.1.2620.1.2000.6.3 | Cluster state alert, alert when haStatCode is not equal to 0 (Cluster member identifier provided in trap) |
chkpntClusterProblemStateTrap | .1.3.6.1.4.1.2620.1.2000.6.4 | Cluster problem status alert, alert when haProblemStatus is not equal to OK |
chkpntClusterInterfaceStateTrap | .1.3.6.1.4.1.2620.1.2000.6.5 | Cluster interface status alert, alerts when haStatus is not equal to Up (Interface name provided in trap) |
chkpntClusterXLFailoverTrap | .1.3.6.1.4.1.2620.1.2000.6.6 | ClusterXL failover alert, alerts when haClusterXLFailover is happened (clusterXL failover counter value provided in trap) |
chkpntTrapLSConnState | .1.3.6.1.4.1.2620.1.2000.7.1 | Problem with connection to log server(Log server name provided in trap) |
chkpntTrapOverallLSConnState | .1.3.6.1.4.1.2620.1.2000.7.2 | Problem with connection to one or more log servers |
chkpntTrapLocalLoggingState | .1.3.6.1.4.1.2620.1.2000.7.3 | Problem with one or more log servers resulted with local logging |
asgChassisStateTrap | .1.3.6.1.4.1.2620.1.2001.1.1 | Critical Alert: Chassis State |
asgBladeStateTrap | .1.3.6.1.4.1.2620.1.2001.1.2 | Critical Alert: Blade State |
asgClusterProblemStateTrap | .1.3.6.1.4.1.2620.1.2001.1.3 | Cluster problem status alert |
asgMonitorStateTrap | .1.3.6.1.4.1.2620.1.2001.1.5 | Monitor state |
asgRouteTrap | .1.3.6.1.4.1.2620.1.2001.10.1 | Route inconsistency |
asgDiagTrap | .1.3.6.1.4.1.2620.1.2001.10.2 | Periodic system diagnostics (asg diag) |
asgPingableHostsTrap | .1.3.6.1.4.1.2620.1.2001.10.3 | Pingable hosts state |
asgMemoryLeakDetectTrap | .1.3.6.1.4.1.2620.1.2001.10.4 | Memory leak detection reached threshold |
asgTrapSynatk | .1.3.6.1.4.1.2620.1.2001.10.5 | SYN Defender activation |
asgLspTrap | .1.3.6.1.4.1.2620.1.2001.10.6 | LSP monitor change port state |
asgTrapNetIfState | .1.3.6.1.4.1.2620.1.2001.2.1 | Interface Status Alert (Interface name provided in trap) |
asgTrapNetAdminState | .1.3.6.1.4.1.2620.1.2001.2.2 | Administrative Status Alert (Interface name provided in trap) |
asgDiskSpaceTrap | .1.3.6.1.4.1.2620.1.2001.3.1 | Monitored disk partiton is dangerously Full Alert (filesystem name in trap) |
asgRAIDVolumeTrap | .1.3.6.1.4.1.2620.1.2001.3.2 | Monitored RAID volume state (volume ID in trap) |
asgRAIDDiskTrap | .1.3.6.1.4.1.2620.1.2001.3.3 | Monitored RAID disk state (disk ID and volume ID in trap) |
asgCPUCoreUtilTrap | .1.3.6.1.4.1.2620.1.2001.4.1 | CPU Core Utilization Alert (Core number provided in trap) |
asgCPUCoreInterruptsTrap | .1.3.6.1.4.1.2620.1.2001.4.2 | CPU Core Interrupts Alert (Core number provided in trap) |
asgSwapMemoryTrap | .1.3.6.1.4.1.2620.1.2001.5.1 | Swap Memory Utilization Alert |
asgRealMemoryTrap | .1.3.6.1.4.1.2620.1.2001.5.2 | Real Memory Utilization Alert |
asgTempertureTrap | .1.3.6.1.4.1.2620.1.2001.7.1.1 | Temperture sensor alert (Sensor name provided in trap) |
asgTempertureSensorStateTrap | .1.3.6.1.4.1.2620.1.2001.7.1.2 | Temperture sensor status alert (Sensor name provided in trap) |
asgFanSpeedTrap | .1.3.6.1.4.1.2620.1.2001.7.2.1 | Fan speed sensor alert (Sensor name provided in trap) |
asgFanSpeedSensorStateTrap | .1.3.6.1.4.1.2620.1.2001.7.2.2 | Fan speed sensor status alert (Sensor name provided in trap) |
asgVoltageTrap | .1.3.6.1.4.1.2620.1.2001.7.3.1 | Voltage sensor alert (Sensor name provided in trap) |
asgVoltageSensorStateTrap | .1.3.6.1.4.1.2620.1.2001.7.3.2 | Voltage sensor status alert (Sensor name provided in trap) |
asgSSMTrap | .1.3.6.1.4.1.2620.1.2001.7.4.1 | Security Switch Module alert (Sensor name provided in trap) |
asgSSMPortTrap | .1.3.6.1.4.1.2620.1.2001.7.4.2 | Security Switch Module port status alert (Sensor name provided in trap) |
asgCMMTrap | .1.3.6.1.4.1.2620.1.2001.7.5.1 | Chassis Management Module alert (Sensor name provided in trap) |
asgTrapConnRate | .1.3.6.1.4.1.2620.1.2001.8.1 | Connection Rate Alert (per blade), in connections/sec |
asgTrapConcurrentConn | .1.3.6.1.4.1.2620.1.2001.8.2 | Concurrent Connections Alert (per blade) |
asgTrapConcurrentConnectionsTotal | .1.3.6.1.4.1.2620.1.2001.8.3 | Concurrent Connections Total Alert (per system) |
asgTrapConnRateTotal | .1.3.6.1.4.1.2620.1.2001.8.4 | Connections Rate Total Alert (per system), in connections/sec |
asgTrapThroughput | .1.3.6.1.4.1.2620.1.2001.8.5 | Throughput Alert (per blade), in bps |
asgTrapThroughputTotal | .1.3.6.1.4.1.2620.1.2001.8.6 | Throughput Total Alert (per system), in bps |
asgTrapPacketRate | .1.3.6.1.4.1.2620.1.2001.8.7 | Packet Rate Alert (per blade), in bps |
asgTrapPacketRateTotal | .1.3.6.1.4.1.2620.1.2001.8.8 | Packet Rate Total Alert (per system), in bps |