.1.3.6.1.4.1.3607.2.30.1.1 · 1 row entry · 11 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalMonTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-OPTICAL-MONITOR-MIB::cOpticalMonTable'
This table provides objects to monitor optical
parameters in a network element. It also provides
objects for setting high and low threshold levels, with
configurable severities, on these monitored parameters.
cOpticalMonEntry row .1.3.6.1.4.1.3607.2.30.1.1.1
An entry in the cOpticalMonTable provides objects to
monitor an optical parameter and set threshold levels
on that parameter, at an optical interface.

Note that the set of monitored optical parameters may v…
Column Syntax OID
cOpticalMonDirectionThis object is an index into the cOpticalMonTable
and indicates the direction monitored for the
optical interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.1.1.1.1
cOpticalMonParameterTypeThis object is an index into the cOpticalMonTable
and specifies the optical parameter that is being monitored,
in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.1.1.1.2
cOpticalParameterValueThis object gives the value measured for the particular
optical parameter specified by the cOpticalMonParameterType
object.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.3
cOpticalParamHighAlarmThreshThis object is used to set a high alarm threshold on the
optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an alarm will be r…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.4
cOpticalParamHighWarning15MinThreshThis object is used to set a high warning 15 minute threshold
on the optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an al…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.5
cOpticalParamHighWarning1DayThreshThis object is used to set a high warning 1 day threshold on
the optical parameter being monitored.

If the measured value of the parameter,is greater than the
value configured in this object, an alarm …
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.6
cOpticalParamLowAlarmThreshThis object is used to set a low alarm threshold on the
optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alarm will be ra…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.7
cOpticalParamLowWarning15MinThreshThis object is used to set a low warning 15 minute threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alar…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.8
cOpticalParamLowWarning1DayThreshThis object is used to set a low warning 1 day threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, an alarm w…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.9
cOpticalParamLowDegradeThreshThis object is used to set a low degrade threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm …
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.10
cOpticalParamHighDegradeThreshThis object is used to set a high degrade threshold
on the optical parameter being monitored.

If the measured value of the parameter,goes lower than the
value configured in this object, a degrade alarm…
OpticalParameterValuer/w
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.1.1.1.11
.1.3.6.1.4.1.3607.2.30.2.1 · 1 row entry · 6 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalPMCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-OPTICAL-MONITOR-MIB::cOpticalPMCurrentTable'
This table stores performance monitoring data for the
various optical parameters, collected over the current
interval.
cOpticalPMCurrentEntry row .1.3.6.1.4.1.3607.2.30.2.1.1
An entry in the cOpticalPMCurrentTable. It contains
performance monitoring data for an optical parameter,
collected over the current interval.

Note that the set of monitored optical parameters may vary
base…
Column Syntax OID
cOpticalPMCurrentDirectionThis object is an index into the cOpticalPMCurrentTable
and indicates the direction monitored
for the optical interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.2.1.1.1
cOpticalPMCurrentParamTypeThis object is an index into the
cOpticalPMCurrentTable and specifies the optical parameter
that is being monitored, in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.2.1.1.2
cOpticalPMCurrentPeriodThis object is an index into the
cOpticalPMCurrentTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours.
CERENT-TCCerentPeriod
Type Values:
1unknown
5minutes1
10minutes15
20hour1
30day1
.1.3.6.1.4.1.3607.2.30.2.1.1.3
cOpticalPMCurrentMaxParamThis object gives the maximum value measured for the optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.4
cOpticalPMCurrentMinParamThis object gives the minimum value measured for the optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.5
cOpticalPMCurrentMeanParamThis object gives the average value of the measured optical
parameter, in the current 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.1.1.6
.1.3.6.1.4.1.3607.2.30.2.2 · 1 row entry · 8 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cOpticalPMIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-OPTICAL-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-OPTICAL-MONITOR-MIB::cOpticalPMIntervalTable'
This table stores performance monitoring data for the
various optical parameters, collected over current and 
previous intervals.
          
This table can have entries for up to 96 complete 15 minute  
intervals.
cOpticalPMIntervalEntry row .1.3.6.1.4.1.3607.2.30.2.2.1
An entry in the cOpticalPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over current and previous intervals.

Note that the set of monitored optical parameters ma…
Column Syntax OID
cOpticalPMIntervalDirectionThis object is an index into the cOpticalPMIntervalTable
and indicates the direction monitored
for the optical interface, in this entry.
OpticalIfDirection
Type Values:
1receive
2transmit
3notApplicable
.1.3.6.1.4.1.3607.2.30.2.2.1.1
cOpticalPMIntervalParamTypeThis object is an index into the
cOpticalPMIntervalTable and specifies the optical parameter
that is being monitored, in this entry.
OpticalParameterType
Type Values:
1power
2acPower
3apdTemp
4laserTemp
5biasCurrent
6peltierCurrent
7xcvrVoltage
8voa
9gain
10oscPower
11addPower
.1.3.6.1.4.1.3607.2.30.2.2.1.2
cOpticalPMIntervalPeriodThis object is an index into the
cOpticalPMIntervalTable and indicates whether the
optical parameter values given in this entry, are collected
over a period of 15 minutes or 24 hours.
CERENT-TCCerentPeriod
Type Values:
1unknown
5minutes1
10minutes15
20hour1
30day1
.1.3.6.1.4.1.3607.2.30.2.2.1.3
cOpticalPMIntervalNumberThis object is an index into the cOpticalPMIntervalTable.
It is a number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the m…
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3607.2.30.2.2.1.4
cOpticalPMIntervalMaxParamThis object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.5
cOpticalPMIntervalMinParamThis object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.6
cOpticalPMIntervalMeanParamThis object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
OpticalParameterValue
Type Constraints:
range: -1000000..1000000
.1.3.6.1.4.1.3607.2.30.2.2.1.7
cOpticalPMIntervalValidDataThis variable indicates if the data for this
interval is valid.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3607.2.30.2.2.1.8