CERENT-ENVMON-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
11
.1.3.6.1.4.1.3607.2.80.10
·
1 row entry
·
7 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cerentEnvMonVoltageStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-ENVMON-MIB::cerentEnvMonVoltageStatsTable'
This table maintains the status info for all EnvMon related voltages picked up by the sensors in the device.
There will as many rows as there are sensors
in the device.
in the device.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The value index uniquely indicates the voltage
sensor in the device. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.10 |
|
Unique Name/Description of the voltage
sensor. |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3607.2.80.10.1.20 |
|
Current voltage measurement at this
voltage sensor. |
millivoltsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.30 |
|
If the current voltage value exceeds this
threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
millivoltsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.40 |
|
If the current voltage value exceeds this
threshold value, a warning event will be raised by the device. The severity of this event may be provisionable. |
millivoltsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.50 |
|
If the current voltage value falls below this
threshold value, a warning event will be raised by the device. The severity of this event may be provisionable. |
millivoltsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.60 |
|
If the current voltage value falls below this
threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
millivoltsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.3607.2.80.10.1.70 |
.1.3.6.1.4.1.3607.2.80.20
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cerentEnvMonTemperatureStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-ENVMON-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-ENVMON-MIB::cerentEnvMonTemperatureStatsTable'
This table provides ambient temperature information as measured by the temperature sensors.
Each temperature is represented by a row
in the table.
in the table.
| Column | Syntax | OID |
|---|---|---|
|
The value index uniquely indicates the
temperature sensor in the device. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.3607.2.80.20.1.10 |
|
Unique Name/Description of the
temperature sensor. |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.3607.2.80.20.1.20 |
|
Current Temperature measurement at this
temperature sensor. |
Degree CelsiusSNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3607.2.80.20.1.30 |
|
If the current temperature value exceeds this
threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable. |
Degree CelsiusSNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3607.2.80.20.1.40 |