CERENT-454-MIB

        This module provides the definitions for
objects for managing Cisco OTBU ONS 15454.
    
Source file
CERENT-454-MIB
Last revised
Identity
cerent454MibModule
Base OID
1.3.6.1.4.1.3607.1.10.20
Imported Objects
CERENT-GLOBAL-REGISTRY cerentModules cerentProducts
CERENT-TC CerentAlarmServiceAffecting CerentAlarmSeverity CerentAlarmStatus CerentLocation CerentMonitorType CerentNotificationClass CerentPeriod CerentPortNumber
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI Counter32 Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) Unsigned32
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page) TimeStamp TruthValue
Net-SNMP examples using the cisco MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'CERENT-454-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CERENT-454-MIB::cerent454MibModule'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CERENT-454-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CERENT-454-MIB::cerent454MibModule'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (61)
.1.3.6.1.4.1.3607.1.10.20
.1.3.6.1.4.1.3607.6.10
.1.3.6.1.4.1.3607.6.10.10
.1.3.6.1.4.1.3607.6.10.10.10
.1.3.6.1.4.1.3607.6.10.10.20
.1.3.6.1.4.1.3607.6.10.100
.1.3.6.1.4.1.3607.6.10.100.10
.1.3.6.1.4.1.3607.6.10.100.10.10
.1.3.6.1.4.1.3607.6.10.100.10.20
.1.3.6.1.4.1.3607.6.10.100.10.30
.1.3.6.1.4.1.3607.6.10.100.10.40
.1.3.6.1.4.1.3607.6.10.100.10.50
.1.3.6.1.4.1.3607.6.10.20
.1.3.6.1.4.1.3607.6.10.20.20
.1.3.6.1.4.1.3607.6.10.20.20.10
.1.3.6.1.4.1.3607.6.10.20.30
.1.3.6.1.4.1.3607.6.10.20.30.10
.1.3.6.1.4.1.3607.6.10.20.30.20
.1.3.6.1.4.1.3607.6.10.20.30.20.1
Integer32
.1.3.6.1.4.1.3607.6.10.20.30.20.1.10
.1.3.6.1.4.1.3607.6.10.20.30.20.1.100
.1.3.6.1.4.1.3607.6.10.20.30.20.1.110
.1.3.6.1.4.1.3607.6.10.20.30.20.1.120
.1.3.6.1.4.1.3607.6.10.20.30.20.1.130
.1.3.6.1.4.1.3607.6.10.20.30.20.1.140
.1.3.6.1.4.1.3607.6.10.20.30.20.1.20
.1.3.6.1.4.1.3607.6.10.20.30.20.1.30
.1.3.6.1.4.1.3607.6.10.20.30.20.1.40
.1.3.6.1.4.1.3607.6.10.20.30.20.1.50
.1.3.6.1.4.1.3607.6.10.20.30.20.1.60
.1.3.6.1.4.1.3607.6.10.20.30.20.1.70
.1.3.6.1.4.1.3607.6.10.20.30.20.1.80
.1.3.6.1.4.1.3607.6.10.20.30.20.1.90
.1.3.6.1.4.1.3607.6.10.20.30.30
.1.3.6.1.4.1.3607.6.10.20.30.40
.1.3.6.1.4.1.3607.6.10.20.30.40.1
Integer32
.1.3.6.1.4.1.3607.6.10.20.30.40.1.10
.1.3.6.1.4.1.3607.6.10.20.30.40.1.100
.1.3.6.1.4.1.3607.6.10.20.30.40.1.110
.1.3.6.1.4.1.3607.6.10.20.30.40.1.120
.1.3.6.1.4.1.3607.6.10.20.30.40.1.20
.1.3.6.1.4.1.3607.6.10.20.30.40.1.30
.1.3.6.1.4.1.3607.6.10.20.30.40.1.40
.1.3.6.1.4.1.3607.6.10.20.30.40.1.50
.1.3.6.1.4.1.3607.6.10.20.30.40.1.60
.1.3.6.1.4.1.3607.6.10.20.30.40.1.70
.1.3.6.1.4.1.3607.6.10.20.30.40.1.80
.1.3.6.1.4.1.3607.6.10.20.30.40.1.90
.1.3.6.1.4.1.3607.6.10.20.40
.1.3.6.1.4.1.3607.6.10.20.40.10
.1.3.6.1.4.1.3607.6.10.20.40.10.1
Integer32
.1.3.6.1.4.1.3607.6.10.20.40.10.1.10
.1.3.6.1.4.1.3607.6.10.20.40.10.1.20
.1.3.6.1.4.1.3607.6.10.20.40.10.1.30
.1.3.6.1.4.1.3607.6.10.20.40.10.1.40
.1.3.6.1.4.1.3607.6.10.20.40.10.1.50
.1.3.6.1.4.1.3607.6.10.20.40.10.1.60
Enumeration
.1.3.6.1.4.1.3607.6.10.20.40.10.1.70
.1.3.6.1.4.1.3607.6.10.200
.1.3.6.1.4.1.3607.6.10.30
.1.3.6.1.4.1.3607.6.10.30.0
Dependencies (5) 5 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. CERENT-GLOBAL-REGISTRYcisco
  3. SNMPv2-CONFrfc
  4. SNMPv2-TCrfc
  5. CERENT-TCcisco
  6. CERENT-454-MIBciscoselected
Type Definitions (2)
Enumeration
alarmUnknown(1)
alarmCutoffIsInManualMode(10)
failureDetectedExternalToTheNE(20)
externalError(30)
excessiveSwitching(40)
sdccTerminationFailure(50)
incomingFailureCondition(60)
alarmIndicationSignal(70)
alarmIndicationSignalLine(80)
alarmIndicationSignalPath(90)
alarmIndicationSignalVT(100)
apsChannelFailure(110)
channelByteFailureAPS(120)
channelProtectionSwitchingChannelMatchFailureAPS(130)
channelAutomaticProtectionSwitchModeMismatchAPS(140)
farEndProtectionLineFailure(150)
inconsistentAPSCode(160)
improperAPSCode(170)
nodeIdMismatch(180)
channelDefaultKAPS(190)
connectionLoss(200)
bipolarViolation(210)
carrierLossOnTheLAN(220)
concatenationErrorSTS(230)
excessCollisionsOnTheLAN(240)
facilityFailure(250)
farEndAIS(260)
farEndMultipleDS1LOSDetectedOnDS3(270)
farEndDS1EqptFailNonServiceAffecting(280)
farEndDS1EqptFailServiceAffecting(290)
farEndSingleDS1LOS(300)
farEndDS3EqptFailNonServiceAffecting(310)
farEndDS3EqptFailServiceAffecting(320)
farEndCommonEquipmentFailureNonServiceAffecting(330)
farEndIDLE(340)
farEndLOS(350)
farEndLOF(360)
farEndBlockError(370)
ds3IdleCondition(380)
lossOfFrame(390)
lossOfPointer(400)
lossOfPointerPath(410)
lossOfPointerVT(420)
lossOfSignal(430)
outOfFrame(440)
pathSelectorFailure(450)
remoteAlarmIndication(460)
remoteFailureIndication(470)
remoteFailureIndicationLine(480)
remoteFailureIndicationPath(490)
remoteFailureIndicationVT(500)
signalDegrade(510)
severelyErroredFrame(520)
signalFailure(530)
signalLabelMismatchFailure(540)
payloadDefectIndication(550)
payloadDefectIndicationPath(560)
payloadLabelMismatchPath(570)
signalLabelMismatchFailurePayloadLabelMismatchVT(580)
unequippedPath(590)
signalLabelMismatchFailureUnequippedVT(600)
lossOfSynchronization(610)
outOfSynchronization(620)
primarySynchronizationReferenceFailure(630)
secondarySynchronizationReferenceFailure(640)
thirdSynchronizationReferenceFailure(650)
fourthSynchronizationReferenceFailure(660)
fifthSynchronizationReferenceFailure(670)
sixthSynchronizationReferenceFailure(680)
failedToReceiveSynchronizationStatusMessage(690)
synchronizationStatusMessagesAreDisabledOnThisInterface(700)
stratum1PrimaryReferenceSourceTraceable(710)
synchronizedTraceabilityUnknown(720)
stratum2Traceable(730)
transitNodeClockTraceable(740)
stratum3ETraceable(750)
stratum3Traceable(760)
sonetMinimumClockTraceable(770)
stratum4Traceable(780)
doNotUseForSynchronization(790)
reservedForNetworkSynchronizationUse(800)
outgoingFailureCondition(810)
remoteDefectIndicationLine(820)
remoteDefectIndicationPath(830)
freeRunningSynchronizationMode(840)
holdoverSynchronizationMode(850)
fastStartSynchronizationMode(860)
internalFault(870)
internalError(880)
internalMessageError(890)
mismatchOfEquipmentAndAttributes(900)
watchdogTimerTimeout(910)
softwareFaultOrFailure(920)
softwareFaultDataIntegrityFault(930)
programFailure(940)
controlEquipmentFailure(950)
primaryNonVolatileBackupMemoryFailure(960)
secondaryNonVolatileBackupMemoryFailure(970)
controlBusFailure(980)
controlBus1Failure(990)
controlBus2Failure(1000)
tccAToShelfSlot1DROP1CommunicationFailure(1010)
tccAToShelfSlot2DROP2CommunicationFailure(1020)
tccAToShelfSlot3DROP3CommunicationFailure(1030)
tccAToShelfSlot4DROP4CommunicationFailure(1040)
tccAToShelfSlot5TRUNK1CommunicationFailure(1050)
tccAToShelfSlot6TRUNK2CommunicationFailure(1060)
tccAToShelfSlot7TCCACommunicationFailure(1070)
tccAToShelfSlot8XCONACommunicationFailure(1080)
tccAToShelfSlot9AICCommunicationFailure(1090)
tccAToShelfSlot10XCONBCommunicationFailure(1100)
tccAToShelfSlot11TCCBCommunicationFailure(1110)
tccAToShelfSlot12TRUNK3CommunicationFailure(1120)
tccAToShelfSlot13TRUNK4CommunicationFailure(1130)
tccAToShelfSlot14DROP5CommunicationFailure(1140)
tccAToShelfSlot15DROP6CommunicationFailure(1150)
tccAToShelfSlot16DROP7CommunicationFailure(1160)
tccAToShelfSlot17DROP8CommunicationFailure(1170)
tccAToDCCAProcessorCommunicationFailure(1180)
tccBToShelfSlot1DROP1CommunicationFailure(1190)
tccBToShelfSlot2DROP2CommunicationFailure(1200)
tccBToShelfSlot3DROP3CommunicationFailure(1210)
tccBToShelfSlot4DROP4CommunicationFailure(1220)
tccBToShelfSlot5TRUNK1CommunicationFailure(1230)
tccBToShelfSlot6TRUNK2CommunicationFailure(1240)
tccBToShelfSlot7TCCACommunicationFailure(1250)
tccBToShelfSlot8XCONACommunicationFailure(1260)
tccBToShelfSlot9AICCommunicationFailure(1270)
tccBToShelfSlot10XCONBCommunicationFailure(1280)
tccBToShelfSlot11TCCBCommunicationFailure(1290)
tccBToShelfSlot12TRUNK3CommunicationFailure(1300)
tccBToShelfSlot13TRUNK4CommunicationFailure(1310)
tccBToShelfSlot14DROP5CommunicationFailure(1320)
tccBToShelfSlot15DROP6CommunicationFailure(1330)
tccBToShelfSlot16DROP7CommunicationFailure(1340)
tccBToShelfSlot17DROP8CommunicationFailure(1350)
tccBToDCCBProcessorCommunicationFailure(1360)
controlEquipmentControlCommunicationsEquipmentFailure(1370)
controlProcessorFailure(1380)
workingMemoryFailure(1390)
interconnectionEquipmentFailure(1400)
payloadBusFailureToIOSlot1XCONSlot8(1410)
payloadBusFailureToIOSlot2XCONSlot8(1420)
payloadBusFailureToIOSlot3XCONSlot8(1430)
payloadBusFailureToIOSlot4XCONSlot8(1440)
payloadBusFailureToIOSlot5XCONSlot8(1450)
payloadBusFailureToIOSlot6XCONSlot8(1460)
payloadBusFailureToIOSlot12XCONSlot8(1470)
payloadBusFailureToIOSlot13XCONSlot8(1480)
payloadBusFailureToIOSlot14XCONSlot8(1490)
payloadBusFailureToIOSlot15XCONSlot8(1500)
payloadBusFailureToIOSlot16XCONSlot8(1510)
payloadBusFailureToIOSlot17XCONSlot8(1520)
payloadBusFailureToIOSlot1XCONSlot10(1530)
payloadBusFailureToIOSlot2XCONSlot10(1540)
payloadBusFailureToIOSlot3XCONSlot10(1550)
payloadBusFailureToIOSlot4XCONSlot10(1560)
payloadBusFailureToIOSlot5XCONSlot10(1570)
payloadBusFailureToIOSlot6XCONSlot10(1580)
payloadBusFailureToIOSlot12XCONSlot10(1590)
payloadBusFailureToIOSlot13XCONSlot10(1600)
payloadBusFailureToIOSlot14XCONSlot10(1610)
payloadBusFailureToIOSlot15XCONSlot10(1620)
payloadBusFailureToIOSlot16XCONSlot10(1630)
payloadBusFailureToIOSlot17XCONSlot10(1640)
timeSlotInterchangeEquipmentFailure(1650)
equipmentFailure(1660)
highTemperature(1670)
invalidMACAddress(1680)
boardFailure(1690)
diagnosticFailure(1700)
mediumAccessControlFailure(1710)
facilityTerminationEquipmentFailure(1720)
automaticLaserShutoffDueToHighTemperature(1730)
failureToReleaseFromProtection(1740)
receiverFailure(1750)
transmitFailure(1760)
facilityTerminationEquipmentReceiverMissing(1770)
facilityTerminationEquipmentTransmitterMissing(1780)
failureToSwitchToProtection(1790)
failureToSwitchToProtectionRing(1800)
failureToSwitchToProtectionSpan(1810)
failureToSwitchToProtectionPath(1820)
fanFailure(1830)
equipmentUnitPlugIn(1840)
nePowerFailureAtConnector(1850)
fuseAlarm(1860)
synchronizationUnitFailure(1870)
synchronizationSwitchingEquipmentFailure(1880)
equipmentUnitUnplugged(1890)
loopback(1900)
ds1LoopbackDueToFEACCommand(1910)
loopbackCommandSentToFarEndDS1(1920)
ds3LoopbackDueToFEACCommand(1930)
ds3LoopbackCommandSentToFarEnd(1940)
ds2LoopbackDueToFarEndCommand(1950)
ds2LoopbackCommandSentToFarEnd(1960)
facilityLoopback(1970)
networkLoopback(1980)
terminalLoopback(1990)
manuallyCausedAbnormalCondition(2000)
ethernetBridgeIsNewRootOfSpanningTree(2010)
ethernetBridgeTopologyChange(2020)
normalCondition(2030)
embeddedOperationsChannelFailureLinkDown(2040)
peerStateMismatch(2050)
proceduralError(2060)
improperRemoval(2070)
duplicateNodeID(2080)
blsrOutOfSync(2090)
blsrMultiNodeTableUpdateCompleted(2100)
protectionUnitNotAvailable(2110)
performanceMonitorThresholdCrossingAlert(2120)
protectionSwitch(2130)
recoveryOrServiceProtectionActionHasBeenInitiated(2140)
automaticSystemReset(2150)
automaticUPSRSwitchCausedByAIS(2160)
automaticUPSRSwitchCausedByLOP(2170)
automaticUPSRSwitchCausedByUNEQ(2180)
automaticUPSRSwitchCausedByPDI(2190)
automaticUPSRSwitchCausedBySFBER(2200)
automaticUPSRSwitchCausedBySDBER(2210)
coldRestart(2220)
forcedSwitchBackToWorking(2230)
forcedSwitchBackToWorkingRing(2240)
forcedSwitchBackToWorkingSpan(2250)
forcedSwitchToProtection(2260)
forcedSwitchToProtectionRing(2270)
forcedSwitchToProtectionSpan(2280)
workingFacilityOrEquipmentForcedToSwitchToProtectionPath(2290)
initializationInitiated(2300)
lockoutOfProtection(2310)
lockoutOfProtectionRing(2320)
lockoutOfProtectionSpan(2330)
lockoutOfProtectionPath(2340)
lockoutOfWorking(2350)
lockoutOfWorkingRing(2360)
lockoutOfWorkingSpan(2370)
manualSystemReset(2380)
manualSwitchToInternalClock(2390)
manualSwitchToPrimaryReference(2400)
manualSwitchToSecondReference(2410)
manualSwitchToThirdReference(2420)
manualSwitchToFourthReference(2430)
manualSwitchToFifthReference(2440)
manualSwitchToSixthReference(2450)
manualSwitchBackToWorking(2460)
manualSwitchBackToWorkingRing(2470)
manualSwitchBackToWorkingSpan(2480)
manualSwitchToProtection(2490)
manualSwitchToProtectionRing(2500)
manualSwitchToProtectionSpan(2510)
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath(2520)
powerfailRestart(2530)
ringIsSquelchingTraffic(2540)
softwareDownloadInProgress(2550)
switchToInternalClock(2560)
switchToPrimaryReference(2570)
switchToSecondReference(2580)
switchToThirdReference(2590)
switchToFourthReference(2600)
switchToFifthReference(2610)
switchToSixthReference(2620)
systemReboot(2630)
switchedBackToWorking(2640)
switchedToProtection(2650)
warmRestart(2660)
ringIsInWaitToRestoreState(2670)
manualSwitchRequest(2680)
forcedSwitchRequest(2690)
lockoutSwitchRequest(2700)
rmonHistoriesAndAlarmsResetReboot(2710)
rmonThresholdCrossingAlarm(2720)
alarmsSuppressedByUserCommand(2730)
alarmsSuppressedForMaintenance(2740)
switchingMatrixModuleFailure(2750)
lanConnectionPolarityReversed(2760)
autonomousPMReportMessageInhibited(2780)
ioSlotToXCONCommunicationFailure(2790)
stsPathTraceIdentifierMismatch(2800)
nePowerFailureAtConnectorA(2810)
nePowerFailureAtConnectorB(2820)
freeMemoryOnCardVeryLow(2830)
freeMemoryOnCardNearZero(2840)
exerciseRequestOnRing(2850)
exerciseRequestOnSpan(2860)
squelchingPath(2870)
extraTrafficPreempted(2880)
farEndLockoutOfWorkingRing(2890)
farEndLockoutOfWorkingSpan(2900)
farEndLockoutOfProtectionRing(2910)
farEndLockoutOfProtectionAllSpans(2920)
farEndWorkingFacilityForcedToSwitchToProtectionRing(2930)
farEndWorkingFacilityForcedToSwitchToProtectionSpan(2940)
farEndManualSwitchOfWorkingFacilityToProtectionRing(2950)
farEndManualSwitchOfWorkingFacilityToProtectionSpan(2960)
farEndExercisingRing(2970)
farEndExercisingSpan(2980)
farEndBERThresholdPassedForSignalFailureRing(2990)
farEndBERThresholdPassedForSignalFailureSpan(3000)
farEndBERThresholdPassedForSignalDegradeRing(3010)
farEndBERThresholdPassedForSignalDegradeSpan(3020)
apsChannelFarEndProtectionLineSignalDegrade(3030)
ringSwitchIsActiveOnTheEastSide(3040)
ringSwitchIsActiveOnTheWestSide(3050)
spanSwitchIsActiveOnTheEastSide(3060)
spanSwitchIsActiveOnTheWestSide(3070)
uniDirectionalFullPassThroughIsActive(3080)
biDirectionalFullPassThroughIsActive(3090)
kBytesPassThroughIsActive(3100)
ringIsSegmented(3110)
ringTopologyIsUnderConstruction(3120)
lockoutOfProtectionAllSpans(3130)
farEndOfFiberIsProvisionedWithDifferentRingID(3140)
bothEndsOfFiberProvisionedAsEastOrBothAsWest(3150)
securityInvalidLoginUsernameSeeAuditTrail(3160)
autonomousMessagesInhibited(3170)
trafficStormOnLANLANTemporarilyDisabled(3180)
reptdbchgMessagesInhibited(3190)
securityUserIDHasExpired(3200)
partialFanFailure(3210)
forcedSwitchRequestOnRing(3220)
forcedSwitchRequestOnSpan(3230)
lockoutSwitchRequestOnRing(3240)
lockoutSwitchRequestOnSpan(3250)
manualSwitchRequestOnRing(3260)
manualSwitchRequestOnSpan(3270)
communicationFailurePeerToPeerSlotControlBusA(3280)
communicationFailurePeerToPeerSlotControlBusB(3290)
controllerAToShelfSlotCommunicationFailure(3300)
controllerBToShelfSlotCommunicationFailure(3310)
interconnectionEquipmentFailureWorkingPayloadBus(3320)
interconnectionEquipmentFailureProtectPayloadBus(3330)
inhibitSwitchToProtectRequestOnEquipment(3340)
inhibitSwitchToWorkingRequestOnEquipment(3350)
berThresholdExceededForSignalDegradeLine(3360)
berThresholdExceededForSignalDegradePath(3370)
berThresholdExceededForSignalFailureLine(3380)
berThresholdExceededForSignalFailurePath(3390)
exercisingRingSuccessfully(3400)
exercisingSpanSuccessfully(3410)
spanIsInWaitToRestoreState(3420)
exerciseRequestOnRingFailed(3430)
exerciseRequestOnSpanFailed(3440)
farEndLockoutOfProtectionSpan(3450)
manufacturingDataMemoryEEPROMFailure(3460)
replaceableEquipmentOrUnitIsMissing(3470)
softwareDownloadFailed(3480)
extraTrafficPCADropped(3490)
etherTxOversubscribed(3500)
etherRxOverSubscribed(3510)
etherTxExcessFlowCtrl(3520)
etherRxExcessFlowCtrl(3530)
transportLayerFailure(3540)
etherTxUnderrun(3550)
synchronizationReferenceFrequencyOutOfBounds(3560)
ntpOrSntpHostFailure(3570)
peerCardNotResponding(3580)
alarmsAndEventsSuppressedForThisObject(3590)
ds3FrameFormatMismatch(3600)
waitToRestore(3610)
extremeHighVoltBatteryA(3620)
extremeLowVoltBatteryA(3630)
extremeHighVoltBatteryB(3640)
extremeLowVoltBatteryB(3650)
iosConfigCopyFailed(3660)
iosConfigCopyInProgress(3670)
iosConfigCopySuccess(3680)
signalingUnableToSetupCircuit(3710)
errorInStartupConfig(3712)
noStartupConfig(3714)
needToSaveRunningConfig(3716)
invalidAlarm(3718)
rsvpHelloFSMToNeighborDown(3720)
securityInvalidLoginUsername(3722)
databaseBackupFailed(3724)
databaseRestoreFailed(3726)
lmpHelloFSMToControlChannelDown(3730)
lmpNeighborDiscoveryHasFailed(3740)
unauthorizedIncomingSignalingRequest(3750)
auditLog80PercentFull(3760)
moduleCommunicationFailure(3762)
auditLog100PercentFullOldestRecordsWillBeLost(3764)
standbyDatabaseOutOfSync(3766)
redundantPowerCapabilityLost(3768)
forcedSwitchToPrimaryReference(3770)
forcedSwitchToSecondReference(3780)
forcedSwitchToThirdReference(3790)
forcedSwitchToInternalClock(3800)
industrialHighTemperature(3805)
timSectionTraceIdentifierMismatchFailure(4000)
aisMultiplexSectionAlarmIndicationSignal(4010)
rdiMultiplexSectionRemoteDefectOrAlarmIndication(4020)
timHighOrderTraceIdentifierMismatchFailure(4030)
aisAdministrationUnitAlarmIndicationSignal(4040)
lopAdministrationUnitLossOfPointer(4050)
slmfUnequippedHighOrderPathUnequipped(4060)
slmfPLMHighOrderPathLabelMismatch(4070)
rdiHighOrderRemoteDefectOrAlarmIndication(4080)
lopTributaryUnitLossOfPointer(4090)
aisTributaryUnitAlarmIndicationSignal(4100)
slmfUnequippedLowOrderPathUnequipped(4110)
slmfPLMLowOrderPathLabelMismatch(4120)
timLowOrderTraceIdentifierMismatchFailure(4130)
rfiLowOrderRemoteFailureOrAlarmIndication(4140)
g811PrimaryReferenceClockTraceable(4150)
g812TransitNodeClockTraceable(4160)
g812LocalNodeClockTraceable(4170)
g813SynchronousEquipmentTimingSourceTraceable(4180)
e1LoopbackDueToFEACCommand(4190)
e1LoopbackCommandSentToFarEnd(4200)
e3LoopbackDueToFEACCommand(4210)
farEndMultipleE1LOSDetectedOnE3(4220)
farEndE1EqptFailNonServiceAffecting(4230)
farEndE1EqptFailServiceAffecting(4240)
farEndSingleE1LOS(4250)
farEndE3EqptFailServiceAffecting(4260)
e3LoopbackCommandSentToFarEnd(4270)
farEndE3EqptFailNonServiceAffecting(4280)
lowVoltBatteryA(4290)
highVoltBatteryA(4300)
lowVoltBatteryB(4310)
highVoltBatteryB(4320)
msspRingOutOfSync(4330)
msspMultiNodeTableUpdateCompleted(4340)
automaticSNCPSwitchCausedByAIS(4350)
automaticSNCPSwitchCausedByLOP(4360)
automaticSNCPSwitchCausedByUNEQ(4370)
automaticSNCPSwitchCausedByPDI(4380)
automaticSNCPSwitchCausedBySFBER(4390)
automaticSNCPSwitchCausedBySDBER(4400)
stmConcatenationError(4410)
e3IdleCondition(4420)
channelMSSPInconsistentAPSCode(4430)
channelMSSPImproperAPSCodeAPS(4440)
channelMSSPNodeIdMismatchAPS(4450)
channelMSSPDefaultKAPS(4460)
channelMSSPConnectionLossAPS(4470)
minimumClockTraceableSDH(4480)
lineIsInWaitToRestoreStateSDH(4490)
berThresholdExceededForSignalDegradeHighOrder(4500)
berThresholdExceededForSignalFailureHighOrder(4510)
berThresholdExceededForSignalDegradeLowOrder(4520)
berThresholdExceededForSignalFailureLowOrder(4530)
failureToSwitchToProtectionHighOrderPath(4540)
failureToSwitchToProtectionLowOrderPath(4550)
lofAdministrationUnitLossOfMultiFrame(4560)
sdhSpanIsInWaitToRestoreState(4570)
a8b10bOutOfSync(4755)
odukPMAlarmIndicationSignal(4760)
otukAlarmIndicationSignal(4765)
otukSMBackwardDefectIndication(4770)
fecUncorrectedWord(4780)
gccTerminationFailure(4785)
otukIncomingAlignmentError(4790)
odukLockedDefectPM(4795)
lossOfMultiFrame(4800)
odukOpenConnectionIndication(4805)
payloadTypeIdentifierMismatch(4810)
odukTrailTraceIdentifierMismatch(4815)
otukTrailTraceIdentifierMismatch(4820)
equipmentHighLaserBias(4825)
equipmentHighLaserTemp(4830)
equipmentHighLaserPeltier(4835)
facilityHighRxPower(4840)
equipmentHighTxPower(4845)
equipmentHighTransceiverVoltage(4850)
equipmentLowLaserBias(4855)
equipmentLowLaserTemp(4860)
equipmentLowLaserPeltier(4865)
facilityLowRxPower(4870)
equipmentLowTxPower(4875)
equipmentLowTransceiverVoltage(4880)
equipmentRxLocked(4885)
equipmentSquelched(4890)
equipmentTxLocked(4895)
otukSignalFailure(4900)
odukSignalFailure(4905)
otukSignalDegrade(4910)
odukSignalDegrade(4915)
pluggablePortMissing(4920)
pluggablePortRateMismatch(4925)
pluggablePortSecurityCodeMismatch(4930)
tciNotSelected(4935)
tci1ClockFailure(4940)
odukPMBackwardDefectIndication(4945)
odukTCM1BackwardDefectIndication(4950)
odukTCM2BackwardDefectIndication(4955)
equipmentHighRxTemperature(4960)
equipmentLowRxTemperature(4965)
tci2ClockFailure(4970)
equipmentWavelengthMismatch(4975)
dspCommunicationFailure(4980)
dspFailure(4985)
laserApproachingEndOfLife(5000)
crossconnectLoopback(5010)
adminLogoutOfUser(5020)
userLockedOut(5030)
adminLockoutOfUser(5040)
adminLockoutClear(5050)
invalidLoginUsername(5060)
securityInvalidLoginPassword(5070)
securityInvalidLoginLockedOut(5080)
securityInvalidLoginAlreadyLoggedOn(5090)
loginOfUser(5100)
automaticLogoutOfIdleUser(5110)
logoutOfUser(5120)
enhancedRemoteFailureIndicationPathServer(5200)
enhancedRemoteFailureIndicationPathConnectivity(5210)
enhancedRemoteFailureIndicationPathPayload(5220)
firewallHasBeenDisabled(5230)
securityIntrusionDetPwd(5240)
securityIntrusionDetUser(5250)
connectionEquipmentMismatch(5260)
disableInactiveUser(5270)
disableInactiveClear(5280)
batteryFailure(5290)
extremeHighVolt(5300)
extremeLowVolt(5310)
highVolt(5320)
lowVolt(5330)
suspendUser(5340)
suspendUserClear(5350)
lineDccTerminationFailure(5360)
multiplexSectionDccTerminationFailure(5370)
gigaBitEthernetOutOfSync(5380)
sequenceMismatch(5390)
lossOfAlignment(5400)
outOfUseByAdministrativeCommand(5410)
outOfUseTransportFailure(5420)
vcatGroupDown(5430)
vcatGroupDegraded(5440)
vcatGroupIncomplete(5450)
alarmIndicationSignalInTX(5460)
remoteAlarmIndicationInTX(5470)
kByteAPSChannelFailure(5480)
apsInvalidMode(5490)
ipAddressAlreadyInUseWithinTheSameDccArea(5500)
nodeNameInUseWithinTheSameDccArea(5510)
rearPanelEthernetLinkRemoved(5520)
manualSwitchToProtectResultedInNoTrafficSwitch(5530)
manualSwitchBackToWorkingResultedInNoTrafficSwitch(5540)
forcedSwitchToProtectResultedInNoTrafficSwitch(5550)
forcedSwitchBackToWorkingResultedInNoTrafficSwitch(5560)
duplicateSerialNumberDetectedOnAPluggableEntity(5570)
lossOfSignalForOpticalChannel(5600)
encapsulationMismatchPath(5610)
encapsulationMismatchVT(5620)
encapsulationMismatchHighOrderPath(5630)
encapsulationMismatchLowOrderPath(5640)
gfpUserPayloadMismatch(5650)
gfpFibreChannelDistanceExtensionMismatch(5660)
gfpFibreChannelDistanceExtensionBufferStarvation(5670)
gfpFibreChannelDistanceExtensionCreditStarvation(5680)
automaticWdmAnsFinished(5690)
gfpClientSignalFailDetected(5700)
gfpLossOfFrameDelineation(5710)
gfpExtensionHeaderMismatch(5730)
incomingOverheadSignalAbsent(5740)
opticalSafetyRemoteInterlockOn(5750)
automaticPowerControlCorrectionSkipped(5770)
apcCannotSetValueDueToRangeLimits(5780)
lcasVcgMemberTxSideInAddState(5790)
farEndManualSwitchBackToWorkingSpan(5800)
farEndForcedSwitchBackToWorkingSpan(5810)
universalTransponderModuleHardwareFailure(5820)
universalTransponderModuleCommunicationFailure(5830)
pluginModuleRangeSettingsMismatch(5840)
lcasVcgMemberTxSideInDnuState(5850)
lcasControlWordCrcCheckFailure(5860)
lcasVcgMemberRxSideInFailState(5870)
signalLossOnDataInterface(5880)
synchronizationLossOnDataInterface(5890)
portFAIL(5900)
unreachablePortTargetPower(5910)
portAddPowerDegradeLow(5920)
portAddPowerDegradeHigh(5930)
portAddPowerFailLow(5940)
portAddPowerFailHigh(5950)
automaticPowerControlTerminatedOnManualRequest(6000)
oduk1AlarmIndicationSignal(6010)
oduk2AlarmIndicationSignal(6020)
oduk3AlarmIndicationSignal(6030)
oduk4AlarmIndicationSignal(6040)
temperatureReadingMismatchBetweenSCCards(6050)
voltageReadingMismatchBetweenSCCards(6060)
alarmsSuppressedonOutOfGroupVcatMember(6070)
blsrSoftwareVersionMismatch(6080)
optimized1Plus1ApsPrimaryFacility(6090)
optimized1Plus1ApsPrimarySectionMismatch(6100)
optimized1Plus1ApsInvalidPrimarySection(6110)
compositeClockHighLineVoltage(6120)
berThresholdExceededForSignalDegradeVt(6130)
berThresholdExceededForSignalFailureVt(6140)
spanLengthOutOfRange(6150)
idleSignalCondition(6170)
idleSignalConditionInTx(6180)
vtPathTraceIdentifierMismatch(6190)
lossOfFrameInTX(6200)
provisioningMismatch(6210)
sectionTraceIdentifierMismatch(6220)
regeneratorSectionTraceIdentifierMismatch(6230)
switchingMatrixModuleFailureWorking(6240)
switchingMatrixModuleFailureProtect(6250)
slotCommunicationDisabled(6260)
sessionTimeLimitExpired(6270)
userPasswordChangeRequired(6280)
isisAdjacencyFailure(6290)
msspSoftwareVersionMismatch(6300)
remoteAuthenticationFailSeeAuditLog(6310)
ringIsSquelchingStsTraffic(6330)
ringIsSquelchingVtTraffic(6340)
archiveOfAuditLogFailed(6350)
rprWrapped(6360)
shelfCommunicationFailure(6370)
duplicatedShelfIdentifier(6380)
softwareMismatch(6390)
lmpFailure(6400)
opticalTerminationIncomplete(6410)
forwardDefectIndication(6420)
payloadMissingIndication(6430)
spanMeasurementCannotBePerformed(6440)
ringIsSquelchingHighOrderTraffic(6450)
ringIsSquelchingLowOrderTraffic(6460)
badPacketCountExceedsThreshold(6470)
linkLayerKeepAliveFailure(6480)
autonegotiationRemoteFailureIndication(6490)
trailSignalFail(6500)
ds1LoopbackCommandSentToFarEnd(6510)
multiplexSectionSignalDegraded(6520)
multiplexSectionExcessiveErrors(6530)
highOrderPathSignalDegraded(6540)
highOrderPathExcessiveErrors(6550)
lowOrderPathSignalDegraded(6560)
lowOrderPathExcessiveErrors(6570)
regeneratorSectionDccTerminationFailure(6580)
networkMemoryPoolLow(6590)
ospfRoutingTableOverflow(6600)
autoLaserShutdownDisabled(6610)
rprProtectionIsActive(6630)
maxRPRStationNumberExceeded(6640)
rprProtectionConfigurationMismatched(6650)
reservedBandwidthLinkRateExceededOnRinglet0(6660)
reservedBandwidthLinkRateExceededOnRinglet1(6670)
rprInterfaceInPassThroughMode(6680)
rprPeerNodeIsMissing(6690)
rprRiFailure(6700)
rprSignalFailure(6710)
rprSignalDegrade(6720)
interlinkFailure(6730)
apcWrongGain(6740)
rprSpanMismatch(6750)
efmRemoteFaultIndicationCriticalEvent(6760)
efmRemoteFaultIndicationDyingGasp(6770)
efmRemoteFaultIndicationLinkFault(6780)
efmLinkMonitoringErroredSymbolPeriodEvent(6790)
efmLinkMonitoringErroredFrameEvent(6800)
efmLinkMonitoringErroredFramePeriodEvent(6810)
efmLinkMonitoringErroredFrameSecondsSummary(6820)
efmRemoteLoopbackRequestFailed(6830)
fastAutomaticProtectionSwitching(6840)
fastAutomaticProtectionSwitchingConfigMismatch(6850)
lcasSinkGroupError(6860)
lcasVcgMemberRxSideInDnuState(6870)
fcDistanceExtFuncNotEstablished(6880)
nonCiscoPPMInserted(6890)
unqualifiedPPMInserted(6900)
ftaMismatch(6910)
cardPortsUnableToProvideProtection(6920)
lmpSignalDegrade(6930)
lmpSignalFailure(6940)
lmpUnallocatedDataLink(6950)
frontPortLinkLoss(6960)
bertEnbl(6970)
bertSyncFail(6975)
workQueueFull(6980)
equipmentPowerFailureAtConnectorA(7000)
equipmentPowerFailureAtConnectorB(7005)
equipmentPowerFailureAtReturnConnectorA(7010)
equipmentPowerFailureAtReturnConnectorB(7015)
bridgeAndRollHasOccurred(7055)
bridgeAndRollIsPendingAValidSignal(7060)
clockBusFailureTscA(7160)
clockBusFailureTscB(7165)
ospfHelloFail(7185)
openIOSlots(7200)
lossOfClockFromMateShelfController(7210)
virtualLanAlarmIndiacationSignal(7225)
dcuLossFailure(7230)
ochncMaintenance(7235)
ramanLaserShutdown(7240)
losOfRamanSignal(7245)
mcastMacTableFull(7250)
multicastMacAddressAliasing(7255)
ramanPwrProtOn(7260)
cppPeerNotResponding(7265)
voaControlLoopDisableDueToExcessiveCounterPropagationLight(7275)
wizardIsRunning(7280)
ramanGainNotReached(7285)
pprForwardDefectIndication(7295)
pprBackwardDefectIndication(7300)
pprCoordinatedMaintenance(7305)
pprTriggerThresholdBerExceeded(7310)
localFault(7315)
remoteFault(7320)
efmRemoteLoopbackConfigured(7325)
efmPeerMissing(7330)
eqptDegrade(7335)
excessiveBackPropagation(7340)
remoteMaintenanceEndPointIsDown(7345)
crossConnectedCFMService(7350)
cfmLoop(7355)
cfmConfigurationError(7360)
outOfChannelGroupBundle(7365)
repNeighborAdjacencyFailure(7370)
repLinkFlapping(7375)
faultInREPSegment(7380)
primaryREPEdgePortElected(7385)
secondaryREPEdgePortElected(7390)
stcnREPGenerated(7395)
vlbREPActivated(7400)
vlbREPTriggerSoakingDelayActive(7405)
wanSyncloss(7410)
laserShutdownDueToWavelengthDrift(7415)
manualLaserRestart(7420)
laserShutdownDueToNonCiscoPPMInserted(7425)
ethernetOSCTerminationFailure(7430)
softwareSignatureVerificationFailed(7445)
protectVolumeSoftwareSignatureVerificationFailed(7450)
activeVolumeSoftwareSignatureVerificationFailed(7455)
peerPortClientSignalFailDetected(7460)
channelShutdownDueToWavelengthDrift(7465)
usbWriteFailure(7475)
usbSyncInProgress(7480)
autoSensingUnableToDetectValidPayload(7485)
payloadAutoSensingInProgress(7490)
gfpClientSignalFailDetectedDueToSigloss(7495)
gfpClientSignalFailDetectedDueToSyncloss(7500)
pmdDegrade(7510)
standbyTccNEClockIsInternalClock(7515)
chromaticDispersionValue(7520)
packetTransportServiceFailed(7525)
satellitePanelDiscoveryFailure(7530)
satellitePanelActiveLinkFailure(7535)
satellitePanelCommunicationFailure(7540)
satellitePanelImproperConfiguration(7545)
satellitePanelFanMismatchOfEquipmentAndAttributes(7550)
satellitePanelFanFailure(7555)
satellitePanelPartialFanFailure(7560)
satellitePanelFANManufacturingDataMemoryEEPROMFailure(7565)
satellitePanelFANUnitIsMissing(7570)
satellitePanelIndustrialHighTemperature(7575)
satellitePanelHighTemperature(7580)
satellitePanelBatteryFailureA(7585)
plannedSwitchOver(7590)
protectionCardConfigurationMismatch(7595)
routerProcessorSwitchOver(7600)
runningLowOnResources(7605)
noMoreResourcesAreAvailable(7610)
esmcFailure(7615)
licenseWillExpireWithin24Hours(7620)
licenseWillExpireAnytimeAfter1DayButBefore14Days(7625)
licenseIsExpired(7630)
licenseCountViolation(7635)
temporaryLicenseIsInUse(7640)
evaluationLicenseIsInUse(7645)
licenseIsMissing(7650)
pseudowireDown(7655)
workingPseudowireControlPlaneDown(7660)
protectPseudowireControlPlaneDown(7665)
workingPseudowireConnectivityCheckDown(7670)
protectPseudowireConnectivityCheckDown(7675)
pseudowireTrafficSwitchedToProtection(7680)
workingPseudowireLocalAcTxPortFault(7685)
protectPseudowireLocalAcTxPortFault(7690)
workingPseudowireLocalAcRxPortFault(7695)
protectPseudowireLocalAcRxPortFault(7700)
workingPseudowireRemoteAcTxPortFault(7705)
protectPseudowireRemoteAcTxPortFault(7710)
workingPseudowireRemoteAcRxPortFault(7715)
protectPseudowireRemoteAcRxPortFault(7720)
slaThresholdCrossAlert(7725)
protectLocalPseudowireNotForwarding(7730)
workingPseudowireNotForwarding(7735)
protectPseudowireNotForwarding(7740)
tpTunnelDown(7745)
workingLabelSwitchedPathDown(7750)
protectLabelSwitchedPathDown(7755)
workingLabelSwitchedPathAlarmIndicationSignal(7760)
protectLabelSwitchedPathAlarmIndicationSignal(7765)
workingLabelSwitchedPathRemoteDefectIndication(7770)
protectLabelSwitchedPathRemoteDefectIndication(7775)
bidirectionalForwardDetectionDown(7780)
tpTrafficSwitchedFromWorkingToProtection(7785)
workingTpLockout(7790)
protectTpLockout(7795)
ethernetFlowPointFailed(7800)
teTunnelDown(7805)
macSystemLimitReached(7810)
macBridgeDomainLimitReached(7815)
autoSensingDisabled(7820)
smBackwardIncomingAlignmentError(7825)
resourceAllocationFailed(7830)
lossOfDFBSignal(7835)
workingLabelSwitchedPathLinkDownIndication(7840)
protectLabelSwitchedPathLinkDownIndication(7845)
workingLabelSwitchedPathLockReport(7850)
protectLabelSwitchedPathLockReport(7855)
satellitePanelBatteryFailureB(7860)
highBitErrorRate(7865)
backPanelFacilityLoopback(7870)
backPanelTerminalLoopback(7875)
trunkPayloadTypeMismatch(7880)
invalidMuxponderConfiguration(7885)
coolingProfileMismatch(7890)
trunkOduAlarmIndicationSignal(7895)
companionCardMissing(7900)
controlPlaneUnverifiedClearedAlarmsPresent(7905)
powerConsumptionLimitHasCrossed(7910)
masterKeyExchangeFailed(7915)
unitHighTemperature(7930)
overTemperatureUnitProtected(7935)
seqMismatchCount(7945)
keyProgramOnAlteraFpgaFailed(7960)
duplicateNodeControllerDetected(7970)
restorationInProg(7975)
ramanPumpsCalibrationProcedureIsRunning(7980)
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes(7985)
odukTCM1AlarmIndicationSignal(13100)
odukTCM2AlarmIndicationSignal(13105)
odukLockedDefectTCM1(13110)
odukLockedDefectTCM2(13115)
otukLossOfFrame(13120)
odukOpenConnectionIndicationTCM1(13125)
odukOpenConnectionIndicationTCM2(13130)
odukTrailTraceIdentifierMismatchTCM1(13135)
odukTrailTraceIdentifierMismatchTCM2(13140)
odukSignalFailureTCM1(13145)
odukSignalFailureTCM2(13150)
odukSignalDegradeTCM1(13155)
odukSignalDegradeTCM2(13160)
lossOfChannel(13165)
fecMismatch(13170)
timSectionMonitorTraceIdentifierMismatchFailure(13175)
automaticLaserShutdown(13180)
shutterInsertionLossVariationDegradeLow(13200)
opticalChannelDeactivationFailure(13205)
shutterInsertionLossVariationDegradeHigh(13210)
networkTopologyIncomplete(13215)
pluginModuleCommunicationFailure(13220)
opticalNetworkTypeMismatch(13225)
opticalPowerDegradeLow(13230)
automaticPowerControlFailure(13235)
opticalPowerDegradeHigh(13240)
automaticPowerControlDisabled(13245)
opticalPowerFailureLow(13250)
ringIdMismatch(13255)
opticalPowerFailureHigh(13260)
lossOfContinuity(13270)
variableOpticalAttenuatorDegradeLow(13280)
variableOpticalAttenuatorDegradeHigh(13290)
variableOpticalAttenuatorFailureLow(13300)
variableOpticalAttenuatorFailureHigh(13310)
laserBiasDegrade(13320)
laserBiasFailure(13330)
laserTemperatureDegrade(13340)
opticalAmplifierGainDegradeLow(13350)
opticalAmplifierGainDegradeHigh(13360)
opticalAmplifierGainFailureLow(13370)
opticalAmplifierGainFailureHigh(13380)
opticalChannelConnectionFailure(13390)
opticalChannelIncomplete(13395)
opticalChannelActivationFailure(13400)
laserAutoPowerReduction(13410)
caseTemperatureDegrade(13420)
fiberTemperatureDegrade(13430)
shutterOpen(13440)
awgTemperatureDegrade(13450)
awgTemperatureFailure(13460)
awgOverTemperature(13470)
opticalAmplifierInitialization(13480)
awgWarmUp(13490)
incSigloss(13510)
incSyncloss(13515)
incGfpOutOfFrame(13520)
incGfpSigLoss(13525)
incGfpSyncLoss(13530)
Enumeration
unknownEntity(1)
ne(10)
backplane(30)
eqpt(50)
port(60)
ocn(70)
stmn(71)
aip(80)
fanTray(90)
crs(100)
ds3(110)
almExpPanel(120)
almIfExtnsn(130)
stsMon(140)
vcMonHp(141)
dwdmClient(150)
stsTerm(160)
vcTermHp(161)
dwdmTrunk(170)
dwdmOptics(180)
psSts(190)
rsms(200)
xcSts(210)
bits(220)
dwdmFec(230)
neSynchRef(240)
dwdm8b10b(250)
extSynchRef(260)
dwdmOtn(270)
envAlrm(280)
envCtrl(290)
neRing(360)
ds1(390)
vtMon(410)
vcMonLp(411)
vtTerm(420)
vcTermLP(421)
fUdc(430)
msUdc(440)
spareSdcc(450)
ucpCircuit(480)
ucpIpcc(490)
ucpNeighbor(500)
ec1(510)
ps(520)
psVt(530)
e100t(540)
e1000t(550)
etherBridge(560)
e1(600)
e3(630)
e4(640)
stm1E(650)
ds3i(660)
g1000(670)
ml100t(680)
ml1000(690)
dwdmSfp(700)
dwdmScl(710)
dwdmTcm1(720)
dwdmTcm2(730)
dwdmOcn(740)
dwdmSm(750)
dwdmPm(760)
dwdmTcm(770)
pwr(780)
stsTermVcat(790)
vtTermVcat(800)
vcatGroup(810)
fcmr(820)
entOptics(830)
ce100t(840)
ppm(850)
twor(860)
isc(870)
escon(880)
bic(890)
gfp(900)
gige(910)
pos(920)
cap(930)
dwdmData(940)
logFac(950)
ge(960)
fc(970)
ec1p1(980)
mlFx(990)
ochTerm(1000)
shelf(1010)
ce1000(1020)
cemr(1030)
lmp(1040)
lmpControlChannel(1050)
lmpTeLink(1060)
lmpDataLink(1070)
rpr(1080)
ether(1090)
mlmr(1100)
otu(1110)
aots(3200)
ots(3210)
oms(3220)
och(3230)
osc(3240)
ochnc(3250)
ib(3260)
chgrp(3270)
hdlc(3280)
msISC(3290)
ecu(3300)
lcdFlash(3310)
usb(3320)
fe(3330)
odu0(3350)
odu1(3360)
Conformance Groups (7)
The group for node related objects
.1.3.6.1.4.1.3607.6.10.10.10.10
The group for node related objects
.1.3.6.1.4.1.3607.6.10.10.10.20
alarmUnknown alarmCutoffIsInManualMode failureDetectedExternalToTheNE externalError excessiveSwitching sdccTerminationFailure incomingFailureCondition alarmIndicationSignal alarmIndicationSignalLine alarmIndicationSignalPath alarmIndicationSignalVT apsChannelFailure channelByteFailureAPS channelProtectionSwitchingChannelMatchFailureAPS channelAutomaticProtectionSwitchModeMismatchAPS farEndProtectionLineFailure inconsistentAPSCode improperAPSCode nodeIdMismatch channelDefaultKAPS connectionLoss bipolarViolation carrierLossOnTheLAN concatenationErrorSTS excessCollisionsOnTheLAN facilityFailure farEndAIS farEndMultipleDS1LOSDetectedOnDS3 farEndDS1EqptFailNonServiceAffecting farEndDS1EqptFailServiceAffecting farEndSingleDS1LOS farEndDS3EqptFailNonServiceAffecting farEndDS3EqptFailServiceAffecting farEndCommonEquipmentFailureNonServiceAffecting farEndIDLE farEndLOS farEndLOF farEndBlockError ds3IdleCondition lossOfFrame lossOfPointer lossOfPointerPath lossOfPointerVT lossOfSignal outOfFrame pathSelectorFailure remoteAlarmIndication remoteFailureIndication remoteFailureIndicationLine remoteFailureIndicationPath remoteFailureIndicationVT signalDegrade severelyErroredFrame signalFailure signalLabelMismatchFailure payloadDefectIndication payloadDefectIndicationPath payloadLabelMismatchPath signalLabelMismatchFailurePayloadLabelMismatchVT unequippedPath signalLabelMismatchFailureUnequippedVT lossOfSynchronization outOfSynchronization primarySynchronizationReferenceFailure secondarySynchronizationReferenceFailure thirdSynchronizationReferenceFailure fourthSynchronizationReferenceFailure fifthSynchronizationReferenceFailure sixthSynchronizationReferenceFailure failedToReceiveSynchronizationStatusMessage synchronizationStatusMessagesAreDisabledOnThisInterface stratum1PrimaryReferenceSourceTraceable synchronizedTraceabilityUnknown stratum2Traceable transitNodeClockTraceable stratum3ETraceable stratum3Traceable sonetMinimumClockTraceable stratum4Traceable doNotUseForSynchronization reservedForNetworkSynchronizationUse outgoingFailureCondition remoteDefectIndicationLine remoteDefectIndicationPath freeRunningSynchronizationMode holdoverSynchronizationMode fastStartSynchronizationMode internalFault internalError internalMessageError mismatchOfEquipmentAndAttributes watchdogTimerTimeout softwareFaultOrFailure softwareFaultDataIntegrityFault programFailure controlEquipmentFailure primaryNonVolatileBackupMemoryFailure secondaryNonVolatileBackupMemoryFailure controlBusFailure controlBus1Failure controlBus2Failure tccAToShelfSlot1DROP1CommunicationFailure tccAToShelfSlot2DROP2CommunicationFailure tccAToShelfSlot3DROP3CommunicationFailure tccAToShelfSlot4DROP4CommunicationFailure tccAToShelfSlot5TRUNK1CommunicationFailure tccAToShelfSlot6TRUNK2CommunicationFailure tccAToShelfSlot7TCCACommunicationFailure tccAToShelfSlot8XCONACommunicationFailure tccAToShelfSlot9AICCommunicationFailure tccAToShelfSlot10XCONBCommunicationFailure tccAToShelfSlot11TCCBCommunicationFailure tccAToShelfSlot12TRUNK3CommunicationFailure tccAToShelfSlot13TRUNK4CommunicationFailure tccAToShelfSlot14DROP5CommunicationFailure tccAToShelfSlot15DROP6CommunicationFailure tccAToShelfSlot16DROP7CommunicationFailure tccAToShelfSlot17DROP8CommunicationFailure tccAToDCCAProcessorCommunicationFailure tccBToShelfSlot1DROP1CommunicationFailure tccBToShelfSlot2DROP2CommunicationFailure tccBToShelfSlot3DROP3CommunicationFailure tccBToShelfSlot4DROP4CommunicationFailure tccBToShelfSlot5TRUNK1CommunicationFailure tccBToShelfSlot6TRUNK2CommunicationFailure tccBToShelfSlot7TCCACommunicationFailure tccBToShelfSlot8XCONACommunicationFailure tccBToShelfSlot9AICCommunicationFailure tccBToShelfSlot10XCONBCommunicationFailure tccBToShelfSlot11TCCBCommunicationFailure tccBToShelfSlot12TRUNK3CommunicationFailure tccBToShelfSlot13TRUNK4CommunicationFailure tccBToShelfSlot14DROP5CommunicationFailure tccBToShelfSlot15DROP6CommunicationFailure tccBToShelfSlot16DROP7CommunicationFailure tccBToShelfSlot17DROP8CommunicationFailure tccBToDCCBProcessorCommunicationFailure controlEquipmentControlCommunicationsEquipmentFailure controlProcessorFailure workingMemoryFailure interconnectionEquipmentFailure payloadBusFailureToIOSlot1XCONSlot8 payloadBusFailureToIOSlot2XCONSlot8 payloadBusFailureToIOSlot3XCONSlot8 payloadBusFailureToIOSlot4XCONSlot8 payloadBusFailureToIOSlot5XCONSlot8 payloadBusFailureToIOSlot6XCONSlot8 payloadBusFailureToIOSlot12XCONSlot8 payloadBusFailureToIOSlot13XCONSlot8 payloadBusFailureToIOSlot14XCONSlot8 payloadBusFailureToIOSlot15XCONSlot8 payloadBusFailureToIOSlot16XCONSlot8 payloadBusFailureToIOSlot17XCONSlot8 payloadBusFailureToIOSlot1XCONSlot10 payloadBusFailureToIOSlot2XCONSlot10 payloadBusFailureToIOSlot3XCONSlot10 payloadBusFailureToIOSlot4XCONSlot10 payloadBusFailureToIOSlot5XCONSlot10 payloadBusFailureToIOSlot6XCONSlot10 payloadBusFailureToIOSlot12XCONSlot10 payloadBusFailureToIOSlot13XCONSlot10 payloadBusFailureToIOSlot14XCONSlot10 payloadBusFailureToIOSlot15XCONSlot10 payloadBusFailureToIOSlot16XCONSlot10 payloadBusFailureToIOSlot17XCONSlot10 timeSlotInterchangeEquipmentFailure equipmentFailure highTemperature invalidMACAddress boardFailure diagnosticFailure mediumAccessControlFailure facilityTerminationEquipmentFailure automaticLaserShutoffDueToHighTemperature failureToReleaseFromProtection receiverFailure transmitFailure facilityTerminationEquipmentReceiverMissing facilityTerminationEquipmentTransmitterMissing failureToSwitchToProtection failureToSwitchToProtectionRing failureToSwitchToProtectionSpan failureToSwitchToProtectionPath fanFailure equipmentUnitPlugIn nePowerFailureAtConnector fuseAlarm synchronizationUnitFailure synchronizationSwitchingEquipmentFailure equipmentUnitUnplugged loopback ds1LoopbackDueToFEACCommand loopbackCommandSentToFarEndDS1 ds3LoopbackDueToFEACCommand ds3LoopbackCommandSentToFarEnd ds2LoopbackDueToFarEndCommand ds2LoopbackCommandSentToFarEnd facilityLoopback networkLoopback terminalLoopback manuallyCausedAbnormalCondition ethernetBridgeIsNewRootOfSpanningTree ethernetBridgeTopologyChange normalCondition embeddedOperationsChannelFailureLinkDown peerStateMismatch proceduralError improperRemoval duplicateNodeID blsrOutOfSync blsrMultiNodeTableUpdateCompleted protectionUnitNotAvailable performanceMonitorThresholdCrossingAlert protectionSwitch recoveryOrServiceProtectionActionHasBeenInitiated automaticSystemReset automaticUPSRSwitchCausedByAIS automaticUPSRSwitchCausedByLOP automaticUPSRSwitchCausedByUNEQ automaticUPSRSwitchCausedByPDI automaticUPSRSwitchCausedBySFBER automaticUPSRSwitchCausedBySDBER coldRestart forcedSwitchBackToWorking forcedSwitchBackToWorkingRing forcedSwitchBackToWorkingSpan forcedSwitchToProtection forcedSwitchToProtectionRing forcedSwitchToProtectionSpan workingFacilityOrEquipmentForcedToSwitchToProtectionPath initializationInitiated lockoutOfProtection lockoutOfProtectionRing lockoutOfProtectionSpan lockoutOfProtectionPath lockoutOfWorking lockoutOfWorkingRing lockoutOfWorkingSpan manualSystemReset manualSwitchToInternalClock manualSwitchToPrimaryReference manualSwitchToSecondReference manualSwitchToThirdReference manualSwitchToFourthReference manualSwitchToFifthReference manualSwitchToSixthReference manualSwitchBackToWorking manualSwitchBackToWorkingRing manualSwitchBackToWorkingSpan manualSwitchToProtection manualSwitchToProtectionRing manualSwitchToProtectionSpan manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath powerfailRestart ringIsSquelchingTraffic softwareDownloadInProgress switchToInternalClock switchToPrimaryReference switchToSecondReference switchToThirdReference switchToFourthReference switchToFifthReference switchToSixthReference systemReboot switchedBackToWorking switchedToProtection warmRestart ringIsInWaitToRestoreState manualSwitchRequest forcedSwitchRequest lockoutSwitchRequest rmonHistoriesAndAlarmsResetReboot rmonThresholdCrossingAlarm alarmsSuppressedByUserCommand alarmsSuppressedForMaintenance switchingMatrixModuleFailure lanConnectionPolarityReversed autonomousPMReportMessageInhibited ioSlotToXCONCommunicationFailure stsPathTraceIdentifierMismatch nePowerFailureAtConnectorA nePowerFailureAtConnectorB freeMemoryOnCardVeryLow freeMemoryOnCardNearZero exerciseRequestOnRing exerciseRequestOnSpan squelchingPath extraTrafficPreempted farEndLockoutOfWorkingRing farEndLockoutOfWorkingSpan farEndLockoutOfProtectionRing farEndLockoutOfProtectionAllSpans farEndWorkingFacilityForcedToSwitchToProtectionRing farEndWorkingFacilityForcedToSwitchToProtectionSpan farEndManualSwitchOfWorkingFacilityToProtectionRing farEndManualSwitchOfWorkingFacilityToProtectionSpan farEndExercisingRing farEndExercisingSpan farEndBERThresholdPassedForSignalFailureRing farEndBERThresholdPassedForSignalFailureSpan farEndBERThresholdPassedForSignalDegradeRing farEndBERThresholdPassedForSignalDegradeSpan apsChannelFarEndProtectionLineSignalDegrade ringSwitchIsActiveOnTheEastSide ringSwitchIsActiveOnTheWestSide spanSwitchIsActiveOnTheEastSide spanSwitchIsActiveOnTheWestSide uniDirectionalFullPassThroughIsActive biDirectionalFullPassThroughIsActive kBytesPassThroughIsActive ringIsSegmented ringTopologyIsUnderConstruction lockoutOfProtectionAllSpans farEndOfFiberIsProvisionedWithDifferentRingID bothEndsOfFiberProvisionedAsEastOrBothAsWest autonomousMessagesInhibited trafficStormOnLANLANTemporarilyDisabled reptdbchgMessagesInhibited securityUserIDHasExpired partialFanFailure forcedSwitchRequestOnRing forcedSwitchRequestOnSpan lockoutSwitchRequestOnRing lockoutSwitchRequestOnSpan manualSwitchRequestOnRing manualSwitchRequestOnSpan communicationFailurePeerToPeerSlotControlBusA communicationFailurePeerToPeerSlotControlBusB controllerAToShelfSlotCommunicationFailure controllerBToShelfSlotCommunicationFailure interconnectionEquipmentFailureWorkingPayloadBus interconnectionEquipmentFailureProtectPayloadBus inhibitSwitchToProtectRequestOnEquipment inhibitSwitchToWorkingRequestOnEquipment exercisingRingSuccessfully exercisingSpanSuccessfully spanIsInWaitToRestoreState exerciseRequestOnRingFailed exerciseRequestOnSpanFailed farEndLockoutOfProtectionSpan manufacturingDataMemoryEEPROMFailure replaceableEquipmentOrUnitIsMissing softwareDownloadFailed extraTrafficPCADropped etherTxOversubscribed etherRxOverSubscribed etherTxExcessFlowCtrl etherRxExcessFlowCtrl transportLayerFailure etherTxUnderrun synchronizationReferenceFrequencyOutOfBounds ntpOrSntpHostFailure peerCardNotResponding alarmsAndEventsSuppressedForThisObject ds3FrameFormatMismatch timSectionTraceIdentifierMismatchFailure aisMultiplexSectionAlarmIndicationSignal rdiMultiplexSectionRemoteDefectOrAlarmIndication timHighOrderTraceIdentifierMismatchFailure aisAdministrationUnitAlarmIndicationSignal lopAdministrationUnitLossOfPointer slmfUnequippedHighOrderPathUnequipped slmfPLMHighOrderPathLabelMismatch rdiHighOrderRemoteDefectOrAlarmIndication lopTributaryUnitLossOfPointer aisTributaryUnitAlarmIndicationSignal slmfUnequippedLowOrderPathUnequipped slmfPLMLowOrderPathLabelMismatch timLowOrderTraceIdentifierMismatchFailure rfiLowOrderRemoteFailureOrAlarmIndication g811PrimaryReferenceClockTraceable g812TransitNodeClockTraceable g812LocalNodeClockTraceable g813SynchronousEquipmentTimingSourceTraceable e1LoopbackDueToFEACCommand e1LoopbackCommandSentToFarEnd e3LoopbackDueToFEACCommand farEndMultipleE1LOSDetectedOnE3 farEndE1EqptFailNonServiceAffecting farEndE1EqptFailServiceAffecting farEndSingleE1LOS farEndE3EqptFailServiceAffecting e3LoopbackCommandSentToFarEnd farEndE3EqptFailNonServiceAffecting lowVoltBatteryA highVoltBatteryA lowVoltBatteryB highVoltBatteryB msspRingOutOfSync msspMultiNodeTableUpdateCompleted automaticSNCPSwitchCausedByAIS automaticSNCPSwitchCausedByLOP automaticSNCPSwitchCausedByUNEQ automaticSNCPSwitchCausedByPDI automaticSNCPSwitchCausedBySFBER automaticSNCPSwitchCausedBySDBER stmConcatenationError e3IdleCondition channelMSSPInconsistentAPSCode channelMSSPImproperAPSCodeAPS channelMSSPNodeIdMismatchAPS channelMSSPDefaultKAPS channelMSSPConnectionLossAPS minimumClockTraceableSDH lineIsInWaitToRestoreStateSDH berThresholdExceededForSignalDegradeHighOrder berThresholdExceededForSignalFailureHighOrder berThresholdExceededForSignalDegradeLowOrder berThresholdExceededForSignalFailureLowOrder failureToSwitchToProtectionHighOrderPath failureToSwitchToProtectionLowOrderPath a8b10bOutOfSync odukPMAlarmIndicationSignal otukAlarmIndicationSignal otukSMBackwardDefectIndication odukBackwardDefectIndication fecUncorrectedWord gccTerminationFailure otukIncomingAlignmentError odukLockedDefectPM lossOfMultiFrame odukOpenConnectionIndication payloadTypeIdentifierMismatch odukTrailTraceIdentifierMismatch otukTrailTraceIdentifierMismatch equipmentHighLaserBias equipmentHighLaserTemp equipmentHighLaserPeltier facilityHighRxPower equipmentHighTxPower equipmentHighTransceiverVoltage equipmentLowLaserBias equipmentLowLaserTemp equipmentLowLaserPeltier facilityLowRxPower equipmentLowTxPower equipmentLowTransceiverVoltage equipmentRxLocked equipmentSquelched equipmentTxLocked otukSignalFailure odukSignalFailure otukSignalDegrade odukSignalDegrade pluggablePortMissing pluggablePortRateMismatch pluggablePortSecurityCodeMismatch tciNotSelected tci1ClockFailure odukPMBackwardDefectIndication odukTCM1BackwardDefectIndication odukTCM2BackwardDefectIndication equipmentHighRxTemperature equipmentLowRxTemperature tci2ClockFailure equipmentWavelengthMismatch dspCommunicationFailure dspFailure laserApproachingEndOfLife crossconnectLoopback adminLogoutOfUser userLockedOut adminLockoutOfUser adminLockoutClear invalidLoginUsername securityInvalidLoginPassword securityInvalidLoginLockedOut securityInvalidLoginAlreadyLoggedOn loginOfUser automaticLogoutOfIdleUser logoutOfUser firewallHasBeenDisabled connectionEquipmentMismatch disableInactiveUser disableInactiveClear batteryFailure extremeHighVolt extremeLowVolt highVolt lowVolt suspendUser suspendUserClear lineDccTerminationFailure multiplexSectionDccTerminationFailure gigaBitEthernetOutOfSync sequenceMismatch lossOfAlignment outOfUseByAdministrativeCommand outOfUseTransportFailure vcatGroupDown vcatGroupDegraded vcatGroupIncomplete alarmIndicationSignalInTX remoteAlarmIndicationInTX kByteAPSChannelFailure apsInvalidMode ipAddressAlreadyInUseWithinTheSameDccArea nodeNameInUseWithinTheSameDccArea rearPanelEthernetLinkRemoved manualSwitchToProtectResultedInNoTrafficSwitch manualSwitchBackToWorkingResultedInNoTrafficSwitch forcedSwitchToProtectResultedInNoTrafficSwitch forcedSwitchBackToWorkingResultedInNoTrafficSwitch duplicateSerialNumberDetectedOnAPluggableEntity lossOfSignalForOpticalChannel encapsulationMismatchPath encapsulationMismatchVT encapsulationMismatchHighOrderPath encapsulationMismatchLowOrderPath gfpUserPayloadMismatch gfpFibreChannelDistanceExtensionMismatch gfpFibreChannelDistanceExtensionBufferStarvation gfpFibreChannelDistanceExtensionCreditStarvation gfpClientSignalFailDetected gfpLossOfFrameDelineation gfpExtensionHeaderMismatch lcasVcgMemberTxSideInAddState lcasVcgMemberTxSideInDnuState lcasControlWordCrcCheckFailure lcasVcgMemberRxSideInFailState signalLossOnDataInterface synchronizationLossOnDataInterface portFAIL unreachablePortTargetPower portAddPowerDegradeLow portAddPowerDegradeHigh portAddPowerFailLow portAddPowerFailHigh automaticWdmAnsFinished incomingOverheadSignalAbsent opticalSafetyRemoteInterlockOn automaticPowerControlCorrectionSkipped apcCannotSetValueDueToRangeLimits farEndManualSwitchBackToWorkingSpan farEndForcedSwitchBackToWorkingSpan universalTransponderModuleHardwareFailure universalTransponderModuleCommunicationFailure pluginModuleRangeSettingsMismatch automaticPowerControlTerminatedOnManualRequest oduk1AlarmIndicationSignal oduk2AlarmIndicationSignal oduk3AlarmIndicationSignal oduk4AlarmIndicationSignal temperatureReadingMismatchBetweenSCCards voltageReadingMismatchBetweenSCCards alarmsSuppressedonOutOfGroupVcatMember blsrSoftwareVersionMismatch optimized1Plus1ApsPrimaryFacility optimized1Plus1ApsPrimarySectionMismatch optimized1Plus1ApsInvalidPrimarySection compositeClockHighLineVoltage berThresholdExceededForSignalDegradeVt berThresholdExceededForSignalFailureVt spanLengthOutOfRange idleSignalCondition idleSignalConditionInTx vtPathTraceIdentifierMismatch lossOfFrameInTX provisioningMismatch sectionTraceIdentifierMismatch regeneratorSectionTraceIdentifierMismatch switchingMatrixModuleFailureWorking switchingMatrixModuleFailureProtect slotCommunicationDisabled sessionTimeLimitExpired userPasswordChangeRequired isisAdjacencyFailure msspSoftwareVersionMismatch remoteAuthenticationFailSeeAuditLog ringIsSquelchingStsTraffic ringIsSquelchingVtTraffic archiveOfAuditLogFailed rprWrapped shelfCommunicationFailure duplicatedShelfIdentifier softwareMismatch lmpFailure opticalTerminationIncomplete forwardDefectIndication payloadMissingIndication spanMeasurementCannotBePerformed ringIsSquelchingHighOrderTraffic ringIsSquelchingLowOrderTraffic badPacketCountExceedsThreshold linkLayerKeepAliveFailure autonegotiationRemoteFailureIndication trailSignalFail ds1LoopbackCommandSentToFarEnd multiplexSectionSignalDegraded multiplexSectionExcessiveErrors highOrderPathSignalDegraded highOrderPathExcessiveErrors lowOrderPathSignalDegraded lowOrderPathExcessiveErrors regeneratorSectionDccTerminationFailure networkMemoryPoolLow ospfRoutingTableOverflow autoLaserShutdownDisabled rprProtectionIsActive maxRPRStationNumberExceeded rprProtectionConfigurationMismatched reservedBandwidthLinkRateExceededOnRinglet0 reservedBandwidthLinkRateExceededOnRinglet1 rprInterfaceInPassThroughMode rprPeerNodeIsMissing rprRiFailure rprSignalFailure rprSignalDegrade interlinkFailure apcWrongGain rprSpanMismatch efmRemoteFaultIndicationCriticalEvent efmRemoteFaultIndicationDyingGasp efmRemoteFaultIndicationLinkFault efmLinkMonitoringErroredSymbolPeriodEvent efmLinkMonitoringErroredFrameEvent efmLinkMonitoringErroredFramePeriodEvent efmLinkMonitoringErroredFrameSecondsSummary efmRemoteLoopbackRequestFailed fastAutomaticProtectionSwitching fastAutomaticProtectionSwitchingConfigMismatch lcasSinkGroupError lcasVcgMemberRxSideInDnuState fcDistanceExtFuncNotEstablished nonCiscoPPMInserted unqualifiedPPMInserted ftaMismatch cardPortsUnableToProvideProtection lmpSignalDegrade lmpSignalFailure lmpUnallocatedDataLink frontPortLinkLoss bertEnbl bertSyncFail workQueueFull equipmentPowerFailureAtConnectorA equipmentPowerFailureAtConnectorB equipmentPowerFailureAtReturnConnectorA equipmentPowerFailureAtReturnConnectorB ospfHelloFail openIOSlots lossOfClockFromMateShelfController virtualLanAlarmIndicationSignal dcuLossFailure ochncMaintenance ramanLaserShutdown losOfRamanSignal mcastMacTableFull multicastMacAddressAliasing ramanPwrProtOn cppPeerNotResponding voaControlLoopDisableDueToExcessiveCounterPropagationLight wizardIsRunning ramanGainNotReached localFault remoteFault efmRemoteLoopbackConfigured efmPeerMissing eqptDegrade excessiveBackPropagation remoteMaintenanceEndPointIsDown crossConnectedCFMService cfmLoop cfmConfigurationError outOfChannelGroupBundle repNeighborAdjacencyFailure repLinkFlapping faultInREPSegment primaryREPEdgePortElected secondaryREPEdgePortElected stcnREPGenerated vlbREPActivated vlbREPTriggerSoakingDelayActive pprForwardDefectIndication pprBackwardDefectIndication pprCoordinatedMaintenance pprTriggerThresholdBERExceeded wanSyncloss laserShutdownDueToWavelengthDrift manualLaserRestart laserShutdownDueToNonCiscoPPMInserted ethernetOSCTerminationFailure enhancedRemoteFailureIndicationPathServer enhancedRemoteFailureIndicationPathConnectivity enhancedRemoteFailureIndicationPathPayload securityIntrusionDetPwd securityIntrusionDetUser backPanelFacilityLoopback backPanelTerminalLoopback trunkPayloadTypeMismatch invalidMuxponderConfiguration coolingProfileMismatch trunkOduAlarmIndicationSignal companionCardMissing masterKeyExchangeFailed powerConsumptionLimitHasCrossed controlPlaneUnverifiedClearedAlarmsPresent unitHighTemperature overTemperatureUnitProtected seqMismatchCount keyProgramOnAlteraFpgaFailed duplicateNodeControllerDetected restorationInProg ramanPumpsCalibrationProcedureIsRunning ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes odukTCM1AlarmIndicationSignal odukTCM2AlarmIndicationSignal odukLockedDefectTCM1 odukLockedDefectTCM2 otukLossOfFrame odukOpenConnectionIndicationTCM1 odukOpenConnectionIndicationTCM2 odukTrailTraceIdentifierMismatchTCM1 odukTrailTraceIdentifierMismatchTCM2 odukSignalFailureTCM1 odukSignalFailureTCM2 odukSignalDegradeTCM1 odukSignalDegradeTCM2 lossOfChannel fecMismatch timSectionMonitorTraceIdentifierMismatchFailure automaticLaserShutdown shutterInsertionLossVariationDegradeLow opticalChannelDeactivationFailure shutterInsertionLossVariationDegradeHigh networkTopologyIncomplete pluginModuleCommunicationFailure opticalNetworkTypeMismatch forcedSwitchToPrimaryReference forcedSwitchToSecondReference forcedSwitchToThirdReference forcedSwitchToInternalClock industrialHighTemperature opticalPowerDegradeLow automaticPowerControlFailure opticalPowerDegradeHigh automaticPowerControlDisabled opticalPowerFailureLow ringIdMismatch opticalPowerFailureHigh lossOfContinuity variableOpticalAttenuatorDegradeLow variableOpticalAttenuatorDegradeHigh variableOpticalAttenuatorFailureLow variableOpticalAttenuatorFailureHigh laserBiasDegrade laserBiasFailure laserTemperatureDegrade opticalAmplifierGainDegradeLow opticalAmplifierGainDegradeHigh opticalAmplifierGainFailureLow opticalAmplifierGainFailureHigh opticalChannelConnectionFailure opticalChannelIncomplete opticalChannelActivationFailure laserAutoPowerReduction caseTemperatureDegrade fiberTemperatureDegrade shutterOpen awgTemperatureDegrade awgTemperatureFailure awgOverTemperature opticalAmplifierInitialization awgWarmUp incSigloss incSyncloss incGfpOutOfFrame incGfpSigLoss incGfpSyncLoss bridgeAndRollHasOccurred bridgeAndRollIsPendingAValidSignal clockBusFailureTscA clockBusFailureTscB waitToRestore extremeHighVoltBatteryA extremeLowVoltBatteryA extremeHighVoltBatteryB extremeLowVoltBatteryB iosConfigCopyFailed iosConfigCopyInProgress iosConfigCopySuccess signalingUnableToSetupCircuit errorInStartupConfig noStartupConfig needToSaveRunningConfig invalidAlarm rsvpHelloFSMToNeighborDown securityInvalidLoginUsername databaseBackupFailed databaseRestoreFailed lmpHelloFSMToControlChannelDown lmpNeighborDiscoveryHasFailed auditLog80PercentFull moduleCommunicationFailure auditLog100PercentFullOldestRecordsWillBeLost standbyDatabaseOutOfSync redundantPowerCapabilityLost lofAdministrationUnitLossOfMultiFrame sdhSpanIsInWaitToRestoreState berThresholdExceededForSignalDegradeLine berThresholdExceededForSignalDegradePath berThresholdExceededForSignalFailureLine berThresholdExceededForSignalFailurePath unauthorizedIncomingSignalingRequest
The notifications for Cisco ONS 15454
.1.3.6.1.4.1.3607.6.10.10.10.30
The objects for storing all the current alarms
.1.3.6.1.4.1.3607.6.10.10.10.40
The objects for storing all the current alarms
.1.3.6.1.4.1.3607.6.10.10.10.50
The notifications for Cisco ONS 15454 that have been deprecated
.1.3.6.1.4.1.3607.6.10.10.10.60
The group for reported alarm objects
.1.3.6.1.4.1.3607.6.10.10.10.80
Compliance Statements (1)

OID .1.3.6.1.4.1.3607.6.10.10.20.10
The basic implementation requirements for Cisco ONS 15454 MIB
Required groups
Notifications / Traps (888)
NameOIDDescription
.1.3.6.1.4.1.3607.6.10.30.0.1
alarm unknown
.1.3.6.1.4.1.3607.6.10.30.0.10
alarm cutoff is in manual mode
.1.3.6.1.4.1.3607.6.10.30.0.100
alarm indication signal VT
.1.3.6.1.4.1.3607.6.10.30.0.1000
Control Bus 2 Failure
.1.3.6.1.4.1.3607.6.10.30.0.1010
TCC A To Shelf Slot 1 (DROP 1) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1020
TCC A To Shelf Slot 2 (DROP 2) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1030
TCC A To Shelf Slot 3 (DROP 3) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1040
TCC A To Shelf Slot 4 (DROP 4) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1050
TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1060
TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1070
TCC A To Shelf Slot 7 (TCC A) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1080
TCC A To Shelf Slot 8 (XCON A) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1090
TCC A To Shelf Slot 9 (AIC) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.110
APS Channel Failure
.1.3.6.1.4.1.3607.6.10.30.0.1100
TCC A To Shelf Slot 10 (XCON B) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1110
TCC A To Shelf Slot 11 (TCC B) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1120
TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1130
TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1140
TCC A To Shelf Slot 14 (DROP 5) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1150
TCC A To Shelf Slot 15 (DROP 6) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1160
TCC A To Shelf Slot 16 (DROP 7) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1170
TCC A To Shelf Slot 17 (DROP 8) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1180
communication failure TCC A to DCC A processor
.1.3.6.1.4.1.3607.6.10.30.0.1190
TCC B To Shelf Slot 1 (DROP 1) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.120
channel Byte failure APS
.1.3.6.1.4.1.3607.6.10.30.0.1200
TCC B To Shelf Slot 2 (DROP 2) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1210
TCC B To Shelf Slot 3 (DROP 3) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1220
TCC B To Shelf Slot 4 (DROP 4) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1230
TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1240
TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1250
TCC B To Shelf Slot 7 (TCC A) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1260
TCC B To Shelf Slot 8 (XCON A) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1270
TCC B To Shelf Slot 9 (AIC) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1280
TCC B To Shelf Slot 10 (XCON B) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1290
TCC B To Shelf Slot 11 (TCC B) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.130
channel Protection Switching Channel Match failure APS
.1.3.6.1.4.1.3607.6.10.30.0.1300
TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1310
TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13100
ODUk: TCM1 Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.13105
ODUk: TCM2 Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.13110
ODUk Locked Defect - TCM1
.1.3.6.1.4.1.3607.6.10.30.0.13115
ODUk Locked Defect - TCM2
.1.3.6.1.4.1.3607.6.10.30.0.13120
OTUk: Loss Of Frame
.1.3.6.1.4.1.3607.6.10.30.0.13125
ODUk Open Connection Indication TCM1
.1.3.6.1.4.1.3607.6.10.30.0.13130
ODUk Open Connection Indication TCM2
.1.3.6.1.4.1.3607.6.10.30.0.13135
ODUk Trail Trace Identifier Mismatch TCM1
.1.3.6.1.4.1.3607.6.10.30.0.13140
ODUk Trail Trace Identifier Mismatch TCM2
.1.3.6.1.4.1.3607.6.10.30.0.13145
ODUk Signal Failure - TCM1
.1.3.6.1.4.1.3607.6.10.30.0.13150
ODUk Signal Failure - TCM2
.1.3.6.1.4.1.3607.6.10.30.0.13155
ODUk Signal Degrade - TCM1
.1.3.6.1.4.1.3607.6.10.30.0.13160
ODUk Signal Degrade - TCM2
.1.3.6.1.4.1.3607.6.10.30.0.13165
Loss of Channel
.1.3.6.1.4.1.3607.6.10.30.0.13170
FEC Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.13175
TIM Section Monitor - Trace Identifier Mismatch Failure
.1.3.6.1.4.1.3607.6.10.30.0.13180
Automatic Laser Shutdown
.1.3.6.1.4.1.3607.6.10.30.0.1320
TCC B To Shelf Slot 14 (DROP 5) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13200
Shutter Insertion Loss Variation Degrade Low
.1.3.6.1.4.1.3607.6.10.30.0.13205
Optical Channel de-activation failure
.1.3.6.1.4.1.3607.6.10.30.0.13210
Shutter Insertion Loss Variation Degrade High
.1.3.6.1.4.1.3607.6.10.30.0.13215
Network Topology Incomplete
.1.3.6.1.4.1.3607.6.10.30.0.13220
Plug-in Module Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13225
Optical Network Type Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.13230
Optical Power Degrade Low
.1.3.6.1.4.1.3607.6.10.30.0.13235
Automatic Power Control Failure
.1.3.6.1.4.1.3607.6.10.30.0.13240
Optical Power Degrade High
.1.3.6.1.4.1.3607.6.10.30.0.13245
Automatic Power Control Disabled
.1.3.6.1.4.1.3607.6.10.30.0.13250
Optical Power Failure Low
.1.3.6.1.4.1.3607.6.10.30.0.13255
Ring Id Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.13260
Optical Power Failure High
.1.3.6.1.4.1.3607.6.10.30.0.13270
Loss Of Continuity
.1.3.6.1.4.1.3607.6.10.30.0.13280
Variable Optical Attenuator Degrade Low
.1.3.6.1.4.1.3607.6.10.30.0.13290
Variable Optical Attenuator Degrade High
.1.3.6.1.4.1.3607.6.10.30.0.1330
TCC B To Shelf Slot 15 (DROP 6) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13300
Variable Optical Attenuator Failure Low
.1.3.6.1.4.1.3607.6.10.30.0.13310
Variable Optical Attenuator Failure High
.1.3.6.1.4.1.3607.6.10.30.0.13320
Laser Bias Degrade
.1.3.6.1.4.1.3607.6.10.30.0.13330
aser Bias Failure
.1.3.6.1.4.1.3607.6.10.30.0.13340
Laser Temperature Degrade
.1.3.6.1.4.1.3607.6.10.30.0.13350
Optical Amplifier Gain Degrade Low
.1.3.6.1.4.1.3607.6.10.30.0.13360
Optical Amplifier Gain Degrade High
.1.3.6.1.4.1.3607.6.10.30.0.13370
Optical Amplifier Gain Failure Low
.1.3.6.1.4.1.3607.6.10.30.0.13380
Optical Amplifier Gain Failure High
.1.3.6.1.4.1.3607.6.10.30.0.13390
Optical Channel connection failure
.1.3.6.1.4.1.3607.6.10.30.0.13395
Optical Channel Incomplete
.1.3.6.1.4.1.3607.6.10.30.0.1340
TCC B To Shelf Slot 16 (DROP 7) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13400
Optical Channel activation failure
.1.3.6.1.4.1.3607.6.10.30.0.13410
Laser Auto Power Reduction
.1.3.6.1.4.1.3607.6.10.30.0.13420
Case Temperature Degrade
.1.3.6.1.4.1.3607.6.10.30.0.13430
Fiber Temperature Degrade
.1.3.6.1.4.1.3607.6.10.30.0.13440
Shutter Open
.1.3.6.1.4.1.3607.6.10.30.0.13450
AWG Temperature Degrade
.1.3.6.1.4.1.3607.6.10.30.0.13460
AWG Temperature Failure
.1.3.6.1.4.1.3607.6.10.30.0.13470
AWG Over-Temperature
.1.3.6.1.4.1.3607.6.10.30.0.13480
Optical Amplifier Initialization
.1.3.6.1.4.1.3607.6.10.30.0.13490
AWG Warm Up
.1.3.6.1.4.1.3607.6.10.30.0.1350
TCC B To Shelf Slot 17 (DROP 8) Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.13510
Incoming Signal Loss on Fibre Channel Interface
.1.3.6.1.4.1.3607.6.10.30.0.13515
Incoming Synchronization Loss on Fibre Channel Interface
.1.3.6.1.4.1.3607.6.10.30.0.13520
Out Of Frame Detected by GFP Receiver
.1.3.6.1.4.1.3607.6.10.30.0.13525
Client Signal Loss Frames Detected by GFP Receiver
.1.3.6.1.4.1.3607.6.10.30.0.13530
Client Sychronization Loss Frames Detected by GFP Receiver
.1.3.6.1.4.1.3607.6.10.30.0.1360
TCC B To DCC B Processor Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.1370
control Equipment Control Communications equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.1380
Control Processor Failure
.1.3.6.1.4.1.3607.6.10.30.0.1390
Working Memory Failure
.1.3.6.1.4.1.3607.6.10.30.0.140
channel Automatic Protection Switch Mode Mismatch APS
.1.3.6.1.4.1.3607.6.10.30.0.1400
interconnection Equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.1410
Payload Bus Failure To IO Slot 1 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1420
Payload Bus Failure To IO Slot 2 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1430
Payload Bus Failure To IO Slot 3 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1440
Payload Bus Failure To IO Slot 4 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1450
Payload Bus Failure To IO Slot 5 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1460
Payload Bus Failure To IO Slot 6 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1470
Payload Bus Failure To IO Slot 12 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1480
Payload Bus Failure To IO Slot 13 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1490
Payload Bus Failure To IO Slot 14 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.150
Far End Protection Line Failure
.1.3.6.1.4.1.3607.6.10.30.0.1500
Payload Bus Failure To IO Slot 15 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1510
Payload Bus Failure To IO Slot 16 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1520
Payload Bus Failure To IO Slot 17 (XCON Slot 8)
.1.3.6.1.4.1.3607.6.10.30.0.1530
Payload Bus Failure To IO Slot 1 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1540
Payload Bus Failure To IO Slot 2 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1550
Payload Bus Failure To IO Slot 3 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1560
Payload Bus Failure To IO Slot 4 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1570
Payload Bus Failure To IO Slot 5 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1580
Payload Bus Failure To IO Slot 6 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1590
Payload Bus Failure To IO Slot 12 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.160
Inconsistent APS code
.1.3.6.1.4.1.3607.6.10.30.0.1600
Payload Bus Failure To IO Slot 13 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1610
Payload Bus Failure To IO Slot 14 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1620
Payload Bus Failure To IO Slot 15 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1630
Payload Bus Failure To IO Slot 16 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1640
Payload Bus Failure To IO Slot 17 (XCON Slot 10)
.1.3.6.1.4.1.3607.6.10.30.0.1650
Time Slot Interchange Equipment Failure
.1.3.6.1.4.1.3607.6.10.30.0.1660
equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.1670
High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.1680
Invalid MAC Address
.1.3.6.1.4.1.3607.6.10.30.0.1690
Board Failure
.1.3.6.1.4.1.3607.6.10.30.0.170
Improper APS code
.1.3.6.1.4.1.3607.6.10.30.0.1700
equipment failure Diagnostics Failure
.1.3.6.1.4.1.3607.6.10.30.0.1710
Medium Access Control Failure
.1.3.6.1.4.1.3607.6.10.30.0.1720
facility Termination equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.1730
Automatic Laser Shutoff Due To High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.1740
failure To Release from protection
.1.3.6.1.4.1.3607.6.10.30.0.1750
Receiver Failure
.1.3.6.1.4.1.3607.6.10.30.0.1760
Transmit Failure
.1.3.6.1.4.1.3607.6.10.30.0.1770
facility Termination equipment Receiver missing
.1.3.6.1.4.1.3607.6.10.30.0.1780
facility Termination equipment Transmitter missing
.1.3.6.1.4.1.3607.6.10.30.0.1790
failure To Switch to protection
.1.3.6.1.4.1.3607.6.10.30.0.180
Node Id Mismatch APS
.1.3.6.1.4.1.3607.6.10.30.0.1800
failure To Switch to protection Ring
.1.3.6.1.4.1.3607.6.10.30.0.1810
failure To Switch to protection Span
.1.3.6.1.4.1.3607.6.10.30.0.1820
failure to Switch to protection Path
.1.3.6.1.4.1.3607.6.10.30.0.1830
Fan Failure
.1.3.6.1.4.1.3607.6.10.30.0.1840
equipment unit plug in
.1.3.6.1.4.1.3607.6.10.30.0.1850
NE Power Failure At Connector
.1.3.6.1.4.1.3607.6.10.30.0.1860
Fuse Alarm
.1.3.6.1.4.1.3607.6.10.30.0.1870
synchronization unit failure
.1.3.6.1.4.1.3607.6.10.30.0.1880
synchronization switching Equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.1890
Equipment Unit Un-plugged
.1.3.6.1.4.1.3607.6.10.30.0.190
channel Default K APS
.1.3.6.1.4.1.3607.6.10.30.0.1900
loop back
.1.3.6.1.4.1.3607.6.10.30.0.1910
DS1 Loopback Due To FEAC Command
.1.3.6.1.4.1.3607.6.10.30.0.1920
loopback Command sent to Far End DS1
.1.3.6.1.4.1.3607.6.10.30.0.1930
loopback due to FEAC command DS3
.1.3.6.1.4.1.3607.6.10.30.0.1940
DS3 Loopback Command Sent To Far End
.1.3.6.1.4.1.3607.6.10.30.0.1950
DS2 Loopback Due To Far End Command
.1.3.6.1.4.1.3607.6.10.30.0.1960
DS2 Loopback Command Sent To Far End
.1.3.6.1.4.1.3607.6.10.30.0.1970
Facility Loopback
.1.3.6.1.4.1.3607.6.10.30.0.1980
Network Loopback
.1.3.6.1.4.1.3607.6.10.30.0.1990
Terminal Loopback
.1.3.6.1.4.1.3607.6.10.30.0.20
failure detected External to the NE
.1.3.6.1.4.1.3607.6.10.30.0.200
Connection loss APS
.1.3.6.1.4.1.3607.6.10.30.0.2000
manually caused abnormal condition
.1.3.6.1.4.1.3607.6.10.30.0.2010
Ethernet Bridge Is New Root Of Spanning Tree
.1.3.6.1.4.1.3607.6.10.30.0.2020
Ethernet Bridge Topology Change
.1.3.6.1.4.1.3607.6.10.30.0.2030
normal condition
.1.3.6.1.4.1.3607.6.10.30.0.2040
embedded Operations Channel failure link down
.1.3.6.1.4.1.3607.6.10.30.0.2050
peer state mismatch
.1.3.6.1.4.1.3607.6.10.30.0.2060
procedural Error
.1.3.6.1.4.1.3607.6.10.30.0.2070
Improper Removal
.1.3.6.1.4.1.3607.6.10.30.0.2080
Duplicate Node ID
.1.3.6.1.4.1.3607.6.10.30.0.2090
BLSR out of sync
.1.3.6.1.4.1.3607.6.10.30.0.210
bipolar Violation
.1.3.6.1.4.1.3607.6.10.30.0.2100
BLSR Multi-Node Table Update Completed
.1.3.6.1.4.1.3607.6.10.30.0.2110
protection unit not available
.1.3.6.1.4.1.3607.6.10.30.0.2120
performance Monitor Threshold Crossing Alert
.1.3.6.1.4.1.3607.6.10.30.0.2130
Protection Switch
.1.3.6.1.4.1.3607.6.10.30.0.2140
recovery or service protection action has been initiated
.1.3.6.1.4.1.3607.6.10.30.0.2150
automatic system Reset
.1.3.6.1.4.1.3607.6.10.30.0.2160
automatic UPSR switch caused by AIS
.1.3.6.1.4.1.3607.6.10.30.0.2170
automatic UPSR switch caused by Lop
.1.3.6.1.4.1.3607.6.10.30.0.2180
Automatic UPSR Switch Caused By UNEQ
.1.3.6.1.4.1.3607.6.10.30.0.2190
automatic UPSR switch caused by PDI
.1.3.6.1.4.1.3607.6.10.30.0.220
carrier Loss on the LAN
.1.3.6.1.4.1.3607.6.10.30.0.2200
Automatic UPSR Switch Caused By SFBER
.1.3.6.1.4.1.3607.6.10.30.0.2210
Automatic UPSR Switch Caused By SDBER
.1.3.6.1.4.1.3607.6.10.30.0.2220
cold Restart
.1.3.6.1.4.1.3607.6.10.30.0.2230
Forced Switch Back To Working
.1.3.6.1.4.1.3607.6.10.30.0.2240
Forced Switch Back To Working - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2250
Forced Switch Back To Working - Span
.1.3.6.1.4.1.3607.6.10.30.0.2260
Forced Switch To Protection
.1.3.6.1.4.1.3607.6.10.30.0.2270
Forced Switch To Protection - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2280
Forced Switch To Protection - Span
.1.3.6.1.4.1.3607.6.10.30.0.2290
Working Facility or Equipment Forced To Switch To Protection - Path
.1.3.6.1.4.1.3607.6.10.30.0.230
concatenation error STS
.1.3.6.1.4.1.3607.6.10.30.0.2300
initialization initiated
.1.3.6.1.4.1.3607.6.10.30.0.2310
lockout of Protection
.1.3.6.1.4.1.3607.6.10.30.0.2320
lockout of Protection Ring
.1.3.6.1.4.1.3607.6.10.30.0.2330
lockout of Protection Span
.1.3.6.1.4.1.3607.6.10.30.0.2340
lockout of Protection Path
.1.3.6.1.4.1.3607.6.10.30.0.2350
lockout of working
.1.3.6.1.4.1.3607.6.10.30.0.2360
lockout of working Ring
.1.3.6.1.4.1.3607.6.10.30.0.2370
lockout of working Span
.1.3.6.1.4.1.3607.6.10.30.0.2380
manual system Reset
.1.3.6.1.4.1.3607.6.10.30.0.2390
Manual Switch to Internal Clock
.1.3.6.1.4.1.3607.6.10.30.0.240
excess collisions on the LAN
.1.3.6.1.4.1.3607.6.10.30.0.2400
Manual Switch To Primary Reference
.1.3.6.1.4.1.3607.6.10.30.0.2410
Manual Switch To Second Reference
.1.3.6.1.4.1.3607.6.10.30.0.2420
Manual Switch To Third reference
.1.3.6.1.4.1.3607.6.10.30.0.2430
Manual Switch To Fourth reference
.1.3.6.1.4.1.3607.6.10.30.0.2440
Manual Switch To Fifth reference
.1.3.6.1.4.1.3607.6.10.30.0.2450
Manual Switch To Sixth reference
.1.3.6.1.4.1.3607.6.10.30.0.2460
Manual Switch Back To Working
.1.3.6.1.4.1.3607.6.10.30.0.2470
Manual Switch Back To Working - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2480
Manual Switch Back To Working - Span
.1.3.6.1.4.1.3607.6.10.30.0.2490
Manual Switch To Protection
.1.3.6.1.4.1.3607.6.10.30.0.250
Facility Failure
.1.3.6.1.4.1.3607.6.10.30.0.2500
Manual Switch To Protection - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2510
Manual Switch To Protection - Span
.1.3.6.1.4.1.3607.6.10.30.0.2520
Manual Switch Of Working Facility or Equipment To Protection - Path
.1.3.6.1.4.1.3607.6.10.30.0.2530
Powerfail Restart
.1.3.6.1.4.1.3607.6.10.30.0.2540
ring is squelching traffic
.1.3.6.1.4.1.3607.6.10.30.0.2550
software download in progress
.1.3.6.1.4.1.3607.6.10.30.0.2560
Switch To Internal clock
.1.3.6.1.4.1.3607.6.10.30.0.2570
Switch To Primary refernce
.1.3.6.1.4.1.3607.6.10.30.0.2580
Switch To Second Reference
.1.3.6.1.4.1.3607.6.10.30.0.2590
Switch To Third refernce
.1.3.6.1.4.1.3607.6.10.30.0.260
far end AIS
.1.3.6.1.4.1.3607.6.10.30.0.2600
Switch To Fourth refernce
.1.3.6.1.4.1.3607.6.10.30.0.2610
Switch To Fifth refernce
.1.3.6.1.4.1.3607.6.10.30.0.2620
Switch To Sixth refernce
.1.3.6.1.4.1.3607.6.10.30.0.2630
system reboot
.1.3.6.1.4.1.3607.6.10.30.0.2640
Switched Back To Working
.1.3.6.1.4.1.3607.6.10.30.0.2650
Switched To Protection
.1.3.6.1.4.1.3607.6.10.30.0.2660
warm Restart
.1.3.6.1.4.1.3607.6.10.30.0.2670
Ring is in Wait To Restore state
.1.3.6.1.4.1.3607.6.10.30.0.2680
Manual Switch Request
.1.3.6.1.4.1.3607.6.10.30.0.2690
Forced Switch Request
.1.3.6.1.4.1.3607.6.10.30.0.270
far end Multiple DS1 LOS detected on DS3
.1.3.6.1.4.1.3607.6.10.30.0.2700
Lockout Switch Request
.1.3.6.1.4.1.3607.6.10.30.0.2710
RMON Histories And Alarms Reset Reboot
.1.3.6.1.4.1.3607.6.10.30.0.2720
Crossing of Falling/Rising Threshold detected
.1.3.6.1.4.1.3607.6.10.30.0.2730
Alarms Suppressed By User Command
.1.3.6.1.4.1.3607.6.10.30.0.2740
Alarms Suppressed For Maintenance
.1.3.6.1.4.1.3607.6.10.30.0.2750
Switching Matrix Module Failure
.1.3.6.1.4.1.3607.6.10.30.0.2760
Lan Connection Polarity Reversed
.1.3.6.1.4.1.3607.6.10.30.0.2780
Autonomous PM Report Message Inhibited
.1.3.6.1.4.1.3607.6.10.30.0.2790
IO Slot To XCON Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.280
far end DS1 eqpt fail non service affecting
.1.3.6.1.4.1.3607.6.10.30.0.2800
STS Path Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.2810
NE Power Failure At Connector A
.1.3.6.1.4.1.3607.6.10.30.0.2820
NE Power Failure At Connector B
.1.3.6.1.4.1.3607.6.10.30.0.2830
Free memory on the card is very low
.1.3.6.1.4.1.3607.6.10.30.0.2840
Free memory on the card is near zero
.1.3.6.1.4.1.3607.6.10.30.0.2850
Exercise Request on Ring
.1.3.6.1.4.1.3607.6.10.30.0.2860
Exercise Request on Span
.1.3.6.1.4.1.3607.6.10.30.0.2870
Squelching Path
.1.3.6.1.4.1.3607.6.10.30.0.2880
Extra Traffic Preempted.
.1.3.6.1.4.1.3607.6.10.30.0.2890
Far End Lockout of working - Ring.
.1.3.6.1.4.1.3607.6.10.30.0.290
far end DS1 Eqpt fail service affecting
.1.3.6.1.4.1.3607.6.10.30.0.2900
Far End Lockout of working - Span.
.1.3.6.1.4.1.3607.6.10.30.0.2910
Far End Lockout of Protection - Ring.
.1.3.6.1.4.1.3607.6.10.30.0.2920
Far End Lockout of Protection - All Spans.
.1.3.6.1.4.1.3607.6.10.30.0.2930
Far End Working Facility Forced To Switch To Protection - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2940
Far End Working Facility Forced To Switch To Protection - Span
.1.3.6.1.4.1.3607.6.10.30.0.2950
Far End Manual Switch Of Working Facility To Protection - Ring
.1.3.6.1.4.1.3607.6.10.30.0.2960
Far End Manual Switch Of Working Facility To Protection - Span
.1.3.6.1.4.1.3607.6.10.30.0.2970
Far End Exercising Ring
.1.3.6.1.4.1.3607.6.10.30.0.2980
Far End Exercising Span
.1.3.6.1.4.1.3607.6.10.30.0.2990
Far End BER threshold passed for Signal Failure - Ring.
.1.3.6.1.4.1.3607.6.10.30.0.30
external error
.1.3.6.1.4.1.3607.6.10.30.0.300
far end Single DS1 LOS
.1.3.6.1.4.1.3607.6.10.30.0.3000
Far End BER threshold passed for Signal Failure - Span.
.1.3.6.1.4.1.3607.6.10.30.0.3010
Far End BER threshold passed for Signal Degrade - Ring.
.1.3.6.1.4.1.3607.6.10.30.0.3020
Far End BER threshold passed for Signal Degrade - Span.
.1.3.6.1.4.1.3607.6.10.30.0.3030
APS Channel - Far End Protection Line Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.3040
Ring Switch is active on the East Side.
.1.3.6.1.4.1.3607.6.10.30.0.3050
Ring Switch is active on the West Side.
.1.3.6.1.4.1.3607.6.10.30.0.3060
Span Switch is active on the East Side.
.1.3.6.1.4.1.3607.6.10.30.0.3070
Span Switch is active on the West Side.
.1.3.6.1.4.1.3607.6.10.30.0.3080
Uni-directional Full Pass Through is active.
.1.3.6.1.4.1.3607.6.10.30.0.3090
Bi-directional Full Pass Through is active.
.1.3.6.1.4.1.3607.6.10.30.0.310
far end DS3 Eqpt failure non service affecting
.1.3.6.1.4.1.3607.6.10.30.0.3100
K Bytes Pass Through Is Active
.1.3.6.1.4.1.3607.6.10.30.0.3110
Ring is Segmented.
.1.3.6.1.4.1.3607.6.10.30.0.3120
Ring Topology is under construction.
.1.3.6.1.4.1.3607.6.10.30.0.3130
Lockout of Protection - All Spans.
.1.3.6.1.4.1.3607.6.10.30.0.3140
Far end of fiber is provisioned with different ring ID
.1.3.6.1.4.1.3607.6.10.30.0.3150
Both ends of fiber provisioned as East, or both as West
.1.3.6.1.4.1.3607.6.10.30.0.3160
Security: invalid login (see Audit Trail)
.1.3.6.1.4.1.3607.6.10.30.0.3170
Autonomous messages inhibited
.1.3.6.1.4.1.3607.6.10.30.0.3180
Traffic Storm On LAN. LAN Temporarily Disabled
.1.3.6.1.4.1.3607.6.10.30.0.3190
REPT^DBCHG Messages Inhibited
.1.3.6.1.4.1.3607.6.10.30.0.320
far end DS3 Eqpt failure service affecting
.1.3.6.1.4.1.3607.6.10.30.0.3200
Security: User ID Has Expired
.1.3.6.1.4.1.3607.6.10.30.0.3210
Partial Fan Failure
.1.3.6.1.4.1.3607.6.10.30.0.3220
Forced Switch Request On Ring
.1.3.6.1.4.1.3607.6.10.30.0.3230
Forced Switch Request On Span
.1.3.6.1.4.1.3607.6.10.30.0.3240
Lockout switch request on Ring
.1.3.6.1.4.1.3607.6.10.30.0.3250
Lockout switch request on Span
.1.3.6.1.4.1.3607.6.10.30.0.3260
Manual switch request on Ring
.1.3.6.1.4.1.3607.6.10.30.0.3270
Manual switch request on Span
.1.3.6.1.4.1.3607.6.10.30.0.3280
Peer to Peer Slot communication failure - Control Bus A
.1.3.6.1.4.1.3607.6.10.30.0.3290
Peer to Peer Slot communication failure - Control Bus B
.1.3.6.1.4.1.3607.6.10.30.0.330
far end common Eqpt failure non service affecting
.1.3.6.1.4.1.3607.6.10.30.0.3300
Controller A to shelf slot communication failure
.1.3.6.1.4.1.3607.6.10.30.0.3310
Controller B to shelf slot communication failure
.1.3.6.1.4.1.3607.6.10.30.0.3320
Interconnection Equipment Failure - Working Payload Bus
.1.3.6.1.4.1.3607.6.10.30.0.3330
Interconnection Equipment Failure - Protect Payload Bus
.1.3.6.1.4.1.3607.6.10.30.0.3340
Inhibit Switch to Protect Request on equipment
.1.3.6.1.4.1.3607.6.10.30.0.3350
Inhibit Switch to Working Request on equipment
.1.3.6.1.4.1.3607.6.10.30.0.3360
BER Threshold exceeded for Signal Degrade - Line
.1.3.6.1.4.1.3607.6.10.30.0.3370
BER Threshold exceeded for Signal Degrade - Path
.1.3.6.1.4.1.3607.6.10.30.0.3380
BER Threshold Exceeded For Signal Failure - Line
.1.3.6.1.4.1.3607.6.10.30.0.3390
BER Threshold Exceeded For Signal Failure - Path
.1.3.6.1.4.1.3607.6.10.30.0.340
far end IDLE
.1.3.6.1.4.1.3607.6.10.30.0.3400
Exercising Ring Successfully
.1.3.6.1.4.1.3607.6.10.30.0.3410
Exercising Span Successfully
.1.3.6.1.4.1.3607.6.10.30.0.3420
Span is in Wait To Restore state
.1.3.6.1.4.1.3607.6.10.30.0.3430
Exercise Request on Ring Failed
.1.3.6.1.4.1.3607.6.10.30.0.3440
Exercise Request on Span Failed
.1.3.6.1.4.1.3607.6.10.30.0.3450
Far End Lockout Of Protection - Span
.1.3.6.1.4.1.3607.6.10.30.0.3460
Manufacturing Data Memory (EEPROM) Failure
.1.3.6.1.4.1.3607.6.10.30.0.3470
Replaceable Equipment/Unit is Missing
.1.3.6.1.4.1.3607.6.10.30.0.3480
Software Download Failed
.1.3.6.1.4.1.3607.6.10.30.0.3490
Extra Traffic (PCA) Dropped
.1.3.6.1.4.1.3607.6.10.30.0.350
far end LOS
.1.3.6.1.4.1.3607.6.10.30.0.3500
Ether tx oversubscribed
.1.3.6.1.4.1.3607.6.10.30.0.3510
Ether rx over subscribed
.1.3.6.1.4.1.3607.6.10.30.0.3520
Ether tx excess flow ctrl
.1.3.6.1.4.1.3607.6.10.30.0.3530
Ether rx excess flow ctrl
.1.3.6.1.4.1.3607.6.10.30.0.3540
transport layer failure
.1.3.6.1.4.1.3607.6.10.30.0.3550
Ether tx underrun
.1.3.6.1.4.1.3607.6.10.30.0.3560
Synchronization reference frequency out of bounds.
.1.3.6.1.4.1.3607.6.10.30.0.3570
NTP/SNTP Host Failure.
.1.3.6.1.4.1.3607.6.10.30.0.3580
Peer Card Not Responding
.1.3.6.1.4.1.3607.6.10.30.0.3590
Alarms and events suppressed for this object
.1.3.6.1.4.1.3607.6.10.30.0.360
far end LOF
.1.3.6.1.4.1.3607.6.10.30.0.3600
DS3 Frame Format Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.3610
Wait To Restore
.1.3.6.1.4.1.3607.6.10.30.0.3620
Extreme High Volt Battery A
.1.3.6.1.4.1.3607.6.10.30.0.3630
Extreme Low Volt Battery A
.1.3.6.1.4.1.3607.6.10.30.0.3640
Extreme High Volt Battery B
.1.3.6.1.4.1.3607.6.10.30.0.3650
Extreme Low Volt Battery B
.1.3.6.1.4.1.3607.6.10.30.0.3660
IOS config copy failed
.1.3.6.1.4.1.3607.6.10.30.0.3670
IOS config copy in progress
.1.3.6.1.4.1.3607.6.10.30.0.3680
IOS Config Copy Success
.1.3.6.1.4.1.3607.6.10.30.0.370
far End Block Error
.1.3.6.1.4.1.3607.6.10.30.0.3710
Signaling Unable to setup circuit
.1.3.6.1.4.1.3607.6.10.30.0.3712
Error in Startup Config
.1.3.6.1.4.1.3607.6.10.30.0.3714
No Startup Config
.1.3.6.1.4.1.3607.6.10.30.0.3716
Need to Save Running Config
.1.3.6.1.4.1.3607.6.10.30.0.3718
Invalid Alarm
.1.3.6.1.4.1.3607.6.10.30.0.3720
RSVP Hello FSM to Neighbor down
.1.3.6.1.4.1.3607.6.10.30.0.3722
Security: Invalid Login - Username - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.3724
Database Backup Failed
.1.3.6.1.4.1.3607.6.10.30.0.3726
Database Restore Failed
.1.3.6.1.4.1.3607.6.10.30.0.3730
LMP Hello FSM to Control Channel down
.1.3.6.1.4.1.3607.6.10.30.0.3740
LMP Neighbor Discovery has failed
.1.3.6.1.4.1.3607.6.10.30.0.3750
Unauthorized incoming signaling request
.1.3.6.1.4.1.3607.6.10.30.0.3760
Audit Log 80 Percent Full
.1.3.6.1.4.1.3607.6.10.30.0.3762
Module Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.3764
Audit Log 100 Percent Full - Oldest records will be lost
.1.3.6.1.4.1.3607.6.10.30.0.3766
Standby Database Out of Sync
.1.3.6.1.4.1.3607.6.10.30.0.3768
Redundant Power Capability Lost
.1.3.6.1.4.1.3607.6.10.30.0.3770
Forced Switch To Primary Reference
.1.3.6.1.4.1.3607.6.10.30.0.3780
Forced Switch To Second Reference
.1.3.6.1.4.1.3607.6.10.30.0.3790
Forced Switch To Third Reference
.1.3.6.1.4.1.3607.6.10.30.0.380
idle Condition DS3
.1.3.6.1.4.1.3607.6.10.30.0.3800
Forced Switch To Internal Clock
.1.3.6.1.4.1.3607.6.10.30.0.3805
Industrial High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.390
loss of Frame
.1.3.6.1.4.1.3607.6.10.30.0.40
excessive switching
.1.3.6.1.4.1.3607.6.10.30.0.400
loss of Pointer
.1.3.6.1.4.1.3607.6.10.30.0.4000
TIM Section - Trace Identifier Mismatch Failure.
.1.3.6.1.4.1.3607.6.10.30.0.4010
AIS - Multiplex Section - Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.4020
RDI - Multiplex Section - Remote Defect/Alarm Indication
.1.3.6.1.4.1.3607.6.10.30.0.4030
TIM High Order - Trace Identifier Mismatch Failure
.1.3.6.1.4.1.3607.6.10.30.0.4040
AIS - Administration Unit - Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.4050
LOP - Administration Unit - Loss of Pointer
.1.3.6.1.4.1.3607.6.10.30.0.4060
SLMF - Unequipped High Order - Path Unequipped
.1.3.6.1.4.1.3607.6.10.30.0.4070
SLMF - PLM High Order - Path Label Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4080
RDI - High Order - Remote Defect/Alarm Indication
.1.3.6.1.4.1.3607.6.10.30.0.4090
LOP - Tributary Unit - Loss of Pointer
.1.3.6.1.4.1.3607.6.10.30.0.410
loss of Pointer Path
.1.3.6.1.4.1.3607.6.10.30.0.4100
AIS - Tributary Unit - Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.4110
SLMF - Unequipped Low Order - Path Unequipped
.1.3.6.1.4.1.3607.6.10.30.0.4120
SLMF - PLM Low Order - Path Label Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4130
TIM Low Order - Trace Identifier Mismatch Failure
.1.3.6.1.4.1.3607.6.10.30.0.4140
RFI - Low Order - Remote Failure/Alarm Indication
.1.3.6.1.4.1.3607.6.10.30.0.4150
G811 - Primary Reference Clock traceable.
.1.3.6.1.4.1.3607.6.10.30.0.4160
G812 - Transit Node Clock traceable.
.1.3.6.1.4.1.3607.6.10.30.0.4170
G812 - Local Node Clock traceable.
.1.3.6.1.4.1.3607.6.10.30.0.4180
G813 - Synchronous Equipment Timing Source traceable
.1.3.6.1.4.1.3607.6.10.30.0.4190
E1 loopback due to FEAC command
.1.3.6.1.4.1.3607.6.10.30.0.420
loss of Pointer VT
.1.3.6.1.4.1.3607.6.10.30.0.4200
E1 loopback command sent to Far End
.1.3.6.1.4.1.3607.6.10.30.0.4210
E3 loopback due to FEAC command
.1.3.6.1.4.1.3607.6.10.30.0.4220
far end Multiple E1 LOS detected on E3
.1.3.6.1.4.1.3607.6.10.30.0.4230
far end E1 eqpt fail non service affecting
.1.3.6.1.4.1.3607.6.10.30.0.4240
far end E1 eqpt fail service affecting
.1.3.6.1.4.1.3607.6.10.30.0.4250
far end Single E1 LOS
.1.3.6.1.4.1.3607.6.10.30.0.4260
far end E3 eqpt fail service affecting
.1.3.6.1.4.1.3607.6.10.30.0.4270
E3 loopback command sent to far end
.1.3.6.1.4.1.3607.6.10.30.0.4280
far end E3 eqpt fail non service affecting
.1.3.6.1.4.1.3607.6.10.30.0.4290
Low Volt - Battery A
.1.3.6.1.4.1.3607.6.10.30.0.430
loss of Signal
.1.3.6.1.4.1.3607.6.10.30.0.4300
High Volt - Battery A
.1.3.6.1.4.1.3607.6.10.30.0.4310
Low Volt - Battery B
.1.3.6.1.4.1.3607.6.10.30.0.4320
High Volt - Battery B
.1.3.6.1.4.1.3607.6.10.30.0.4330
MS-SP ring out of sync
.1.3.6.1.4.1.3607.6.10.30.0.4340
MSSP Multi-Node Table Update Completed
.1.3.6.1.4.1.3607.6.10.30.0.4350
automatic SNCP switch caused by AIS
.1.3.6.1.4.1.3607.6.10.30.0.4360
automatic SNCP switch caused by Lop
.1.3.6.1.4.1.3607.6.10.30.0.4370
Automatic SNCP Switch caused by UNEQ
.1.3.6.1.4.1.3607.6.10.30.0.4380
automatic SNCP switch caused by PDI
.1.3.6.1.4.1.3607.6.10.30.0.4390
Automatic SNCP Switch caused by SFBER
.1.3.6.1.4.1.3607.6.10.30.0.440
out of Frame
.1.3.6.1.4.1.3607.6.10.30.0.4400
Automatic SNCP Switch caused by SDBER
.1.3.6.1.4.1.3607.6.10.30.0.4410
STM Concatenation error
.1.3.6.1.4.1.3607.6.10.30.0.4420
E3 Idle Condition
.1.3.6.1.4.1.3607.6.10.30.0.4430
channel MSSP inconsistent APS code
.1.3.6.1.4.1.3607.6.10.30.0.4440
channel MSSP Improper APS code APS
.1.3.6.1.4.1.3607.6.10.30.0.4450
channel MSSP Node Id Mismatch APS
.1.3.6.1.4.1.3607.6.10.30.0.4460
channel MSSP Default K APS
.1.3.6.1.4.1.3607.6.10.30.0.4470
channel MSSP Connection loss APS
.1.3.6.1.4.1.3607.6.10.30.0.4480
SDH Minimum clock Traceable
.1.3.6.1.4.1.3607.6.10.30.0.4490
SDH line is in Wait To Restore state
.1.3.6.1.4.1.3607.6.10.30.0.450
Path Selector Failure
.1.3.6.1.4.1.3607.6.10.30.0.4500
BER Threshold Exceeded For Signal Degrade - High Order
.1.3.6.1.4.1.3607.6.10.30.0.4510
BER Threshold Exceeded For Signal Failure - High Order
.1.3.6.1.4.1.3607.6.10.30.0.4520
BER Threshold Exceeded For Signal Degrade - Low Order
.1.3.6.1.4.1.3607.6.10.30.0.4530
BER Threshold Exceeded For Signal Failure - Low Order
.1.3.6.1.4.1.3607.6.10.30.0.4540
Failure To Switch To Protection - High Order Path
.1.3.6.1.4.1.3607.6.10.30.0.4550
Failure To Switch To Protection - Low Order Path
.1.3.6.1.4.1.3607.6.10.30.0.4560
LOF - Administration Unit - Loss of Multi Frame
.1.3.6.1.4.1.3607.6.10.30.0.4570
SDH span is in Wait To Restore state
.1.3.6.1.4.1.3607.6.10.30.0.460
remote Alarm Indication
.1.3.6.1.4.1.3607.6.10.30.0.470
remote Failure Indication
.1.3.6.1.4.1.3607.6.10.30.0.4755
8B10B Out of Sync
.1.3.6.1.4.1.3607.6.10.30.0.4760
ODUk: PM Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.4765
OTUk: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.4770
OTUk: Backward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.4775
ODUk: Backward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.4780
FEC Uncorrected Word
.1.3.6.1.4.1.3607.6.10.30.0.4785
GCC Termination Failure
.1.3.6.1.4.1.3607.6.10.30.0.4790
OTUk: Incoming Alignment Error
.1.3.6.1.4.1.3607.6.10.30.0.4795
ODUk: Locked Defect - PM
.1.3.6.1.4.1.3607.6.10.30.0.480
remote Failure Indication LINE
.1.3.6.1.4.1.3607.6.10.30.0.4800
Loss of Multi-Frame
.1.3.6.1.4.1.3607.6.10.30.0.4805
ODUk: Open Connection Indication
.1.3.6.1.4.1.3607.6.10.30.0.4810
Payload Type Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4815
ODUk: Trail Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4820
OTUk: Trail Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4825
Equipment High Laser Bias
.1.3.6.1.4.1.3607.6.10.30.0.4830
Equipment High Laser Temp
.1.3.6.1.4.1.3607.6.10.30.0.4835
Equipment High Laser Peltier
.1.3.6.1.4.1.3607.6.10.30.0.4840
Facility High Rx power
.1.3.6.1.4.1.3607.6.10.30.0.4845
Equipment High Tx power
.1.3.6.1.4.1.3607.6.10.30.0.4850
Equipment High Transceiver voltage
.1.3.6.1.4.1.3607.6.10.30.0.4855
Equipment Low Laser Bias
.1.3.6.1.4.1.3607.6.10.30.0.4860
Equipment Low Laser Temp
.1.3.6.1.4.1.3607.6.10.30.0.4865
Equipment Low Laser Peltier
.1.3.6.1.4.1.3607.6.10.30.0.4870
Facility Low Rx power
.1.3.6.1.4.1.3607.6.10.30.0.4875
Equipment Low Tx power
.1.3.6.1.4.1.3607.6.10.30.0.4880
Equipment Low Transceiver voltage
.1.3.6.1.4.1.3607.6.10.30.0.4885
Equipment Rx Locked
.1.3.6.1.4.1.3607.6.10.30.0.4890
Equipment Squelched
.1.3.6.1.4.1.3607.6.10.30.0.4895
Equipment Tx Locked
.1.3.6.1.4.1.3607.6.10.30.0.490
remote Failure Indication Path
.1.3.6.1.4.1.3607.6.10.30.0.4900
OTUK Signal Failure
.1.3.6.1.4.1.3607.6.10.30.0.4905
ODUK Signal Failure
.1.3.6.1.4.1.3607.6.10.30.0.4910
OTUK Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.4915
ODUK Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.4920
Pluggable Port missing
.1.3.6.1.4.1.3607.6.10.30.0.4925
Pluggable Port rate mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4930
Pluggable Port security code mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4935
Tci not selected
.1.3.6.1.4.1.3607.6.10.30.0.4940
Tci 1 Clock Failure
.1.3.6.1.4.1.3607.6.10.30.0.4945
ODUk: PM Backward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.4950
ODUk: TCM1 Backward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.4955
ODUk: TCM2 Backward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.4960
Equipment High Rx temperature
.1.3.6.1.4.1.3607.6.10.30.0.4965
Equipment Low Rx temperature
.1.3.6.1.4.1.3607.6.10.30.0.4970
Tci 2 Clock Failure
.1.3.6.1.4.1.3607.6.10.30.0.4975
Equipment Wavelength Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.4980
DSP Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.4985
DSP Failure
.1.3.6.1.4.1.3607.6.10.30.0.50
SDCC Termination failure
.1.3.6.1.4.1.3607.6.10.30.0.500
remote Failure Indication VT
.1.3.6.1.4.1.3607.6.10.30.0.5000
Laser Approaching End of Life
.1.3.6.1.4.1.3607.6.10.30.0.5010
Cross-connect Loopback
.1.3.6.1.4.1.3607.6.10.30.0.5020
Admin Logout of User
.1.3.6.1.4.1.3607.6.10.30.0.5030
User Locked Out
.1.3.6.1.4.1.3607.6.10.30.0.5040
Admin Lockout of User
.1.3.6.1.4.1.3607.6.10.30.0.5050
Admin Lockout Clear
.1.3.6.1.4.1.3607.6.10.30.0.5060
Invalid Login: Username
.1.3.6.1.4.1.3607.6.10.30.0.5070
Security: Invalid Login - Password - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.5080
Security: Invalid Login - Locked Out - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.5090
Security: Invalid Login - Already Logged On - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.510
facility has passed BER Threshold for Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.5100
Login of User
.1.3.6.1.4.1.3607.6.10.30.0.5110
Automatic Logout of IdleUser
.1.3.6.1.4.1.3607.6.10.30.0.5120
Logout of User
.1.3.6.1.4.1.3607.6.10.30.0.520
severely Errored Frame
.1.3.6.1.4.1.3607.6.10.30.0.5200
Enhanced Remote Failure Indication - Path - Server
.1.3.6.1.4.1.3607.6.10.30.0.5210
Enhanced Remote Failure Indication - Path - Connectivity
.1.3.6.1.4.1.3607.6.10.30.0.5220
Enhanced Remote Failure Indication - Path - Payload
.1.3.6.1.4.1.3607.6.10.30.0.5230
Firewall Has Been Disabled
.1.3.6.1.4.1.3607.6.10.30.0.5240
Security Intrusion Attempt Detected - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.5250
Security Intrusion Attempt Detected - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.5260
Connection Equipment Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.5270
Disable Inactive User
.1.3.6.1.4.1.3607.6.10.30.0.5280
Disable Inactive Clear
.1.3.6.1.4.1.3607.6.10.30.0.5290
Battery Failure
.1.3.6.1.4.1.3607.6.10.30.0.530
facility has passed BER threshold for Signal Failure
.1.3.6.1.4.1.3607.6.10.30.0.5300
Extreme High Volt
.1.3.6.1.4.1.3607.6.10.30.0.5310
Extreme Low Volt
.1.3.6.1.4.1.3607.6.10.30.0.5320
High Volt
.1.3.6.1.4.1.3607.6.10.30.0.5330
Low Volt
.1.3.6.1.4.1.3607.6.10.30.0.5340
Suspend User
.1.3.6.1.4.1.3607.6.10.30.0.5350
Suspend User Clear
.1.3.6.1.4.1.3607.6.10.30.0.5360
Line DCC Termination Failure
.1.3.6.1.4.1.3607.6.10.30.0.5370
Multiplex Section DCC Termination Failure
.1.3.6.1.4.1.3607.6.10.30.0.5380
GigaBit Ethernet Out of Sync
.1.3.6.1.4.1.3607.6.10.30.0.5390
Sequence Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.540
signal Label Mismatch Failure
.1.3.6.1.4.1.3607.6.10.30.0.5400
Loss of Alignment
.1.3.6.1.4.1.3607.6.10.30.0.5410
Out of Use - Administrative Command
.1.3.6.1.4.1.3607.6.10.30.0.5420
Out of Use - Transport Failure
.1.3.6.1.4.1.3607.6.10.30.0.5430
VCAT Group Down
.1.3.6.1.4.1.3607.6.10.30.0.5440
VCAT Group Degraded
.1.3.6.1.4.1.3607.6.10.30.0.5450
VCAT Group Incomplete
.1.3.6.1.4.1.3607.6.10.30.0.5460
Alarm Indication Signal in TX
.1.3.6.1.4.1.3607.6.10.30.0.5470
Remote Alarm Indication in TX
.1.3.6.1.4.1.3607.6.10.30.0.5480
Kbyte Channel Failure
.1.3.6.1.4.1.3607.6.10.30.0.5490
APS Invalid Mode
.1.3.6.1.4.1.3607.6.10.30.0.550
Payload Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.5500
IP Address A1ready In Use Within The Same DCC Area
.1.3.6.1.4.1.3607.6.10.30.0.5510
Node name already in use within the same DCC Area
.1.3.6.1.4.1.3607.6.10.30.0.5520
Rear Panel Ethernet Link Removed
.1.3.6.1.4.1.3607.6.10.30.0.5530
Manual Switch To Protect Resulted in No Traffic Switch
.1.3.6.1.4.1.3607.6.10.30.0.5540
Manual Switch Back To Working Resulted in No Traffic Switch
.1.3.6.1.4.1.3607.6.10.30.0.5550
Forced Switch To Protection Resulted in No Traffic Switch
.1.3.6.1.4.1.3607.6.10.30.0.5560
Forced Switch Back To Working Resulted in No Traffic Switch
.1.3.6.1.4.1.3607.6.10.30.0.5570
Duplicate Serial number detected on a pluggable entity
.1.3.6.1.4.1.3607.6.10.30.0.560
Payload Defect Indication - Path
.1.3.6.1.4.1.3607.6.10.30.0.5600
Incoming Payload Signal Absent
.1.3.6.1.4.1.3607.6.10.30.0.5610
Encapsulation Mismatch Path
.1.3.6.1.4.1.3607.6.10.30.0.5620
Encapsulation Mismatch - VT
.1.3.6.1.4.1.3607.6.10.30.0.5630
Encapsulation Mismatch High Order - Path
.1.3.6.1.4.1.3607.6.10.30.0.5640
Encapsulation Mismatch Low Order - Path
.1.3.6.1.4.1.3607.6.10.30.0.5650
GFP User Payload Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.5660
GFP Fibre Channel Distance Extension Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.5670
GFP Fibre Channel Distance Extension Buffer Starvation
.1.3.6.1.4.1.3607.6.10.30.0.5680
Fibre Channel Distance Extension Credit Starvation
.1.3.6.1.4.1.3607.6.10.30.0.5690
Automatic WDM ANS Finished
.1.3.6.1.4.1.3607.6.10.30.0.570
Payload Label Mismatch - Path
.1.3.6.1.4.1.3607.6.10.30.0.5700
GFP Client Signal Fail Detected
.1.3.6.1.4.1.3607.6.10.30.0.5710
GFP Loss of Frame Delineation
.1.3.6.1.4.1.3607.6.10.30.0.5730
GFP Extension Header Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.5740
Incoming Overhead Signal Absent
.1.3.6.1.4.1.3607.6.10.30.0.5750
Optical Safety Remote Interlock On
.1.3.6.1.4.1.3607.6.10.30.0.5770
Automatic Power Control Correction Skipped
.1.3.6.1.4.1.3607.6.10.30.0.5780
APC cannot set value due to range limits
.1.3.6.1.4.1.3607.6.10.30.0.5790
LCAS VCG Member Tx Side In ADD State
.1.3.6.1.4.1.3607.6.10.30.0.580
signal Label Mismatch Failure Payload Label Mismatch VT
.1.3.6.1.4.1.3607.6.10.30.0.5800
Far End Manual Switch Back to Working - Span
.1.3.6.1.4.1.3607.6.10.30.0.5810
Far End Forced Switch Back to Working - Span
.1.3.6.1.4.1.3607.6.10.30.0.5820
Universal Transponder Module Hardware Failure
.1.3.6.1.4.1.3607.6.10.30.0.5830
Universal Transponder Module Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.5840
Plug-in Module Range Settings Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.5850
LCAS VCG Member Tx Side In DNU State
.1.3.6.1.4.1.3607.6.10.30.0.5860
LCAS Control Word CRC Check Failure
.1.3.6.1.4.1.3607.6.10.30.0.5870
LCAS VCG Member Rx Side In FAIL State
.1.3.6.1.4.1.3607.6.10.30.0.5880
Signal Loss on Data Interface
.1.3.6.1.4.1.3607.6.10.30.0.5890
Synchronization Loss on Data Interface
.1.3.6.1.4.1.3607.6.10.30.0.590
Unequipped - Path
.1.3.6.1.4.1.3607.6.10.30.0.5900
PORT FAIL
.1.3.6.1.4.1.3607.6.10.30.0.5910
Unreachable port target power
.1.3.6.1.4.1.3607.6.10.30.0.5920
Port Add Power Degrade Low
.1.3.6.1.4.1.3607.6.10.30.0.5930
Port Add Power Degrade High
.1.3.6.1.4.1.3607.6.10.30.0.5940
Port Add Power Fail Low
.1.3.6.1.4.1.3607.6.10.30.0.5950
Port Add Power Fail High
.1.3.6.1.4.1.3607.6.10.30.0.60
incoming failure condition
.1.3.6.1.4.1.3607.6.10.30.0.600
signal Label Mismatch Failure Unequipped VT
.1.3.6.1.4.1.3607.6.10.30.0.6000
Automatic Power Control Terminated on Manual request
.1.3.6.1.4.1.3607.6.10.30.0.6010
ODUk-1: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.6020
ODUk-2: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.6030
ODUk-3: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.6040
ODUk-4: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.6050
Temperature Reading Mismatch Between SC Cards
.1.3.6.1.4.1.3607.6.10.30.0.6060
Voltage Reading Mismatch Between SC Cards
.1.3.6.1.4.1.3607.6.10.30.0.6070
Alarms Suppressed on Out-Of-Group VCAT Member
.1.3.6.1.4.1.3607.6.10.30.0.6080
BLSR Software Version Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6090
Optimized 1+1 APS Primary Facility
.1.3.6.1.4.1.3607.6.10.30.0.610
Loss of Synchronization
.1.3.6.1.4.1.3607.6.10.30.0.6100
Optimized 1+1 APS Primary Section Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6110
Optimized 1+1 APS Invalid Primary Section
.1.3.6.1.4.1.3607.6.10.30.0.6120
Composite Clock High Line Voltage
.1.3.6.1.4.1.3607.6.10.30.0.6130
BER Threshold Exceeded For Signal Degrade - VT
.1.3.6.1.4.1.3607.6.10.30.0.6140
BER Threshold Exceeded For Signal Failure - VT
.1.3.6.1.4.1.3607.6.10.30.0.6150
Span Length Out of Range
.1.3.6.1.4.1.3607.6.10.30.0.6170
Idle Signal Condition
.1.3.6.1.4.1.3607.6.10.30.0.6180
Idle Signal Condition in TX
.1.3.6.1.4.1.3607.6.10.30.0.6190
VT Path Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.620
Out of Synchronization
.1.3.6.1.4.1.3607.6.10.30.0.6200
Loss of Frame in TX
.1.3.6.1.4.1.3607.6.10.30.0.6210
Provisioning Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6220
Section Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6230
Regenerator Section Trace Identifier Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6240
Switching Matrix Module Failure - Working
.1.3.6.1.4.1.3607.6.10.30.0.6250
Switching Matrix Module Failure - Protect
.1.3.6.1.4.1.3607.6.10.30.0.6260
Slot Communication Disabled
.1.3.6.1.4.1.3607.6.10.30.0.6270
Session Time Limit Expired
.1.3.6.1.4.1.3607.6.10.30.0.6280
User Password Change Required
.1.3.6.1.4.1.3607.6.10.30.0.6290
ISIS Adjacency Failure
.1.3.6.1.4.1.3607.6.10.30.0.630
Primary Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6300
MSSP Software Version Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6310
Remote Authentication Fail - See Audit Log
.1.3.6.1.4.1.3607.6.10.30.0.6330
Ring Is Squelching STS Traffic
.1.3.6.1.4.1.3607.6.10.30.0.6340
Ring Is Squelching VT Traffic
.1.3.6.1.4.1.3607.6.10.30.0.6350
Archival of Audit Log Failed
.1.3.6.1.4.1.3607.6.10.30.0.6360
RPR Wrapped
.1.3.6.1.4.1.3607.6.10.30.0.6370
Shelf Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.6380
Duplicated Shelf Identifier
.1.3.6.1.4.1.3607.6.10.30.0.6390
Software Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.640
Secondary Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6400
LMP Failure
.1.3.6.1.4.1.3607.6.10.30.0.6410
Optical Termination Incomplete
.1.3.6.1.4.1.3607.6.10.30.0.6420
Forward Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.6430
Payload Missing Indication
.1.3.6.1.4.1.3607.6.10.30.0.6440
Span loss not checked
.1.3.6.1.4.1.3607.6.10.30.0.6450
Ring Is Squelching High Order Traffic
.1.3.6.1.4.1.3607.6.10.30.0.6460
Ring Is Squelching Low Order Traffic
.1.3.6.1.4.1.3607.6.10.30.0.6470
Bad Packet Count Exceeds Threshold
.1.3.6.1.4.1.3607.6.10.30.0.6480
Link Layer Keep-Alive Failure
.1.3.6.1.4.1.3607.6.10.30.0.6490
Auto-Negotiation Remote Failure Indication
.1.3.6.1.4.1.3607.6.10.30.0.650
Third Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6500
Trail Signal Fail
.1.3.6.1.4.1.3607.6.10.30.0.6510
DS1 Loopback Command Sent To Far End
.1.3.6.1.4.1.3607.6.10.30.0.6520
Multiplex Section - Signal Degraded
.1.3.6.1.4.1.3607.6.10.30.0.6530
Multiplex Section - Excessive Errors
.1.3.6.1.4.1.3607.6.10.30.0.6540
High Order Path - Signal Degraded
.1.3.6.1.4.1.3607.6.10.30.0.6550
High Order Path - Excessive Errors
.1.3.6.1.4.1.3607.6.10.30.0.6560
Low Order Path - Signal Degraded
.1.3.6.1.4.1.3607.6.10.30.0.6570
Low Order Path - Excessive Errors
.1.3.6.1.4.1.3607.6.10.30.0.6580
Regenerator Section - DCC Termination Failure
.1.3.6.1.4.1.3607.6.10.30.0.6590
Network Memory Pool Low
.1.3.6.1.4.1.3607.6.10.30.0.660
Fourth Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6600
OSPF Routing Table Overflow
.1.3.6.1.4.1.3607.6.10.30.0.6610
Auto Laser Shutdown Disabled
.1.3.6.1.4.1.3607.6.10.30.0.6630
RPR Protection Is Active
.1.3.6.1.4.1.3607.6.10.30.0.6640
Max RPR Station Number Exceeded
.1.3.6.1.4.1.3607.6.10.30.0.6650
RPR Protection Configuration Mismatched
.1.3.6.1.4.1.3607.6.10.30.0.6660
Reserved Bandwidth Link Rate Exceeded On Ringlet0
.1.3.6.1.4.1.3607.6.10.30.0.6670
Reserved Bandwidth Link Rate Exceeded On Ringlet1
.1.3.6.1.4.1.3607.6.10.30.0.6680
RPR Interface In Pass Through Mode
.1.3.6.1.4.1.3607.6.10.30.0.6690
RPR Peer Node is Missing
.1.3.6.1.4.1.3607.6.10.30.0.670
Fifth Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6700
RPR RI Failure
.1.3.6.1.4.1.3607.6.10.30.0.6710
RPR Signal Failure
.1.3.6.1.4.1.3607.6.10.30.0.6720
RPR Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.6730
ADM Peer Cards Interlink Failure
.1.3.6.1.4.1.3607.6.10.30.0.6740
APC Wrong Gain Set Point
.1.3.6.1.4.1.3607.6.10.30.0.6750
RPR Span Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6760
EFM Remote Fault Inidication- Critical Event
.1.3.6.1.4.1.3607.6.10.30.0.6770
EFM Remote Fault Inidication- Dying Gasp
.1.3.6.1.4.1.3607.6.10.30.0.6780
EFM Remote Fault Inidication- Link Fault
.1.3.6.1.4.1.3607.6.10.30.0.6790
EFM Link Monitoring- Errored Symbol Period Event
.1.3.6.1.4.1.3607.6.10.30.0.680
Sixth Synchronization Reference Failure
.1.3.6.1.4.1.3607.6.10.30.0.6800
EFM Link Monitoring- Errored Frame Event
.1.3.6.1.4.1.3607.6.10.30.0.6810
EFM Link Monitoring- Errored Frame Period Event
.1.3.6.1.4.1.3607.6.10.30.0.6820
EFM Link Monitoring- Errored Frame Seconds Summary
.1.3.6.1.4.1.3607.6.10.30.0.6830
EFM Remote Loopback Request Failed
.1.3.6.1.4.1.3607.6.10.30.0.6840
Fast Automatic Protection Switching
.1.3.6.1.4.1.3607.6.10.30.0.6850
Fast Automatic Protection Switching Config Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6860
LCAS Sink Group Error
.1.3.6.1.4.1.3607.6.10.30.0.6870
LCAS VCG Member Rx Side In DNU State
.1.3.6.1.4.1.3607.6.10.30.0.6880
Fibre Channel Distance Extension Function Not Established
.1.3.6.1.4.1.3607.6.10.30.0.6890
Non Cisco PPM Inserted
.1.3.6.1.4.1.3607.6.10.30.0.690
failed to receive Synchronization Status Message
.1.3.6.1.4.1.3607.6.10.30.0.6900
Unqualified PPM Inserted
.1.3.6.1.4.1.3607.6.10.30.0.6910
FanTray Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.6920
Card/Ports Unable To Provide Protection
.1.3.6.1.4.1.3607.6.10.30.0.6930
LMP Signal Degrade
.1.3.6.1.4.1.3607.6.10.30.0.6940
LMP Signal Failure
.1.3.6.1.4.1.3607.6.10.30.0.6950
LMP Unallocated Data Link
.1.3.6.1.4.1.3607.6.10.30.0.6960
TCC Front Port Link Loss
.1.3.6.1.4.1.3607.6.10.30.0.6970
BERT Enabled
.1.3.6.1.4.1.3607.6.10.30.0.6975
BERT Synchronization Status Failed
.1.3.6.1.4.1.3607.6.10.30.0.6980
Work Queue Full
.1.3.6.1.4.1.3607.6.10.30.0.70
alarm indication signal
.1.3.6.1.4.1.3607.6.10.30.0.700
synchronization Status Messages are disabled on this
interface
.1.3.6.1.4.1.3607.6.10.30.0.7000
Equipment power failure at connector A
.1.3.6.1.4.1.3607.6.10.30.0.7005
Equipment power failure at connector B
.1.3.6.1.4.1.3607.6.10.30.0.7010
Equipment power failure at return connector A
.1.3.6.1.4.1.3607.6.10.30.0.7015
Equipment power failure at return connector B
.1.3.6.1.4.1.3607.6.10.30.0.7055
Bridge and Roll Has Occurred
.1.3.6.1.4.1.3607.6.10.30.0.7060
Bridge and Roll is Pending a Valid Signal
.1.3.6.1.4.1.3607.6.10.30.0.710
Stratum1 Primary Reference Source Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7160
Clock Bus Failure - Shelf Controller A
.1.3.6.1.4.1.3607.6.10.30.0.7165
Clock Bus Failure - Shelf Controller B
.1.3.6.1.4.1.3607.6.10.30.0.7185
OSPF Hello Fail
.1.3.6.1.4.1.3607.6.10.30.0.720
synchronized Traceability Unknown
.1.3.6.1.4.1.3607.6.10.30.0.7200
Open IO Slots
.1.3.6.1.4.1.3607.6.10.30.0.7210
Loss of Clock from Mate Shelf Controller
.1.3.6.1.4.1.3607.6.10.30.0.7225
Virtual Lan AIS
.1.3.6.1.4.1.3607.6.10.30.0.7230
DCU Loss Failure
.1.3.6.1.4.1.3607.6.10.30.0.7235
OCHNC Maintenance
.1.3.6.1.4.1.3607.6.10.30.0.7240
Raman Laser Shutdown
.1.3.6.1.4.1.3607.6.10.30.0.7245
Loss Of Raman Signal
.1.3.6.1.4.1.3607.6.10.30.0.7250
Multicast Mac Address Table Full
.1.3.6.1.4.1.3607.6.10.30.0.7255
Multicast Mac Address Aliasing
.1.3.6.1.4.1.3607.6.10.30.0.7260
Raman Power Protection On
.1.3.6.1.4.1.3607.6.10.30.0.7265
CPP Peer Not Responding
.1.3.6.1.4.1.3607.6.10.30.0.7275
VOA Control Loop Disable Due To Excessive Counter-Propagation Light
.1.3.6.1.4.1.3607.6.10.30.0.7280
Wizard Is Running
.1.3.6.1.4.1.3607.6.10.30.0.7285
Raman Span Not Tuned
.1.3.6.1.4.1.3607.6.10.30.0.7295
pprForwardDefectIndication
.1.3.6.1.4.1.3607.6.10.30.0.730
stratum 2 Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7300
pprBackwardDefectIndication
.1.3.6.1.4.1.3607.6.10.30.0.7305
pprCoordinatedMaintenance
.1.3.6.1.4.1.3607.6.10.30.0.7310
pprTriggerThresholdBERExceeded
.1.3.6.1.4.1.3607.6.10.30.0.7315
Local Fault
.1.3.6.1.4.1.3607.6.10.30.0.7320
Remote Fault
.1.3.6.1.4.1.3607.6.10.30.0.7325
EFM Port In Remote Loopback
.1.3.6.1.4.1.3607.6.10.30.0.7330
EFM Link To Peer Missing
.1.3.6.1.4.1.3607.6.10.30.0.7335
Equipment Degrade
.1.3.6.1.4.1.3607.6.10.30.0.7340
Excessive Back Propagation
.1.3.6.1.4.1.3607.6.10.30.0.7345
CFM Remote Maintenance End Point Is Down
.1.3.6.1.4.1.3607.6.10.30.0.7350
Cross Connected CFM Service
.1.3.6.1.4.1.3607.6.10.30.0.7355
CFM Loop
.1.3.6.1.4.1.3607.6.10.30.0.7360
CFM Configuration Error
.1.3.6.1.4.1.3607.6.10.30.0.7365
Out Of Channel Group Bundle
.1.3.6.1.4.1.3607.6.10.30.0.7370
REP Neighbor Adjacency Failure
.1.3.6.1.4.1.3607.6.10.30.0.7375
REP Link Flapping
.1.3.6.1.4.1.3607.6.10.30.0.7380
Fault In REP Segment
.1.3.6.1.4.1.3607.6.10.30.0.7385
Primary REP Edge Port Elected
.1.3.6.1.4.1.3607.6.10.30.0.7390
Secondary REP Edge Port Elected
.1.3.6.1.4.1.3607.6.10.30.0.7395
STCN REP Generated
.1.3.6.1.4.1.3607.6.10.30.0.740
transit Node clock Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7400
VLB REP Activated
.1.3.6.1.4.1.3607.6.10.30.0.7405
VLB REP Trigger Soaking Delay Active
.1.3.6.1.4.1.3607.6.10.30.0.7410
Ethernet Syncloss On WAN Port
.1.3.6.1.4.1.3607.6.10.30.0.7415
laser Shutdown Due To Wavelength Drift
.1.3.6.1.4.1.3607.6.10.30.0.7420
manual Laser Restart
.1.3.6.1.4.1.3607.6.10.30.0.7425
laserShutdownDueToNonCiscoPPMInserted
.1.3.6.1.4.1.3607.6.10.30.0.7430
Ethernet OSC Termination Failure
.1.3.6.1.4.1.3607.6.10.30.0.7445
software Signature Verification Failed
.1.3.6.1.4.1.3607.6.10.30.0.7450
Protect Volume Software Signature Verification
.1.3.6.1.4.1.3607.6.10.30.0.7455
Active Software Signature Verification Failed
.1.3.6.1.4.1.3607.6.10.30.0.7460
Peer Port Client Signal Fail Detected
.1.3.6.1.4.1.3607.6.10.30.0.7465
Channel Shutdown Due to Wavelength Drift
.1.3.6.1.4.1.3607.6.10.30.0.7475
USB Write Failure
.1.3.6.1.4.1.3607.6.10.30.0.7480
USB Sync in Progress
.1.3.6.1.4.1.3607.6.10.30.0.7485
Auto-Sensing Unable To Detect Valid Payload
.1.3.6.1.4.1.3607.6.10.30.0.7490
Payload Auto-Sensing In Progress
.1.3.6.1.4.1.3607.6.10.30.0.7495
GFP Client Signal Fail Detected Due To Sigloss
.1.3.6.1.4.1.3607.6.10.30.0.750
stratum 3E Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7500
GFP Client Signal Fail Detected Due To Syncloss
.1.3.6.1.4.1.3607.6.10.30.0.7510
PMD Degrade
.1.3.6.1.4.1.3607.6.10.30.0.7515
Standby Tcc NE Clock Is Internal Clock
.1.3.6.1.4.1.3607.6.10.30.0.7520
chromatic Dispersion Value
.1.3.6.1.4.1.3607.6.10.30.0.7525
Packet Transport Service Failed
.1.3.6.1.4.1.3607.6.10.30.0.7530
Satellite Panel Discovery Failure
.1.3.6.1.4.1.3607.6.10.30.0.7535
Satellite Panel Active Link Failure
.1.3.6.1.4.1.3607.6.10.30.0.7540
Satellite Panel Communication Failure
.1.3.6.1.4.1.3607.6.10.30.0.7545
Satellite Panel Improper Configuration
.1.3.6.1.4.1.3607.6.10.30.0.7550
Satellite Panel Fan Mismatch Of Equipment And Attributes
.1.3.6.1.4.1.3607.6.10.30.0.7555
Satellite Panel Fan Failure
.1.3.6.1.4.1.3607.6.10.30.0.7560
Satellite Panel Partial Fan Failure
.1.3.6.1.4.1.3607.6.10.30.0.7565
Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
.1.3.6.1.4.1.3607.6.10.30.0.7570
Satellite Panel FAN Unit Is Missing
.1.3.6.1.4.1.3607.6.10.30.0.7575
Satellite Panel Industrial High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.7580
Satellite Panel High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.7585
Satellite Panel Battery Failure A
.1.3.6.1.4.1.3607.6.10.30.0.7590
Planned Switch Over
.1.3.6.1.4.1.3607.6.10.30.0.7595
protection CardConfiguration Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.760
stratum 3 Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7600
Router Processor Switch Over
.1.3.6.1.4.1.3607.6.10.30.0.7605
Running Low On Resources
.1.3.6.1.4.1.3607.6.10.30.0.7610
No More Resources Are Available
.1.3.6.1.4.1.3607.6.10.30.0.7615
ESMC Failure
.1.3.6.1.4.1.3607.6.10.30.0.7620
License Will Expire Within 24 Hours
.1.3.6.1.4.1.3607.6.10.30.0.7625
license Will Expire Anytime After 1Day But Before 14Days
.1.3.6.1.4.1.3607.6.10.30.0.7630
license Is Expired
.1.3.6.1.4.1.3607.6.10.30.0.7635
license Count Violation
.1.3.6.1.4.1.3607.6.10.30.0.7640
Temporary License Is In Use
.1.3.6.1.4.1.3607.6.10.30.0.7645
Evaluation License Is In Use
.1.3.6.1.4.1.3607.6.10.30.0.7650
License Is Missing
.1.3.6.1.4.1.3607.6.10.30.0.7655
Pseudowire Down
.1.3.6.1.4.1.3607.6.10.30.0.7660
Working Pseudowire Control Plane Down
.1.3.6.1.4.1.3607.6.10.30.0.7665
Protect Pseudowire Control Plane Down
.1.3.6.1.4.1.3607.6.10.30.0.7670
Working Pseudowire Connectivity Check Down
.1.3.6.1.4.1.3607.6.10.30.0.7675
Protect Pseudowire Connectivity Check Down
.1.3.6.1.4.1.3607.6.10.30.0.7680
Pseudowire Traffic Switched To Pretection
.1.3.6.1.4.1.3607.6.10.30.0.7685
Working Pseudowire Local AcTx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7690
Protect Pseudowire Local AcTx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7695
Working Pseudowire Local AcRx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.770
SONET Minimum Clock Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7700
Protect Pseudowire Local AcRx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7705
Working Pseudowire Remote AcTx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7710
Protect Pseudowire Remote AcTx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7715
working Pseudowire Remote AcRx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7720
Protect Pseudowire Remote AcRx Port Fault
.1.3.6.1.4.1.3607.6.10.30.0.7725
SLA Threshold Cross Alert
.1.3.6.1.4.1.3607.6.10.30.0.7730
Protect Local Pseudowire Not Forwarding
.1.3.6.1.4.1.3607.6.10.30.0.7735
Working Remote Pseudowire Not Forwarding
.1.3.6.1.4.1.3607.6.10.30.0.7740
Protect Remote Pseudowire Not Forwarding
.1.3.6.1.4.1.3607.6.10.30.0.7745
Tp Tunnel Down
.1.3.6.1.4.1.3607.6.10.30.0.7750
Working Label Switched Path Down
.1.3.6.1.4.1.3607.6.10.30.0.7755
Protect Label Switched Path Down
.1.3.6.1.4.1.3607.6.10.30.0.7760
Working Label Switched Path Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.7765
Protect Label Switched Path Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.7770
Working Label Switched Path Remote Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.7775
Protect Label Switched Path Remote Defect Indication
.1.3.6.1.4.1.3607.6.10.30.0.7780
Bidirectional Forward Detection Down
.1.3.6.1.4.1.3607.6.10.30.0.7785
Tp Traffic Switched From Working To Protection
.1.3.6.1.4.1.3607.6.10.30.0.7790
working Tp Lockout
.1.3.6.1.4.1.3607.6.10.30.0.7795
protect Tp Lockout
.1.3.6.1.4.1.3607.6.10.30.0.780
stratum 4 Traceable
.1.3.6.1.4.1.3607.6.10.30.0.7800
Ethernet Flow Point Failed
.1.3.6.1.4.1.3607.6.10.30.0.7805
TE Tunnel Down
.1.3.6.1.4.1.3607.6.10.30.0.7810
MAC System Limit Reached
.1.3.6.1.4.1.3607.6.10.30.0.7815
MAC Bridge Domain Limit Reached
.1.3.6.1.4.1.3607.6.10.30.0.7820
Auto Sense Disabled
.1.3.6.1.4.1.3607.6.10.30.0.7825
SM Backward Incoming Alignment Error
.1.3.6.1.4.1.3607.6.10.30.0.7830
Resource Allocation Failed
.1.3.6.1.4.1.3607.6.10.30.0.7835
loss Of DFB Signal
.1.3.6.1.4.1.3607.6.10.30.0.7840
Working Label Switched Path Link Down Indication
.1.3.6.1.4.1.3607.6.10.30.0.7845
Protect Label Switched Path Link Down Indication
.1.3.6.1.4.1.3607.6.10.30.0.7850
Working Label Switched Path Lock Report
.1.3.6.1.4.1.3607.6.10.30.0.7855
Protect Label Switched Path Lock Report
.1.3.6.1.4.1.3607.6.10.30.0.7860
satellite Panel Battery FailureB
.1.3.6.1.4.1.3607.6.10.30.0.7865
High Bit Error Rate
.1.3.6.1.4.1.3607.6.10.30.0.7870
Back Panel Facility Loopback
.1.3.6.1.4.1.3607.6.10.30.0.7875
Back Panel Terminal Loopback
.1.3.6.1.4.1.3607.6.10.30.0.7880
Payload Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.7885
Invalid Muxponder Configuration
.1.3.6.1.4.1.3607.6.10.30.0.7890
Cooling Profile Mismatch
.1.3.6.1.4.1.3607.6.10.30.0.7895
Trunk ODU: Alarm Indication Signal
.1.3.6.1.4.1.3607.6.10.30.0.790
do not Use for Synchronization
.1.3.6.1.4.1.3607.6.10.30.0.7900
Companion Card Missing
.1.3.6.1.4.1.3607.6.10.30.0.7905
Control Plane Unverified Cleared Alarms Present
.1.3.6.1.4.1.3607.6.10.30.0.7910
Power Consumption Limit Has Crossed
.1.3.6.1.4.1.3607.6.10.30.0.7915
Master Key Exchange Failed
.1.3.6.1.4.1.3607.6.10.30.0.7930
Unit High Temperature
.1.3.6.1.4.1.3607.6.10.30.0.7935
Over Temperature Unit Protected
.1.3.6.1.4.1.3607.6.10.30.0.7945
Sequence Mismatch Count
.1.3.6.1.4.1.3607.6.10.30.0.7960
Key Program On Altera FPGA Failed
.1.3.6.1.4.1.3607.6.10.30.0.7970
Duplicate Node Controller Detected
.1.3.6.1.4.1.3607.6.10.30.0.7975
Restoration in Progress
.1.3.6.1.4.1.3607.6.10.30.0.7980
Raman Calibration Running
.1.3.6.1.4.1.3607.6.10.30.0.7985
Raman Calibration Pending
.1.3.6.1.4.1.3607.6.10.30.0.80
alarm indication signal LINE
.1.3.6.1.4.1.3607.6.10.30.0.800
reserved for Network Synchronization Use
.1.3.6.1.4.1.3607.6.10.30.0.810
outgoing failure condition
.1.3.6.1.4.1.3607.6.10.30.0.820
remote Defect Indication LINE
.1.3.6.1.4.1.3607.6.10.30.0.830
remote Defect Indication Path
.1.3.6.1.4.1.3607.6.10.30.0.840
free Running Synchronization mode
.1.3.6.1.4.1.3607.6.10.30.0.850
holdover synchronization mode
.1.3.6.1.4.1.3607.6.10.30.0.860
fast Start synchronization mode
.1.3.6.1.4.1.3607.6.10.30.0.870
Internal Fault
.1.3.6.1.4.1.3607.6.10.30.0.880
Internal Error
.1.3.6.1.4.1.3607.6.10.30.0.890
internal Message Error
.1.3.6.1.4.1.3607.6.10.30.0.90
alarm indication signal Path
.1.3.6.1.4.1.3607.6.10.30.0.900
mismatch of Equipment and Attributes
.1.3.6.1.4.1.3607.6.10.30.0.910
watchdog Timer Timeout
.1.3.6.1.4.1.3607.6.10.30.0.920
software Fault or failure
.1.3.6.1.4.1.3607.6.10.30.0.930
software Fault - Data integrity fault :
The newly added provisioning or hardware has
caused the database to grow beyond its limit.
That is, the newly added object(s) in the system
has(have) enough memory to exist onboard but
too large to be saved in the database.
.1.3.6.1.4.1.3607.6.10.30.0.940
program failure
.1.3.6.1.4.1.3607.6.10.30.0.950
control Equipment failure
.1.3.6.1.4.1.3607.6.10.30.0.960
Primary Non-Volatile Backup Memory Failure
.1.3.6.1.4.1.3607.6.10.30.0.970
Secondary Non-Volatile Backup Memory Failure
.1.3.6.1.4.1.3607.6.10.30.0.980
Control Bus Failure
.1.3.6.1.4.1.3607.6.10.30.0.990
Control Bus 1 Failure