CERENT-454-MIB

        This module provides the definitions for
objects for managing Cisco OTBU ONS 15454.
    

Imported Objects

cerentModules, cerentProductsCERENT-GLOBAL-REGISTRY
CerentPortNumber, CerentPeriod, CerentLocation, CerentMonitorType, CerentAlarmServiceAffecting, CerentAlarmStatus, CerentAlarmSeverity, CerentNotificationClassCERENT-TC
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCESNMPv2-CONF
MODULE-IDENTITY, Counter32, Unsigned32, Integer32, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPESNMPv2-SMI
TimeStamp, TruthValue, DisplayString, TEXTUAL-CONVENTIONSNMPv2-TC

Type Definitions (2)

Name Base Type Values/Constraints
Cerent454AlarmTypealarmUnknown(1), alarmCutoffIsInManualMode(10), failureDetectedExternalToTheNE(20), externalError(30), excessiveSwitching(40), sdccTerminationFailure(50), incomingFailureCondition(60), alarmIndicationSignal(70), alarmIndicationSignalLine(80), alarmIndicationSignalPath(90), alarmIndicationSignalVT(100), apsChannelFailure(110), channelByteFailureAPS(120), channelProtectionSwitchingChannelMatchFailureAPS(130), channelAutomaticProtectionSwitchModeMismatchAPS(140), farEndProtectionLineFailure(150), inconsistentAPSCode(160), improperAPSCode(170), nodeIdMismatch(180), channelDefaultKAPS(190), connectionLoss(200), bipolarViolation(210), carrierLossOnTheLAN(220), concatenationErrorSTS(230), excessCollisionsOnTheLAN(240), facilityFailure(250), farEndAIS(260), farEndMultipleDS1LOSDetectedOnDS3(270), farEndDS1EqptFailNonServiceAffecting(280), farEndDS1EqptFailServiceAffecting(290), farEndSingleDS1LOS(300), farEndDS3EqptFailNonServiceAffecting(310), farEndDS3EqptFailServiceAffecting(320), farEndCommonEquipmentFailureNonServiceAffecting(330), farEndIDLE(340), farEndLOS(350), farEndLOF(360), farEndBlockError(370), ds3IdleCondition(380), lossOfFrame(390), lossOfPointer(400), lossOfPointerPath(410), lossOfPointerVT(420), lossOfSignal(430), outOfFrame(440), pathSelectorFailure(450), remoteAlarmIndication(460), remoteFailureIndication(470), remoteFailureIndicationLine(480), remoteFailureIndicationPath(490), remoteFailureIndicationVT(500), signalDegrade(510), severelyErroredFrame(520), signalFailure(530), signalLabelMismatchFailure(540), payloadDefectIndication(550), payloadDefectIndicationPath(560), payloadLabelMismatchPath(570), signalLabelMismatchFailurePayloadLabelMismatchVT(580), unequippedPath(590), signalLabelMismatchFailureUnequippedVT(600), lossOfSynchronization(610), outOfSynchronization(620), primarySynchronizationReferenceFailure(630), secondarySynchronizationReferenceFailure(640), thirdSynchronizationReferenceFailure(650), fourthSynchronizationReferenceFailure(660), fifthSynchronizationReferenceFailure(670), sixthSynchronizationReferenceFailure(680), failedToReceiveSynchronizationStatusMessage(690), synchronizationStatusMessagesAreDisabledOnThisInterface(700), stratum1PrimaryReferenceSourceTraceable(710), synchronizedTraceabilityUnknown(720), stratum2Traceable(730), transitNodeClockTraceable(740), stratum3ETraceable(750), stratum3Traceable(760), sonetMinimumClockTraceable(770), stratum4Traceable(780), doNotUseForSynchronization(790), reservedForNetworkSynchronizationUse(800), outgoingFailureCondition(810), remoteDefectIndicationLine(820), remoteDefectIndicationPath(830), freeRunningSynchronizationMode(840), holdoverSynchronizationMode(850), fastStartSynchronizationMode(860), internalFault(870), internalError(880), internalMessageError(890), mismatchOfEquipmentAndAttributes(900), watchdogTimerTimeout(910), softwareFaultOrFailure(920), softwareFaultDataIntegrityFault(930), programFailure(940), controlEquipmentFailure(950), primaryNonVolatileBackupMemoryFailure(960), secondaryNonVolatileBackupMemoryFailure(970), controlBusFailure(980), controlBus1Failure(990), controlBus2Failure(1000), tccAToShelfSlot1DROP1CommunicationFailure(1010), tccAToShelfSlot2DROP2CommunicationFailure(1020), tccAToShelfSlot3DROP3CommunicationFailure(1030), tccAToShelfSlot4DROP4CommunicationFailure(1040), tccAToShelfSlot5TRUNK1CommunicationFailure(1050), tccAToShelfSlot6TRUNK2CommunicationFailure(1060), tccAToShelfSlot7TCCACommunicationFailure(1070), tccAToShelfSlot8XCONACommunicationFailure(1080), tccAToShelfSlot9AICCommunicationFailure(1090), tccAToShelfSlot10XCONBCommunicationFailure(1100), tccAToShelfSlot11TCCBCommunicationFailure(1110), tccAToShelfSlot12TRUNK3CommunicationFailure(1120), tccAToShelfSlot13TRUNK4CommunicationFailure(1130), tccAToShelfSlot14DROP5CommunicationFailure(1140), tccAToShelfSlot15DROP6CommunicationFailure(1150), tccAToShelfSlot16DROP7CommunicationFailure(1160), tccAToShelfSlot17DROP8CommunicationFailure(1170), tccAToDCCAProcessorCommunicationFailure(1180), tccBToShelfSlot1DROP1CommunicationFailure(1190), tccBToShelfSlot2DROP2CommunicationFailure(1200), tccBToShelfSlot3DROP3CommunicationFailure(1210), tccBToShelfSlot4DROP4CommunicationFailure(1220), tccBToShelfSlot5TRUNK1CommunicationFailure(1230), tccBToShelfSlot6TRUNK2CommunicationFailure(1240), tccBToShelfSlot7TCCACommunicationFailure(1250), tccBToShelfSlot8XCONACommunicationFailure(1260), tccBToShelfSlot9AICCommunicationFailure(1270), tccBToShelfSlot10XCONBCommunicationFailure(1280), tccBToShelfSlot11TCCBCommunicationFailure(1290), tccBToShelfSlot12TRUNK3CommunicationFailure(1300), tccBToShelfSlot13TRUNK4CommunicationFailure(1310), tccBToShelfSlot14DROP5CommunicationFailure(1320), tccBToShelfSlot15DROP6CommunicationFailure(1330), tccBToShelfSlot16DROP7CommunicationFailure(1340), tccBToShelfSlot17DROP8CommunicationFailure(1350), tccBToDCCBProcessorCommunicationFailure(1360), controlEquipmentControlCommunicationsEquipmentFailure(1370), controlProcessorFailure(1380), workingMemoryFailure(1390), interconnectionEquipmentFailure(1400), payloadBusFailureToIOSlot1XCONSlot8(1410), payloadBusFailureToIOSlot2XCONSlot8(1420), payloadBusFailureToIOSlot3XCONSlot8(1430), payloadBusFailureToIOSlot4XCONSlot8(1440), payloadBusFailureToIOSlot5XCONSlot8(1450), payloadBusFailureToIOSlot6XCONSlot8(1460), payloadBusFailureToIOSlot12XCONSlot8(1470), payloadBusFailureToIOSlot13XCONSlot8(1480), payloadBusFailureToIOSlot14XCONSlot8(1490), payloadBusFailureToIOSlot15XCONSlot8(1500), payloadBusFailureToIOSlot16XCONSlot8(1510), payloadBusFailureToIOSlot17XCONSlot8(1520), payloadBusFailureToIOSlot1XCONSlot10(1530), payloadBusFailureToIOSlot2XCONSlot10(1540), payloadBusFailureToIOSlot3XCONSlot10(1550), payloadBusFailureToIOSlot4XCONSlot10(1560), payloadBusFailureToIOSlot5XCONSlot10(1570), payloadBusFailureToIOSlot6XCONSlot10(1580), payloadBusFailureToIOSlot12XCONSlot10(1590), payloadBusFailureToIOSlot13XCONSlot10(1600), payloadBusFailureToIOSlot14XCONSlot10(1610), payloadBusFailureToIOSlot15XCONSlot10(1620), payloadBusFailureToIOSlot16XCONSlot10(1630), payloadBusFailureToIOSlot17XCONSlot10(1640), timeSlotInterchangeEquipmentFailure(1650), equipmentFailure(1660), highTemperature(1670), invalidMACAddress(1680), boardFailure(1690), diagnosticFailure(1700), mediumAccessControlFailure(1710), facilityTerminationEquipmentFailure(1720), automaticLaserShutoffDueToHighTemperature(1730), failureToReleaseFromProtection(1740), receiverFailure(1750), transmitFailure(1760), facilityTerminationEquipmentReceiverMissing(1770), facilityTerminationEquipmentTransmitterMissing(1780), failureToSwitchToProtection(1790), failureToSwitchToProtectionRing(1800), failureToSwitchToProtectionSpan(1810), failureToSwitchToProtectionPath(1820), fanFailure(1830), equipmentUnitPlugIn(1840), nePowerFailureAtConnector(1850), fuseAlarm(1860), synchronizationUnitFailure(1870), synchronizationSwitchingEquipmentFailure(1880), equipmentUnitUnplugged(1890), loopback(1900), ds1LoopbackDueToFEACCommand(1910), loopbackCommandSentToFarEndDS1(1920), ds3LoopbackDueToFEACCommand(1930), ds3LoopbackCommandSentToFarEnd(1940), ds2LoopbackDueToFarEndCommand(1950), ds2LoopbackCommandSentToFarEnd(1960), facilityLoopback(1970), networkLoopback(1980), terminalLoopback(1990), manuallyCausedAbnormalCondition(2000), ethernetBridgeIsNewRootOfSpanningTree(2010), ethernetBridgeTopologyChange(2020), normalCondition(2030), embeddedOperationsChannelFailureLinkDown(2040), peerStateMismatch(2050), proceduralError(2060), improperRemoval(2070), duplicateNodeID(2080), blsrOutOfSync(2090), blsrMultiNodeTableUpdateCompleted(2100), protectionUnitNotAvailable(2110), performanceMonitorThresholdCrossingAlert(2120), protectionSwitch(2130), recoveryOrServiceProtectionActionHasBeenInitiated(2140), automaticSystemReset(2150), automaticUPSRSwitchCausedByAIS(2160), automaticUPSRSwitchCausedByLOP(2170), automaticUPSRSwitchCausedByUNEQ(2180), automaticUPSRSwitchCausedByPDI(2190), automaticUPSRSwitchCausedBySFBER(2200), automaticUPSRSwitchCausedBySDBER(2210), coldRestart(2220), forcedSwitchBackToWorking(2230), forcedSwitchBackToWorkingRing(2240), forcedSwitchBackToWorkingSpan(2250), forcedSwitchToProtection(2260), forcedSwitchToProtectionRing(2270), forcedSwitchToProtectionSpan(2280), workingFacilityOrEquipmentForcedToSwitchToProtectionPath(2290), initializationInitiated(2300), lockoutOfProtection(2310), lockoutOfProtectionRing(2320), lockoutOfProtectionSpan(2330), lockoutOfProtectionPath(2340), lockoutOfWorking(2350), lockoutOfWorkingRing(2360), lockoutOfWorkingSpan(2370), manualSystemReset(2380), manualSwitchToInternalClock(2390), manualSwitchToPrimaryReference(2400), manualSwitchToSecondReference(2410), manualSwitchToThirdReference(2420), manualSwitchToFourthReference(2430), manualSwitchToFifthReference(2440), manualSwitchToSixthReference(2450), manualSwitchBackToWorking(2460), manualSwitchBackToWorkingRing(2470), manualSwitchBackToWorkingSpan(2480), manualSwitchToProtection(2490), manualSwitchToProtectionRing(2500), manualSwitchToProtectionSpan(2510), manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath(2520), powerfailRestart(2530), ringIsSquelchingTraffic(2540), softwareDownloadInProgress(2550), switchToInternalClock(2560), switchToPrimaryReference(2570), switchToSecondReference(2580), switchToThirdReference(2590), switchToFourthReference(2600), switchToFifthReference(2610), switchToSixthReference(2620), systemReboot(2630), switchedBackToWorking(2640), switchedToProtection(2650), warmRestart(2660), ringIsInWaitToRestoreState(2670), manualSwitchRequest(2680), forcedSwitchRequest(2690), lockoutSwitchRequest(2700), rmonHistoriesAndAlarmsResetReboot(2710), rmonThresholdCrossingAlarm(2720), alarmsSuppressedByUserCommand(2730), alarmsSuppressedForMaintenance(2740), switchingMatrixModuleFailure(2750), lanConnectionPolarityReversed(2760), autonomousPMReportMessageInhibited(2780), ioSlotToXCONCommunicationFailure(2790), stsPathTraceIdentifierMismatch(2800), nePowerFailureAtConnectorA(2810), nePowerFailureAtConnectorB(2820), freeMemoryOnCardVeryLow(2830), freeMemoryOnCardNearZero(2840), exerciseRequestOnRing(2850), exerciseRequestOnSpan(2860), squelchingPath(2870), extraTrafficPreempted(2880), farEndLockoutOfWorkingRing(2890), farEndLockoutOfWorkingSpan(2900), farEndLockoutOfProtectionRing(2910), farEndLockoutOfProtectionAllSpans(2920), farEndWorkingFacilityForcedToSwitchToProtectionRing(2930), farEndWorkingFacilityForcedToSwitchToProtectionSpan(2940), farEndManualSwitchOfWorkingFacilityToProtectionRing(2950), farEndManualSwitchOfWorkingFacilityToProtectionSpan(2960), farEndExercisingRing(2970), farEndExercisingSpan(2980), farEndBERThresholdPassedForSignalFailureRing(2990), farEndBERThresholdPassedForSignalFailureSpan(3000), farEndBERThresholdPassedForSignalDegradeRing(3010), farEndBERThresholdPassedForSignalDegradeSpan(3020), apsChannelFarEndProtectionLineSignalDegrade(3030), ringSwitchIsActiveOnTheEastSide(3040), ringSwitchIsActiveOnTheWestSide(3050), spanSwitchIsActiveOnTheEastSide(3060), spanSwitchIsActiveOnTheWestSide(3070), uniDirectionalFullPassThroughIsActive(3080), biDirectionalFullPassThroughIsActive(3090), kBytesPassThroughIsActive(3100), ringIsSegmented(3110), ringTopologyIsUnderConstruction(3120), lockoutOfProtectionAllSpans(3130), farEndOfFiberIsProvisionedWithDifferentRingID(3140), bothEndsOfFiberProvisionedAsEastOrBothAsWest(3150), securityInvalidLoginUsernameSeeAuditTrail(3160), autonomousMessagesInhibited(3170), trafficStormOnLANLANTemporarilyDisabled(3180), reptdbchgMessagesInhibited(3190), securityUserIDHasExpired(3200), partialFanFailure(3210), forcedSwitchRequestOnRing(3220), forcedSwitchRequestOnSpan(3230), lockoutSwitchRequestOnRing(3240), lockoutSwitchRequestOnSpan(3250), manualSwitchRequestOnRing(3260), manualSwitchRequestOnSpan(3270), communicationFailurePeerToPeerSlotControlBusA(3280), communicationFailurePeerToPeerSlotControlBusB(3290), controllerAToShelfSlotCommunicationFailure(3300), controllerBToShelfSlotCommunicationFailure(3310), interconnectionEquipmentFailureWorkingPayloadBus(3320), interconnectionEquipmentFailureProtectPayloadBus(3330), inhibitSwitchToProtectRequestOnEquipment(3340), inhibitSwitchToWorkingRequestOnEquipment(3350), berThresholdExceededForSignalDegradeLine(3360), berThresholdExceededForSignalDegradePath(3370), berThresholdExceededForSignalFailureLine(3380), berThresholdExceededForSignalFailurePath(3390), exercisingRingSuccessfully(3400), exercisingSpanSuccessfully(3410), spanIsInWaitToRestoreState(3420), exerciseRequestOnRingFailed(3430), exerciseRequestOnSpanFailed(3440), farEndLockoutOfProtectionSpan(3450), manufacturingDataMemoryEEPROMFailure(3460), replaceableEquipmentOrUnitIsMissing(3470), softwareDownloadFailed(3480), extraTrafficPCADropped(3490), etherTxOversubscribed(3500), etherRxOverSubscribed(3510), etherTxExcessFlowCtrl(3520), etherRxExcessFlowCtrl(3530), transportLayerFailure(3540), etherTxUnderrun(3550), synchronizationReferenceFrequencyOutOfBounds(3560), ntpOrSntpHostFailure(3570), peerCardNotResponding(3580), alarmsAndEventsSuppressedForThisObject(3590), ds3FrameFormatMismatch(3600), waitToRestore(3610), extremeHighVoltBatteryA(3620), extremeLowVoltBatteryA(3630), extremeHighVoltBatteryB(3640), extremeLowVoltBatteryB(3650), iosConfigCopyFailed(3660), iosConfigCopyInProgress(3670), iosConfigCopySuccess(3680), signalingUnableToSetupCircuit(3710), errorInStartupConfig(3712), noStartupConfig(3714), needToSaveRunningConfig(3716), invalidAlarm(3718), rsvpHelloFSMToNeighborDown(3720), securityInvalidLoginUsername(3722), databaseBackupFailed(3724), databaseRestoreFailed(3726), lmpHelloFSMToControlChannelDown(3730), lmpNeighborDiscoveryHasFailed(3740), unauthorizedIncomingSignalingRequest(3750), auditLog80PercentFull(3760), moduleCommunicationFailure(3762), auditLog100PercentFullOldestRecordsWillBeLost(3764), standbyDatabaseOutOfSync(3766), redundantPowerCapabilityLost(3768), forcedSwitchToPrimaryReference(3770), forcedSwitchToSecondReference(3780), forcedSwitchToThirdReference(3790), forcedSwitchToInternalClock(3800), industrialHighTemperature(3805), timSectionTraceIdentifierMismatchFailure(4000), aisMultiplexSectionAlarmIndicationSignal(4010), rdiMultiplexSectionRemoteDefectOrAlarmIndication(4020), timHighOrderTraceIdentifierMismatchFailure(4030), aisAdministrationUnitAlarmIndicationSignal(4040), lopAdministrationUnitLossOfPointer(4050), slmfUnequippedHighOrderPathUnequipped(4060), slmfPLMHighOrderPathLabelMismatch(4070), rdiHighOrderRemoteDefectOrAlarmIndication(4080), lopTributaryUnitLossOfPointer(4090), aisTributaryUnitAlarmIndicationSignal(4100), slmfUnequippedLowOrderPathUnequipped(4110), slmfPLMLowOrderPathLabelMismatch(4120), timLowOrderTraceIdentifierMismatchFailure(4130), rfiLowOrderRemoteFailureOrAlarmIndication(4140), g811PrimaryReferenceClockTraceable(4150), g812TransitNodeClockTraceable(4160), g812LocalNodeClockTraceable(4170), g813SynchronousEquipmentTimingSourceTraceable(4180), e1LoopbackDueToFEACCommand(4190), e1LoopbackCommandSentToFarEnd(4200), e3LoopbackDueToFEACCommand(4210), farEndMultipleE1LOSDetectedOnE3(4220), farEndE1EqptFailNonServiceAffecting(4230), farEndE1EqptFailServiceAffecting(4240), farEndSingleE1LOS(4250), farEndE3EqptFailServiceAffecting(4260), e3LoopbackCommandSentToFarEnd(4270), farEndE3EqptFailNonServiceAffecting(4280), lowVoltBatteryA(4290), highVoltBatteryA(4300), lowVoltBatteryB(4310), highVoltBatteryB(4320), msspRingOutOfSync(4330), msspMultiNodeTableUpdateCompleted(4340), automaticSNCPSwitchCausedByAIS(4350), automaticSNCPSwitchCausedByLOP(4360), automaticSNCPSwitchCausedByUNEQ(4370), automaticSNCPSwitchCausedByPDI(4380), automaticSNCPSwitchCausedBySFBER(4390), automaticSNCPSwitchCausedBySDBER(4400), stmConcatenationError(4410), e3IdleCondition(4420), channelMSSPInconsistentAPSCode(4430), channelMSSPImproperAPSCodeAPS(4440), channelMSSPNodeIdMismatchAPS(4450), channelMSSPDefaultKAPS(4460), channelMSSPConnectionLossAPS(4470), minimumClockTraceableSDH(4480), lineIsInWaitToRestoreStateSDH(4490), berThresholdExceededForSignalDegradeHighOrder(4500), berThresholdExceededForSignalFailureHighOrder(4510), berThresholdExceededForSignalDegradeLowOrder(4520), berThresholdExceededForSignalFailureLowOrder(4530), failureToSwitchToProtectionHighOrderPath(4540), failureToSwitchToProtectionLowOrderPath(4550), lofAdministrationUnitLossOfMultiFrame(4560), sdhSpanIsInWaitToRestoreState(4570), a8b10bOutOfSync(4755), odukPMAlarmIndicationSignal(4760), otukAlarmIndicationSignal(4765), otukSMBackwardDefectIndication(4770), fecUncorrectedWord(4780), gccTerminationFailure(4785), otukIncomingAlignmentError(4790), odukLockedDefectPM(4795), lossOfMultiFrame(4800), odukOpenConnectionIndication(4805), payloadTypeIdentifierMismatch(4810), odukTrailTraceIdentifierMismatch(4815), otukTrailTraceIdentifierMismatch(4820), equipmentHighLaserBias(4825), equipmentHighLaserTemp(4830), equipmentHighLaserPeltier(4835), facilityHighRxPower(4840), equipmentHighTxPower(4845), equipmentHighTransceiverVoltage(4850), equipmentLowLaserBias(4855), equipmentLowLaserTemp(4860), equipmentLowLaserPeltier(4865), facilityLowRxPower(4870), equipmentLowTxPower(4875), equipmentLowTransceiverVoltage(4880), equipmentRxLocked(4885), equipmentSquelched(4890), equipmentTxLocked(4895), otukSignalFailure(4900), odukSignalFailure(4905), otukSignalDegrade(4910), odukSignalDegrade(4915), pluggablePortMissing(4920), pluggablePortRateMismatch(4925), pluggablePortSecurityCodeMismatch(4930), tciNotSelected(4935), tci1ClockFailure(4940), odukPMBackwardDefectIndication(4945), odukTCM1BackwardDefectIndication(4950), odukTCM2BackwardDefectIndication(4955), equipmentHighRxTemperature(4960), equipmentLowRxTemperature(4965), tci2ClockFailure(4970), equipmentWavelengthMismatch(4975), dspCommunicationFailure(4980), dspFailure(4985), laserApproachingEndOfLife(5000), crossconnectLoopback(5010), adminLogoutOfUser(5020), userLockedOut(5030), adminLockoutOfUser(5040), adminLockoutClear(5050), invalidLoginUsername(5060), securityInvalidLoginPassword(5070), securityInvalidLoginLockedOut(5080), securityInvalidLoginAlreadyLoggedOn(5090), loginOfUser(5100), automaticLogoutOfIdleUser(5110), logoutOfUser(5120), enhancedRemoteFailureIndicationPathServer(5200), enhancedRemoteFailureIndicationPathConnectivity(5210), enhancedRemoteFailureIndicationPathPayload(5220), firewallHasBeenDisabled(5230), securityIntrusionDetPwd(5240), securityIntrusionDetUser(5250), connectionEquipmentMismatch(5260), disableInactiveUser(5270), disableInactiveClear(5280), batteryFailure(5290), extremeHighVolt(5300), extremeLowVolt(5310), highVolt(5320), lowVolt(5330), suspendUser(5340), suspendUserClear(5350), lineDccTerminationFailure(5360), multiplexSectionDccTerminationFailure(5370), gigaBitEthernetOutOfSync(5380), sequenceMismatch(5390), lossOfAlignment(5400), outOfUseByAdministrativeCommand(5410), outOfUseTransportFailure(5420), vcatGroupDown(5430), vcatGroupDegraded(5440), vcatGroupIncomplete(5450), alarmIndicationSignalInTX(5460), remoteAlarmIndicationInTX(5470), kByteAPSChannelFailure(5480), apsInvalidMode(5490), ipAddressAlreadyInUseWithinTheSameDccArea(5500), nodeNameInUseWithinTheSameDccArea(5510), rearPanelEthernetLinkRemoved(5520), manualSwitchToProtectResultedInNoTrafficSwitch(5530), manualSwitchBackToWorkingResultedInNoTrafficSwitch(5540), forcedSwitchToProtectResultedInNoTrafficSwitch(5550), forcedSwitchBackToWorkingResultedInNoTrafficSwitch(5560), duplicateSerialNumberDetectedOnAPluggableEntity(5570), lossOfSignalForOpticalChannel(5600), encapsulationMismatchPath(5610), encapsulationMismatchVT(5620), encapsulationMismatchHighOrderPath(5630), encapsulationMismatchLowOrderPath(5640), gfpUserPayloadMismatch(5650), gfpFibreChannelDistanceExtensionMismatch(5660), gfpFibreChannelDistanceExtensionBufferStarvation(5670), gfpFibreChannelDistanceExtensionCreditStarvation(5680), automaticWdmAnsFinished(5690), gfpClientSignalFailDetected(5700), gfpLossOfFrameDelineation(5710), gfpExtensionHeaderMismatch(5730), incomingOverheadSignalAbsent(5740), opticalSafetyRemoteInterlockOn(5750), automaticPowerControlCorrectionSkipped(5770), apcCannotSetValueDueToRangeLimits(5780), lcasVcgMemberTxSideInAddState(5790), farEndManualSwitchBackToWorkingSpan(5800), farEndForcedSwitchBackToWorkingSpan(5810), universalTransponderModuleHardwareFailure(5820), universalTransponderModuleCommunicationFailure(5830), pluginModuleRangeSettingsMismatch(5840), lcasVcgMemberTxSideInDnuState(5850), lcasControlWordCrcCheckFailure(5860), lcasVcgMemberRxSideInFailState(5870), signalLossOnDataInterface(5880), synchronizationLossOnDataInterface(5890), portFAIL(5900), unreachablePortTargetPower(5910), portAddPowerDegradeLow(5920), portAddPowerDegradeHigh(5930), portAddPowerFailLow(5940), portAddPowerFailHigh(5950), automaticPowerControlTerminatedOnManualRequest(6000), oduk1AlarmIndicationSignal(6010), oduk2AlarmIndicationSignal(6020), oduk3AlarmIndicationSignal(6030), oduk4AlarmIndicationSignal(6040), temperatureReadingMismatchBetweenSCCards(6050), voltageReadingMismatchBetweenSCCards(6060), alarmsSuppressedonOutOfGroupVcatMember(6070), blsrSoftwareVersionMismatch(6080), optimized1Plus1ApsPrimaryFacility(6090), optimized1Plus1ApsPrimarySectionMismatch(6100), optimized1Plus1ApsInvalidPrimarySection(6110), compositeClockHighLineVoltage(6120), berThresholdExceededForSignalDegradeVt(6130), berThresholdExceededForSignalFailureVt(6140), spanLengthOutOfRange(6150), idleSignalCondition(6170), idleSignalConditionInTx(6180), vtPathTraceIdentifierMismatch(6190), lossOfFrameInTX(6200), provisioningMismatch(6210), sectionTraceIdentifierMismatch(6220), regeneratorSectionTraceIdentifierMismatch(6230), switchingMatrixModuleFailureWorking(6240), switchingMatrixModuleFailureProtect(6250), slotCommunicationDisabled(6260), sessionTimeLimitExpired(6270), userPasswordChangeRequired(6280), isisAdjacencyFailure(6290), msspSoftwareVersionMismatch(6300), remoteAuthenticationFailSeeAuditLog(6310), ringIsSquelchingStsTraffic(6330), ringIsSquelchingVtTraffic(6340), archiveOfAuditLogFailed(6350), rprWrapped(6360), shelfCommunicationFailure(6370), duplicatedShelfIdentifier(6380), softwareMismatch(6390), lmpFailure(6400), opticalTerminationIncomplete(6410), forwardDefectIndication(6420), payloadMissingIndication(6430), spanMeasurementCannotBePerformed(6440), ringIsSquelchingHighOrderTraffic(6450), ringIsSquelchingLowOrderTraffic(6460), badPacketCountExceedsThreshold(6470), linkLayerKeepAliveFailure(6480), autonegotiationRemoteFailureIndication(6490), trailSignalFail(6500), ds1LoopbackCommandSentToFarEnd(6510), multiplexSectionSignalDegraded(6520), multiplexSectionExcessiveErrors(6530), highOrderPathSignalDegraded(6540), highOrderPathExcessiveErrors(6550), lowOrderPathSignalDegraded(6560), lowOrderPathExcessiveErrors(6570), regeneratorSectionDccTerminationFailure(6580), networkMemoryPoolLow(6590), ospfRoutingTableOverflow(6600), autoLaserShutdownDisabled(6610), rprProtectionIsActive(6630), maxRPRStationNumberExceeded(6640), rprProtectionConfigurationMismatched(6650), reservedBandwidthLinkRateExceededOnRinglet0(6660), reservedBandwidthLinkRateExceededOnRinglet1(6670), rprInterfaceInPassThroughMode(6680), rprPeerNodeIsMissing(6690), rprRiFailure(6700), rprSignalFailure(6710), rprSignalDegrade(6720), interlinkFailure(6730), apcWrongGain(6740), rprSpanMismatch(6750), efmRemoteFaultIndicationCriticalEvent(6760), efmRemoteFaultIndicationDyingGasp(6770), efmRemoteFaultIndicationLinkFault(6780), efmLinkMonitoringErroredSymbolPeriodEvent(6790), efmLinkMonitoringErroredFrameEvent(6800), efmLinkMonitoringErroredFramePeriodEvent(6810), efmLinkMonitoringErroredFrameSecondsSummary(6820), efmRemoteLoopbackRequestFailed(6830), fastAutomaticProtectionSwitching(6840), fastAutomaticProtectionSwitchingConfigMismatch(6850), lcasSinkGroupError(6860), lcasVcgMemberRxSideInDnuState(6870), fcDistanceExtFuncNotEstablished(6880), nonCiscoPPMInserted(6890), unqualifiedPPMInserted(6900), ftaMismatch(6910), cardPortsUnableToProvideProtection(6920), lmpSignalDegrade(6930), lmpSignalFailure(6940), lmpUnallocatedDataLink(6950), frontPortLinkLoss(6960), bertEnbl(6970), bertSyncFail(6975), workQueueFull(6980), equipmentPowerFailureAtConnectorA(7000), equipmentPowerFailureAtConnectorB(7005), equipmentPowerFailureAtReturnConnectorA(7010), equipmentPowerFailureAtReturnConnectorB(7015), bridgeAndRollHasOccurred(7055), bridgeAndRollIsPendingAValidSignal(7060), clockBusFailureTscA(7160), clockBusFailureTscB(7165), ospfHelloFail(7185), openIOSlots(7200), lossOfClockFromMateShelfController(7210), virtualLanAlarmIndiacationSignal(7225), dcuLossFailure(7230), ochncMaintenance(7235), ramanLaserShutdown(7240), losOfRamanSignal(7245), mcastMacTableFull(7250), multicastMacAddressAliasing(7255), ramanPwrProtOn(7260), cppPeerNotResponding(7265), voaControlLoopDisableDueToExcessiveCounterPropagationLight(7275), wizardIsRunning(7280), ramanGainNotReached(7285), pprForwardDefectIndication(7295), pprBackwardDefectIndication(7300), pprCoordinatedMaintenance(7305), pprTriggerThresholdBerExceeded(7310), localFault(7315), remoteFault(7320), efmRemoteLoopbackConfigured(7325), efmPeerMissing(7330), eqptDegrade(7335), excessiveBackPropagation(7340), remoteMaintenanceEndPointIsDown(7345), crossConnectedCFMService(7350), cfmLoop(7355), cfmConfigurationError(7360), outOfChannelGroupBundle(7365), repNeighborAdjacencyFailure(7370), repLinkFlapping(7375), faultInREPSegment(7380), primaryREPEdgePortElected(7385), secondaryREPEdgePortElected(7390), stcnREPGenerated(7395), vlbREPActivated(7400), vlbREPTriggerSoakingDelayActive(7405), wanSyncloss(7410), laserShutdownDueToWavelengthDrift(7415), manualLaserRestart(7420), laserShutdownDueToNonCiscoPPMInserted(7425), ethernetOSCTerminationFailure(7430), softwareSignatureVerificationFailed(7445), protectVolumeSoftwareSignatureVerificationFailed(7450), activeVolumeSoftwareSignatureVerificationFailed(7455), peerPortClientSignalFailDetected(7460), channelShutdownDueToWavelengthDrift(7465), usbWriteFailure(7475), usbSyncInProgress(7480), autoSensingUnableToDetectValidPayload(7485), payloadAutoSensingInProgress(7490), gfpClientSignalFailDetectedDueToSigloss(7495), gfpClientSignalFailDetectedDueToSyncloss(7500), pmdDegrade(7510), standbyTccNEClockIsInternalClock(7515), chromaticDispersionValue(7520), packetTransportServiceFailed(7525), satellitePanelDiscoveryFailure(7530), satellitePanelActiveLinkFailure(7535), satellitePanelCommunicationFailure(7540), satellitePanelImproperConfiguration(7545), satellitePanelFanMismatchOfEquipmentAndAttributes(7550), satellitePanelFanFailure(7555), satellitePanelPartialFanFailure(7560), satellitePanelFANManufacturingDataMemoryEEPROMFailure(7565), satellitePanelFANUnitIsMissing(7570), satellitePanelIndustrialHighTemperature(7575), satellitePanelHighTemperature(7580), satellitePanelBatteryFailureA(7585), plannedSwitchOver(7590), protectionCardConfigurationMismatch(7595), routerProcessorSwitchOver(7600), runningLowOnResources(7605), noMoreResourcesAreAvailable(7610), esmcFailure(7615), licenseWillExpireWithin24Hours(7620), licenseWillExpireAnytimeAfter1DayButBefore14Days(7625), licenseIsExpired(7630), licenseCountViolation(7635), temporaryLicenseIsInUse(7640), evaluationLicenseIsInUse(7645), licenseIsMissing(7650), pseudowireDown(7655), workingPseudowireControlPlaneDown(7660), protectPseudowireControlPlaneDown(7665), workingPseudowireConnectivityCheckDown(7670), protectPseudowireConnectivityCheckDown(7675), pseudowireTrafficSwitchedToProtection(7680), workingPseudowireLocalAcTxPortFault(7685), protectPseudowireLocalAcTxPortFault(7690), workingPseudowireLocalAcRxPortFault(7695), protectPseudowireLocalAcRxPortFault(7700), workingPseudowireRemoteAcTxPortFault(7705), protectPseudowireRemoteAcTxPortFault(7710), workingPseudowireRemoteAcRxPortFault(7715), protectPseudowireRemoteAcRxPortFault(7720), slaThresholdCrossAlert(7725), protectLocalPseudowireNotForwarding(7730), workingPseudowireNotForwarding(7735), protectPseudowireNotForwarding(7740), tpTunnelDown(7745), workingLabelSwitchedPathDown(7750), protectLabelSwitchedPathDown(7755), workingLabelSwitchedPathAlarmIndicationSignal(7760), protectLabelSwitchedPathAlarmIndicationSignal(7765), workingLabelSwitchedPathRemoteDefectIndication(7770), protectLabelSwitchedPathRemoteDefectIndication(7775), bidirectionalForwardDetectionDown(7780), tpTrafficSwitchedFromWorkingToProtection(7785), workingTpLockout(7790), protectTpLockout(7795), ethernetFlowPointFailed(7800), teTunnelDown(7805), macSystemLimitReached(7810), macBridgeDomainLimitReached(7815), autoSensingDisabled(7820), smBackwardIncomingAlignmentError(7825), resourceAllocationFailed(7830), lossOfDFBSignal(7835), workingLabelSwitchedPathLinkDownIndication(7840), protectLabelSwitchedPathLinkDownIndication(7845), workingLabelSwitchedPathLockReport(7850), protectLabelSwitchedPathLockReport(7855), satellitePanelBatteryFailureB(7860), highBitErrorRate(7865), backPanelFacilityLoopback(7870), backPanelTerminalLoopback(7875), trunkPayloadTypeMismatch(7880), invalidMuxponderConfiguration(7885), coolingProfileMismatch(7890), trunkOduAlarmIndicationSignal(7895), companionCardMissing(7900), controlPlaneUnverifiedClearedAlarmsPresent(7905), powerConsumptionLimitHasCrossed(7910), masterKeyExchangeFailed(7915), unitHighTemperature(7930), overTemperatureUnitProtected(7935), seqMismatchCount(7945), keyProgramOnAlteraFpgaFailed(7960), duplicateNodeControllerDetected(7970), restorationInProg(7975), ramanPumpsCalibrationProcedureIsRunning(7980), ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes(7985), odukTCM1AlarmIndicationSignal(13100), odukTCM2AlarmIndicationSignal(13105), odukLockedDefectTCM1(13110), odukLockedDefectTCM2(13115), otukLossOfFrame(13120), odukOpenConnectionIndicationTCM1(13125), odukOpenConnectionIndicationTCM2(13130), odukTrailTraceIdentifierMismatchTCM1(13135), odukTrailTraceIdentifierMismatchTCM2(13140), odukSignalFailureTCM1(13145), odukSignalFailureTCM2(13150), odukSignalDegradeTCM1(13155), odukSignalDegradeTCM2(13160), lossOfChannel(13165), fecMismatch(13170), timSectionMonitorTraceIdentifierMismatchFailure(13175), automaticLaserShutdown(13180), shutterInsertionLossVariationDegradeLow(13200), opticalChannelDeactivationFailure(13205), shutterInsertionLossVariationDegradeHigh(13210), networkTopologyIncomplete(13215), pluginModuleCommunicationFailure(13220), opticalNetworkTypeMismatch(13225), opticalPowerDegradeLow(13230), automaticPowerControlFailure(13235), opticalPowerDegradeHigh(13240), automaticPowerControlDisabled(13245), opticalPowerFailureLow(13250), ringIdMismatch(13255), opticalPowerFailureHigh(13260), lossOfContinuity(13270), variableOpticalAttenuatorDegradeLow(13280), variableOpticalAttenuatorDegradeHigh(13290), variableOpticalAttenuatorFailureLow(13300), variableOpticalAttenuatorFailureHigh(13310), laserBiasDegrade(13320), laserBiasFailure(13330), laserTemperatureDegrade(13340), opticalAmplifierGainDegradeLow(13350), opticalAmplifierGainDegradeHigh(13360), opticalAmplifierGainFailureLow(13370), opticalAmplifierGainFailureHigh(13380), opticalChannelConnectionFailure(13390), opticalChannelIncomplete(13395), opticalChannelActivationFailure(13400), laserAutoPowerReduction(13410), caseTemperatureDegrade(13420), fiberTemperatureDegrade(13430), shutterOpen(13440), awgTemperatureDegrade(13450), awgTemperatureFailure(13460), awgOverTemperature(13470), opticalAmplifierInitialization(13480), awgWarmUp(13490), incSigloss(13510), incSyncloss(13515), incGfpOutOfFrame(13520), incGfpSigLoss(13525), incGfpSyncLoss(13530)
Cerent454EntityClassunknownEntity(1), ne(10), backplane(30), eqpt(50), port(60), ocn(70), stmn(71), aip(80), fanTray(90), crs(100), ds3(110), almExpPanel(120), almIfExtnsn(130), stsMon(140), vcMonHp(141), dwdmClient(150), stsTerm(160), vcTermHp(161), dwdmTrunk(170), dwdmOptics(180), psSts(190), rsms(200), xcSts(210), bits(220), dwdmFec(230), neSynchRef(240), dwdm8b10b(250), extSynchRef(260), dwdmOtn(270), envAlrm(280), envCtrl(290), neRing(360), ds1(390), vtMon(410), vcMonLp(411), vtTerm(420), vcTermLP(421), fUdc(430), msUdc(440), spareSdcc(450), ucpCircuit(480), ucpIpcc(490), ucpNeighbor(500), ec1(510), ps(520), psVt(530), e100t(540), e1000t(550), etherBridge(560), e1(600), e3(630), e4(640), stm1E(650), ds3i(660), g1000(670), ml100t(680), ml1000(690), dwdmSfp(700), dwdmScl(710), dwdmTcm1(720), dwdmTcm2(730), dwdmOcn(740), dwdmSm(750), dwdmPm(760), dwdmTcm(770), pwr(780), stsTermVcat(790), vtTermVcat(800), vcatGroup(810), fcmr(820), entOptics(830), ce100t(840), ppm(850), twor(860), isc(870), escon(880), bic(890), gfp(900), gige(910), pos(920), cap(930), dwdmData(940), logFac(950), ge(960), fc(970), ec1p1(980), mlFx(990), ochTerm(1000), shelf(1010), ce1000(1020), cemr(1030), lmp(1040), lmpControlChannel(1050), lmpTeLink(1060), lmpDataLink(1070), rpr(1080), ether(1090), mlmr(1100), otu(1110), aots(3200), ots(3210), oms(3220), och(3230), osc(3240), ochnc(3250), ib(3260), chgrp(3270), hdlc(3280), msISC(3290), ecu(3300), lcdFlash(3310), usb(3320), fe(3330), odu0(3350), odu1(3360)

Objects

cerent454MibModule .1.3.6.1.4.1.3607.1.10.20
cerent454Mib .1.3.6.1.4.1.3607.6.10
cerent454Conformance .1.3.6.1.4.1.3607.6.10.10
cerent454Groups .1.3.6.1.4.1.3607.6.10.10.10
cerent454Compliance .1.3.6.1.4.1.3607.6.10.10.20
cerentCommonObjects .1.3.6.1.4.1.3607.6.10.100
cerent454CommonObjectsGroup .1.3.6.1.4.1.3607.6.10.100.10
cerent454EnableNotification
.1.3.6.1.4.1.3607.6.10.100.10.10
cerent454NodeTime
.1.3.6.1.4.1.3607.6.10.100.10.20
cerent454SentNotifications
.1.3.6.1.4.1.3607.6.10.100.10.30
cerent454LastChangeTime
.1.3.6.1.4.1.3607.6.10.100.10.40
cerent454MultishelfEnabled
.1.3.6.1.4.1.3607.6.10.100.10.50
cerent454Objects .1.3.6.1.4.1.3607.6.10.20
cerent454GeneralGroup .1.3.6.1.4.1.3607.6.10.20.20
cerent454SoftwareVersion
.1.3.6.1.4.1.3607.6.10.20.20.10
cerent454AlarmGroup .1.3.6.1.4.1.3607.6.10.20.30
cerent454AlarmCount .1.3.6.1.4.1.3607.6.10.20.30.10
cerent454AlarmTable .1.3.6.1.4.1.3607.6.10.20.30.20
cerent454AlarmEntry .1.3.6.1.4.1.3607.6.10.20.30.20.1
cerent454AlarmIndex .1.3.6.1.4.1.3607.6.10.20.30.20.1.10
cerent454AlarmObjectName
.1.3.6.1.4.1.3607.6.10.20.30.20.1.100
cerent454AlarmAdditionalInfo
.1.3.6.1.4.1.3607.6.10.20.30.20.1.110
cerent454AlarmSeverity
.1.3.6.1.4.1.3607.6.10.20.30.20.1.120
cerent454AlarmStatus
.1.3.6.1.4.1.3607.6.10.20.30.20.1.130
cerent454AlarmServiceAffecting
.1.3.6.1.4.1.3607.6.10.20.30.20.1.140
cerent454AlarmObjectType .1.3.6.1.4.1.3607.6.10.20.30.20.1.20
cerent454AlarmSlotNumber .1.3.6.1.4.1.3607.6.10.20.30.20.1.30
cerent454AlarmPortNumber
.1.3.6.1.4.1.3607.6.10.20.30.20.1.40
cerent454AlarmLineNumber .1.3.6.1.4.1.3607.6.10.20.30.20.1.50
cerent454AlarmObjectIndex .1.3.6.1.4.1.3607.6.10.20.30.20.1.60
cerent454AlarmType .1.3.6.1.4.1.3607.6.10.20.30.20.1.70
cerent454AlarmState
.1.3.6.1.4.1.3607.6.10.20.30.20.1.80
cerent454AlarmTimeStamp
.1.3.6.1.4.1.3607.6.10.20.30.20.1.90
cerent454ReportedAlarmCount .1.3.6.1.4.1.3607.6.10.20.30.30
cerent454ReportedAlarmTable .1.3.6.1.4.1.3607.6.10.20.30.40
cerent454ReportedAlarmEntry .1.3.6.1.4.1.3607.6.10.20.30.40.1
cerent454ReportedAlarmIndex .1.3.6.1.4.1.3607.6.10.20.30.40.1.10
cerent454ReportedAlarmSeverity
.1.3.6.1.4.1.3607.6.10.20.30.40.1.100
cerent454ReportedAlarmStatus
.1.3.6.1.4.1.3607.6.10.20.30.40.1.110
cerent454ReportedAlarmServiceAffecting
.1.3.6.1.4.1.3607.6.10.20.30.40.1.120
cerent454ReportedAlarmObjectType .1.3.6.1.4.1.3607.6.10.20.30.40.1.20
cerent454ReportedAlarmSlotNumber .1.3.6.1.4.1.3607.6.10.20.30.40.1.30
cerent454ReportedAlarmPortNumber
.1.3.6.1.4.1.3607.6.10.20.30.40.1.40
cerent454ReportedAlarmObjectIndex .1.3.6.1.4.1.3607.6.10.20.30.40.1.50
cerent454ReportedAlarmType .1.3.6.1.4.1.3607.6.10.20.30.40.1.60
cerent454ReportedAlarmTimeStamp
.1.3.6.1.4.1.3607.6.10.20.30.40.1.70
cerent454ReportedAlarmObjectName
.1.3.6.1.4.1.3607.6.10.20.30.40.1.80
cerent454ReportedAlarmAdditionalInfo
.1.3.6.1.4.1.3607.6.10.20.30.40.1.90
cerent454ThresholdGroup .1.3.6.1.4.1.3607.6.10.20.40
cerent454ThresholdTable .1.3.6.1.4.1.3607.6.10.20.40.10
cerent454ThresholdEntry .1.3.6.1.4.1.3607.6.10.20.40.10.1
cerent454ThresholdIndex .1.3.6.1.4.1.3607.6.10.20.40.10.1.10
cerent454ThresholdMonitorType
.1.3.6.1.4.1.3607.6.10.20.40.10.1.20
cerent454ThresholdLocation
.1.3.6.1.4.1.3607.6.10.20.40.10.1.30
cerent454ThresholdPeriod
.1.3.6.1.4.1.3607.6.10.20.40.10.1.40
cerent454ThresholdSetValue .1.3.6.1.4.1.3607.6.10.20.40.10.1.50
cerent454ThresholdCurrentValue .1.3.6.1.4.1.3607.6.10.20.40.10.1.60
cerent454ThresholdDetectType .1.3.6.1.4.1.3607.6.10.20.40.10.1.70
cerentCommonEvents .1.3.6.1.4.1.3607.6.10.200
cerent454Events .1.3.6.1.4.1.3607.6.10.30
cerent454V2Events .1.3.6.1.4.1.3607.6.10.30.0

Notifications/Traps

NameOIDDescription
alarmUnknown











.1.3.6.1.4.1.3607.6.10.30.0.1
alarm unknown
alarmCutoffIsInManualMode











.1.3.6.1.4.1.3607.6.10.30.0.10
alarm cutoff is in manual mode
alarmIndicationSignalVT











.1.3.6.1.4.1.3607.6.10.30.0.100
alarm indication signal VT
controlBus2Failure











.1.3.6.1.4.1.3607.6.10.30.0.1000
Control Bus 2 Failure
tccAToShelfSlot1DROP1CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1010
TCC A To Shelf Slot 1 (DROP 1) Communication Failure
tccAToShelfSlot2DROP2CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1020
TCC A To Shelf Slot 2 (DROP 2) Communication Failure
tccAToShelfSlot3DROP3CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1030
TCC A To Shelf Slot 3 (DROP 3) Communication Failure
tccAToShelfSlot4DROP4CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1040
TCC A To Shelf Slot 4 (DROP 4) Communication Failure
tccAToShelfSlot5TRUNK1CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1050
TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure
tccAToShelfSlot6TRUNK2CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1060
TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure
tccAToShelfSlot7TCCACommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1070
TCC A To Shelf Slot 7 (TCC A) Communication Failure
tccAToShelfSlot8XCONACommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1080
TCC A To Shelf Slot 8 (XCON A) Communication Failure
tccAToShelfSlot9AICCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1090
TCC A To Shelf Slot 9 (AIC) Communication Failure
apsChannelFailure











.1.3.6.1.4.1.3607.6.10.30.0.110
APS Channel Failure
tccAToShelfSlot10XCONBCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1100
TCC A To Shelf Slot 10 (XCON B) Communication Failure
tccAToShelfSlot11TCCBCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1110
TCC A To Shelf Slot 11 (TCC B) Communication Failure
tccAToShelfSlot12TRUNK3CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1120
TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure
tccAToShelfSlot13TRUNK4CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1130
TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure
tccAToShelfSlot14DROP5CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1140
TCC A To Shelf Slot 14 (DROP 5) Communication Failure
tccAToShelfSlot15DROP6CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1150
TCC A To Shelf Slot 15 (DROP 6) Communication Failure
tccAToShelfSlot16DROP7CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1160
TCC A To Shelf Slot 16 (DROP 7) Communication Failure
tccAToShelfSlot17DROP8CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1170
TCC A To Shelf Slot 17 (DROP 8) Communication Failure
tccAToDCCAProcessorCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1180
communication failure TCC A to DCC A processor
tccBToShelfSlot1DROP1CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1190
TCC B To Shelf Slot 1 (DROP 1) Communication Failure
channelByteFailureAPS











.1.3.6.1.4.1.3607.6.10.30.0.120
channel Byte failure APS
tccBToShelfSlot2DROP2CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1200
TCC B To Shelf Slot 2 (DROP 2) Communication Failure
tccBToShelfSlot3DROP3CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1210
TCC B To Shelf Slot 3 (DROP 3) Communication Failure
tccBToShelfSlot4DROP4CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1220
TCC B To Shelf Slot 4 (DROP 4) Communication Failure
tccBToShelfSlot5TRUNK1CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1230
TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure
tccBToShelfSlot6TRUNK2CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1240
TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure
tccBToShelfSlot7TCCACommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1250
TCC B To Shelf Slot 7 (TCC A) Communication Failure
tccBToShelfSlot8XCONACommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1260
TCC B To Shelf Slot 8 (XCON A) Communication Failure
tccBToShelfSlot9AICCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1270
TCC B To Shelf Slot 9 (AIC) Communication Failure
tccBToShelfSlot10XCONBCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1280
TCC B To Shelf Slot 10 (XCON B) Communication Failure
tccBToShelfSlot11TCCBCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1290
TCC B To Shelf Slot 11 (TCC B) Communication Failure
channelProtectionSwitchingChannelMatchFailureAPS











.1.3.6.1.4.1.3607.6.10.30.0.130
channel Protection Switching Channel Match failure APS
tccBToShelfSlot12TRUNK3CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1300
TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure
tccBToShelfSlot13TRUNK4CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1310
TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure
odukTCM1AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.13100
ODUk: TCM1 Alarm Indication Signal
odukTCM2AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.13105
ODUk: TCM2 Alarm Indication Signal
odukLockedDefectTCM1











.1.3.6.1.4.1.3607.6.10.30.0.13110
ODUk Locked Defect - TCM1
odukLockedDefectTCM2











.1.3.6.1.4.1.3607.6.10.30.0.13115
ODUk Locked Defect - TCM2
otukLossOfFrame











.1.3.6.1.4.1.3607.6.10.30.0.13120
OTUk: Loss Of Frame
odukOpenConnectionIndicationTCM1











.1.3.6.1.4.1.3607.6.10.30.0.13125
ODUk Open Connection Indication TCM1
odukOpenConnectionIndicationTCM2











.1.3.6.1.4.1.3607.6.10.30.0.13130
ODUk Open Connection Indication TCM2
odukTrailTraceIdentifierMismatchTCM1











.1.3.6.1.4.1.3607.6.10.30.0.13135
ODUk Trail Trace Identifier Mismatch TCM1
odukTrailTraceIdentifierMismatchTCM2











.1.3.6.1.4.1.3607.6.10.30.0.13140
ODUk Trail Trace Identifier Mismatch TCM2
odukSignalFailureTCM1











.1.3.6.1.4.1.3607.6.10.30.0.13145
ODUk Signal Failure - TCM1
odukSignalFailureTCM2











.1.3.6.1.4.1.3607.6.10.30.0.13150
ODUk Signal Failure - TCM2
odukSignalDegradeTCM1











.1.3.6.1.4.1.3607.6.10.30.0.13155
ODUk Signal Degrade - TCM1
odukSignalDegradeTCM2











.1.3.6.1.4.1.3607.6.10.30.0.13160
ODUk Signal Degrade - TCM2
lossOfChannel











.1.3.6.1.4.1.3607.6.10.30.0.13165
Loss of Channel
fecMismatch











.1.3.6.1.4.1.3607.6.10.30.0.13170
FEC Mismatch
timSectionMonitorTraceIdentifierMismatchFailure











.1.3.6.1.4.1.3607.6.10.30.0.13175
TIM Section Monitor - Trace Identifier Mismatch Failure
automaticLaserShutdown











.1.3.6.1.4.1.3607.6.10.30.0.13180
Automatic Laser Shutdown
tccBToShelfSlot14DROP5CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1320
TCC B To Shelf Slot 14 (DROP 5) Communication Failure
shutterInsertionLossVariationDegradeLow











.1.3.6.1.4.1.3607.6.10.30.0.13200
Shutter Insertion Loss Variation Degrade Low
opticalChannelDeactivationFailure











.1.3.6.1.4.1.3607.6.10.30.0.13205
Optical Channel de-activation failure
shutterInsertionLossVariationDegradeHigh











.1.3.6.1.4.1.3607.6.10.30.0.13210
Shutter Insertion Loss Variation Degrade High
networkTopologyIncomplete











.1.3.6.1.4.1.3607.6.10.30.0.13215
Network Topology Incomplete
pluginModuleCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.13220
Plug-in Module Communication Failure
opticalNetworkTypeMismatch











.1.3.6.1.4.1.3607.6.10.30.0.13225
Optical Network Type Mismatch
opticalPowerDegradeLow











.1.3.6.1.4.1.3607.6.10.30.0.13230
Optical Power Degrade Low
automaticPowerControlFailure











.1.3.6.1.4.1.3607.6.10.30.0.13235
Automatic Power Control Failure
opticalPowerDegradeHigh











.1.3.6.1.4.1.3607.6.10.30.0.13240
Optical Power Degrade High
automaticPowerControlDisabled











.1.3.6.1.4.1.3607.6.10.30.0.13245
Automatic Power Control Disabled
opticalPowerFailureLow











.1.3.6.1.4.1.3607.6.10.30.0.13250
Optical Power Failure Low
ringIdMismatch











.1.3.6.1.4.1.3607.6.10.30.0.13255
Ring Id Mismatch
opticalPowerFailureHigh











.1.3.6.1.4.1.3607.6.10.30.0.13260
Optical Power Failure High
lossOfContinuity











.1.3.6.1.4.1.3607.6.10.30.0.13270
Loss Of Continuity
variableOpticalAttenuatorDegradeLow











.1.3.6.1.4.1.3607.6.10.30.0.13280
Variable Optical Attenuator Degrade Low
variableOpticalAttenuatorDegradeHigh











.1.3.6.1.4.1.3607.6.10.30.0.13290
Variable Optical Attenuator Degrade High
tccBToShelfSlot15DROP6CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1330
TCC B To Shelf Slot 15 (DROP 6) Communication Failure
variableOpticalAttenuatorFailureLow











.1.3.6.1.4.1.3607.6.10.30.0.13300
Variable Optical Attenuator Failure Low
variableOpticalAttenuatorFailureHigh











.1.3.6.1.4.1.3607.6.10.30.0.13310
Variable Optical Attenuator Failure High
laserBiasDegrade











.1.3.6.1.4.1.3607.6.10.30.0.13320
Laser Bias Degrade
laserBiasFailure











.1.3.6.1.4.1.3607.6.10.30.0.13330
aser Bias Failure
laserTemperatureDegrade











.1.3.6.1.4.1.3607.6.10.30.0.13340
Laser Temperature Degrade
opticalAmplifierGainDegradeLow











.1.3.6.1.4.1.3607.6.10.30.0.13350
Optical Amplifier Gain Degrade Low
opticalAmplifierGainDegradeHigh











.1.3.6.1.4.1.3607.6.10.30.0.13360
Optical Amplifier Gain Degrade High
opticalAmplifierGainFailureLow











.1.3.6.1.4.1.3607.6.10.30.0.13370
Optical Amplifier Gain Failure Low
opticalAmplifierGainFailureHigh











.1.3.6.1.4.1.3607.6.10.30.0.13380
Optical Amplifier Gain Failure High
opticalChannelConnectionFailure











.1.3.6.1.4.1.3607.6.10.30.0.13390
Optical Channel connection failure
opticalChannelIncomplete











.1.3.6.1.4.1.3607.6.10.30.0.13395
Optical Channel Incomplete
tccBToShelfSlot16DROP7CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1340
TCC B To Shelf Slot 16 (DROP 7) Communication Failure
opticalChannelActivationFailure











.1.3.6.1.4.1.3607.6.10.30.0.13400
Optical Channel activation failure
laserAutoPowerReduction











.1.3.6.1.4.1.3607.6.10.30.0.13410
Laser Auto Power Reduction
caseTemperatureDegrade











.1.3.6.1.4.1.3607.6.10.30.0.13420
Case Temperature Degrade
fiberTemperatureDegrade











.1.3.6.1.4.1.3607.6.10.30.0.13430
Fiber Temperature Degrade
shutterOpen











.1.3.6.1.4.1.3607.6.10.30.0.13440
Shutter Open
awgTemperatureDegrade











.1.3.6.1.4.1.3607.6.10.30.0.13450
AWG Temperature Degrade
awgTemperatureFailure











.1.3.6.1.4.1.3607.6.10.30.0.13460
AWG Temperature Failure
awgOverTemperature











.1.3.6.1.4.1.3607.6.10.30.0.13470
AWG Over-Temperature
opticalAmplifierInitialization











.1.3.6.1.4.1.3607.6.10.30.0.13480
Optical Amplifier Initialization
awgWarmUp











.1.3.6.1.4.1.3607.6.10.30.0.13490
AWG Warm Up
tccBToShelfSlot17DROP8CommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1350
TCC B To Shelf Slot 17 (DROP 8) Communication Failure
incSigloss











.1.3.6.1.4.1.3607.6.10.30.0.13510
Incoming Signal Loss on Fibre Channel Interface
incSyncloss











.1.3.6.1.4.1.3607.6.10.30.0.13515
Incoming Synchronization Loss on Fibre Channel Interface
incGfpOutOfFrame











.1.3.6.1.4.1.3607.6.10.30.0.13520
Out Of Frame Detected by GFP Receiver
incGfpSigLoss











.1.3.6.1.4.1.3607.6.10.30.0.13525
Client Signal Loss Frames Detected by GFP Receiver
incGfpSyncLoss











.1.3.6.1.4.1.3607.6.10.30.0.13530
Client Sychronization Loss Frames Detected by GFP Receiver
tccBToDCCBProcessorCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.1360
TCC B To DCC B Processor Communication Failure
controlEquipmentControlCommunicationsEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1370
control Equipment Control Communications equipment failure
controlProcessorFailure











.1.3.6.1.4.1.3607.6.10.30.0.1380
Control Processor Failure
workingMemoryFailure











.1.3.6.1.4.1.3607.6.10.30.0.1390
Working Memory Failure
channelAutomaticProtectionSwitchModeMismatchAPS











.1.3.6.1.4.1.3607.6.10.30.0.140
channel Automatic Protection Switch Mode Mismatch APS
interconnectionEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1400
interconnection Equipment failure
payloadBusFailureToIOSlot1XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1410
Payload Bus Failure To IO Slot 1 (XCON Slot 8)
payloadBusFailureToIOSlot2XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1420
Payload Bus Failure To IO Slot 2 (XCON Slot 8)
payloadBusFailureToIOSlot3XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1430
Payload Bus Failure To IO Slot 3 (XCON Slot 8)
payloadBusFailureToIOSlot4XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1440
Payload Bus Failure To IO Slot 4 (XCON Slot 8)
payloadBusFailureToIOSlot5XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1450
Payload Bus Failure To IO Slot 5 (XCON Slot 8)
payloadBusFailureToIOSlot6XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1460
Payload Bus Failure To IO Slot 6 (XCON Slot 8)
payloadBusFailureToIOSlot12XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1470
Payload Bus Failure To IO Slot 12 (XCON Slot 8)
payloadBusFailureToIOSlot13XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1480
Payload Bus Failure To IO Slot 13 (XCON Slot 8)
payloadBusFailureToIOSlot14XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1490
Payload Bus Failure To IO Slot 14 (XCON Slot 8)
farEndProtectionLineFailure











.1.3.6.1.4.1.3607.6.10.30.0.150
Far End Protection Line Failure
payloadBusFailureToIOSlot15XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1500
Payload Bus Failure To IO Slot 15 (XCON Slot 8)
payloadBusFailureToIOSlot16XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1510
Payload Bus Failure To IO Slot 16 (XCON Slot 8)
payloadBusFailureToIOSlot17XCONSlot8











.1.3.6.1.4.1.3607.6.10.30.0.1520
Payload Bus Failure To IO Slot 17 (XCON Slot 8)
payloadBusFailureToIOSlot1XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1530
Payload Bus Failure To IO Slot 1 (XCON Slot 10)
payloadBusFailureToIOSlot2XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1540
Payload Bus Failure To IO Slot 2 (XCON Slot 10)
payloadBusFailureToIOSlot3XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1550
Payload Bus Failure To IO Slot 3 (XCON Slot 10)
payloadBusFailureToIOSlot4XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1560
Payload Bus Failure To IO Slot 4 (XCON Slot 10)
payloadBusFailureToIOSlot5XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1570
Payload Bus Failure To IO Slot 5 (XCON Slot 10)
payloadBusFailureToIOSlot6XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1580
Payload Bus Failure To IO Slot 6 (XCON Slot 10)
payloadBusFailureToIOSlot12XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1590
Payload Bus Failure To IO Slot 12 (XCON Slot 10)
inconsistentAPSCode











.1.3.6.1.4.1.3607.6.10.30.0.160
Inconsistent APS code
payloadBusFailureToIOSlot13XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1600
Payload Bus Failure To IO Slot 13 (XCON Slot 10)
payloadBusFailureToIOSlot14XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1610
Payload Bus Failure To IO Slot 14 (XCON Slot 10)
payloadBusFailureToIOSlot15XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1620
Payload Bus Failure To IO Slot 15 (XCON Slot 10)
payloadBusFailureToIOSlot16XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1630
Payload Bus Failure To IO Slot 16 (XCON Slot 10)
payloadBusFailureToIOSlot17XCONSlot10











.1.3.6.1.4.1.3607.6.10.30.0.1640
Payload Bus Failure To IO Slot 17 (XCON Slot 10)
timeSlotInterchangeEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1650
Time Slot Interchange Equipment Failure
equipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1660
equipment failure
highTemperature











.1.3.6.1.4.1.3607.6.10.30.0.1670
High Temperature
invalidMACAddress











.1.3.6.1.4.1.3607.6.10.30.0.1680
Invalid MAC Address
boardFailure











.1.3.6.1.4.1.3607.6.10.30.0.1690
Board Failure
improperAPSCode











.1.3.6.1.4.1.3607.6.10.30.0.170
Improper APS code
diagnosticFailure











.1.3.6.1.4.1.3607.6.10.30.0.1700
equipment failure Diagnostics Failure
mediumAccessControlFailure











.1.3.6.1.4.1.3607.6.10.30.0.1710
Medium Access Control Failure
facilityTerminationEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1720
facility Termination equipment failure
automaticLaserShutoffDueToHighTemperature











.1.3.6.1.4.1.3607.6.10.30.0.1730
Automatic Laser Shutoff Due To High Temperature
failureToReleaseFromProtection











.1.3.6.1.4.1.3607.6.10.30.0.1740
failure To Release from protection
receiverFailure











.1.3.6.1.4.1.3607.6.10.30.0.1750
Receiver Failure
transmitFailure











.1.3.6.1.4.1.3607.6.10.30.0.1760
Transmit Failure
facilityTerminationEquipmentReceiverMissing











.1.3.6.1.4.1.3607.6.10.30.0.1770
facility Termination equipment Receiver missing
facilityTerminationEquipmentTransmitterMissing











.1.3.6.1.4.1.3607.6.10.30.0.1780
facility Termination equipment Transmitter missing
failureToSwitchToProtection











.1.3.6.1.4.1.3607.6.10.30.0.1790
failure To Switch to protection
nodeIdMismatch











.1.3.6.1.4.1.3607.6.10.30.0.180
Node Id Mismatch APS
failureToSwitchToProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.1800
failure To Switch to protection Ring
failureToSwitchToProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.1810
failure To Switch to protection Span
failureToSwitchToProtectionPath











.1.3.6.1.4.1.3607.6.10.30.0.1820
failure to Switch to protection Path
fanFailure











.1.3.6.1.4.1.3607.6.10.30.0.1830
Fan Failure
equipmentUnitPlugIn











.1.3.6.1.4.1.3607.6.10.30.0.1840
equipment unit plug in
nePowerFailureAtConnector











.1.3.6.1.4.1.3607.6.10.30.0.1850
NE Power Failure At Connector
fuseAlarm











.1.3.6.1.4.1.3607.6.10.30.0.1860
Fuse Alarm
synchronizationUnitFailure











.1.3.6.1.4.1.3607.6.10.30.0.1870
synchronization unit failure
synchronizationSwitchingEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.1880
synchronization switching Equipment failure
equipmentUnitUnplugged











.1.3.6.1.4.1.3607.6.10.30.0.1890
Equipment Unit Un-plugged
channelDefaultKAPS











.1.3.6.1.4.1.3607.6.10.30.0.190
channel Default K APS
loopback











.1.3.6.1.4.1.3607.6.10.30.0.1900
loop back
ds1LoopbackDueToFEACCommand











.1.3.6.1.4.1.3607.6.10.30.0.1910
DS1 Loopback Due To FEAC Command
loopbackCommandSentToFarEndDS1











.1.3.6.1.4.1.3607.6.10.30.0.1920
loopback Command sent to Far End DS1
ds3LoopbackDueToFEACCommand











.1.3.6.1.4.1.3607.6.10.30.0.1930
loopback due to FEAC command DS3
ds3LoopbackCommandSentToFarEnd











.1.3.6.1.4.1.3607.6.10.30.0.1940
DS3 Loopback Command Sent To Far End
ds2LoopbackDueToFarEndCommand











.1.3.6.1.4.1.3607.6.10.30.0.1950
DS2 Loopback Due To Far End Command
ds2LoopbackCommandSentToFarEnd











.1.3.6.1.4.1.3607.6.10.30.0.1960
DS2 Loopback Command Sent To Far End
facilityLoopback











.1.3.6.1.4.1.3607.6.10.30.0.1970
Facility Loopback
networkLoopback











.1.3.6.1.4.1.3607.6.10.30.0.1980
Network Loopback
terminalLoopback











.1.3.6.1.4.1.3607.6.10.30.0.1990
Terminal Loopback
failureDetectedExternalToTheNE












.1.3.6.1.4.1.3607.6.10.30.0.20
failure detected External to the NE
connectionLoss











.1.3.6.1.4.1.3607.6.10.30.0.200
Connection loss APS
manuallyCausedAbnormalCondition











.1.3.6.1.4.1.3607.6.10.30.0.2000
manually caused abnormal condition
ethernetBridgeIsNewRootOfSpanningTree











.1.3.6.1.4.1.3607.6.10.30.0.2010
Ethernet Bridge Is New Root Of Spanning Tree
ethernetBridgeTopologyChange











.1.3.6.1.4.1.3607.6.10.30.0.2020
Ethernet Bridge Topology Change
normalCondition











.1.3.6.1.4.1.3607.6.10.30.0.2030
normal condition
embeddedOperationsChannelFailureLinkDown











.1.3.6.1.4.1.3607.6.10.30.0.2040
embedded Operations Channel failure link down
peerStateMismatch











.1.3.6.1.4.1.3607.6.10.30.0.2050
peer state mismatch
proceduralError











.1.3.6.1.4.1.3607.6.10.30.0.2060
procedural Error
improperRemoval











.1.3.6.1.4.1.3607.6.10.30.0.2070
Improper Removal
duplicateNodeID











.1.3.6.1.4.1.3607.6.10.30.0.2080
Duplicate Node ID
blsrOutOfSync











.1.3.6.1.4.1.3607.6.10.30.0.2090
BLSR out of sync
bipolarViolation











.1.3.6.1.4.1.3607.6.10.30.0.210
bipolar Violation
blsrMultiNodeTableUpdateCompleted











.1.3.6.1.4.1.3607.6.10.30.0.2100
BLSR Multi-Node Table Update Completed
protectionUnitNotAvailable











.1.3.6.1.4.1.3607.6.10.30.0.2110
protection unit not available
performanceMonitorThresholdCrossingAlert

















.1.3.6.1.4.1.3607.6.10.30.0.2120
performance Monitor Threshold Crossing Alert
protectionSwitch











.1.3.6.1.4.1.3607.6.10.30.0.2130
Protection Switch
recoveryOrServiceProtectionActionHasBeenInitiated











.1.3.6.1.4.1.3607.6.10.30.0.2140
recovery or service protection action has been initiated
automaticSystemReset











.1.3.6.1.4.1.3607.6.10.30.0.2150
automatic system Reset
automaticUPSRSwitchCausedByAIS











.1.3.6.1.4.1.3607.6.10.30.0.2160
automatic UPSR switch caused by AIS
automaticUPSRSwitchCausedByLOP











.1.3.6.1.4.1.3607.6.10.30.0.2170
automatic UPSR switch caused by Lop
automaticUPSRSwitchCausedByUNEQ











.1.3.6.1.4.1.3607.6.10.30.0.2180
Automatic UPSR Switch Caused By UNEQ
automaticUPSRSwitchCausedByPDI











.1.3.6.1.4.1.3607.6.10.30.0.2190
automatic UPSR switch caused by PDI
carrierLossOnTheLAN











.1.3.6.1.4.1.3607.6.10.30.0.220
carrier Loss on the LAN
automaticUPSRSwitchCausedBySFBER











.1.3.6.1.4.1.3607.6.10.30.0.2200
Automatic UPSR Switch Caused By SFBER
automaticUPSRSwitchCausedBySDBER











.1.3.6.1.4.1.3607.6.10.30.0.2210
Automatic UPSR Switch Caused By SDBER
coldRestart











.1.3.6.1.4.1.3607.6.10.30.0.2220
cold Restart
forcedSwitchBackToWorking











.1.3.6.1.4.1.3607.6.10.30.0.2230
Forced Switch Back To Working
forcedSwitchBackToWorkingRing











.1.3.6.1.4.1.3607.6.10.30.0.2240
Forced Switch Back To Working - Ring
forcedSwitchBackToWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.2250
Forced Switch Back To Working - Span
forcedSwitchToProtection











.1.3.6.1.4.1.3607.6.10.30.0.2260
Forced Switch To Protection
forcedSwitchToProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2270
Forced Switch To Protection - Ring
forcedSwitchToProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.2280
Forced Switch To Protection - Span
workingFacilityOrEquipmentForcedToSwitchToProtectionPath











.1.3.6.1.4.1.3607.6.10.30.0.2290
Working Facility or Equipment Forced To Switch To Protection - Path
concatenationErrorSTS











.1.3.6.1.4.1.3607.6.10.30.0.230
concatenation error STS
initializationInitiated











.1.3.6.1.4.1.3607.6.10.30.0.2300
initialization initiated
lockoutOfProtection











.1.3.6.1.4.1.3607.6.10.30.0.2310
lockout of Protection
lockoutOfProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2320
lockout of Protection Ring
lockoutOfProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.2330
lockout of Protection Span
lockoutOfProtectionPath











.1.3.6.1.4.1.3607.6.10.30.0.2340
lockout of Protection Path
lockoutOfWorking











.1.3.6.1.4.1.3607.6.10.30.0.2350
lockout of working
lockoutOfWorkingRing











.1.3.6.1.4.1.3607.6.10.30.0.2360
lockout of working Ring
lockoutOfWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.2370
lockout of working Span
manualSystemReset











.1.3.6.1.4.1.3607.6.10.30.0.2380
manual system Reset
manualSwitchToInternalClock











.1.3.6.1.4.1.3607.6.10.30.0.2390
Manual Switch to Internal Clock
excessCollisionsOnTheLAN











.1.3.6.1.4.1.3607.6.10.30.0.240
excess collisions on the LAN
manualSwitchToPrimaryReference











.1.3.6.1.4.1.3607.6.10.30.0.2400
Manual Switch To Primary Reference
manualSwitchToSecondReference











.1.3.6.1.4.1.3607.6.10.30.0.2410
Manual Switch To Second Reference
manualSwitchToThirdReference











.1.3.6.1.4.1.3607.6.10.30.0.2420
Manual Switch To Third reference
manualSwitchToFourthReference











.1.3.6.1.4.1.3607.6.10.30.0.2430
Manual Switch To Fourth reference
manualSwitchToFifthReference











.1.3.6.1.4.1.3607.6.10.30.0.2440
Manual Switch To Fifth reference
manualSwitchToSixthReference











.1.3.6.1.4.1.3607.6.10.30.0.2450
Manual Switch To Sixth reference
manualSwitchBackToWorking











.1.3.6.1.4.1.3607.6.10.30.0.2460
Manual Switch Back To Working
manualSwitchBackToWorkingRing











.1.3.6.1.4.1.3607.6.10.30.0.2470
Manual Switch Back To Working - Ring
manualSwitchBackToWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.2480
Manual Switch Back To Working - Span
manualSwitchToProtection











.1.3.6.1.4.1.3607.6.10.30.0.2490
Manual Switch To Protection
facilityFailure











.1.3.6.1.4.1.3607.6.10.30.0.250
Facility Failure
manualSwitchToProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2500
Manual Switch To Protection - Ring
manualSwitchToProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.2510
Manual Switch To Protection - Span
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath











.1.3.6.1.4.1.3607.6.10.30.0.2520
Manual Switch Of Working Facility or Equipment To Protection - Path
powerfailRestart











.1.3.6.1.4.1.3607.6.10.30.0.2530
Powerfail Restart
ringIsSquelchingTraffic











.1.3.6.1.4.1.3607.6.10.30.0.2540
ring is squelching traffic
softwareDownloadInProgress











.1.3.6.1.4.1.3607.6.10.30.0.2550
software download in progress
switchToInternalClock











.1.3.6.1.4.1.3607.6.10.30.0.2560
Switch To Internal clock
switchToPrimaryReference











.1.3.6.1.4.1.3607.6.10.30.0.2570
Switch To Primary refernce
switchToSecondReference











.1.3.6.1.4.1.3607.6.10.30.0.2580
Switch To Second Reference
switchToThirdReference











.1.3.6.1.4.1.3607.6.10.30.0.2590
Switch To Third refernce
farEndAIS











.1.3.6.1.4.1.3607.6.10.30.0.260
far end AIS
switchToFourthReference











.1.3.6.1.4.1.3607.6.10.30.0.2600
Switch To Fourth refernce
switchToFifthReference











.1.3.6.1.4.1.3607.6.10.30.0.2610
Switch To Fifth refernce
switchToSixthReference











.1.3.6.1.4.1.3607.6.10.30.0.2620
Switch To Sixth refernce
systemReboot











.1.3.6.1.4.1.3607.6.10.30.0.2630
system reboot
switchedBackToWorking











.1.3.6.1.4.1.3607.6.10.30.0.2640
Switched Back To Working
switchedToProtection











.1.3.6.1.4.1.3607.6.10.30.0.2650
Switched To Protection
warmRestart











.1.3.6.1.4.1.3607.6.10.30.0.2660
warm Restart
ringIsInWaitToRestoreState











.1.3.6.1.4.1.3607.6.10.30.0.2670
Ring is in Wait To Restore state
manualSwitchRequest











.1.3.6.1.4.1.3607.6.10.30.0.2680
Manual Switch Request
forcedSwitchRequest











.1.3.6.1.4.1.3607.6.10.30.0.2690
Forced Switch Request
farEndMultipleDS1LOSDetectedOnDS3











.1.3.6.1.4.1.3607.6.10.30.0.270
far end Multiple DS1 LOS detected on DS3
lockoutSwitchRequest











.1.3.6.1.4.1.3607.6.10.30.0.2700
Lockout Switch Request
rmonHistoriesAndAlarmsResetReboot











.1.3.6.1.4.1.3607.6.10.30.0.2710
RMON Histories And Alarms Reset Reboot
rmonThresholdCrossingAlarm











.1.3.6.1.4.1.3607.6.10.30.0.2720
Crossing of Falling/Rising Threshold detected
alarmsSuppressedByUserCommand











.1.3.6.1.4.1.3607.6.10.30.0.2730
Alarms Suppressed By User Command
alarmsSuppressedForMaintenance











.1.3.6.1.4.1.3607.6.10.30.0.2740
Alarms Suppressed For Maintenance
switchingMatrixModuleFailure











.1.3.6.1.4.1.3607.6.10.30.0.2750
Switching Matrix Module Failure
lanConnectionPolarityReversed











.1.3.6.1.4.1.3607.6.10.30.0.2760
Lan Connection Polarity Reversed
autonomousPMReportMessageInhibited











.1.3.6.1.4.1.3607.6.10.30.0.2780
Autonomous PM Report Message Inhibited
ioSlotToXCONCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.2790
IO Slot To XCON Communication Failure
farEndDS1EqptFailNonServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.280
far end DS1 eqpt fail non service affecting
stsPathTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.2800
STS Path Trace Identifier Mismatch
nePowerFailureAtConnectorA











.1.3.6.1.4.1.3607.6.10.30.0.2810
NE Power Failure At Connector A
nePowerFailureAtConnectorB











.1.3.6.1.4.1.3607.6.10.30.0.2820
NE Power Failure At Connector B
freeMemoryOnCardVeryLow











.1.3.6.1.4.1.3607.6.10.30.0.2830
Free memory on the card is very low
freeMemoryOnCardNearZero











.1.3.6.1.4.1.3607.6.10.30.0.2840
Free memory on the card is near zero
exerciseRequestOnRing











.1.3.6.1.4.1.3607.6.10.30.0.2850
Exercise Request on Ring
exerciseRequestOnSpan











.1.3.6.1.4.1.3607.6.10.30.0.2860
Exercise Request on Span
squelchingPath











.1.3.6.1.4.1.3607.6.10.30.0.2870
Squelching Path
extraTrafficPreempted











.1.3.6.1.4.1.3607.6.10.30.0.2880
Extra Traffic Preempted.
farEndLockoutOfWorkingRing











.1.3.6.1.4.1.3607.6.10.30.0.2890
Far End Lockout of working - Ring.
farEndDS1EqptFailServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.290
far end DS1 Eqpt fail service affecting
farEndLockoutOfWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.2900
Far End Lockout of working - Span.
farEndLockoutOfProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2910
Far End Lockout of Protection - Ring.
farEndLockoutOfProtectionAllSpans











.1.3.6.1.4.1.3607.6.10.30.0.2920
Far End Lockout of Protection - All Spans.
farEndWorkingFacilityForcedToSwitchToProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2930
Far End Working Facility Forced To Switch To Protection - Ring
farEndWorkingFacilityForcedToSwitchToProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.2940
Far End Working Facility Forced To Switch To Protection - Span
farEndManualSwitchOfWorkingFacilityToProtectionRing











.1.3.6.1.4.1.3607.6.10.30.0.2950
Far End Manual Switch Of Working Facility To Protection - Ring
farEndManualSwitchOfWorkingFacilityToProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.2960
Far End Manual Switch Of Working Facility To Protection - Span
farEndExercisingRing











.1.3.6.1.4.1.3607.6.10.30.0.2970
Far End Exercising Ring
farEndExercisingSpan











.1.3.6.1.4.1.3607.6.10.30.0.2980
Far End Exercising Span
farEndBERThresholdPassedForSignalFailureRing











.1.3.6.1.4.1.3607.6.10.30.0.2990
Far End BER threshold passed for Signal Failure - Ring.
externalError











.1.3.6.1.4.1.3607.6.10.30.0.30
external error
farEndSingleDS1LOS











.1.3.6.1.4.1.3607.6.10.30.0.300
far end Single DS1 LOS
farEndBERThresholdPassedForSignalFailureSpan











.1.3.6.1.4.1.3607.6.10.30.0.3000
Far End BER threshold passed for Signal Failure - Span.
farEndBERThresholdPassedForSignalDegradeRing











.1.3.6.1.4.1.3607.6.10.30.0.3010
Far End BER threshold passed for Signal Degrade - Ring.
farEndBERThresholdPassedForSignalDegradeSpan











.1.3.6.1.4.1.3607.6.10.30.0.3020
Far End BER threshold passed for Signal Degrade - Span.
apsChannelFarEndProtectionLineSignalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.3030
APS Channel - Far End Protection Line Signal Degrade
ringSwitchIsActiveOnTheEastSide











.1.3.6.1.4.1.3607.6.10.30.0.3040
Ring Switch is active on the East Side.
ringSwitchIsActiveOnTheWestSide











.1.3.6.1.4.1.3607.6.10.30.0.3050
Ring Switch is active on the West Side.
spanSwitchIsActiveOnTheEastSide











.1.3.6.1.4.1.3607.6.10.30.0.3060
Span Switch is active on the East Side.
spanSwitchIsActiveOnTheWestSide











.1.3.6.1.4.1.3607.6.10.30.0.3070
Span Switch is active on the West Side.
uniDirectionalFullPassThroughIsActive











.1.3.6.1.4.1.3607.6.10.30.0.3080
Uni-directional Full Pass Through is active.
biDirectionalFullPassThroughIsActive











.1.3.6.1.4.1.3607.6.10.30.0.3090
Bi-directional Full Pass Through is active.
farEndDS3EqptFailNonServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.310
far end DS3 Eqpt failure non service affecting
kBytesPassThroughIsActive











.1.3.6.1.4.1.3607.6.10.30.0.3100
K Bytes Pass Through Is Active
ringIsSegmented











.1.3.6.1.4.1.3607.6.10.30.0.3110
Ring is Segmented.
ringTopologyIsUnderConstruction











.1.3.6.1.4.1.3607.6.10.30.0.3120
Ring Topology is under construction.
lockoutOfProtectionAllSpans











.1.3.6.1.4.1.3607.6.10.30.0.3130
Lockout of Protection - All Spans.
farEndOfFiberIsProvisionedWithDifferentRingID











.1.3.6.1.4.1.3607.6.10.30.0.3140
Far end of fiber is provisioned with different ring ID
bothEndsOfFiberProvisionedAsEastOrBothAsWest











.1.3.6.1.4.1.3607.6.10.30.0.3150
Both ends of fiber provisioned as East, or both as West
securityInvalidLoginUsernameSeeAuditTrail











.1.3.6.1.4.1.3607.6.10.30.0.3160
Security: invalid login (see Audit Trail)
autonomousMessagesInhibited











.1.3.6.1.4.1.3607.6.10.30.0.3170
Autonomous messages inhibited
trafficStormOnLANLANTemporarilyDisabled











.1.3.6.1.4.1.3607.6.10.30.0.3180
Traffic Storm On LAN. LAN Temporarily Disabled
reptdbchgMessagesInhibited











.1.3.6.1.4.1.3607.6.10.30.0.3190
REPT^DBCHG Messages Inhibited
farEndDS3EqptFailServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.320
far end DS3 Eqpt failure service affecting
securityUserIDHasExpired











.1.3.6.1.4.1.3607.6.10.30.0.3200
Security: User ID Has Expired
partialFanFailure











.1.3.6.1.4.1.3607.6.10.30.0.3210
Partial Fan Failure
forcedSwitchRequestOnRing











.1.3.6.1.4.1.3607.6.10.30.0.3220
Forced Switch Request On Ring
forcedSwitchRequestOnSpan











.1.3.6.1.4.1.3607.6.10.30.0.3230
Forced Switch Request On Span
lockoutSwitchRequestOnRing











.1.3.6.1.4.1.3607.6.10.30.0.3240
Lockout switch request on Ring
lockoutSwitchRequestOnSpan











.1.3.6.1.4.1.3607.6.10.30.0.3250
Lockout switch request on Span
manualSwitchRequestOnRing











.1.3.6.1.4.1.3607.6.10.30.0.3260
Manual switch request on Ring
manualSwitchRequestOnSpan











.1.3.6.1.4.1.3607.6.10.30.0.3270
Manual switch request on Span
communicationFailurePeerToPeerSlotControlBusA











.1.3.6.1.4.1.3607.6.10.30.0.3280
Peer to Peer Slot communication failure - Control Bus A
communicationFailurePeerToPeerSlotControlBusB











.1.3.6.1.4.1.3607.6.10.30.0.3290
Peer to Peer Slot communication failure - Control Bus B
farEndCommonEquipmentFailureNonServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.330
far end common Eqpt failure non service affecting
controllerAToShelfSlotCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.3300
Controller A to shelf slot communication failure
controllerBToShelfSlotCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.3310
Controller B to shelf slot communication failure
interconnectionEquipmentFailureWorkingPayloadBus











.1.3.6.1.4.1.3607.6.10.30.0.3320
Interconnection Equipment Failure - Working Payload Bus
interconnectionEquipmentFailureProtectPayloadBus











.1.3.6.1.4.1.3607.6.10.30.0.3330
Interconnection Equipment Failure - Protect Payload Bus
inhibitSwitchToProtectRequestOnEquipment











.1.3.6.1.4.1.3607.6.10.30.0.3340
Inhibit Switch to Protect Request on equipment
inhibitSwitchToWorkingRequestOnEquipment











.1.3.6.1.4.1.3607.6.10.30.0.3350
Inhibit Switch to Working Request on equipment
berThresholdExceededForSignalDegradeLine











.1.3.6.1.4.1.3607.6.10.30.0.3360
BER Threshold exceeded for Signal Degrade - Line
berThresholdExceededForSignalDegradePath











.1.3.6.1.4.1.3607.6.10.30.0.3370
BER Threshold exceeded for Signal Degrade - Path
berThresholdExceededForSignalFailureLine











.1.3.6.1.4.1.3607.6.10.30.0.3380
BER Threshold Exceeded For Signal Failure - Line
berThresholdExceededForSignalFailurePath











.1.3.6.1.4.1.3607.6.10.30.0.3390
BER Threshold Exceeded For Signal Failure - Path
farEndIDLE











.1.3.6.1.4.1.3607.6.10.30.0.340
far end IDLE
exercisingRingSuccessfully











.1.3.6.1.4.1.3607.6.10.30.0.3400
Exercising Ring Successfully
exercisingSpanSuccessfully











.1.3.6.1.4.1.3607.6.10.30.0.3410
Exercising Span Successfully
spanIsInWaitToRestoreState











.1.3.6.1.4.1.3607.6.10.30.0.3420
Span is in Wait To Restore state
exerciseRequestOnRingFailed











.1.3.6.1.4.1.3607.6.10.30.0.3430
Exercise Request on Ring Failed
exerciseRequestOnSpanFailed











.1.3.6.1.4.1.3607.6.10.30.0.3440
Exercise Request on Span Failed
farEndLockoutOfProtectionSpan











.1.3.6.1.4.1.3607.6.10.30.0.3450
Far End Lockout Of Protection - Span
manufacturingDataMemoryEEPROMFailure











.1.3.6.1.4.1.3607.6.10.30.0.3460
Manufacturing Data Memory (EEPROM) Failure
replaceableEquipmentOrUnitIsMissing











.1.3.6.1.4.1.3607.6.10.30.0.3470
Replaceable Equipment/Unit is Missing
softwareDownloadFailed











.1.3.6.1.4.1.3607.6.10.30.0.3480
Software Download Failed
extraTrafficPCADropped











.1.3.6.1.4.1.3607.6.10.30.0.3490
Extra Traffic (PCA) Dropped
farEndLOS











.1.3.6.1.4.1.3607.6.10.30.0.350
far end LOS
etherTxOversubscribed











.1.3.6.1.4.1.3607.6.10.30.0.3500
Ether tx oversubscribed
etherRxOverSubscribed











.1.3.6.1.4.1.3607.6.10.30.0.3510
Ether rx over subscribed
etherTxExcessFlowCtrl











.1.3.6.1.4.1.3607.6.10.30.0.3520
Ether tx excess flow ctrl
etherRxExcessFlowCtrl











.1.3.6.1.4.1.3607.6.10.30.0.3530
Ether rx excess flow ctrl
transportLayerFailure











.1.3.6.1.4.1.3607.6.10.30.0.3540
transport layer failure
etherTxUnderrun











.1.3.6.1.4.1.3607.6.10.30.0.3550
Ether tx underrun
synchronizationReferenceFrequencyOutOfBounds











.1.3.6.1.4.1.3607.6.10.30.0.3560
Synchronization reference frequency out of bounds.
ntpOrSntpHostFailure











.1.3.6.1.4.1.3607.6.10.30.0.3570
NTP/SNTP Host Failure.
peerCardNotResponding











.1.3.6.1.4.1.3607.6.10.30.0.3580
Peer Card Not Responding
alarmsAndEventsSuppressedForThisObject











.1.3.6.1.4.1.3607.6.10.30.0.3590
Alarms and events suppressed for this object
farEndLOF











.1.3.6.1.4.1.3607.6.10.30.0.360
far end LOF
ds3FrameFormatMismatch











.1.3.6.1.4.1.3607.6.10.30.0.3600
DS3 Frame Format Mismatch
waitToRestore











.1.3.6.1.4.1.3607.6.10.30.0.3610
Wait To Restore
extremeHighVoltBatteryA











.1.3.6.1.4.1.3607.6.10.30.0.3620
Extreme High Volt Battery A
extremeLowVoltBatteryA











.1.3.6.1.4.1.3607.6.10.30.0.3630
Extreme Low Volt Battery A
extremeHighVoltBatteryB











.1.3.6.1.4.1.3607.6.10.30.0.3640
Extreme High Volt Battery B
extremeLowVoltBatteryB











.1.3.6.1.4.1.3607.6.10.30.0.3650
Extreme Low Volt Battery B
iosConfigCopyFailed











.1.3.6.1.4.1.3607.6.10.30.0.3660
IOS config copy failed
iosConfigCopyInProgress











.1.3.6.1.4.1.3607.6.10.30.0.3670
IOS config copy in progress
iosConfigCopySuccess











.1.3.6.1.4.1.3607.6.10.30.0.3680
IOS Config Copy Success
farEndBlockError











.1.3.6.1.4.1.3607.6.10.30.0.370
far End Block Error
signalingUnableToSetupCircuit











.1.3.6.1.4.1.3607.6.10.30.0.3710
Signaling Unable to setup circuit
errorInStartupConfig











.1.3.6.1.4.1.3607.6.10.30.0.3712
Error in Startup Config
noStartupConfig











.1.3.6.1.4.1.3607.6.10.30.0.3714
No Startup Config
needToSaveRunningConfig











.1.3.6.1.4.1.3607.6.10.30.0.3716
Need to Save Running Config
invalidAlarm











.1.3.6.1.4.1.3607.6.10.30.0.3718
Invalid Alarm
rsvpHelloFSMToNeighborDown











.1.3.6.1.4.1.3607.6.10.30.0.3720
RSVP Hello FSM to Neighbor down
securityInvalidLoginUsername











.1.3.6.1.4.1.3607.6.10.30.0.3722
Security: Invalid Login - Username - See Audit Log
databaseBackupFailed











.1.3.6.1.4.1.3607.6.10.30.0.3724
Database Backup Failed
databaseRestoreFailed











.1.3.6.1.4.1.3607.6.10.30.0.3726
Database Restore Failed
lmpHelloFSMToControlChannelDown











.1.3.6.1.4.1.3607.6.10.30.0.3730
LMP Hello FSM to Control Channel down
lmpNeighborDiscoveryHasFailed











.1.3.6.1.4.1.3607.6.10.30.0.3740
LMP Neighbor Discovery has failed
unauthorizedIncomingSignalingRequest











.1.3.6.1.4.1.3607.6.10.30.0.3750
Unauthorized incoming signaling request
auditLog80PercentFull











.1.3.6.1.4.1.3607.6.10.30.0.3760
Audit Log 80 Percent Full
moduleCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.3762
Module Communication Failure
auditLog100PercentFullOldestRecordsWillBeLost











.1.3.6.1.4.1.3607.6.10.30.0.3764
Audit Log 100 Percent Full - Oldest records will be lost
standbyDatabaseOutOfSync











.1.3.6.1.4.1.3607.6.10.30.0.3766
Standby Database Out of Sync
redundantPowerCapabilityLost











.1.3.6.1.4.1.3607.6.10.30.0.3768
Redundant Power Capability Lost
forcedSwitchToPrimaryReference











.1.3.6.1.4.1.3607.6.10.30.0.3770
Forced Switch To Primary Reference
forcedSwitchToSecondReference











.1.3.6.1.4.1.3607.6.10.30.0.3780
Forced Switch To Second Reference
forcedSwitchToThirdReference











.1.3.6.1.4.1.3607.6.10.30.0.3790
Forced Switch To Third Reference
ds3IdleCondition











.1.3.6.1.4.1.3607.6.10.30.0.380
idle Condition DS3
forcedSwitchToInternalClock











.1.3.6.1.4.1.3607.6.10.30.0.3800
Forced Switch To Internal Clock
industrialHighTemperature











.1.3.6.1.4.1.3607.6.10.30.0.3805
Industrial High Temperature
lossOfFrame











.1.3.6.1.4.1.3607.6.10.30.0.390
loss of Frame
excessiveSwitching











.1.3.6.1.4.1.3607.6.10.30.0.40
excessive switching
lossOfPointer











.1.3.6.1.4.1.3607.6.10.30.0.400
loss of Pointer
timSectionTraceIdentifierMismatchFailure











.1.3.6.1.4.1.3607.6.10.30.0.4000
TIM Section - Trace Identifier Mismatch Failure.
aisMultiplexSectionAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.4010
AIS - Multiplex Section - Alarm Indication Signal
rdiMultiplexSectionRemoteDefectOrAlarmIndication











.1.3.6.1.4.1.3607.6.10.30.0.4020
RDI - Multiplex Section - Remote Defect/Alarm Indication
timHighOrderTraceIdentifierMismatchFailure











.1.3.6.1.4.1.3607.6.10.30.0.4030
TIM High Order - Trace Identifier Mismatch Failure
aisAdministrationUnitAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.4040
AIS - Administration Unit - Alarm Indication Signal
lopAdministrationUnitLossOfPointer











.1.3.6.1.4.1.3607.6.10.30.0.4050
LOP - Administration Unit - Loss of Pointer
slmfUnequippedHighOrderPathUnequipped











.1.3.6.1.4.1.3607.6.10.30.0.4060
SLMF - Unequipped High Order - Path Unequipped
slmfPLMHighOrderPathLabelMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4070
SLMF - PLM High Order - Path Label Mismatch
rdiHighOrderRemoteDefectOrAlarmIndication











.1.3.6.1.4.1.3607.6.10.30.0.4080
RDI - High Order - Remote Defect/Alarm Indication
lopTributaryUnitLossOfPointer











.1.3.6.1.4.1.3607.6.10.30.0.4090
LOP - Tributary Unit - Loss of Pointer
lossOfPointerPath











.1.3.6.1.4.1.3607.6.10.30.0.410
loss of Pointer Path
aisTributaryUnitAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.4100
AIS - Tributary Unit - Alarm Indication Signal
slmfUnequippedLowOrderPathUnequipped











.1.3.6.1.4.1.3607.6.10.30.0.4110
SLMF - Unequipped Low Order - Path Unequipped
slmfPLMLowOrderPathLabelMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4120
SLMF - PLM Low Order - Path Label Mismatch
timLowOrderTraceIdentifierMismatchFailure











.1.3.6.1.4.1.3607.6.10.30.0.4130
TIM Low Order - Trace Identifier Mismatch Failure
rfiLowOrderRemoteFailureOrAlarmIndication











.1.3.6.1.4.1.3607.6.10.30.0.4140
RFI - Low Order - Remote Failure/Alarm Indication
g811PrimaryReferenceClockTraceable











.1.3.6.1.4.1.3607.6.10.30.0.4150
G811 - Primary Reference Clock traceable.
g812TransitNodeClockTraceable











.1.3.6.1.4.1.3607.6.10.30.0.4160
G812 - Transit Node Clock traceable.
g812LocalNodeClockTraceable











.1.3.6.1.4.1.3607.6.10.30.0.4170
G812 - Local Node Clock traceable.
g813SynchronousEquipmentTimingSourceTraceable











.1.3.6.1.4.1.3607.6.10.30.0.4180
G813 - Synchronous Equipment Timing Source traceable
e1LoopbackDueToFEACCommand











.1.3.6.1.4.1.3607.6.10.30.0.4190
E1 loopback due to FEAC command
lossOfPointerVT











.1.3.6.1.4.1.3607.6.10.30.0.420
loss of Pointer VT
e1LoopbackCommandSentToFarEnd











.1.3.6.1.4.1.3607.6.10.30.0.4200
E1 loopback command sent to Far End
e3LoopbackDueToFEACCommand











.1.3.6.1.4.1.3607.6.10.30.0.4210
E3 loopback due to FEAC command
farEndMultipleE1LOSDetectedOnE3











.1.3.6.1.4.1.3607.6.10.30.0.4220
far end Multiple E1 LOS detected on E3
farEndE1EqptFailNonServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.4230
far end E1 eqpt fail non service affecting
farEndE1EqptFailServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.4240
far end E1 eqpt fail service affecting
farEndSingleE1LOS











.1.3.6.1.4.1.3607.6.10.30.0.4250
far end Single E1 LOS
farEndE3EqptFailServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.4260
far end E3 eqpt fail service affecting
e3LoopbackCommandSentToFarEnd











.1.3.6.1.4.1.3607.6.10.30.0.4270
E3 loopback command sent to far end
farEndE3EqptFailNonServiceAffecting











.1.3.6.1.4.1.3607.6.10.30.0.4280
far end E3 eqpt fail non service affecting
lowVoltBatteryA











.1.3.6.1.4.1.3607.6.10.30.0.4290
Low Volt - Battery A
lossOfSignal











.1.3.6.1.4.1.3607.6.10.30.0.430
loss of Signal
highVoltBatteryA











.1.3.6.1.4.1.3607.6.10.30.0.4300
High Volt - Battery A
lowVoltBatteryB











.1.3.6.1.4.1.3607.6.10.30.0.4310
Low Volt - Battery B
highVoltBatteryB











.1.3.6.1.4.1.3607.6.10.30.0.4320
High Volt - Battery B
msspRingOutOfSync











.1.3.6.1.4.1.3607.6.10.30.0.4330
MS-SP ring out of sync
msspMultiNodeTableUpdateCompleted











.1.3.6.1.4.1.3607.6.10.30.0.4340
MSSP Multi-Node Table Update Completed
automaticSNCPSwitchCausedByAIS











.1.3.6.1.4.1.3607.6.10.30.0.4350
automatic SNCP switch caused by AIS
automaticSNCPSwitchCausedByLOP











.1.3.6.1.4.1.3607.6.10.30.0.4360
automatic SNCP switch caused by Lop
automaticSNCPSwitchCausedByUNEQ











.1.3.6.1.4.1.3607.6.10.30.0.4370
Automatic SNCP Switch caused by UNEQ
automaticSNCPSwitchCausedByPDI











.1.3.6.1.4.1.3607.6.10.30.0.4380
automatic SNCP switch caused by PDI
automaticSNCPSwitchCausedBySFBER











.1.3.6.1.4.1.3607.6.10.30.0.4390
Automatic SNCP Switch caused by SFBER
outOfFrame











.1.3.6.1.4.1.3607.6.10.30.0.440
out of Frame
automaticSNCPSwitchCausedBySDBER











.1.3.6.1.4.1.3607.6.10.30.0.4400
Automatic SNCP Switch caused by SDBER
stmConcatenationError











.1.3.6.1.4.1.3607.6.10.30.0.4410
STM Concatenation error
e3IdleCondition











.1.3.6.1.4.1.3607.6.10.30.0.4420
E3 Idle Condition
channelMSSPInconsistentAPSCode











.1.3.6.1.4.1.3607.6.10.30.0.4430
channel MSSP inconsistent APS code
channelMSSPImproperAPSCodeAPS











.1.3.6.1.4.1.3607.6.10.30.0.4440
channel MSSP Improper APS code APS
channelMSSPNodeIdMismatchAPS











.1.3.6.1.4.1.3607.6.10.30.0.4450
channel MSSP Node Id Mismatch APS
channelMSSPDefaultKAPS











.1.3.6.1.4.1.3607.6.10.30.0.4460
channel MSSP Default K APS
channelMSSPConnectionLossAPS











.1.3.6.1.4.1.3607.6.10.30.0.4470
channel MSSP Connection loss APS
minimumClockTraceableSDH











.1.3.6.1.4.1.3607.6.10.30.0.4480
SDH Minimum clock Traceable
lineIsInWaitToRestoreStateSDH











.1.3.6.1.4.1.3607.6.10.30.0.4490
SDH line is in Wait To Restore state
pathSelectorFailure











.1.3.6.1.4.1.3607.6.10.30.0.450
Path Selector Failure
berThresholdExceededForSignalDegradeHighOrder











.1.3.6.1.4.1.3607.6.10.30.0.4500
BER Threshold Exceeded For Signal Degrade - High Order
berThresholdExceededForSignalFailureHighOrder











.1.3.6.1.4.1.3607.6.10.30.0.4510
BER Threshold Exceeded For Signal Failure - High Order
berThresholdExceededForSignalDegradeLowOrder











.1.3.6.1.4.1.3607.6.10.30.0.4520
BER Threshold Exceeded For Signal Degrade - Low Order
berThresholdExceededForSignalFailureLowOrder











.1.3.6.1.4.1.3607.6.10.30.0.4530
BER Threshold Exceeded For Signal Failure - Low Order
failureToSwitchToProtectionHighOrderPath











.1.3.6.1.4.1.3607.6.10.30.0.4540
Failure To Switch To Protection - High Order Path
failureToSwitchToProtectionLowOrderPath











.1.3.6.1.4.1.3607.6.10.30.0.4550
Failure To Switch To Protection - Low Order Path
lofAdministrationUnitLossOfMultiFrame











.1.3.6.1.4.1.3607.6.10.30.0.4560
LOF - Administration Unit - Loss of Multi Frame
sdhSpanIsInWaitToRestoreState











.1.3.6.1.4.1.3607.6.10.30.0.4570
SDH span is in Wait To Restore state
remoteAlarmIndication











.1.3.6.1.4.1.3607.6.10.30.0.460
remote Alarm Indication
remoteFailureIndication











.1.3.6.1.4.1.3607.6.10.30.0.470
remote Failure Indication
a8b10bOutOfSync











.1.3.6.1.4.1.3607.6.10.30.0.4755
8B10B Out of Sync
odukPMAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.4760
ODUk: PM Alarm Indication Signal
otukAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.4765
OTUk: Alarm Indication Signal
otukSMBackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.4770
OTUk: Backward Defect Indication
odukBackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.4775
ODUk: Backward Defect Indication
fecUncorrectedWord











.1.3.6.1.4.1.3607.6.10.30.0.4780
FEC Uncorrected Word
gccTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.4785
GCC Termination Failure
otukIncomingAlignmentError











.1.3.6.1.4.1.3607.6.10.30.0.4790
OTUk: Incoming Alignment Error
odukLockedDefectPM











.1.3.6.1.4.1.3607.6.10.30.0.4795
ODUk: Locked Defect - PM
remoteFailureIndicationLine











.1.3.6.1.4.1.3607.6.10.30.0.480
remote Failure Indication LINE
lossOfMultiFrame











.1.3.6.1.4.1.3607.6.10.30.0.4800
Loss of Multi-Frame
odukOpenConnectionIndication











.1.3.6.1.4.1.3607.6.10.30.0.4805
ODUk: Open Connection Indication
payloadTypeIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4810
Payload Type Identifier Mismatch
odukTrailTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4815
ODUk: Trail Trace Identifier Mismatch
otukTrailTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4820
OTUk: Trail Trace Identifier Mismatch
equipmentHighLaserBias











.1.3.6.1.4.1.3607.6.10.30.0.4825
Equipment High Laser Bias
equipmentHighLaserTemp











.1.3.6.1.4.1.3607.6.10.30.0.4830
Equipment High Laser Temp
equipmentHighLaserPeltier











.1.3.6.1.4.1.3607.6.10.30.0.4835
Equipment High Laser Peltier
facilityHighRxPower











.1.3.6.1.4.1.3607.6.10.30.0.4840
Facility High Rx power
equipmentHighTxPower











.1.3.6.1.4.1.3607.6.10.30.0.4845
Equipment High Tx power
equipmentHighTransceiverVoltage











.1.3.6.1.4.1.3607.6.10.30.0.4850
Equipment High Transceiver voltage
equipmentLowLaserBias











.1.3.6.1.4.1.3607.6.10.30.0.4855
Equipment Low Laser Bias
equipmentLowLaserTemp











.1.3.6.1.4.1.3607.6.10.30.0.4860
Equipment Low Laser Temp
equipmentLowLaserPeltier











.1.3.6.1.4.1.3607.6.10.30.0.4865
Equipment Low Laser Peltier
facilityLowRxPower











.1.3.6.1.4.1.3607.6.10.30.0.4870
Facility Low Rx power
equipmentLowTxPower











.1.3.6.1.4.1.3607.6.10.30.0.4875
Equipment Low Tx power
equipmentLowTransceiverVoltage











.1.3.6.1.4.1.3607.6.10.30.0.4880
Equipment Low Transceiver voltage
equipmentRxLocked











.1.3.6.1.4.1.3607.6.10.30.0.4885
Equipment Rx Locked
equipmentSquelched











.1.3.6.1.4.1.3607.6.10.30.0.4890
Equipment Squelched
equipmentTxLocked











.1.3.6.1.4.1.3607.6.10.30.0.4895
Equipment Tx Locked
remoteFailureIndicationPath











.1.3.6.1.4.1.3607.6.10.30.0.490
remote Failure Indication Path
otukSignalFailure











.1.3.6.1.4.1.3607.6.10.30.0.4900
OTUK Signal Failure
odukSignalFailure











.1.3.6.1.4.1.3607.6.10.30.0.4905
ODUK Signal Failure
otukSignalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.4910
OTUK Signal Degrade
odukSignalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.4915
ODUK Signal Degrade
pluggablePortMissing











.1.3.6.1.4.1.3607.6.10.30.0.4920
Pluggable Port missing
pluggablePortRateMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4925
Pluggable Port rate mismatch
pluggablePortSecurityCodeMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4930
Pluggable Port security code mismatch
tciNotSelected











.1.3.6.1.4.1.3607.6.10.30.0.4935
Tci not selected
tci1ClockFailure











.1.3.6.1.4.1.3607.6.10.30.0.4940
Tci 1 Clock Failure
odukPMBackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.4945
ODUk: PM Backward Defect Indication
odukTCM1BackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.4950
ODUk: TCM1 Backward Defect Indication
odukTCM2BackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.4955
ODUk: TCM2 Backward Defect Indication
equipmentHighRxTemperature











.1.3.6.1.4.1.3607.6.10.30.0.4960
Equipment High Rx temperature
equipmentLowRxTemperature











.1.3.6.1.4.1.3607.6.10.30.0.4965
Equipment Low Rx temperature
tci2ClockFailure











.1.3.6.1.4.1.3607.6.10.30.0.4970
Tci 2 Clock Failure
equipmentWavelengthMismatch











.1.3.6.1.4.1.3607.6.10.30.0.4975
Equipment Wavelength Mismatch
dspCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.4980
DSP Communication Failure
dspFailure











.1.3.6.1.4.1.3607.6.10.30.0.4985
DSP Failure
sdccTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.50
SDCC Termination failure
remoteFailureIndicationVT











.1.3.6.1.4.1.3607.6.10.30.0.500
remote Failure Indication VT
laserApproachingEndOfLife











.1.3.6.1.4.1.3607.6.10.30.0.5000
Laser Approaching End of Life
crossconnectLoopback











.1.3.6.1.4.1.3607.6.10.30.0.5010
Cross-connect Loopback
adminLogoutOfUser











.1.3.6.1.4.1.3607.6.10.30.0.5020
Admin Logout of User
userLockedOut











.1.3.6.1.4.1.3607.6.10.30.0.5030
User Locked Out
adminLockoutOfUser











.1.3.6.1.4.1.3607.6.10.30.0.5040
Admin Lockout of User
adminLockoutClear











.1.3.6.1.4.1.3607.6.10.30.0.5050
Admin Lockout Clear
invalidLoginUsername











.1.3.6.1.4.1.3607.6.10.30.0.5060
Invalid Login: Username
securityInvalidLoginPassword











.1.3.6.1.4.1.3607.6.10.30.0.5070
Security: Invalid Login - Password - See Audit Log
securityInvalidLoginLockedOut











.1.3.6.1.4.1.3607.6.10.30.0.5080
Security: Invalid Login - Locked Out - See Audit Log
securityInvalidLoginAlreadyLoggedOn











.1.3.6.1.4.1.3607.6.10.30.0.5090
Security: Invalid Login - Already Logged On - See Audit Log
signalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.510
facility has passed BER Threshold for Signal Degrade
loginOfUser











.1.3.6.1.4.1.3607.6.10.30.0.5100
Login of User
automaticLogoutOfIdleUser











.1.3.6.1.4.1.3607.6.10.30.0.5110
Automatic Logout of IdleUser
logoutOfUser











.1.3.6.1.4.1.3607.6.10.30.0.5120
Logout of User
severelyErroredFrame











.1.3.6.1.4.1.3607.6.10.30.0.520
severely Errored Frame
enhancedRemoteFailureIndicationPathServer











.1.3.6.1.4.1.3607.6.10.30.0.5200
Enhanced Remote Failure Indication - Path - Server
enhancedRemoteFailureIndicationPathConnectivity











.1.3.6.1.4.1.3607.6.10.30.0.5210
Enhanced Remote Failure Indication - Path - Connectivity
enhancedRemoteFailureIndicationPathPayload











.1.3.6.1.4.1.3607.6.10.30.0.5220
Enhanced Remote Failure Indication - Path - Payload
firewallHasBeenDisabled











.1.3.6.1.4.1.3607.6.10.30.0.5230
Firewall Has Been Disabled
securityIntrusionDetPwd











.1.3.6.1.4.1.3607.6.10.30.0.5240
Security Intrusion Attempt Detected - See Audit Log
securityIntrusionDetUser











.1.3.6.1.4.1.3607.6.10.30.0.5250
Security Intrusion Attempt Detected - See Audit Log
connectionEquipmentMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5260
Connection Equipment Mismatch
disableInactiveUser











.1.3.6.1.4.1.3607.6.10.30.0.5270
Disable Inactive User
disableInactiveClear











.1.3.6.1.4.1.3607.6.10.30.0.5280
Disable Inactive Clear
batteryFailure











.1.3.6.1.4.1.3607.6.10.30.0.5290
Battery Failure
signalFailure











.1.3.6.1.4.1.3607.6.10.30.0.530
facility has passed BER threshold for Signal Failure
extremeHighVolt











.1.3.6.1.4.1.3607.6.10.30.0.5300
Extreme High Volt
extremeLowVolt











.1.3.6.1.4.1.3607.6.10.30.0.5310
Extreme Low Volt
highVolt











.1.3.6.1.4.1.3607.6.10.30.0.5320
High Volt
lowVolt











.1.3.6.1.4.1.3607.6.10.30.0.5330
Low Volt
suspendUser











.1.3.6.1.4.1.3607.6.10.30.0.5340
Suspend User
suspendUserClear











.1.3.6.1.4.1.3607.6.10.30.0.5350
Suspend User Clear
lineDccTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.5360
Line DCC Termination Failure
multiplexSectionDccTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.5370
Multiplex Section DCC Termination Failure
gigaBitEthernetOutOfSync











.1.3.6.1.4.1.3607.6.10.30.0.5380
GigaBit Ethernet Out of Sync
sequenceMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5390
Sequence Mismatch
signalLabelMismatchFailure











.1.3.6.1.4.1.3607.6.10.30.0.540
signal Label Mismatch Failure
lossOfAlignment











.1.3.6.1.4.1.3607.6.10.30.0.5400
Loss of Alignment
outOfUseByAdministrativeCommand











.1.3.6.1.4.1.3607.6.10.30.0.5410
Out of Use - Administrative Command
outOfUseTransportFailure











.1.3.6.1.4.1.3607.6.10.30.0.5420
Out of Use - Transport Failure
vcatGroupDown











.1.3.6.1.4.1.3607.6.10.30.0.5430
VCAT Group Down
vcatGroupDegraded











.1.3.6.1.4.1.3607.6.10.30.0.5440
VCAT Group Degraded
vcatGroupIncomplete











.1.3.6.1.4.1.3607.6.10.30.0.5450
VCAT Group Incomplete
alarmIndicationSignalInTX











.1.3.6.1.4.1.3607.6.10.30.0.5460
Alarm Indication Signal in TX
remoteAlarmIndicationInTX











.1.3.6.1.4.1.3607.6.10.30.0.5470
Remote Alarm Indication in TX
kByteAPSChannelFailure











.1.3.6.1.4.1.3607.6.10.30.0.5480
Kbyte Channel Failure
apsInvalidMode











.1.3.6.1.4.1.3607.6.10.30.0.5490
APS Invalid Mode
payloadDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.550
Payload Defect Indication
ipAddressAlreadyInUseWithinTheSameDccArea











.1.3.6.1.4.1.3607.6.10.30.0.5500
IP Address A1ready In Use Within The Same DCC Area
nodeNameInUseWithinTheSameDccArea











.1.3.6.1.4.1.3607.6.10.30.0.5510
Node name already in use within the same DCC Area
rearPanelEthernetLinkRemoved











.1.3.6.1.4.1.3607.6.10.30.0.5520
Rear Panel Ethernet Link Removed
manualSwitchToProtectResultedInNoTrafficSwitch











.1.3.6.1.4.1.3607.6.10.30.0.5530
Manual Switch To Protect Resulted in No Traffic Switch
manualSwitchBackToWorkingResultedInNoTrafficSwitch











.1.3.6.1.4.1.3607.6.10.30.0.5540
Manual Switch Back To Working Resulted in No Traffic Switch
forcedSwitchToProtectResultedInNoTrafficSwitch











.1.3.6.1.4.1.3607.6.10.30.0.5550
Forced Switch To Protection Resulted in No Traffic Switch
forcedSwitchBackToWorkingResultedInNoTrafficSwitch











.1.3.6.1.4.1.3607.6.10.30.0.5560
Forced Switch Back To Working Resulted in No Traffic Switch
duplicateSerialNumberDetectedOnAPluggableEntity











.1.3.6.1.4.1.3607.6.10.30.0.5570
Duplicate Serial number detected on a pluggable entity
payloadDefectIndicationPath











.1.3.6.1.4.1.3607.6.10.30.0.560
Payload Defect Indication - Path
lossOfSignalForOpticalChannel











.1.3.6.1.4.1.3607.6.10.30.0.5600
Incoming Payload Signal Absent
encapsulationMismatchPath











.1.3.6.1.4.1.3607.6.10.30.0.5610
Encapsulation Mismatch Path
encapsulationMismatchVT











.1.3.6.1.4.1.3607.6.10.30.0.5620
Encapsulation Mismatch - VT
encapsulationMismatchHighOrderPath











.1.3.6.1.4.1.3607.6.10.30.0.5630
Encapsulation Mismatch High Order - Path
encapsulationMismatchLowOrderPath











.1.3.6.1.4.1.3607.6.10.30.0.5640
Encapsulation Mismatch Low Order - Path
gfpUserPayloadMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5650
GFP User Payload Mismatch
gfpFibreChannelDistanceExtensionMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5660
GFP Fibre Channel Distance Extension Mismatch
gfpFibreChannelDistanceExtensionBufferStarvation











.1.3.6.1.4.1.3607.6.10.30.0.5670
GFP Fibre Channel Distance Extension Buffer Starvation
gfpFibreChannelDistanceExtensionCreditStarvation











.1.3.6.1.4.1.3607.6.10.30.0.5680
Fibre Channel Distance Extension Credit Starvation
automaticWdmAnsFinished











.1.3.6.1.4.1.3607.6.10.30.0.5690
Automatic WDM ANS Finished
payloadLabelMismatchPath











.1.3.6.1.4.1.3607.6.10.30.0.570
Payload Label Mismatch - Path
gfpClientSignalFailDetected











.1.3.6.1.4.1.3607.6.10.30.0.5700
GFP Client Signal Fail Detected
gfpLossOfFrameDelineation











.1.3.6.1.4.1.3607.6.10.30.0.5710
GFP Loss of Frame Delineation
gfpExtensionHeaderMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5730
GFP Extension Header Mismatch
incomingOverheadSignalAbsent











.1.3.6.1.4.1.3607.6.10.30.0.5740
Incoming Overhead Signal Absent
opticalSafetyRemoteInterlockOn











.1.3.6.1.4.1.3607.6.10.30.0.5750
Optical Safety Remote Interlock On
automaticPowerControlCorrectionSkipped











.1.3.6.1.4.1.3607.6.10.30.0.5770
Automatic Power Control Correction Skipped
apcCannotSetValueDueToRangeLimits











.1.3.6.1.4.1.3607.6.10.30.0.5780
APC cannot set value due to range limits
lcasVcgMemberTxSideInAddState











.1.3.6.1.4.1.3607.6.10.30.0.5790
LCAS VCG Member Tx Side In ADD State
signalLabelMismatchFailurePayloadLabelMismatchVT











.1.3.6.1.4.1.3607.6.10.30.0.580
signal Label Mismatch Failure Payload Label Mismatch VT
farEndManualSwitchBackToWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.5800
Far End Manual Switch Back to Working - Span
farEndForcedSwitchBackToWorkingSpan











.1.3.6.1.4.1.3607.6.10.30.0.5810
Far End Forced Switch Back to Working - Span
universalTransponderModuleHardwareFailure











.1.3.6.1.4.1.3607.6.10.30.0.5820
Universal Transponder Module Hardware Failure
universalTransponderModuleCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.5830
Universal Transponder Module Communication Failure
pluginModuleRangeSettingsMismatch











.1.3.6.1.4.1.3607.6.10.30.0.5840
Plug-in Module Range Settings Mismatch
lcasVcgMemberTxSideInDnuState











.1.3.6.1.4.1.3607.6.10.30.0.5850
LCAS VCG Member Tx Side In DNU State
lcasControlWordCrcCheckFailure











.1.3.6.1.4.1.3607.6.10.30.0.5860
LCAS Control Word CRC Check Failure
lcasVcgMemberRxSideInFailState











.1.3.6.1.4.1.3607.6.10.30.0.5870
LCAS VCG Member Rx Side In FAIL State
signalLossOnDataInterface











.1.3.6.1.4.1.3607.6.10.30.0.5880
Signal Loss on Data Interface
synchronizationLossOnDataInterface











.1.3.6.1.4.1.3607.6.10.30.0.5890
Synchronization Loss on Data Interface
unequippedPath











.1.3.6.1.4.1.3607.6.10.30.0.590
Unequipped - Path
portFAIL











.1.3.6.1.4.1.3607.6.10.30.0.5900
PORT FAIL
unreachablePortTargetPower











.1.3.6.1.4.1.3607.6.10.30.0.5910
Unreachable port target power
portAddPowerDegradeLow











.1.3.6.1.4.1.3607.6.10.30.0.5920
Port Add Power Degrade Low
portAddPowerDegradeHigh











.1.3.6.1.4.1.3607.6.10.30.0.5930
Port Add Power Degrade High
portAddPowerFailLow











.1.3.6.1.4.1.3607.6.10.30.0.5940
Port Add Power Fail Low
portAddPowerFailHigh











.1.3.6.1.4.1.3607.6.10.30.0.5950
Port Add Power Fail High
incomingFailureCondition











.1.3.6.1.4.1.3607.6.10.30.0.60
incoming failure condition
signalLabelMismatchFailureUnequippedVT











.1.3.6.1.4.1.3607.6.10.30.0.600
signal Label Mismatch Failure Unequipped VT
automaticPowerControlTerminatedOnManualRequest











.1.3.6.1.4.1.3607.6.10.30.0.6000
Automatic Power Control Terminated on Manual request
oduk1AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.6010
ODUk-1: Alarm Indication Signal
oduk2AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.6020
ODUk-2: Alarm Indication Signal
oduk3AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.6030
ODUk-3: Alarm Indication Signal
oduk4AlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.6040
ODUk-4: Alarm Indication Signal
temperatureReadingMismatchBetweenSCCards











.1.3.6.1.4.1.3607.6.10.30.0.6050
Temperature Reading Mismatch Between SC Cards
voltageReadingMismatchBetweenSCCards











.1.3.6.1.4.1.3607.6.10.30.0.6060
Voltage Reading Mismatch Between SC Cards
alarmsSuppressedonOutOfGroupVcatMember











.1.3.6.1.4.1.3607.6.10.30.0.6070
Alarms Suppressed on Out-Of-Group VCAT Member
blsrSoftwareVersionMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6080
BLSR Software Version Mismatch
optimized1Plus1ApsPrimaryFacility











.1.3.6.1.4.1.3607.6.10.30.0.6090
Optimized 1+1 APS Primary Facility
lossOfSynchronization











.1.3.6.1.4.1.3607.6.10.30.0.610
Loss of Synchronization
optimized1Plus1ApsPrimarySectionMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6100
Optimized 1+1 APS Primary Section Mismatch
optimized1Plus1ApsInvalidPrimarySection











.1.3.6.1.4.1.3607.6.10.30.0.6110
Optimized 1+1 APS Invalid Primary Section
compositeClockHighLineVoltage











.1.3.6.1.4.1.3607.6.10.30.0.6120
Composite Clock High Line Voltage
berThresholdExceededForSignalDegradeVt











.1.3.6.1.4.1.3607.6.10.30.0.6130
BER Threshold Exceeded For Signal Degrade - VT
berThresholdExceededForSignalFailureVt











.1.3.6.1.4.1.3607.6.10.30.0.6140
BER Threshold Exceeded For Signal Failure - VT
spanLengthOutOfRange











.1.3.6.1.4.1.3607.6.10.30.0.6150
Span Length Out of Range
idleSignalCondition











.1.3.6.1.4.1.3607.6.10.30.0.6170
Idle Signal Condition
idleSignalConditionInTx











.1.3.6.1.4.1.3607.6.10.30.0.6180
Idle Signal Condition in TX
vtPathTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6190
VT Path Trace Identifier Mismatch
outOfSynchronization











.1.3.6.1.4.1.3607.6.10.30.0.620
Out of Synchronization
lossOfFrameInTX











.1.3.6.1.4.1.3607.6.10.30.0.6200
Loss of Frame in TX
provisioningMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6210
Provisioning Mismatch
sectionTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6220
Section Trace Identifier Mismatch
regeneratorSectionTraceIdentifierMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6230
Regenerator Section Trace Identifier Mismatch
switchingMatrixModuleFailureWorking











.1.3.6.1.4.1.3607.6.10.30.0.6240
Switching Matrix Module Failure - Working
switchingMatrixModuleFailureProtect











.1.3.6.1.4.1.3607.6.10.30.0.6250
Switching Matrix Module Failure - Protect
slotCommunicationDisabled











.1.3.6.1.4.1.3607.6.10.30.0.6260
Slot Communication Disabled
sessionTimeLimitExpired











.1.3.6.1.4.1.3607.6.10.30.0.6270
Session Time Limit Expired
userPasswordChangeRequired











.1.3.6.1.4.1.3607.6.10.30.0.6280
User Password Change Required
isisAdjacencyFailure











.1.3.6.1.4.1.3607.6.10.30.0.6290
ISIS Adjacency Failure
primarySynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.630
Primary Synchronization Reference Failure
msspSoftwareVersionMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6300
MSSP Software Version Mismatch
remoteAuthenticationFailSeeAuditLog











.1.3.6.1.4.1.3607.6.10.30.0.6310
Remote Authentication Fail - See Audit Log
ringIsSquelchingStsTraffic











.1.3.6.1.4.1.3607.6.10.30.0.6330
Ring Is Squelching STS Traffic
ringIsSquelchingVtTraffic











.1.3.6.1.4.1.3607.6.10.30.0.6340
Ring Is Squelching VT Traffic
archiveOfAuditLogFailed











.1.3.6.1.4.1.3607.6.10.30.0.6350
Archival of Audit Log Failed
rprWrapped











.1.3.6.1.4.1.3607.6.10.30.0.6360
RPR Wrapped
shelfCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.6370
Shelf Communication Failure
duplicatedShelfIdentifier











.1.3.6.1.4.1.3607.6.10.30.0.6380
Duplicated Shelf Identifier
softwareMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6390
Software Mismatch
secondarySynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.640
Secondary Synchronization Reference Failure
lmpFailure











.1.3.6.1.4.1.3607.6.10.30.0.6400
LMP Failure
opticalTerminationIncomplete











.1.3.6.1.4.1.3607.6.10.30.0.6410
Optical Termination Incomplete
forwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.6420
Forward Defect Indication
payloadMissingIndication











.1.3.6.1.4.1.3607.6.10.30.0.6430
Payload Missing Indication
spanMeasurementCannotBePerformed











.1.3.6.1.4.1.3607.6.10.30.0.6440
Span loss not checked
ringIsSquelchingHighOrderTraffic











.1.3.6.1.4.1.3607.6.10.30.0.6450
Ring Is Squelching High Order Traffic
ringIsSquelchingLowOrderTraffic











.1.3.6.1.4.1.3607.6.10.30.0.6460
Ring Is Squelching Low Order Traffic
badPacketCountExceedsThreshold











.1.3.6.1.4.1.3607.6.10.30.0.6470
Bad Packet Count Exceeds Threshold
linkLayerKeepAliveFailure











.1.3.6.1.4.1.3607.6.10.30.0.6480
Link Layer Keep-Alive Failure
autonegotiationRemoteFailureIndication











.1.3.6.1.4.1.3607.6.10.30.0.6490
Auto-Negotiation Remote Failure Indication
thirdSynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.650
Third Synchronization Reference Failure
trailSignalFail











.1.3.6.1.4.1.3607.6.10.30.0.6500
Trail Signal Fail
ds1LoopbackCommandSentToFarEnd











.1.3.6.1.4.1.3607.6.10.30.0.6510
DS1 Loopback Command Sent To Far End
multiplexSectionSignalDegraded











.1.3.6.1.4.1.3607.6.10.30.0.6520
Multiplex Section - Signal Degraded
multiplexSectionExcessiveErrors











.1.3.6.1.4.1.3607.6.10.30.0.6530
Multiplex Section - Excessive Errors
highOrderPathSignalDegraded











.1.3.6.1.4.1.3607.6.10.30.0.6540
High Order Path - Signal Degraded
highOrderPathExcessiveErrors











.1.3.6.1.4.1.3607.6.10.30.0.6550
High Order Path - Excessive Errors
lowOrderPathSignalDegraded











.1.3.6.1.4.1.3607.6.10.30.0.6560
Low Order Path - Signal Degraded
lowOrderPathExcessiveErrors











.1.3.6.1.4.1.3607.6.10.30.0.6570
Low Order Path - Excessive Errors
regeneratorSectionDccTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.6580
Regenerator Section - DCC Termination Failure
networkMemoryPoolLow











.1.3.6.1.4.1.3607.6.10.30.0.6590
Network Memory Pool Low
fourthSynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.660
Fourth Synchronization Reference Failure
ospfRoutingTableOverflow











.1.3.6.1.4.1.3607.6.10.30.0.6600
OSPF Routing Table Overflow
autoLaserShutdownDisabled











.1.3.6.1.4.1.3607.6.10.30.0.6610
Auto Laser Shutdown Disabled
rprProtectionIsActive











.1.3.6.1.4.1.3607.6.10.30.0.6630
RPR Protection Is Active
maxRPRStationNumberExceeded











.1.3.6.1.4.1.3607.6.10.30.0.6640
Max RPR Station Number Exceeded
rprProtectionConfigurationMismatched











.1.3.6.1.4.1.3607.6.10.30.0.6650
RPR Protection Configuration Mismatched
reservedBandwidthLinkRateExceededOnRinglet0











.1.3.6.1.4.1.3607.6.10.30.0.6660
Reserved Bandwidth Link Rate Exceeded On Ringlet0
reservedBandwidthLinkRateExceededOnRinglet1











.1.3.6.1.4.1.3607.6.10.30.0.6670
Reserved Bandwidth Link Rate Exceeded On Ringlet1
rprInterfaceInPassThroughMode











.1.3.6.1.4.1.3607.6.10.30.0.6680
RPR Interface In Pass Through Mode
rprPeerNodeIsMissing











.1.3.6.1.4.1.3607.6.10.30.0.6690
RPR Peer Node is Missing
fifthSynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.670
Fifth Synchronization Reference Failure
rprRiFailure











.1.3.6.1.4.1.3607.6.10.30.0.6700
RPR RI Failure
rprSignalFailure











.1.3.6.1.4.1.3607.6.10.30.0.6710
RPR Signal Failure
rprSignalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.6720
RPR Signal Degrade
interlinkFailure











.1.3.6.1.4.1.3607.6.10.30.0.6730
ADM Peer Cards Interlink Failure
apcWrongGain











.1.3.6.1.4.1.3607.6.10.30.0.6740
APC Wrong Gain Set Point
rprSpanMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6750
RPR Span Mismatch
efmRemoteFaultIndicationCriticalEvent











.1.3.6.1.4.1.3607.6.10.30.0.6760
EFM Remote Fault Inidication- Critical Event
efmRemoteFaultIndicationDyingGasp











.1.3.6.1.4.1.3607.6.10.30.0.6770
EFM Remote Fault Inidication- Dying Gasp
efmRemoteFaultIndicationLinkFault











.1.3.6.1.4.1.3607.6.10.30.0.6780
EFM Remote Fault Inidication- Link Fault
efmLinkMonitoringErroredSymbolPeriodEvent











.1.3.6.1.4.1.3607.6.10.30.0.6790
EFM Link Monitoring- Errored Symbol Period Event
sixthSynchronizationReferenceFailure











.1.3.6.1.4.1.3607.6.10.30.0.680
Sixth Synchronization Reference Failure
efmLinkMonitoringErroredFrameEvent











.1.3.6.1.4.1.3607.6.10.30.0.6800
EFM Link Monitoring- Errored Frame Event
efmLinkMonitoringErroredFramePeriodEvent











.1.3.6.1.4.1.3607.6.10.30.0.6810
EFM Link Monitoring- Errored Frame Period Event
efmLinkMonitoringErroredFrameSecondsSummary











.1.3.6.1.4.1.3607.6.10.30.0.6820
EFM Link Monitoring- Errored Frame Seconds Summary
efmRemoteLoopbackRequestFailed











.1.3.6.1.4.1.3607.6.10.30.0.6830
EFM Remote Loopback Request Failed
fastAutomaticProtectionSwitching











.1.3.6.1.4.1.3607.6.10.30.0.6840
Fast Automatic Protection Switching
fastAutomaticProtectionSwitchingConfigMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6850
Fast Automatic Protection Switching Config Mismatch
lcasSinkGroupError











.1.3.6.1.4.1.3607.6.10.30.0.6860
LCAS Sink Group Error
lcasVcgMemberRxSideInDnuState











.1.3.6.1.4.1.3607.6.10.30.0.6870
LCAS VCG Member Rx Side In DNU State
fcDistanceExtFuncNotEstablished











.1.3.6.1.4.1.3607.6.10.30.0.6880
Fibre Channel Distance Extension Function Not Established
nonCiscoPPMInserted











.1.3.6.1.4.1.3607.6.10.30.0.6890
Non Cisco PPM Inserted
failedToReceiveSynchronizationStatusMessage











.1.3.6.1.4.1.3607.6.10.30.0.690
failed to receive Synchronization Status Message
unqualifiedPPMInserted











.1.3.6.1.4.1.3607.6.10.30.0.6900
Unqualified PPM Inserted
ftaMismatch











.1.3.6.1.4.1.3607.6.10.30.0.6910
FanTray Mismatch
cardPortsUnableToProvideProtection











.1.3.6.1.4.1.3607.6.10.30.0.6920
Card/Ports Unable To Provide Protection
lmpSignalDegrade











.1.3.6.1.4.1.3607.6.10.30.0.6930
LMP Signal Degrade
lmpSignalFailure











.1.3.6.1.4.1.3607.6.10.30.0.6940
LMP Signal Failure
lmpUnallocatedDataLink











.1.3.6.1.4.1.3607.6.10.30.0.6950
LMP Unallocated Data Link
frontPortLinkLoss











.1.3.6.1.4.1.3607.6.10.30.0.6960
TCC Front Port Link Loss
bertEnbl











.1.3.6.1.4.1.3607.6.10.30.0.6970
BERT Enabled
bertSyncFail











.1.3.6.1.4.1.3607.6.10.30.0.6975
BERT Synchronization Status Failed
workQueueFull











.1.3.6.1.4.1.3607.6.10.30.0.6980
Work Queue Full
alarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.70
alarm indication signal
synchronizationStatusMessagesAreDisabledOnThisInterface











.1.3.6.1.4.1.3607.6.10.30.0.700
synchronization Status Messages are disabled on this
interface
equipmentPowerFailureAtConnectorA











.1.3.6.1.4.1.3607.6.10.30.0.7000
Equipment power failure at connector A
equipmentPowerFailureAtConnectorB











.1.3.6.1.4.1.3607.6.10.30.0.7005
Equipment power failure at connector B
equipmentPowerFailureAtReturnConnectorA











.1.3.6.1.4.1.3607.6.10.30.0.7010
Equipment power failure at return connector A
equipmentPowerFailureAtReturnConnectorB











.1.3.6.1.4.1.3607.6.10.30.0.7015
Equipment power failure at return connector B
bridgeAndRollHasOccurred











.1.3.6.1.4.1.3607.6.10.30.0.7055
Bridge and Roll Has Occurred
bridgeAndRollIsPendingAValidSignal











.1.3.6.1.4.1.3607.6.10.30.0.7060
Bridge and Roll is Pending a Valid Signal
stratum1PrimaryReferenceSourceTraceable











.1.3.6.1.4.1.3607.6.10.30.0.710
Stratum1 Primary Reference Source Traceable
clockBusFailureTscA











.1.3.6.1.4.1.3607.6.10.30.0.7160
Clock Bus Failure - Shelf Controller A
clockBusFailureTscB











.1.3.6.1.4.1.3607.6.10.30.0.7165
Clock Bus Failure - Shelf Controller B
ospfHelloFail











.1.3.6.1.4.1.3607.6.10.30.0.7185
OSPF Hello Fail
synchronizedTraceabilityUnknown











.1.3.6.1.4.1.3607.6.10.30.0.720
synchronized Traceability Unknown
openIOSlots











.1.3.6.1.4.1.3607.6.10.30.0.7200
Open IO Slots
lossOfClockFromMateShelfController











.1.3.6.1.4.1.3607.6.10.30.0.7210
Loss of Clock from Mate Shelf Controller
virtualLanAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.7225
Virtual Lan AIS
dcuLossFailure











.1.3.6.1.4.1.3607.6.10.30.0.7230
DCU Loss Failure
ochncMaintenance











.1.3.6.1.4.1.3607.6.10.30.0.7235
OCHNC Maintenance
ramanLaserShutdown











.1.3.6.1.4.1.3607.6.10.30.0.7240
Raman Laser Shutdown
losOfRamanSignal











.1.3.6.1.4.1.3607.6.10.30.0.7245
Loss Of Raman Signal
mcastMacTableFull











.1.3.6.1.4.1.3607.6.10.30.0.7250
Multicast Mac Address Table Full
multicastMacAddressAliasing











.1.3.6.1.4.1.3607.6.10.30.0.7255
Multicast Mac Address Aliasing
ramanPwrProtOn











.1.3.6.1.4.1.3607.6.10.30.0.7260
Raman Power Protection On
cppPeerNotResponding











.1.3.6.1.4.1.3607.6.10.30.0.7265
CPP Peer Not Responding
voaControlLoopDisableDueToExcessiveCounterPropagationLight











.1.3.6.1.4.1.3607.6.10.30.0.7275
VOA Control Loop Disable Due To Excessive Counter-Propagation Light
wizardIsRunning











.1.3.6.1.4.1.3607.6.10.30.0.7280
Wizard Is Running
ramanGainNotReached











.1.3.6.1.4.1.3607.6.10.30.0.7285
Raman Span Not Tuned
pprForwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.7295
pprForwardDefectIndication
stratum2Traceable











.1.3.6.1.4.1.3607.6.10.30.0.730
stratum 2 Traceable
pprBackwardDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.7300
pprBackwardDefectIndication
pprCoordinatedMaintenance











.1.3.6.1.4.1.3607.6.10.30.0.7305
pprCoordinatedMaintenance
pprTriggerThresholdBERExceeded











.1.3.6.1.4.1.3607.6.10.30.0.7310
pprTriggerThresholdBERExceeded
localFault











.1.3.6.1.4.1.3607.6.10.30.0.7315
Local Fault
remoteFault











.1.3.6.1.4.1.3607.6.10.30.0.7320
Remote Fault
efmRemoteLoopbackConfigured











.1.3.6.1.4.1.3607.6.10.30.0.7325
EFM Port In Remote Loopback
efmPeerMissing











.1.3.6.1.4.1.3607.6.10.30.0.7330
EFM Link To Peer Missing
eqptDegrade











.1.3.6.1.4.1.3607.6.10.30.0.7335
Equipment Degrade
excessiveBackPropagation











.1.3.6.1.4.1.3607.6.10.30.0.7340
Excessive Back Propagation
remoteMaintenanceEndPointIsDown











.1.3.6.1.4.1.3607.6.10.30.0.7345
CFM Remote Maintenance End Point Is Down
crossConnectedCFMService











.1.3.6.1.4.1.3607.6.10.30.0.7350
Cross Connected CFM Service
cfmLoop











.1.3.6.1.4.1.3607.6.10.30.0.7355
CFM Loop
cfmConfigurationError











.1.3.6.1.4.1.3607.6.10.30.0.7360
CFM Configuration Error
outOfChannelGroupBundle











.1.3.6.1.4.1.3607.6.10.30.0.7365
Out Of Channel Group Bundle
repNeighborAdjacencyFailure











.1.3.6.1.4.1.3607.6.10.30.0.7370
REP Neighbor Adjacency Failure
repLinkFlapping











.1.3.6.1.4.1.3607.6.10.30.0.7375
REP Link Flapping
faultInREPSegment











.1.3.6.1.4.1.3607.6.10.30.0.7380
Fault In REP Segment
primaryREPEdgePortElected











.1.3.6.1.4.1.3607.6.10.30.0.7385
Primary REP Edge Port Elected
secondaryREPEdgePortElected











.1.3.6.1.4.1.3607.6.10.30.0.7390
Secondary REP Edge Port Elected
stcnREPGenerated











.1.3.6.1.4.1.3607.6.10.30.0.7395
STCN REP Generated
transitNodeClockTraceable











.1.3.6.1.4.1.3607.6.10.30.0.740
transit Node clock Traceable
vlbREPActivated











.1.3.6.1.4.1.3607.6.10.30.0.7400
VLB REP Activated
vlbREPTriggerSoakingDelayActive











.1.3.6.1.4.1.3607.6.10.30.0.7405
VLB REP Trigger Soaking Delay Active
wanSyncloss











.1.3.6.1.4.1.3607.6.10.30.0.7410
Ethernet Syncloss On WAN Port
laserShutdownDueToWavelengthDrift











.1.3.6.1.4.1.3607.6.10.30.0.7415
laser Shutdown Due To Wavelength Drift
manualLaserRestart











.1.3.6.1.4.1.3607.6.10.30.0.7420
manual Laser Restart
laserShutdownDueToNonCiscoPPMInserted











.1.3.6.1.4.1.3607.6.10.30.0.7425
laserShutdownDueToNonCiscoPPMInserted
ethernetOSCTerminationFailure











.1.3.6.1.4.1.3607.6.10.30.0.7430
Ethernet OSC Termination Failure
softwareSignatureVerificationFailed











.1.3.6.1.4.1.3607.6.10.30.0.7445
software Signature Verification Failed
protectVolumeSoftwareSignatureVerificationFailed











.1.3.6.1.4.1.3607.6.10.30.0.7450
Protect Volume Software Signature Verification
activeVolumeSoftwareSignatureVerificationFailed











.1.3.6.1.4.1.3607.6.10.30.0.7455
Active Software Signature Verification Failed
peerPortClientSignalFailDetected











.1.3.6.1.4.1.3607.6.10.30.0.7460
Peer Port Client Signal Fail Detected
channelShutdownDueToWavelengthDrift











.1.3.6.1.4.1.3607.6.10.30.0.7465
Channel Shutdown Due to Wavelength Drift
usbWriteFailure











.1.3.6.1.4.1.3607.6.10.30.0.7475
USB Write Failure
usbSyncInProgress











.1.3.6.1.4.1.3607.6.10.30.0.7480
USB Sync in Progress
autoSensingUnableToDetectValidPayload











.1.3.6.1.4.1.3607.6.10.30.0.7485
Auto-Sensing Unable To Detect Valid Payload
payloadAutoSensingInProgress











.1.3.6.1.4.1.3607.6.10.30.0.7490
Payload Auto-Sensing In Progress
gfpClientSignalFailDetectedDueToSigloss











.1.3.6.1.4.1.3607.6.10.30.0.7495
GFP Client Signal Fail Detected Due To Sigloss
stratum3ETraceable











.1.3.6.1.4.1.3607.6.10.30.0.750
stratum 3E Traceable
gfpClientSignalFailDetectedDueToSyncloss











.1.3.6.1.4.1.3607.6.10.30.0.7500
GFP Client Signal Fail Detected Due To Syncloss
pmdDegrade











.1.3.6.1.4.1.3607.6.10.30.0.7510
PMD Degrade
standbyTccNEClockIsInternalClock











.1.3.6.1.4.1.3607.6.10.30.0.7515
Standby Tcc NE Clock Is Internal Clock
chromaticDispersionValue











.1.3.6.1.4.1.3607.6.10.30.0.7520
chromatic Dispersion Value
packetTransportServiceFailed











.1.3.6.1.4.1.3607.6.10.30.0.7525
Packet Transport Service Failed
satellitePanelDiscoveryFailure











.1.3.6.1.4.1.3607.6.10.30.0.7530
Satellite Panel Discovery Failure
satellitePanelActiveLinkFailure











.1.3.6.1.4.1.3607.6.10.30.0.7535
Satellite Panel Active Link Failure
satellitePanelCommunicationFailure











.1.3.6.1.4.1.3607.6.10.30.0.7540
Satellite Panel Communication Failure
satellitePanelImproperConfiguration











.1.3.6.1.4.1.3607.6.10.30.0.7545
Satellite Panel Improper Configuration
satellitePanelFanMismatchOfEquipmentAndAttributes











.1.3.6.1.4.1.3607.6.10.30.0.7550
Satellite Panel Fan Mismatch Of Equipment And Attributes
satellitePanelFanFailure











.1.3.6.1.4.1.3607.6.10.30.0.7555
Satellite Panel Fan Failure
satellitePanelPartialFanFailure











.1.3.6.1.4.1.3607.6.10.30.0.7560
Satellite Panel Partial Fan Failure
satellitePanelFANManufacturingDataMemoryEEPROMFailure











.1.3.6.1.4.1.3607.6.10.30.0.7565
Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure
satellitePanelFANUnitIsMissing











.1.3.6.1.4.1.3607.6.10.30.0.7570
Satellite Panel FAN Unit Is Missing
satellitePanelIndustrialHighTemperature











.1.3.6.1.4.1.3607.6.10.30.0.7575
Satellite Panel Industrial High Temperature
satellitePanelHighTemperature











.1.3.6.1.4.1.3607.6.10.30.0.7580
Satellite Panel High Temperature
satellitePanelBatteryFailureA











.1.3.6.1.4.1.3607.6.10.30.0.7585
Satellite Panel Battery Failure A
plannedSwitchOver











.1.3.6.1.4.1.3607.6.10.30.0.7590
Planned Switch Over
protectionCardConfigurationMismatch











.1.3.6.1.4.1.3607.6.10.30.0.7595
protection CardConfiguration Mismatch
stratum3Traceable











.1.3.6.1.4.1.3607.6.10.30.0.760
stratum 3 Traceable
routerProcessorSwitchOver











.1.3.6.1.4.1.3607.6.10.30.0.7600
Router Processor Switch Over
runningLowOnResources











.1.3.6.1.4.1.3607.6.10.30.0.7605
Running Low On Resources
noMoreResourcesAreAvailable











.1.3.6.1.4.1.3607.6.10.30.0.7610
No More Resources Are Available
esmcFailure











.1.3.6.1.4.1.3607.6.10.30.0.7615
ESMC Failure
licenseWillExpireWithin24Hours











.1.3.6.1.4.1.3607.6.10.30.0.7620
License Will Expire Within 24 Hours
licenseWillExpireAnytimeAfter1DayButBefore14Days











.1.3.6.1.4.1.3607.6.10.30.0.7625
license Will Expire Anytime After 1Day But Before 14Days
licenseIsExpired











.1.3.6.1.4.1.3607.6.10.30.0.7630
license Is Expired
licenseCountViolation











.1.3.6.1.4.1.3607.6.10.30.0.7635
license Count Violation
temporaryLicenseIsInUse











.1.3.6.1.4.1.3607.6.10.30.0.7640
Temporary License Is In Use
evaluationLicenseIsInUse











.1.3.6.1.4.1.3607.6.10.30.0.7645
Evaluation License Is In Use
licenseIsMissing











.1.3.6.1.4.1.3607.6.10.30.0.7650
License Is Missing
pseudowireDown











.1.3.6.1.4.1.3607.6.10.30.0.7655
Pseudowire Down
workingPseudowireControlPlaneDown











.1.3.6.1.4.1.3607.6.10.30.0.7660
Working Pseudowire Control Plane Down
protectPseudowireControlPlaneDown











.1.3.6.1.4.1.3607.6.10.30.0.7665
Protect Pseudowire Control Plane Down
workingPseudowireConnectivityCheckDown











.1.3.6.1.4.1.3607.6.10.30.0.7670
Working Pseudowire Connectivity Check Down
protectPseudowireConnectivityCheckDown











.1.3.6.1.4.1.3607.6.10.30.0.7675
Protect Pseudowire Connectivity Check Down
pseudowireTrafficSwitchedToProtection











.1.3.6.1.4.1.3607.6.10.30.0.7680
Pseudowire Traffic Switched To Pretection
workingPseudowireLocalAcTxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7685
Working Pseudowire Local AcTx Port Fault
protectPseudowireLocalAcTxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7690
Protect Pseudowire Local AcTx Port Fault
workingPseudowireLocalAcRxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7695
Working Pseudowire Local AcRx Port Fault
sonetMinimumClockTraceable











.1.3.6.1.4.1.3607.6.10.30.0.770
SONET Minimum Clock Traceable
protectPseudowireLocalAcRxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7700
Protect Pseudowire Local AcRx Port Fault
workingPseudowireRemoteAcTxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7705
Working Pseudowire Remote AcTx Port Fault
protectPseudowireRemoteAcTxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7710
Protect Pseudowire Remote AcTx Port Fault
workingPseudowireRemoteAcRxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7715
working Pseudowire Remote AcRx Port Fault
protectPseudowireRemoteAcRxPortFault











.1.3.6.1.4.1.3607.6.10.30.0.7720
Protect Pseudowire Remote AcRx Port Fault
slaThresholdCrossAlert











.1.3.6.1.4.1.3607.6.10.30.0.7725
SLA Threshold Cross Alert
protectLocalPseudowireNotForwarding











.1.3.6.1.4.1.3607.6.10.30.0.7730
Protect Local Pseudowire Not Forwarding
workingPseudowireNotForwarding











.1.3.6.1.4.1.3607.6.10.30.0.7735
Working Remote Pseudowire Not Forwarding
protectPseudowireNotForwarding











.1.3.6.1.4.1.3607.6.10.30.0.7740
Protect Remote Pseudowire Not Forwarding
tpTunnelDown











.1.3.6.1.4.1.3607.6.10.30.0.7745
Tp Tunnel Down
workingLabelSwitchedPathDown











.1.3.6.1.4.1.3607.6.10.30.0.7750
Working Label Switched Path Down
protectLabelSwitchedPathDown











.1.3.6.1.4.1.3607.6.10.30.0.7755
Protect Label Switched Path Down
workingLabelSwitchedPathAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.7760
Working Label Switched Path Alarm Indication Signal
protectLabelSwitchedPathAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.7765
Protect Label Switched Path Alarm Indication Signal
workingLabelSwitchedPathRemoteDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.7770
Working Label Switched Path Remote Defect Indication
protectLabelSwitchedPathRemoteDefectIndication











.1.3.6.1.4.1.3607.6.10.30.0.7775
Protect Label Switched Path Remote Defect Indication
bidirectionalForwardDetectionDown











.1.3.6.1.4.1.3607.6.10.30.0.7780
Bidirectional Forward Detection Down
tpTrafficSwitchedFromWorkingToProtection











.1.3.6.1.4.1.3607.6.10.30.0.7785
Tp Traffic Switched From Working To Protection
workingTpLockout











.1.3.6.1.4.1.3607.6.10.30.0.7790
working Tp Lockout
protectTpLockout











.1.3.6.1.4.1.3607.6.10.30.0.7795
protect Tp Lockout
stratum4Traceable











.1.3.6.1.4.1.3607.6.10.30.0.780
stratum 4 Traceable
ethernetFlowPointFailed











.1.3.6.1.4.1.3607.6.10.30.0.7800
Ethernet Flow Point Failed
teTunnelDown











.1.3.6.1.4.1.3607.6.10.30.0.7805
TE Tunnel Down
macSystemLimitReached











.1.3.6.1.4.1.3607.6.10.30.0.7810
MAC System Limit Reached
macBridgeDomainLimitReached











.1.3.6.1.4.1.3607.6.10.30.0.7815
MAC Bridge Domain Limit Reached
autoSensingDisabled











.1.3.6.1.4.1.3607.6.10.30.0.7820
Auto Sense Disabled
smBackwardIncomingAlignmentError











.1.3.6.1.4.1.3607.6.10.30.0.7825
SM Backward Incoming Alignment Error
resourceAllocationFailed











.1.3.6.1.4.1.3607.6.10.30.0.7830
Resource Allocation Failed
lossOfDFBSignal











.1.3.6.1.4.1.3607.6.10.30.0.7835
loss Of DFB Signal
workingLabelSwitchedPathLinkDownIndication











.1.3.6.1.4.1.3607.6.10.30.0.7840
Working Label Switched Path Link Down Indication
protectLabelSwitchedPathLinkDownIndication











.1.3.6.1.4.1.3607.6.10.30.0.7845
Protect Label Switched Path Link Down Indication
workingLabelSwitchedPathLockReport











.1.3.6.1.4.1.3607.6.10.30.0.7850
Working Label Switched Path Lock Report
protectLabelSwitchedPathLockReport











.1.3.6.1.4.1.3607.6.10.30.0.7855
Protect Label Switched Path Lock Report
satellitePanelBatteryFailureB











.1.3.6.1.4.1.3607.6.10.30.0.7860
satellite Panel Battery FailureB
highBitErrorRate











.1.3.6.1.4.1.3607.6.10.30.0.7865
High Bit Error Rate
backPanelFacilityLoopback











.1.3.6.1.4.1.3607.6.10.30.0.7870
Back Panel Facility Loopback
backPanelTerminalLoopback











.1.3.6.1.4.1.3607.6.10.30.0.7875
Back Panel Terminal Loopback
trunkPayloadTypeMismatch











.1.3.6.1.4.1.3607.6.10.30.0.7880
Payload Mismatch
invalidMuxponderConfiguration











.1.3.6.1.4.1.3607.6.10.30.0.7885
Invalid Muxponder Configuration
coolingProfileMismatch











.1.3.6.1.4.1.3607.6.10.30.0.7890
Cooling Profile Mismatch
trunkOduAlarmIndicationSignal











.1.3.6.1.4.1.3607.6.10.30.0.7895
Trunk ODU: Alarm Indication Signal
doNotUseForSynchronization











.1.3.6.1.4.1.3607.6.10.30.0.790
do not Use for Synchronization
companionCardMissing











.1.3.6.1.4.1.3607.6.10.30.0.7900
Companion Card Missing
controlPlaneUnverifiedClearedAlarmsPresent











.1.3.6.1.4.1.3607.6.10.30.0.7905
Control Plane Unverified Cleared Alarms Present
powerConsumptionLimitHasCrossed











.1.3.6.1.4.1.3607.6.10.30.0.7910
Power Consumption Limit Has Crossed
masterKeyExchangeFailed











.1.3.6.1.4.1.3607.6.10.30.0.7915
Master Key Exchange Failed
unitHighTemperature











.1.3.6.1.4.1.3607.6.10.30.0.7930
Unit High Temperature
overTemperatureUnitProtected











.1.3.6.1.4.1.3607.6.10.30.0.7935
Over Temperature Unit Protected
seqMismatchCount











.1.3.6.1.4.1.3607.6.10.30.0.7945
Sequence Mismatch Count
keyProgramOnAlteraFpgaFailed











.1.3.6.1.4.1.3607.6.10.30.0.7960
Key Program On Altera FPGA Failed
duplicateNodeControllerDetected











.1.3.6.1.4.1.3607.6.10.30.0.7970
Duplicate Node Controller Detected
restorationInProg











.1.3.6.1.4.1.3607.6.10.30.0.7975
Restoration in Progress
ramanPumpsCalibrationProcedureIsRunning











.1.3.6.1.4.1.3607.6.10.30.0.7980
Raman Calibration Running
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes











.1.3.6.1.4.1.3607.6.10.30.0.7985
Raman Calibration Pending
alarmIndicationSignalLine











.1.3.6.1.4.1.3607.6.10.30.0.80
alarm indication signal LINE
reservedForNetworkSynchronizationUse











.1.3.6.1.4.1.3607.6.10.30.0.800
reserved for Network Synchronization Use
outgoingFailureCondition











.1.3.6.1.4.1.3607.6.10.30.0.810
outgoing failure condition
remoteDefectIndicationLine











.1.3.6.1.4.1.3607.6.10.30.0.820
remote Defect Indication LINE
remoteDefectIndicationPath











.1.3.6.1.4.1.3607.6.10.30.0.830
remote Defect Indication Path
freeRunningSynchronizationMode











.1.3.6.1.4.1.3607.6.10.30.0.840
free Running Synchronization mode
holdoverSynchronizationMode











.1.3.6.1.4.1.3607.6.10.30.0.850
holdover synchronization mode
fastStartSynchronizationMode











.1.3.6.1.4.1.3607.6.10.30.0.860
fast Start synchronization mode
internalFault











.1.3.6.1.4.1.3607.6.10.30.0.870
Internal Fault
internalError











.1.3.6.1.4.1.3607.6.10.30.0.880
Internal Error
internalMessageError











.1.3.6.1.4.1.3607.6.10.30.0.890
internal Message Error
alarmIndicationSignalPath











.1.3.6.1.4.1.3607.6.10.30.0.90
alarm indication signal Path
mismatchOfEquipmentAndAttributes











.1.3.6.1.4.1.3607.6.10.30.0.900
mismatch of Equipment and Attributes
watchdogTimerTimeout











.1.3.6.1.4.1.3607.6.10.30.0.910
watchdog Timer Timeout
softwareFaultOrFailure











.1.3.6.1.4.1.3607.6.10.30.0.920
software Fault or failure
softwareFaultDataIntegrityFault











.1.3.6.1.4.1.3607.6.10.30.0.930
software Fault -  Data integrity fault :
The newly added provisioning or hardware has
caused the database to grow beyond its limit.
That is, the newly added object(s) in the system
has(have) enough memory to exist onboard but
too large to be saved in the database.
programFailure











.1.3.6.1.4.1.3607.6.10.30.0.940
program failure
controlEquipmentFailure











.1.3.6.1.4.1.3607.6.10.30.0.950
control Equipment failure
primaryNonVolatileBackupMemoryFailure











.1.3.6.1.4.1.3607.6.10.30.0.960
Primary Non-Volatile Backup Memory Failure
secondaryNonVolatileBackupMemoryFailure











.1.3.6.1.4.1.3607.6.10.30.0.970
Secondary Non-Volatile Backup Memory Failure
controlBusFailure











.1.3.6.1.4.1.3607.6.10.30.0.980
Control Bus Failure
controlBus1Failure











.1.3.6.1.4.1.3607.6.10.30.0.990
Control Bus 1 Failure