CAMBIUM-NETWORKS-TRANSCEIVER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
15
.1.3.6.1.4.1.2076.81.18.1.1.11 · 1 row entry · 15 columns
Uses the cambium variant from /opt/observium/mibs/cambium.
Command help
Walk cnTransceiverPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CAMBIUM-NETWORKS-TRANSCEIVER-MIB' -M '/opt/observium/mibs/cambium:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CAMBIUM-NETWORKS-TRANSCEIVER-MIB::cnTransceiverPortTable'
Port-specific data related to the transceivers
cnTransceiverPortEntry row .1.3.6.1.4.1.2076.81.18.1.1.11.1
Port-specific data related to the transceivers
Column Syntax OID
Port (ifIndex) identifier attribute
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.2076.81.18.1.1.11.1.1
Get the TX status of SFP ports
Enumeration
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.2076.81.18.1.1.11.1.2
Read transceiver capabilities
Enumeration
Enumerated Values:
1cn1000BASE-T
2cn1000BASE-CX
3cn1000BASE-LX
4cn1000BASE-SX
5cn10GBASE-SR
6cn10GBASE-LR
7cn10GBASE-ER
8cn10GBASE-LRM
9cn10GBASE-SW
10cn10GBASE-LW
11cn10GBASE-EW
.1.3.6.1.4.1.2076.81.18.1.1.11.1.3
Read the transceiver wavelength
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.2076.81.18.1.1.11.1.4
Read the transceiver vendor name
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.5
Read the transceiver vendor Organizational Unique Identifier
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.6
Read the transceiver vendor part number
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.7
Read the transceiver vendor revision
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.8
Read the transceiver vendor serial
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.9
Read the transceiver manufacturing date code
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2076.81.18.1.1.11.1.10
Internally measured transceiver temperature. A value of -32768 indicates that the temperature is unknown.
celsiusInteger32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.2076.81.18.1.1.11.1.11
Internally measured supply voltage in transceiver. A value of -32768 indicates that the voltage is unknown.
milli-voltsInteger32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.2076.81.18.1.1.11.1.12
Internally measured TX Bias Current. A value of -32768 indicates that the TX Bias Current is unknown.
micro-ampsInteger32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.2076.81.18.1.1.11.1.13
Measured TX output power. A value of -32768 indicates that the TX output power is unknown.
micro-wattsInteger32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.2076.81.18.1.1.11.1.14
Measured RX input power.. A value of -32768 indicates that the RX input power is unknown.
micro-wattsInteger32
Constraints:
range: -2147483648-2147483647
.1.3.6.1.4.1.2076.81.18.1.1.11.1.15