CAMBIUM-NETWORKS-TRANSCEIVER-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
15
cnTransceiverPortTable
table.1.3.6.1.4.1.2076.81.18.1.1.11
·
1 row entry
·
15 columns
Uses the cambium variant from
Command help
/opt/observium/mibs/cambium.
Walk cnTransceiverPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CAMBIUM-NETWORKS-TRANSCEIVER-MIB' -M '/opt/observium/mibs/cambium:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CAMBIUM-NETWORKS-TRANSCEIVER-MIB::cnTransceiverPortTable'
Port-specific data related to the transceivers
Port-specific data related to the transceivers
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Port (ifIndex) identifier attribute
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.1 |
||||||||||||||||||||||
|
Get the TX status of SFP ports
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2076.81.18.1.1.11.1.2 |
||||||||||||||||||||||
|
Read transceiver capabilities
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2076.81.18.1.1.11.1.3 |
||||||||||||||||||||||
|
Read the transceiver wavelength
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.4 |
||||||||||||||||||||||
|
Read the transceiver vendor name
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.5 |
||||||||||||||||||||||
|
Read the transceiver vendor Organizational Unique Identifier
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.6 |
||||||||||||||||||||||
|
Read the transceiver vendor part number
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.7 |
||||||||||||||||||||||
|
Read the transceiver vendor revision
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.8 |
||||||||||||||||||||||
|
Read the transceiver vendor serial
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.9 |
||||||||||||||||||||||
|
Read the transceiver manufacturing date code
|
OctetString Constraints: range: 0-32 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.10 |
||||||||||||||||||||||
|
Internally measured transceiver temperature. A value of -32768 indicates that the temperature is unknown.
|
celsiusInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.11 |
||||||||||||||||||||||
|
Internally measured supply voltage in transceiver. A value of -32768 indicates that the voltage is unknown.
|
milli-voltsInteger32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.12 |
||||||||||||||||||||||
|
Internally measured TX Bias Current. A value of -32768 indicates that the TX Bias Current is unknown.
|
micro-ampsInteger32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.13 |
||||||||||||||||||||||
|
Measured TX output power. A value of -32768 indicates that the TX output power is unknown.
|
micro-wattsInteger32 Constraints: range: -2147483648-2147483647 |
.1.3.6.1.4.1.2076.81.18.1.1.11.1.14 |
||||||||||||||||||||||
|
Measured RX input power.. A value of -32768 indicates that the RX input power is unknown.
|
micro-wattsInteger32 Constraints: range: -2147483648-2147483647 |