CAMBIUM-NETWORKS-RPS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
14

cnRPSTable

table
.1.3.6.1.4.1.17713.24.6.1 · 1 row entry · 14 columns
Uses the cambium variant from /opt/observium/mibs/cambium.
Command help
Walk cnRPSTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CAMBIUM-NETWORKS-RPS-MIB' -M '/opt/observium/mibs/cambium:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CAMBIUM-NETWORKS-RPS-MIB::cnRPSTable'
RPS entry
cnRPSTableEntry row .1.3.6.1.4.1.17713.24.6.1.1
Port-specific data related to the transceivers
Indexes
Column Syntax OID
RPS index identifier attribute
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.17713.24.6.1.1.1
Rated output voltage of power supply.
voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.2
Maximum output current rating of the power supply.
ampsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.3
Maximum output power rating of the power supply.
wattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.4
Status of power supply.
Enumeration
Enumerated Values:
1ok
2error
3notpresent
.1.3.6.1.4.1.17713.24.6.1.1.5
Current input voltage applied to the power supply.
voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.6
Current input power drawn by the power supply.
wattsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.7
Minimum input voltage rating of the power supply.
voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.8
Maximum input voltage rating of the power supply.
voltsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.9
Current temperature of the power supply.
celsiusSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.17713.24.6.1.1.10
Faults reported by the power supply.
Bits
Enumerated Values:
0noFault
1cml
2temperature
3inputUnderVoltage
4outputOverCurrent
5outputOverVoltage
6disabled
7busy
8unknown
9other
10fan
11notPowerGood
12mfr
13input
14outputPower
15outputVoltage
16invalidCommand
17invalidData
18packetErrorCheckFailed
19memoryFaultDetected
20processorFaultDetected
22otherCommunicationFault
23otherMemoryOrLogicFault
24overTemperatureFault
25overTemperatureWarning
26underTemperatureWarning
27underTemperatureFault
32outputOverCurrentFault
33outputOverCurrentFaultLVShutdown
34outputOverCurrentWarning
35outputUnderCurrentFault
36currentShareFault
37inPowerLimitingMode
38outputOverPowerFault
39outputOverPowerWarning
40outputOverVoltageFault
41outputOverVoltageWarning
42outputUnderVoltageWarning
43outputUnderVoltageFault
44outputMaxMinWarning
45tonMaxFault
46toffMaxWarning
47outputVoltageTrackingError
48inputOverVoltageFault
49inputOverVoltageWarning
50inputUnderVoltageWarning
51inputUnderVoltageFault
52unitOffForLowInputVoltage
53inputOverCurrentFault
54inputOverCurrentWarning
55inputOverPowerWarning
56fan1Fault
57fan2Fault
58fan1Warning
59fan2Warning
60fan1SpeedOverride
61fan2SpeedOverride
62airFlowFault
63airFlowWarning
.1.3.6.1.4.1.17713.24.6.1.1.11
Power supply type.
Enumeration
Enumerated Values:
1ac
2dc
.1.3.6.1.4.1.17713.24.6.1.1.12
Power supply model name.
OctetString
Constraints:
range: 16-16
.1.3.6.1.4.1.17713.24.6.1.1.13
Power supply serial number.
OctetString
Constraints:
range: 16-16
.1.3.6.1.4.1.17713.24.6.1.1.14