Baytech-MIB-403-1 Table View
Table-centric layout grouping table, row, and column objects.
Tables
12
Rows
12
Columns
120
.1.3.6.1.4.1.4779.1.2.8.4
·
1 row entry
·
2 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTANetworkConfigSNMPTrapReceiverTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTANetworkConfigSNMPTrapReceiverTable'
A list of managers to send traps to. The number of entries is given by the value of sBTANetworkConfigSNMPNumTrapReceivers. Maximum number of Trap Receivers is four.
Table of managers to send traps to.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
trapIndexmandatory
The index to a trap receiver entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.2.8.4.1.1 |
|
receiverAddressmandatory
The IP address of the manager to send traps to.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.4779.1.2.8.4.1.2 |
.1.3.6.1.4.1.4779.1.3.5.2
·
1 row entry
·
24 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCTable'
Allows for control of individual outlets and individual RPC modules.
The RPCs to control and get status on.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAModulesRPCIndexmandatory
The index into the RPC table. Indexes for rpcs attached to ds74 modules are calculate with the following formula:
((module - 2) * 4) + port. For example module 3 port 1 = index 5. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.1 |
||||||||||||||
|
sBTAModulesRPCNamemandatory
The name (unit id) of the rpc.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.2.1.2 |
||||||||||||||
|
sBTAModulesRPCFirmwareVersionmandatory
The firware version of the rpc.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.3 |
||||||||||||||
|
sBTAModulesRPCCurrentmandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.4 |
||||||||||||||
|
sBTAModulesRPCMaxCurrentmandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.5 |
||||||||||||||
|
sBTAModulesRPCVoltagemandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.6 |
||||||||||||||
|
sBTAModulesRPCPowermandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.7 |
||||||||||||||
|
sBTAModulesRPCTemperaturemandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.8 |
||||||||||||||
|
sBTAModulesRPCRebootTimeoutmandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.9 |
||||||||||||||
|
sBTAModulesRPCAllOutletsCmdmandatory
Turns all outlets on, off or reboot.
0 = off 1 = on 2 = reboot A get will return unknown (6). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.2.1.10 |
||||||||||||||
|
sBTAModulesRPCAllOutletsStatusmandatory
Reports status of outlets in a comma deliminated string.
0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.11 |
||||||||||||||
|
sBTAModulesRPCCurrentAlarmThresholdmandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.12 |
||||||||||||||
|
sBTAModulesRPCOverVoltageThresholdmandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.13 |
||||||||||||||
|
sBTAModulesRPCUnderVoltageThresholdmandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.14 |
||||||||||||||
|
sBTAModulesRPCNumberOfOutletsmandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.15 |
||||||||||||||
|
sBTAModulesRPCCircuitBreakermandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.2.1.16 |
||||||||||||||
|
sBTAModulesRPCOverTempThresholdmandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.17 |
||||||||||||||
|
sBTAModulesRPCUnitVAmandatory
Total Volt-Amps for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.18 |
||||||||||||||
|
sBTAModulesRPCNumberOfBreakersmandatory
Number of breakers for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.19 |
||||||||||||||
|
sBTAModulesRPCLowCurrentThresholdmandatory
Low current threshold for this RPC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.20 |
||||||||||||||
|
sBTAModulesRPCVoltageSourcemandatory
Voltage source for this RPC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.21 |
||||||||||||||
|
sBTAModulesRPCSourceSwitchCountmandatory
Count of Voltage Source Switches for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.22 |
||||||||||||||
|
sBTAModulesRPCNumberOfSensorsmandatory
Number of environmental sensors for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.2.1.23 |
||||||||||||||
|
sBTAModulesRPCTypemandatory
The type of RPC installed at the indexed location.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.2.1.24 |
.1.3.6.1.4.1.4779.1.3.5.3
·
1 row entry
·
4 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCOutletTable'
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
The outlets to control and get status on.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAModulesRPCOutletModuleIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.3.1.1 |
||||||||||||||
|
sBTAModulesRPCOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.3.1.2 |
||||||||||||||
|
sBTAModulesRPCOutletStatemandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.3.1.3 |
||||||||||||||
|
sBTAModulesRPCOutletNamemandatory
The name of the outlet. Maximum size is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.3.1.4 |
.1.3.6.1.4.1.4779.1.3.5.5
·
1 row entry
·
25 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCModPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCModPortTable'
Allows for control of individual outlets and individual RPC modules. The number of entries is contained in the sBTAModulesNumberOfRPCModules OID.
The RPCs to control and get status on.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sRPCModuleIndexmandatory
The module number index into the RPC table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.1 |
||||||||||||||
|
sRPCPortIndexmandatory
The port number index into the RPC table. In the case of ds30 modules this number is always 1.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.2 |
||||||||||||||
|
sRPCTypemandatory
Type of RPC at the module, port index.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.5.1.3 |
||||||||||||||
|
sRPCNamemandatory
The name (unit id) of the rpc module.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.5.1.4 |
||||||||||||||
|
sRPCFirmwareVersionmandatory
The firware version of the rpc module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.5.1.5 |
||||||||||||||
|
sRPCCurrentmandatory
The current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.6 |
||||||||||||||
|
sRPCMaxCurrentmandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. Setting this value to 0 will clear the maximum current detected. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.7 |
||||||||||||||
|
sRPCVoltagemandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.8 |
||||||||||||||
|
sRPCPowermandatory
The power reading for the power strip.
If power measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.9 |
||||||||||||||
|
sRPCTemperaturemandatory
The temperature reading for the power strip. Readings are in degrees C.
If temperature measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.10 |
||||||||||||||
|
sRPCRebootTimeoutmandatory
The length of off time for automatic reboot sequences.
Currently a read-only value set to the fixed reboot timeout. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.11 |
||||||||||||||
|
sRPCAllOutletsCmdmandatory
Turns all outlets on, off or reboot.
0 = off 1 = on 2 = reboot 3 = lockon (will lock outlets to on state) 4 = lockoff (will lock outlets to off state) 5 = unlock (will unlock all outlets) A get will retur… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.5.1.12 |
||||||||||||||
|
sRPCAllOutletsStatusmandatory
Reports status of outlets in a comma deliminated string.
0 = off 1 = on 2 = reboot 3 = locked on 4 = locked off |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.3.5.5.1.13 |
||||||||||||||
|
sRPCCurrentAlarmThresholdmandatory
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.14 |
||||||||||||||
|
sRPCOverVoltageThresholdmandatory
The over voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.15 |
||||||||||||||
|
sRPCUnderVoltageThresholdmandatory
The under voltage alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.16 |
||||||||||||||
|
sRPCNumberOfOutletsmandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.17 |
||||||||||||||
|
sRPCCircuitBreakermandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.5.1.18 |
||||||||||||||
|
sRPCOverTempThresholdmandatory
The over temperature alarm threshold level *10. A value of 505 will set the level to 50.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.19 |
||||||||||||||
|
sRPCUnitVAmandatory
Number of outlets for this RPC.
This will be the size of outlet table for this RPC index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.20 |
||||||||||||||
|
sRPCNumberOfBreakersmandatory
Number of breakers for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.21 |
||||||||||||||
|
sRPCLowCurrentThresholdmandatory
Low current threshold for this RPC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.22 |
||||||||||||||
|
sRPCVoltageSourcemandatory
Voltage source for this RPC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.23 |
||||||||||||||
|
sRPCSourceSwitchCountmandatory
Voltage source switch count for this RPC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.24 |
||||||||||||||
|
sRPCNumberOfSensorsmandatory
Number of sensors for this RPC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.5.1.25 |
.1.3.6.1.4.1.4779.1.3.5.6
·
1 row entry
·
5 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCModPortOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCModPortOutletTable'
Allows for control of individual outlets. The number of entries is contained in the sBTAModulesRPCOutletTableSize OID.
The outlets to control and get status on.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sRPCOutletModuleIndexmandatory
The module index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.1 |
||||||||||||||
|
sRPCOutletPortIndexmandatory
The port index to the outlet entry. In the case of ds30s this number is always 1.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.2 |
||||||||||||||
|
sRPCOutletIndexmandatory
The outlet index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.6.1.3 |
||||||||||||||
|
sRPCOutletStatemandatory
Getting this variable will return the state of the outlet.
Valid return states are unknown, on, off, lockon, lockoff. 0 = off 1 = on 2 = reboot 3 = lockon (outlet is on and no changes are allowed) 4 = lockoff (outlet is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.6.1.4 |
||||||||||||||
|
sRPCOutletNamemandatory
The name of the outlet. Maximum size is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.6.1.5 |
.1.3.6.1.4.1.4779.1.3.5.8
·
1 row entry
·
5 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCCurrentGroupsCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCCurrentGroupsCurrentTable'
A list of total current for RPCs in each current group
Table of total current measurement by group
Indexes
| Column | Syntax | OID |
|---|---|---|
|
groupCurrentIndexmandatory
The index to a group total current.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.1 |
|
groupCurrentmandatory
Current total for all RPCs in group.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.2 |
|
rpcGroupmandatory
A character string listing the RPCs, by port index, that will be
included in a measurement of total current. For each group, a sum will be periodically computed of currents of all listed RPCs, which will be compared to… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.8.1.3 |
|
warningThresholdmandatory
The current level, in tenths of an amp, that will cause a Current
Level Warning trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Warning Clear trap will be sent w… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.4 |
|
emergencyThresholdmandatory
The current level, in tenths of an amp, that will cause a Current
Level Emergency trap to be sent if the total current for the associated group if exceeded. Conversely, a Current Level Emergeny Clear trap will be sen… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.8.1.5 |
.1.3.6.1.4.1.4779.1.3.5.9
·
1 row entry
·
9 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesRPCBreakersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesRPCBreakersTable'
Allows monitoring of individual outlet strips on RPCs.
Status organization by breaker.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sBTAModulesRPCBreakersModulesIndexmandatory
The index into the RPC table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.1 |
||||
|
sBTAModulesRPCBreakersBreakersIndexmandatory
The index into the RPC breaker table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.2 |
||||
|
sBTAModulesRPCBreakersCircuitBreakermandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.9.1.3 |
||||
|
sBTAModulesRPCBreakersCurrentmandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.4 |
||||
|
sBTAModulesRPCBreakersMaxCurrentmandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.5 |
||||
|
sBTAModulesRPCBreakersVoltagemandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.6 |
||||
|
sBTAModulesRPCBreakersPowermandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.7 |
||||
|
sBTAModulesRPCBreakersVAmandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.8 |
||||
|
The current alarm threshold level *10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.9.1.9 |
.1.3.6.1.4.1.4779.1.3.5.10
·
1 row entry
·
10 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sRPCModPortBreakersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sRPCModPortBreakersTable'
Allows monitoring of individual outlet strips on RPCs.
Status organization by breaker.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sRPCBreakersModIndexmandatory
The module index into the RPC breaker table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.1 |
||||
|
sRPCBreakersPortIndexmandatory
The port index into the RPC breaker table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.2 |
||||
|
sRPCBreakersBreakersIndexmandatory
The breaker index into the RPC breaker table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.3 |
||||
|
sRPCBreakersCircuitBreakermandatory
Status of circuit breaker in power strip. 0=off 1=on.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.10.1.4 |
||||
|
sRPCBreakersCurrentmandatory
The detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.5 |
||||
|
sRPCBreakersMaxCurrentmandatory
The maximum detected current reading for the power strip.
If current measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.6 |
||||
|
sRPCBreakersVoltagemandatory
The voltage reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.7 |
||||
|
sRPCBreakersPowermandatory
The power reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.8 |
||||
|
sRPCBreakersVAmandatory
The volt-amps reading for the power strip.
If voltage measurement is not installed this value will always read 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.9 |
||||
|
sRPCBreakersCurrentAlarmThresholdmandatory
The current alarm threshold level x10. A value of 105 will set the level to 10.5.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.10.1.10 |
.1.3.6.1.4.1.4779.1.3.5.11
·
1 row entry
·
4 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sRPCOutletGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sRPCOutletGroupTable'
Allows control of outlets via a group of up to four outlets.
Organized by group number.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sRPCOutletGroupIndexmandatory
The index into the outlet group table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.3.5.11.1.1 |
||||||||||||||
|
sRPCOutletGroupNamemandatory
The name of the outlet group.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.11.1.2 |
||||||||||||||
|
sRPCOutletGroupOutletsmandatory
The list of outlets in the outlet group.
Format is mod.port.outlet,mod.port.outlet up to 4 outlets. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.3.5.11.1.3 |
||||||||||||||
|
sRPCOutletGroupCmdmandatory
Command for outlet group. Same rules as rpc commands.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.3.5.11.1.4 |
.1.3.6.1.4.1.4779.1.4.4
·
1 row entry
·
7 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAControlUserTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAControlUserTable'
A list of users and user information. The number of entries is contained in the sBTAControlNumOfLoggedUsers OID.
The users to get status on.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
sBTAControlUserIndexmandatory
The index to the user entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.1 |
||||||||
|
sBTAControlUserNamemandatory
The username of the user.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.4779.1.4.4.1.2 |
||||||||
|
sBTAControlUserAddressmandatory
The IP address of the user.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.4779.1.4.4.1.3 |
||||||||
|
sBTAControlUserConnectionmandatory
Type of connection.
If unknown, user is logging out or the connection is invalid. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4779.1.4.4.1.4 |
||||||||
|
sBTAControlUserConnModulemandatory
If the user is connected to a module, this value will
report the module number connected to. If the value is 0 the user is not connected to a module. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.5 |
||||||||
|
sBTAControlUserConnPortmandatory
The port number with in a module that the user is connected to.
This usually only applies to connections to DS74 serial modules. Intelligent modules connections are always made on port 1. If value is 0 the user is not c… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.4.4.1.6 |
||||||||
|
sBTAControlUserTerminateUsermandatory
Settings this OID to anything but 0 will terminate (log out) the user.
A get of this OID will return 0. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.4779.1.4.4.1.7 |
.1.3.6.1.4.1.4779.1.6.1
·
1 row entry
·
12 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sBTAModulesEnvironmentalObjectsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sBTAModulesEnvironmentalObjectsTable'
Allows monitoring of individual outlet strips on RPCs.
Status organization by sensor.
| Column | Syntax | OID |
|---|---|---|
|
sBTAModulesEnvironmentalModulesIndexmandatory
Module Index for Environemntal table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.1 |
|
sBTAModulesEnvironmentalSensorsIndexmandatory
Sensor Index for Environemntal table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.2 |
|
sBTAModulesEnvironmentalTypemandatory
Environmental Object Type.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.3 |
|
sBTAModulesEnvironmentalNamemandatory
The name for the environmental object.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.6.1.1.4 |
|
sBTAModulesEnvironmentalMeasurementmandatory
The measurement or state for the object.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.5 |
|
sBTAModulesEnvironmentalHiThresholdmandatory
Hi threshold for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.6 |
|
sBTAModulesEnvironmentalLoThresholdmandatory
Lo threshold for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.7 |
|
sBTAModulesEnvironmentalMaxmandatory
Max value recorded for object since last reset.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.8 |
|
sBTAModulesEnvironmentalMinmandatory
Min value recorded for object since last reset.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.9 |
|
Hi threshold enable for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.10 |
|
Lo threshold enable for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.11 |
|
sBTAModulesEnvironmentalStateTrapEnmandatory
Trap enable for environmental sensors with contacts.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.1.1.12 |
.1.3.6.1.4.1.4779.1.6.2
·
1 row entry
·
13 columns
Uses the baytech variant from
Command help
/opt/observium/mibs/baytech.
Walk sRPCEnvironmentalObjectsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Baytech-MIB-403-1' -M '/opt/observium/mibs/baytech:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Baytech-MIB-403-1::sRPCEnvironmentalObjectsTable'
Allows monitoring of individual outlet strips on RPCs.
Status organization by sensor.
Indexes
sBTAEnvironmentalModuleIndex sBTAEnvironmentalPortIndex sBTAEnvironmentalSensorsIndex
| Column | Syntax | OID |
|---|---|---|
|
sRPCEnvironmentalModuleIndexmandatory
Module Index for Environemntal table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.1 |
|
sRPCEnvironmentalPortIndexmandatory
Port Index for Environemntal table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.2 |
|
sRPCEnvironmentalSensorsIndexmandatory
Sensor Index for Environemntal table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.3 |
|
sRPCEnvironmentalTypemandatory
Environmental Object Type.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.4 |
|
sRPCEnvironmentalNamemandatory
The name for the environmental object.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.4779.1.6.2.1.5 |
|
sRPCEnvironmentalMeasurementmandatory
The measurement or state for the object.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.6 |
|
sRPCEnvironmentalHiThresholdmandatory
Hi threshold for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.7 |
|
sRPCEnvironmentalLoThresholdmandatory
Lo threshold for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.8 |
|
sRPCEnvironmentalMaxmandatory
Max value recorded for object since last reset.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.9 |
|
sRPCEnvironmentalMinmandatory
Min value recorded for object since last reset.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.10 |
|
sRPCEnvironmentalHiThresholdEnmandatory
Hi threshold enable for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.11 |
|
sRPCEnvironmentalLoThresholdEnmandatory
Lo threshold enable for object.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.12 |
|
sRPCEnvironmentalStateTrapEnmandatory
Trap enable for environmental sensors with contacts.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4779.1.6.2.1.13 |