BETTER-NETWORKS-ETHERNETBOX-MIB

Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors System information
Explore Observium network monitoring
Source file
BETTER-NETWORKS-ETHERNETBOX-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC1155-SMI Counter
Objects (44)
9 directly used by Observium
org
.1.3
dod
.1.3.6
.1.3.6.1
.1.3.6.1.4
.1.3.6.1.4.1
.1.3.6.1.4.1.14848
.1.3.6.1.4.1.14848.2
.1.3.6.1.4.1.14848.2.1
.1.3.6.1.4.1.14848.2.1.1
version OBS ✓ mandatory
.1.3.6.1.4.1.14848.2.1.1.1
location OBS ✓ mandatory r/w
.1.3.6.1.4.1.14848.2.1.1.2
tempunit OBS ✓ mandatory
Integer32
.1.3.6.1.4.1.14848.2.1.1.3
refreshinterval mandatory
Integer32
.1.3.6.1.4.1.14848.2.1.1.4
numbersensors mandatory
Integer32
.1.3.6.1.4.1.14848.2.1.1.5
address mandatory
.1.3.6.1.4.1.14848.2.1.1.6
uptime OBS ✓ mandatory
.1.3.6.1.4.1.14848.2.1.1.7
sensorTable mandatory
.1.3.6.1.4.1.14848.2.1.2
sensorEntry OBS ✓ mandatory
.1.3.6.1.4.1.14848.2.1.2.1
sensorindex mandatory
.1.3.6.1.4.1.14848.2.1.2.1.1
hysteresis mandatory r/w
.1.3.6.1.4.1.14848.2.1.2.1.10
status mandatory
.1.3.6.1.4.1.14848.2.1.2.1.11
name OBS ✓ mandatory r/w
.1.3.6.1.4.1.14848.2.1.2.1.2
sensortype OBS ✓ mandatory r/w
.1.3.6.1.4.1.14848.2.1.2.1.3
valueint OBS ✓ mandatory
.1.3.6.1.4.1.14848.2.1.2.1.4
valueint10 OBS ✓ mandatory
.1.3.6.1.4.1.14848.2.1.2.1.5
valuestr mandatory
.1.3.6.1.4.1.14848.2.1.2.1.6
valid mandatory
.1.3.6.1.4.1.14848.2.1.2.1.7
lowlimit mandatory r/w
.1.3.6.1.4.1.14848.2.1.2.1.8
highlimit mandatory r/w
.1.3.6.1.4.1.14848.2.1.2.1.9
inputTable mandatory
.1.3.6.1.4.1.14848.2.1.3
inputEntry mandatory
.1.3.6.1.4.1.14848.2.1.3.1
inputindex mandatory
.1.3.6.1.4.1.14848.2.1.3.1.1
inputstatus mandatory
.1.3.6.1.4.1.14848.2.1.3.1.2
outputTable mandatory
.1.3.6.1.4.1.14848.2.1.4
outputEntry mandatory
.1.3.6.1.4.1.14848.2.1.4.1
outputindex mandatory
.1.3.6.1.4.1.14848.2.1.4.1.1
outputstatus mandatory r/w
.1.3.6.1.4.1.14848.2.1.4.1.2
analogTable mandatory
.1.3.6.1.4.1.14848.2.1.5
analogEntry mandatory
.1.3.6.1.4.1.14848.2.1.5.1
analogindex mandatory
.1.3.6.1.4.1.14848.2.1.5.1.1
analogname mandatory r/w
.1.3.6.1.4.1.14848.2.1.5.1.2
analogvalueint mandatory
.1.3.6.1.4.1.14848.2.1.5.1.3
analogvalueint10 mandatory
.1.3.6.1.4.1.14848.2.1.5.1.4
analogvaluestr mandatory
.1.3.6.1.4.1.14848.2.1.5.1.5
Dependencies (2) 2 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC1155-SMIrfc
  3. BETTER-NETWORKS-ETHERNETBOX-MIBmesspcselected
Type Definitions (1)
OctetString
Notifications / Traps (11)
NameOIDDescription
.1.3.6.1.4.1.14848.0.1
WARNING: Sensor status has changed to low
.1.3.6.1.4.1.14848.0.100
Information: Ethernetbox is switched on
.1.3.6.1.4.1.14848.0.101
Information: Ethernetbox Configuration has written
.1.3.6.1.4.1.14848.0.2
INFORMATION: Sensor status has changed to normal
.1.3.6.1.4.1.14848.0.3
WARNING: Sensor status has changed to high
.1.3.6.1.4.1.14848.0.4
Information: Input line has changed to low
.1.3.6.1.4.1.14848.0.5
Information: Input line has changed to high
.1.3.6.1.4.1.14848.100
Event sent when Ethernet Box is switched on
.1.3.6.1.4.1.14848.101
Event sent when Ethernet Box Configuration is written in flash memory
.1.3.6.1.4.1.14848.4
Event sent when status of Input line is changed to low
.1.3.6.1.4.1.14848.5
Event sent when status of Input line is changed to high